You are on page 1of 1

8 mm # bar @125 mm c/c

8 mm # bar @125 mm c/c 8 mm # bar @125 mm c/c

V
SLAB SECTION AT A-A

BRICK
W2 W2 P.L. P.L. WALL

G.L. G.L.

V 15 NOS 10# BAR


12# BAR@
110 mm c/c
G.L.

BOTH WAY BOTH WAY

W/C W/C

W1
D3 D3 D2 F1 F2 DESIGN OF
DESIGN OF FOOTING WALL FOOTING
SINK

RCC SHELF UPTO SILL

DESIGN OF COLUMN
W1 W1
RCC RACK UPTO LINTEL EXCEPT
WINDOW PORTION RCC SHELF UPTO SILL Name of work:-Model estimate for construction of Pack House.
A A
SPECIFICATIONS:
1. ALL DIMENSIONS ARE IN MM, UNLESS OTHERWISE SPECIFIED.
D1 D1 2. ALL OUTER WALLS ARE OF FULL BRICK MASONRY & ALL PARTITION WALLS
ARE OF HALF BRICK MASONRY WORK.
W1 W1 DESIGN OF ROOF BEAM 3. ALL DOORS EXCEPT TOLET DOORS ARE OF FLUSH DOOR SHUTTER
WITH WOODEN FRAME. TOILET DOORS ARE OF PVC SHUTTER & FRAME
4. ALL WINDOWS ARE OF SLIDING ALUMINIUM FRAME AND SHUTTER WITH
GLASS 4 MM THK. GLASS PANES.
5. VITRIFIED FLOORTILES FOR EQUIPMENT, LAB & A.C. ROOMS, CERAMIC
CANOPY GLAZED TILES FOR TOILET FLOOR AND SHELVES.DADO OF TOILET AND OTHER
ROOMS ARE OF CERAMIC GLAZED WALL TILES.
6. FOR OTHE SPECIFICATION APPROVED ESTIMATE TO BE FOLLOWED
7. BEARING CAPACITY OF SOIL ASSUMED FOR STRUCTURAL DESIGN
= 8.00 T/SQM.
DESIGN OF PLINTH BEAM 8. GRADE OF CONCRETE : M 20(1:1.5:3)
9. GRADE OF STEEL : Fe 415
10. COVERS: a) FOOTING : 50 MM
b) COLUMN : 40 MM
c) BEAM : 30 MM
d) SLAB : 20 MM
11. IF ANY DISCREPENCY ARISES REGARDING DRAWING DURING EXECUTION,
THAT SHOULD BE BROUGHT TO THE NOTICE OF THE APPROVING AUTHORITY.
12. DEVELOPMENT LENGTH MEASUREMENT SHOULD CONFORM TO IS 456 2000
ENTRANCE

DESIGN OF LINTEL