SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)

SAIC NUMBER DATE APPROVED QR NUMBER


SAUDI ARAMCO INSPECTION CHECKLIST
Location, Depth of Trench/Boreholes & Elevation for Types I
SAIC-M-1003 18-May-05 CIVIL-
- V Fences Inspection
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

EQUIPMENT ID NUMBER(S) EQUIPMENT DESCRIPTION EQPT CODE SYSTEM ID. PLANT NO.

LAYOUT DRAWING NUMBER REV. NO. PURCHASE ORDER NUMBER EC / PMCC / MCC NO.

SCHEDULED INSPECTION DATE & TIME ACTUAL INSPECTION DATE & TIME QUANTITY INSP. MH's SPENT TRAVEL TIME
SAUDI ARAMCO USE ONLY
SAUDI ARAMCO TIP NUMBER SAUDI ARAMCO ACTIVITY NUMBER WORK PERMIT REQUIRED?

SAUDI ARAMCO INSPECTION LEVEL CONTRACTOR INSPECTION LEVEL

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

A Location & Depth Inspection

General excavation shall be performed after clearing and grubbing has SAES-A-114
A1
been completed. Sec. 7.1

Excavation shall be performed as required by the IFC Drawings to the


SAES-A-114
A2 dimensions, grades, elevations, formwork if required, and with alowance
Sec. 7.2.1
for compaction equipment.

Over-excavated forms shall be back filled or leveled with F'c=2000 psi @ SAES-A-114
A3
28 days blinding concrete. Sec. 7.2.3
Drawing
A4 Formwork is not required for fence or post anchor foundations. AC-036680
Sht. NO. 1
Drawing
Corner, end and gate post foundation shall be a minimum 300mm
A5 AC-036680
diameter and 1075mm deep for fence types I, II, III and V.
Sht. NO. 1
Drawing
Special Gate Posts over 175mm O.D. shall have foundations minimum
A6 AC-036680
300mm diameter and 1320mm deep for fence types I, II, III and V.
Sht. NO. 1
Drawing
Line Post foundations shall be a minimum 250mm diameter and 1075
A7 AC-036680
mm deep for fence types I, II, III and V.
Sht. NO. 1
Brace post foundations shall be a minimum of 250mm diameter and Drawing
A8 940mm into the ground measured at the hole centerline for fence types I, AC-036680
II, III and V. Sht. NO. 1

Type VI fencing posts shall be painted with adhesive, wrapped with one Drawing
A9 wrap of pipe wrapping, and painted with a top coat of adhesive to extend AC-036681
25mm above top of concrete and 125mm into the concrete. Sht. NO. 1
Drawing
Type VI, corner and gate posts shall have foundations a minimum of
A10 AC-036681
300mm diameter and 650mm into the ground from grade elevation.
Sht. NO. 1
Drawing
Type VI line posts shall have foundations a minimum of 250mm diameter
A11 AC-036681
and 650mm into the ground from grade elevation.
Sht. NO. 1
Drawing
Type VI Brace posts shall have foundations a minimum of 250mm's
A12 AC-036681
diameter and 630mm into the ground measured at the centerline.
Sht. NO. 1
Saudi Aramco Security Fencing only shall have fence anchor blocks Drawing
A13 minimum 300mm deep and 150mm wide cast from post froundation to AC-036680
post foundation with the top surface flush with grade elevation. Sht. NO. 1
Drawing
One 8mm reinforcing bar shall run the full length of the anchor block at
A14 AC-036680
the block centerline with 75mm's clearance at the ends for concrete.
Sht. NO. 1

Page 1 of 3
SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Location, Depth of Trench/Boreholes & Elevation for Types I
SAIC-M-1003 18-May-05 Civil
- V Fences Inspection
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

One 8mm reinforcing bar shall run the full length of the anchor block
along the block centerline with 75mm's clearance at the ends, 100mm
Drawing
below the top of concrete elevation with triangular projections for
A15 AC-036680
connecting the chain link fabric 150mm's from the ends and spaced at
Sht. NO. 1
600mm on center in between. Turn downs shall exist at the ends,
150mm's long.

B Fencing Details Inspection

Drawing
B1 The top of the fence shall follow the profile of the ground. AA-036677
Sht. NO. 1
Corner panels, panels on either sides of gates and tensioning panels Drawing
B2 shall have a brace rail at the fencing centerline and a diagonal truss rod AA-036677
running from post foundation to the brace rail. Sht. NO. 1
Drawing
The fences' wire fabric shall extend from 25mm clear of grade elevation
B3 AA-036677
to 2425 mm's up from grade elevation.
Sht. NO. 1
Seven (7) bar bands shall be used to connect the fences wire fabric at
Drawing
corner posts, line posts, end and gate posts. They shall be spaced at
B4 AA-036678
360mm's on center on corner end and gate posts and 350mm on line
Sht. NO. 1
posts.
Drawing
Security Fencing types II and III shall have double corner extension arms
B5 AA-036678
with 6 strands of barbed wire on the tops of all corner posts.
Sht. NO. 1
Drawing
Security Fencing types II and III shall have double extension arms with 6
B6 AA-036678
strands of barbed wire on the tops of all line posts.
Sht. NO. 1
Drawing
Security Fencing types II and III gate posts shall have three (3) type I
B7 AA-036678
bands for connecting the barbed wire at top.
Sht. NO. 1
Drawing
Security Fencing Type II shall have double corner post extensions for
B8 AA-036678
connecting the barbed wire.
Sht. NO. 1
Drawing
Type IV shall have single corner and line post extensions for supporting
B9 AA-036678
3 strands of barbed wire at 450 from horizontal.
Sht. NO. 1
Winding brackets shall be provided for connecting top and bottom Drawing
B10 tensioning wires for fence types III, IV and V, plus at the bottoms only for AA-036678
type II fencing. Sht. NO. 1
Drawing
Type I bands shall be provided to connect 10mm diameter truss rods,
B11 AA-036678
top, bottom and brace rails.
Sht. NO. 1
Drawing
Gates shall be provided with at least 2 hinges per leaf, more as required
B12 AB-036679
by IFC Drawings or specifications.
Sht. NO. 1
Gate leaves shall be provided with latches, fork catch bars, lock keepers, Drawing
B13 strecher bars for wire fabric, plunger rods, hook bolts and diagonal truss AB-036679
rods. Sht. NO. 1
Drawing
Walk gates shall have a top rail and any barbed wire shall be continuous
B14 AB-036679
over the top of the walk gate.
Sht. NO. 1

Page 2 of 3
SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Location, Depth of Trench/Boreholes & Elevation for Types I
SAIC-M-1003 18-May-05 Civil
- V Fences Inspection
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.
REMARKS:

REFERENCE DOCUMENTS:
1- SAES-A-114 -- Excavation and Backfill, 28 April 2004
2- AC-036681, Sht. 1 -- Perimeter Fencing for Onshore Helipads, Footing Details, Type IV Fence, 1 June 1992
3- AC-036680, Sht. 1 -- Saudi Aramco Security and General Fencing, Footing Details, 3 March 1997
4- AA-036679, Sht. 1 -- Saudi Aramco Security and General Fencing, Gate Details, 4 February 1990
5- AA-036678, Sht. 1 -- Saudi Aramco Security and General Fencing, Post and Fabric Details, 4 January 1990
6- AB-036677, Sht. 1 -- An Overview (Architectural), Saudi Aramco Security and General Purpose Fencing, 2 March 1990

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED