ITEM DESCRIPTION UNIT QTY RATE (RM) AMOUNT (RM)

ELEMENT NO. 8 - SPORT RECREATIONAL


(ALL PROVISIONAL)

FOOTBALL FIELD
Excavation Works

A Excavate to reduce levels, including trim, level, M3 6,336 -


grade and compact bottom of excavation
commencing from formation level, get out, part
return, fill in, deposit, spread and remove excess
excavated material to the Contractor's own
dumping area maximum depth not exceeding
2.00m deep

B 50mm thick sand base as described, spread, M2 5,760 -


compacted and levelled with surface finish level

C Approved sand filling and compacted in layers M3 6,048 -


compaction, spread and levelled to the S.O's
approval

Subsoil Drain

D Approved 200mm diameter high tensile PVC M 346 -


coated subsoil drain reinforced with carbon steel
wire treated with rustproofing or other equivalent
including 20mm diameter agreegate and
non-woven geotextile laid in trench with all
necessary fixing, jointing, accessories and
discharging last pipe to the nearest outlet
pipe/drain all as per Engineer's detail drawing
and S.O's approval

E Approved 150mm diameter; Ditto M 1,242 -

Drainage

F Excavate trench for 600mm wide block drain M 325 -


commencing from formation level, get out, part
return, fill in and compacted with selected
excavated material as specified, temporary
works and struting and remainder deposit,
spread and level as directed depth exceeding
1.00m but not exceeding 2.00m deep

G Supply and lay approved 600mm wide precast M 325 -


block drain complete with jointed and filled in
cement and sand (1:3) mortar, concrete base
grade 20, dowel bar, 225mm thick brickwall,
plastering, concrete strut, precast slab cover,
100mm diameter PVC pipe as weephole,
granular bedding and all necessary works
related all as per Engineer's detail drawing and
S.O. approval depth exceeding 1.00m but not
exceeding 2.00m deep

TO COLLECTION -

SMK KOTA WARISAN E/8/1


BILL NO.E - EXTERNAL WORKS

ITEM DESCRIPTION UNIT QTY RATE (RM) AMOUNT (RM)

ELEMENT NO. 8 - SPORT RECREATIONAL …


(Cont'd)

FOOTBALL FIELD … (Cont'd)

Turfing

Axonopus compressus (Cow Grass) - Close


Turfing

A To supply and lay Axonopus compressus (95 % M2 5,760 -


purity), minimum sod size of 300mm x 300mm,
with minimum 20mm thk root & soil intact. Sods
to be laid with the gap between edge of sod to
be not more than 25mm. Rate to mininum 50mm
thk top soil laid over the planting area. Prior to
soiling the ground shall be graded with a
minimum fall of 2% to the nearest drain and or
water discharge outlet to avoid water ponding.
The joint between sod to be filled with suitable
top dressing and compacted to achieve an even
finish level. The turf shall be maintained
immediately upon being laid and shall remain
healthy and green throughout the contract
period

Running Track Line

B 50mm wide running track line and marking as ITEM -


specified to manufacturer recommendation,
Architect's detail drawing and S.O. approval

Football line

C 50mm wide football line and marking as specified ITEM -


to manufacturer recommendation, Architect's
detail drawing and S.O. approval

Goal post

D Approved goal post complete with netting to NO 2 -


manufacturer recommendation, Architect and
S.O. approval

Corner Flag

E Approved conner flag post to manufacturer NO 4 -


recommendation, Architect and S.O. approval

TO COLLECTION -

SMK KOTA WARISAN E/8/2


BILL NO.E - EXTERNAL WORKS

ITEM DESCRIPTION UNIT QTY RATE (RM) AMOUNT (RM)

ELEMENT NO. 8 - SPORT RECREATIONAL …


(Cont'd)

FUTSAL COURT

Excavation Works

A Excavate to reduce levels, including trim, level, M3 422 -


grade and compact bottom of excavation
commencing from formation level, get out, part
return, fill in, deposit, spread and remove excess
excavated material to the Contractor's own
dumping area maximum depth not exceeding
1.00m deep

B 75mm thick sand bedding as described, spread, M2 993 -


compacted and levelled with surface finish level

C 125mm thick crusher run aggregate as M2 993 -


described, spread, levelled, well rammed and
consolidated, watered and blinded on top with
and to receive concrete

Concrete Works

D 50mm thick lean concrete Grade 15 blinding with M3 50 -


surface finished level to receive concrete

E Vibrated reinforced concrete (Grade 37) as M3 124 -


described in slab

F Fabric reinforcement cut to size for BRC A393 in M2 993 -


slab (measured nett - no allowance made for
laps)

G Sawn formwork as described to concrete works M 123 -


to edge of slabs not exceeding 250mm high

Construction Joint

H Allow the forming any construction joint as ITEM -


specified including provision of additional
reinforcement bar, dowel bar, stop board,
formwork, infilled bituminous movement joint,
sleeve and cap etc. and all necessary works in
floor slab where the construction pour sequence
requires the provision of construction and day
joints, all to the approval of the S.O. The method
and the position of construction joint and
waterstops shall approved by the Engineer
before any commencement of related works.

TO COLLECTION -

SMK KOTA WARISAN E/8/3


BILL NO.E - EXTERNAL WORKS

ITEM DESCRIPTION UNIT QTY RATE (RM) AMOUNT (RM)

ELEMENT NO. 8 - SPORT RECREATIONAL …


(Cont'd)

FUTSAL COURT … (Cont'd)

Finishes

A 50mm thick concrete power float hardener as M2 993 -


finishes

Futsal line

B 50mm wide futsal court line and marking as ITEM -


specified to manufacturer recommendation,
Architect's detail drawing and S.O. approval

Goal post

C Approved futsal goal post complete with netting NO 2 -


to manufacturer recommendation, Architect and
S.O. approval

Drainage

D Excavate trench for 600mm wide block drain M 135 -


commencing from formation level, get out, part
return, fill in and compacted with selected
excavated material as specified, temporary
works and struting and remainder deposit,
spread and level as directed depth exceeding
1.00m but not exceeding 2.00m deep

E Supply and lay approved 600mm wide precast M 135 -


block drain complete with jointed and filled in
cement and sand (1:3) mortar, concrete base
grade 20, dowel bar, 225mm thick brickwall,
plastering, concrete strut, precast slab cover,
100mm diameter PVC pipe as weephole,
granular bedding and all necessary works
related all as per Engineer's detail drawing and
S.O. approval depth exceeding 1.00m but not
exceeding 2.00m deep

TO COLLECTION -

SMK KOTA WARISAN E/8/4


BILL NO.E - EXTERNAL WORKS

ITEM DESCRIPTION UNIT QTY RATE (RM) AMOUNT (RM)

ELEMENT NO. 8 - SPORT RECREATIONAL …


(Cont'd)

FUTSAL COURT … (Cont'd)

Fencing

A Construct and complete 6000mm high approved M 123 -


chain link fencing consists of 10 gauge 50mm x
50mm chainlink, 100mm diameter CHS steel
post, 75mm diameter CHS horizontal steel
member and support, complete with 350mm x
350mm x 300mm concrete footing, 200mm x
200mm x 300mm high concrete stump, 150mm x
125mm concrete kerb and clip/bracket including
all necessary excavation, concrete,
reinforcement, formworks, plastering, painting
and any related works all as per Architect's detail
drawing and S.O's approval

B Construct and complete chainlink gate overall NO 2 -


900mm x 2055mm high complete with frame and
10 gauge 50mm x 50mm chainlink, hinges and
lockset including all necessary painting works,
fixing and accessories all as per manufacturer's
recommendation, Architect's detail drawing and
S.O's approval

NETBALL COURT

Excavation Works

C Excavate to reduce levels, including trim, level, M3 299 -


grade and compact bottom of excavation
commencing from formation level, get out, part
return, fill in, deposit, spread and remove excess
excavated material to the Contractor's own
dumping area maximum depth not exceeding
1.00m deep

D 75mm thick sand bedding as described, spread, M2 702 -


compacted and levelled with surface finish level

E 125mm thick crusher run aggregate as M2 702 -


described, spread, levelled, well rammed and
consolidated, watered and blinded on top with
and to receive concrete

TO COLLECTION -

SMK KOTA WARISAN E/8/5


BILL NO.E - EXTERNAL WORKS

ITEM DESCRIPTION UNIT QTY RATE (RM) AMOUNT (RM)

ELEMENT NO. 8 - SPORT RECREATIONAL …


(Cont'd)

NETBALL COURT … (Cont'd)

Concrete Works

A 50mm thick lean concrete Grade 15 blinding with M3 35 -


surface finished level to receive concrete

B Vibrated reinforced concrete (Grade 37) as M3 88 -


described in slab

C Fabric reinforcement cut to size for BRC A393 in M2 702 -


slab (measured nett - no allowance made for
laps)

D Sawn formwork as described to concrete works M 104 -


to edge of slabs not exceeding 250mm high

Construction Joint

E Allow the forming any construction joint as ITEM -


specified including provision of additional
reinforcement bar, dowel bar, stop board,
formwork, infilled bituminous movement joint,
sleeve and cap etc. and all necessary works in
floor slab where the construction pour sequence
requires the provision of construction and day
joints, all to the approval of the S.O. The method
and the position of construction joint and
waterstops shall approved by the Engineer
before any commencement of related works.

Finishes

F 50mm thick concrete power float hardener as M2 702 -


finishes

Netball line

G 50mm wide netball court line and marking as ITEM -


specified to manufacturer recommendation,
Architect's detail drawing and S.O. approval

Netball goal post

H Approved netball goal post complete with netting NO 2 -


to manufacturer recommendation, Architect and
S.O. approval

TO COLLECTION -

SMK KOTA WARISAN E/8/6


BILL NO.E - EXTERNAL WORKS

ITEM DESCRIPTION UNIT QTY RATE (RM) AMOUNT (RM)

ELEMENT NO. 8 - SPORT RECREATIONAL …


(Cont'd)

NETBALL COURT … (Cont'd)

Drainage

A Excavate trench for 600mm wide block drain M 114 -


commencing from formation level, get out, part
return, fill in and compacted with selected
excavated material as specified, temporary
works and struting and remainder deposit,
spread and level as directed depth exceeding
1.00m but not exceeding 2.00m deep

B Supply and lay approved 600mm wide precast M 114 -


block drain complete with jointed and filled in
cement and sand (1:3) mortar, concrete base
grade 20, dowel bar, 225mm thick brickwall,
plastering, concrete strut, precast slab cover,
100mm diameter PVC pipe as weephole,
granular bedding and all necessary works
related all as per Engineer's detail drawing and
S.O. approval depth exceeding 1.00m but not
exceeding 2.00m deep

TAKRAW AND BADMINTON COURT

Excavation Works

C Excavate to reduce levels, including trim, level, M3 183 -


grade and compact bottom of excavation
commencing from formation level, get out, part
return, fill in, deposit, spread and remove excess
excavated material to the Contractor's own
dumping area maximum depth not exceeding
1.00m deep

D 75mm thick sand bedding as described, spread, M2 429 -


compacted and levelled with surface finish level

E 125mm thick crusher run aggregate as M2 429 -


described, spread, levelled, well rammed and
consolidated, watered and blinded on top with
and to receive concrete

Concrete Works

F 50mm thick lean concrete Grade 15 blinding with M3 22 -


surface finished level to receive concrete

G Vibrated reinforced concrete (Grade 37) as M3 54 -


described in slab

TO COLLECTION -

SMK KOTA WARISAN E/8/7


BILL NO.E - EXTERNAL WORKS

ITEM DESCRIPTION UNIT QTY RATE (RM) AMOUNT (RM)

ELEMENT NO. 8 - SPORT RECREATIONAL …


(Cont'd)

TAKRAW AND BADMINTON COURT … (Cont'd)

Concrete Works … (Cont'd)

A Fabric reinforcement cut to size for BRC A393 in M2 429 -


slab (measured nett - no allowance made for
laps)

B Sawn formwork as described to concrete works M 78 -


to edge of slabs not exceeding 250mm high

Construction Joint

C Allow the forming any construction joint as ITEM -


specified including provision of additional
reinforcement bar, dowel bar, stop board,
formwork, infilled bituminous movement joint,
sleeve and cap etc. and all necessary works in
floor slab where the construction pour sequence
requires the provision of construction and day
joints, all to the approval of the S.O. The method
and the position of construction joint and
waterstops shall approved by the Engineer
before any commencement of related works.

Finishes

D 50mm thick concrete power float hardener as M2 429 -


finishes

Takraw line

E 50mm wide takraw court line and marking as ITEM -


specified to manufacturer recommendation,
Architect's detail drawing and S.O. approval

Badminton line

F 50mm wide badminton court line and marking as ITEM -


specified to manufacturer recommendation,
Architect's detail drawing and S.O. approval

Post and net

G Approved 64mm diameter galvanised steel pipe SET 2 -


column as post overall high 1946mm with
approved netting complete with 230mm x 230mm
376 concrete base and 50mm thick lean
concrete all as per detail drawing and S.O's
approval

TO COLLECTION -

SMK KOTA WARISAN E/8/8


BILL NO.E - EXTERNAL WORKS

ITEM DESCRIPTION UNIT QTY RATE (RM) AMOUNT (RM)

ELEMENT NO. 8 - SPORT RECREATIONAL …


(Cont'd)

TAKRAW AND BADMINTON COURT … (Cont'd)

Umpire Stand

A Approved umpire chair/stand in standard size as NO 2 -


manufacturer's recommendation and S.O's
approval

Drainage

B Excavate trench for 600mm wide block drain M 86 -


commencing from formation level, get out, part
return, fill in and compacted with selected
excavated material as specified, temporary
works and struting and remainder deposit,
spread and level as directed depth exceeding
1.00m but not exceeding 2.00m deep

C Supply and lay approved 600mm wide precast M 86 -


block drain complete with jointed and filled in
cement and sand (1:3) mortar, concrete base
grade 20, dowel bar, 225mm thick brickwall,
plastering, concrete strut, precast slab cover,
100mm diameter PVC pipe as weephole,
granular bedding and all necessary works
related all as per Engineer's detail drawing and
S.O. approval depth exceeding 1.00m but not
exceeding 2.00m deep

BASKETBALL, TAKRAW AND VOLLEYBALL


COURT

Excavation Works

D Excavate to reduce levels, including trim, level, M3 161 -


grade and compact bottom of excavation
commencing from formation level, get out, part
return, fill in, deposit, spread and remove excess
excavated material to the Contractor's own
dumping area maximum depth not exceeding
1.00m deep

E 75mm thick sand bedding as described, spread, M2 378 -


compacted and levelled with surface finish level

F 125mm thick crusher run aggregate as M2 378 -


described, spread, levelled, well rammed and
consolidated, watered and blinded on top with
and to receive concrete

TO COLLECTION -

SMK KOTA WARISAN E/8/9


BILL NO.E - EXTERNAL WORKS

ITEM DESCRIPTION UNIT QTY RATE (RM) AMOUNT (RM)

ELEMENT NO. 8 - SPORT RECREATIONAL …


(Cont'd)

BASKETBALL, TAKRAW AND VOLLEYBALL


COURT … (Cont'd)

Concrete Works

A 50mm thick lean concrete Grade 15 blinding with M3 19 -


surface finished level to receive concrete

B Vibrated reinforced concrete (Grade 37) as M3 48 -


described in slab

C Fabric reinforcement cut to size for BRC A393 in M2 378 -


slab (measured nett - no allowance made for
laps)

D Sawn formwork as described to concrete works M 77 -


to edge of slabs not exceeding 250mm high

Construction Joint

E Allow the forming any construction joint as ITEM -


specified including provision of additional
reinforcement bar, dowel bar, stop board,
formwork, infilled bituminous movement joint,
sleeve and cap etc. and all necessary works in
floor slab where the construction pour sequence
requires the provision of construction and day
joints, all to the approval of the S.O. The method
and the position of construction joint and
waterstops shall approved by the Engineer
before any commencement of related works.

Finishes

F 50mm thick concrete power float hardener as M2 378 -


finishes

Basketball line

G 50mm wide basketball court line and marking as ITEM -


specified to manufacturer recommendation,
Architect's detail drawing and S.O. approval

Takraw line

H 50mm wide takraw court line and marking as ITEM -


specified to manufacturer recommendation,
Architect's detail drawing and S.O. approval

TO COLLECTION -

SMK KOTA WARISAN E/8/10


BILL NO.E - EXTERNAL WORKS

ITEM DESCRIPTION UNIT QTY RATE (RM) AMOUNT (RM)

ELEMENT NO. 8 - SPORT RECREATIONAL …


(Cont'd)

BASKETBALL, TAKRAW AND VOLLEYBALL


COURT … (Cont'd)

Volleyball line

A 50mm wide volleyball court line and marking as ITEM -


specified to manufacturer recommendation,
Architect's detail drawing and S.O. approval

Basketball post

B Approved basketball post overall high 4550mm NO 2 -


consist of 275mm diameter x 10mm thick x
61.9kg/m mild steel pipe as post, 1800mm x
100mm x 25mm thick hardwood buffer board with
angle frame and 1800mm x 1200mm x 1200mm
high concrete footing grade 37 including all
necessary excavation, formwork, reinforcement,
mild steel plate, bolt and nut, net ring and net
and painting works all as per detail drawing and
S.O's approval

Post and net

C Approved 64mm diameter galvanised steel pipe SET 2 -


column as takraw post overall high 1946mm with
approved netting complete with 230mm x 230mm
376 concrete base and 50mm thick lean
concrete all as per detail drawing and S.O's
approval

D Approved 64mm diameter galvanised steel pipe SET 1 -


column as volleyball post

Umpire Stand

E Approved umpire chair/stand in standard size as NO 2 -


manufacturer's recommendation and S.O's
approval

Drainage

F Excavate trench for 600mm wide block drain M 86 -


commencing from formation level, get out, part
return, fill in and compacted with selected
excavated material as specified, temporary
works and struting and remainder deposit,
spread and level as directed depth exceeding
1.00m but not exceeding 2.00m deep

TO COLLECTION -

SMK KOTA WARISAN E/8/11


BILL NO.E - EXTERNAL WORKS

ITEM DESCRIPTION UNIT QTY RATE (RM) AMOUNT (RM)

ELEMENT NO. 8 - SPORT RECREATIONAL …


(Cont'd)

BASKETBALL, TAKRAW AND VOLLEYBALL


COURT … (Cont'd)

A Supply and lay approved 600mm wide precast M 86 -


block drain complete with jointed and filled in
cement and sand (1:3) mortar, concrete base
grade 20, dowel bar, 225mm thick brickwall,
plastering, concrete strut, precast slab cover,
100mm diameter PVC pipe as weephole,
granular bedding and all necessary works
related all as per Engineer's detail drawing and
S.O. approval depth exceeding 1.00m but not
exceeding 2.00m deep

INPRINT CONCRETE FINISH

B Excavate to walkway formation level average M2 713 -


500mm deep commencing from formation level
and remove from site

C 300mm thick (consolidated thickness) of crusher M2 713 -


run as base course consisting laid in layers,
spread, levelled and rolled as specified including
trimming base of excavation

D 50mm thick lean concrete Grade 15 blinding with M2 713 -


surface finished level to receive concrete slab

E 150mm thick concrete slab paver Grade 37 with M2 713 -


double layer of BRC A10 and 5mm thick in-print
finish complete with necessary formwork

Construction Joint

F Allow the forming any construction joint as ITEM -


specified including provision of additional
reinforcement bar, dowel bar, stop board,
formwork, infilled bituminous movement joint,
sleeve and cap etc. and all necessary works in
floor slab where the construction pour sequence
requires the provision of construction and day
joints, all to the approval of the S.O. The method
and the position of construction joint and
waterstops shall approved by the Engineer
before any commencement of related works.

TO COLLECTION -

SMK KOTA WARISAN E/8/12


BILL NO.E - EXTERNAL WORKS

ITEM DESCRIPTION UNIT QTY RATE (RM) AMOUNT (RM)

ELEMENT NO. 8 - SPORT RECREATIONAL …


(Cont'd)

COLLECTION :

From Page E/8/1 . . . -

From Page E/8/2 . . . -

From Page E/8/3 . . . -

From Page E/8/4 . . . -

From Page E/8/5 . . . -

From Page E/8/6 . . . -

From Page E/8/7 . . . -

From Page E/8/8 . . . -

From Page E/8/9 . . . -

From Page E/8/10 . . . -

From Page E/8/11 . . . -

From Page E/8/12 . . . -

TO SUMMARY -

SMK KOTA WARISAN E/8/13