ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

A Door and Accessories Installation Inspection

Doors with perimeter mounting flanges shall be installed with flashing


SAES-M-100
A1 sheets integrated with the weather resistant barrier.
Sec. D
(1997 UBC, Sec. 1003.3.1)

Sealants shall be applied and tooled in accordance with the


manufacturer's recommendations with respect to surface preparation, SAES-M-100
A2
application procedures and application temperatures. Sec. D
(1997 UBC, Sec. 1003.3.1)

Door and frame shall be installed square, plumb and level within the SAES-M-100
A3
specified tolerances. (1997 UBC, Sec. 1003.3.1.3 & 1003.3.1.6) Sec. D

Security and emergency exit doors, including their hardware and frames,
SAES-O-107
A4 shall be made of steel and fire-rated for the appropriate fire-separation
Sec. 5.3
rating of the wall they penetrate.

All exit-access doorways and doorways from unoccupied areas to a


corridor shall be protected by tight fitting smoke- and draft- control SAES-M-100
A5
assemblies having a fire-protection rating of not less than 20 minutes. Sec. D
(1997 UBC, Sec. 1004.3.4.3.2.1)

All interior exit door assemblies in an exit enclosure in one hour rated fire
partitions shall have a one hour fire rating; interior door assemblies in an SAES-M-100
A6
exit enclosure with a two hour rating may have an 1.5 hour fire rating. Sec. D
(1997 UBC, Sec. 1005.3.3.5)

Fire rated doors or windows required to have a 0.75, 1.0 or 1.5 hour fire
protection rating shall be either automatic or self closing assemblies; Fire
rated doors installed across a corridor shall be automatic closing SAES-M-100
A7
assemblies. All hold open devices shall release or close the door Sec. D
automatically in the event of a power failure.
(1997 UBC, Sec. 713.6.1)

Swinging fire doors shall not have less than two hinges when the door is
up to 1524mm (60in) in height, an additional hinge shall be installed for SAES-M-100
A8
each 762mm (30in) of height or fraction thereof. Sec. D
(1997 UBC, Sec. 713.6.2)

Hinges, except for spring hinges, shall be of the ball bearing or


antifriction type. When spring hinges are used for door-closing SAES-M-100
A9
purposes, not less than one half of the hinges shall be spring hinges. Sec. D
(1997 UBC, Sec. 713.6.3)

All single doors and both leaves of pairs of side-hinged swinging doors
SAES-M-100
A10 shall be provided with an automatic latch that will secure the door when it
Sec. D
is closed. (1997 UBC, Sec. 713.6.3)

Page 1 of 3
SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Metal Doors and Windows Installation Inspection SAIC-M-1049 18-May-05 Civil
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

A single door leaf of an exit door serving an occupant load of 10 or more SAES-M-100
A11
shall not exceed 1219mm (4') in width. (1997 UBC, Sec. 1003.3.1.4) Sec. D

Exit doors serving an occupant load of 10 or more shall be of the pivoted,


SAES-M-100
A12 balanced or side-hinged swinging type.
Sec. D
(1997 UBC, Sec. 1003.3.1.4)

B Windows and Accessories Installation Inspection

Sealants shall be applied and tooled in accordance with the manufact-


urer's recommendations with respect to surface preparation, application SAES-M-100
B1
procedures and application temperatures. Sec. 2404.1
(1997 UBC, Sec. 2401.4.1 & 2401.4.2)

The correct number, type and size of fasteners shall be installed at the
locations prescribed by the manufacturer for the sized window model and SAES-M-100
B2
location; The window shall be installed square without over tightening the Sec. 2404.1
fasteners. (1997 UBC, Sec. 2401.4.1 & 2401.4.2)

A weather resistant barrier shall be created around all window SAES-M-100


B3
perimeters. (1997 UBC, Sec. 2401.4.1 & 2401.4.2) Sec. D
Window frame and sash shall be installed square, plumb and level within
SAES-M-100
B4 the tolerances specified in the IFC drawings. (1997 UBC, Sec. 2401.4.1
Sec. D
& 2401.4.2)
Windows in (inside) corridor walls shall be protected by fire glazing listed
and labeled or marked with the for a fire-protection rating of at least three-
fourths hour, neither width or height shall exceed 3.670m (12') nor be SAES-M-100
B5
less than 102mm and the total area of glazed observation panel Sec. D
openings in pairs of doors shall not exceed 15.5cm2 (100in2).
(1997 UBC, Sec. 1004.3.4.3.2.2)

Fire rated glazing materials and glass block assemblies shall be qualified
by Saudi Aramco approved tests; They shall be labeled for the required SAES-M-100
B6
fire-protection rating and installed in accordance with it. Sec. D
(1997 UBC, Sec. 713.9)

Each light of safety glazing material installed in hazardous locations as


defined by Saudi Aramco shall be identified as safety glass by a SAES-M-100
B7
permanent label identifying the manufacturer. Sec. D
(1997 UBC, Sec. 2406.2)

Sloped glazing materials and skylights shall be made of laminated safety


glass with a minimum 0.38mm (0.015") polyvinyl butyral interlayer for
SAES-M-100
B8 glass panes less than 1.52m 2 (16ft2) in area, fully tempered glass, heat-
Sec. D
strengthened glass, wired glass or Saudi Aramco approved rigid plastic.
(1997 UBC, Sec. 2409.2)
Windows in (inside) corridor walls shall be protected by fire glazing listed
and labeled or marked with the for a fire-protection rating of at least three-
fourths hour, neither width or height shall exceed 3.670m (12') nor be SAES-M-100
B9
less than 102mm and the total area of glazed observation panel Sec. D
openings in pairs of doors shall not exceed 15.5cm2 (100in2).
(1997 UBC, Sec. 1004.3.4.3.2.2)

Fire rated glazing materials and glass block assemblies shall be qualified
by Saudi Aramco approved tests; They shall be labeled for the required SAES-M-100
B10
fire-protection rating and installed in accordance with it. Sec. D
(1997 UBC, Sec. 713.9)

Page 2 of 3
SAUDI ARAMCO ID/PID - 18-MAY-05 - REV 0 (Standards Cutoff - August 2004)
SAIC NUMBER DATE APPROVED QR NUMBER
SAUDI ARAMCO INSPECTION CHECKLIST
Metal Doors and Windows Installation Inspection SAIC-M-1049 18-May-05 Civil
PROJECT TITLE WBS / BI / JO NUMBER CONTRACTOR / SUBCONTRACTOR

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A RE-INSP DATE
No.

Each light of safety glazing material installed in hazardous locations as


defined by Saudi Aramco shall be identified as safety glass by a SAES-M-100
B11
permanent label identifying the manufacturer. Sec. D
(1997 UBC, Sec. 2406.2)

Sloped glazing materials and skylights shall be made of laminated safety


glass with a minimum 0.38mm (0.015") polyvinyl butyral interlayer for
SAES-M-100
B12 glass panes less than 1.52m 2 (16ft2) in area, fully tempered glass, heat-
Sec. D
strengthened glass, wired glass or Saudi Aramco approved rigid plastic.
(1997 UBC, Sec. 2409.2)

REMARKS:

REFERENCE DOCUMENTS:
1- SAES-M-100 -- Saudi Aramco Building Code, 29 January 2003
2- 1997 UBC -- Uniform Building Code, 1 January 1997

Contractor / Third-Party Saudi Aramco


Construction Representative* PMT Representative
Work is Complete and Ready for Inspection: T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Inspector PID Representative


Performed Inspection Work / Rework May Proceed T&I Witnessed QC Record Reviewed Work Verified
Name, Initials and Date: Name, Initials and Date:

QC Supervisor Proponent and Others


Quality Record Approved: T&I Witnessed QC Record Reviewed Work Verified
Name, Organization,
Name, Sign and Date:
Initials and Date:

*Person Responsible for Completion of Quality Work / Test Y = YES N = NO F = FAILED

Page 3 of 3

You might also like