WARNING
This servic e informatio n is designed for experience d repai r technician s only and is not designe d for use by the genera l public.
It doe s not contai n warning s or caution s to advise non-technic al individu als of potentia l dangers in attemptin g to servic e a product.
Product s powered by electricit y shoul d be service d or repaire d only by experience d professiona l technicia ns. Any attemp t to service or
Repai r the produc t or product s deal t with in this servic e infor mation by anyone else could result in seriou s injury or death
1. Introduction............................................................................................ 1
2. Features ................................................................................................ 7
3. Specifications ........................................................................................ 8
4. Sensors list............................................................................................ 9
5. Piping diagrams.....................................................................................10
6. PCB diagram................................................................................... ....11
7. Functions and control ........................................................................... 14
8. Dimensional drawings ........................................................................... 26
9. Center of gravity .................................................................................. 26
10. Service Diagnosis ................................................................................ 27
11. Circuit diagrams .................................................................................. .41
1. Introduction
1.1 Model name explanation
A S 2 6 F B B H R A
DC inverter
Indoor units
Version number
35F Platform
Platform of indoor units: F (F platform)
A S 3 5 F B B H R A
DC inverter
Indoor units
Version number
35F Platform
Platform of indoor units: F (F platform)
Warning
Be sure to disconnect the power cable plug from the plug socket before disassembling the equipment for
a repair.
Working on the equipment that is connected to a power supply can cause an electrical shook.
If it is necessary to supply power to the equipment to conduct the repair or inspecting the circuits, do not
touch any electrically charged sections of the equipment.
If the refrigerant gas discharges during the repair work, do not touch the discharging refrigerant gas .The
refrigerant gas can cause frostbite.
When disconnecting the suction or discharge pipe of the compressor at the welded section, release the
refrigerant gas completely at a well-ventilated place first.
If there is a gas remaining inside the compressor , the refrigerant gas or refrigerating machine oil
discharges when the pipe is disconnected, and it can cause injury.
If the refrigerant gas leaks during the repair work, ventilate the area. The refrigerant gas can generate
toxic gases when it contacts flames.
The step-up capacitor supplies high-voltage electricity to the electrical components of the outdoor unit.
Be sure to discharge the capacitor completely before conducting repair work . A charged capacitor can
cause an electrical shock.
Do not start or stop the air conditioner operation by plugging or unplugging the power cable plug.
Plugging or unplugging the power cable plug to operate the equipment can cause an electrical shock or
fire.
Do not repair the electrical components with wet hands . Working on the equipment with wet hands can
cause an electrical shock
Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical
shock.
Be sure to provide the grounding when repairing the equipment in a humid or wet place, to avoid
electrical
shock.
Be sure to turn off the power switch and unplug the power cable when cleaning the equipment. The
internal fan rotates at a high speed, and cause injury.
Do not tilt the unit when removing it. The water inside the unit can spill and wet the furniture and floor.
Be sure to check that the refrigerating cycle section has cooled down sufficiently before conducting
repair
work. Working on the unit when the refrigerating cycle section is hot can cause burns.
Use the welder in a well-ventilated place. Using the welder in an enclosed room can cause oxygen
deficiency.
Warning
Be sure to use parts listed in the service parts list of the applicable model and appropriate tools to
conduct repair work. Never attempt to modify the equipment. The use of inappropriate parts or tools can
cause an electrical shock, excessive heat generation or fire.
When relocating the equipment, make sure that the new installation site has sufficient strength to
withstand the weight of the equipment.
If the installation site does not have sufficient strength and if the installation work is not conducted
securely, the equipment can fall and cause injury.
Be sure to install the product correctly by using the provided standard installation frame. For
Incorrect use of the installation frame and improper installation can cause the equipment to fall, resulting integral
in injury. units only
For
Be sure to install the product securely in the installation frame mounted on a window frame.
integral
If the unit is not securely mounted, it can fall and cause injury.
units only
Warning
Be sure to use an exclusive power circuit for the equipment, and follow the technical standards related to
the electrical equipment, the internal wiring regulations and the instruction manual for installation when
conducting electrical work.
Insufficient power circuit capacity and improper electrical work can cause an electrical shock or fire.
Be sure to use the specified cable to connect between the indoor and outdoor units. Make the
connections securely and route the cable properly so that there is no force pulling the cable at the
connection terminals.
Improper connections can cause excessive heat generation or fire.
When connecting the cable between the indoor and outdoor units, make sure that the terminal cover
does
not lift off or dismount because of the cable.
If the cover is not mounted properly, the terminal connection section can cause an electrical shock,
excessive heat generation or fire.
Do not damage or modify the power cable.
Damaged or modified power cable can cause an electrical shock or fire. Placing heavy items on the
power cable, and heating or pulling the power cable can damage the cable.
Do not mix air or gas other than the specified refrigerant (R-410A / R22) in the refrigerant system.
If air enters the refrigerating system, an excessively high pressure results, causing equipment damage
and injury.
If the refrigerant gas leaks, be sure to locate the leak and repair it before charging the refrigerant. After .
When replacing the coin battery in the remote controller, be sure to disposed of the old battery to prevent
children from swallowing it.
If a child swallows the coin battery, see a doctor immediately.
Caution
Installation of a leakage breaker is necessary in some cases depending on the conditions of the
installation site, to prevent electrical shocks.
Do not install the equipment in a place where there is a possibility of combustible gas leaks.
If a combustible gas leaks and remains around the unit, it can cause a fire.
Be sure to install the packing and seal on the installation frame properly. If the packing and seal are not
installed properly, water can enter the room and wet the furniture and floor.
Warning
Check to make sure that the power cable plug is not dirty or loose, then insert the plug into a power outlet
all the way.
If the plug has dust or loose connection, it can cause an electrical shock or fire.
If the power cable and lead wires have scratches or deteriorated, be sure to replace them.
Damaged cable and wires can cause an electrical shock, excessive heat generation or fire.
Warning
Do not use a joined power cable or extension cable, or share the same power outlet with other electrical
appliances since it can cause an electrical shock, excessive heat generation or fire.
Caution
Check to see if the parts and wires are mounted and connected properly, and if the connections at the
soldered or crimped terminals are secure. Improper installation and connections can cause excessive
heat generation, fire or an electrical shock.
If the installation platform or frame has corroded, replace it. Corroded installation platform or frame can
cause the unit to fall, resulting in injury.
Check the grounding, and repair it if the equipment is not properly grounded. Improper grounding can
cause an electrical shock.
Be sure to measure the insulation resistance after the repair, and make sure that the resistance is 1 M
ohm or higher.
Faulty insulation can cause an electrical shock.
Be sure to check the drainage of the indoor unit after the repair.
Faulty drainage can cause the water to enter the room and wet the furniture and floor.
2.Features
A-PAM DC inverter:With adoption of S-TYPE,S-PAM and PHASE control technology to works more
Confortable sleep The setting temperature and the indoor noise can be adjusted to a more comfortable
level when you set the “sleep mode” during night sleep.
Super match:One outdoor unit can match two or more indoor unit.
DIY auto mode: Adjust the last fixed operation mode automatically.
Auto restart: Automatic return to previous operation conditions after sudden power blackout
24 hours timer: Use the timer function to set on,or off,or from on to off,or from off to on.
2-way piping design: The pipe can shoot out both from left or right side.
Easy clean design: The panel is easy to wash and the airflow vents can be detached easily
3.Specifications-AS26FBBHRA
Voltage V ~
cooling heating
W 2650(1500-3200) 5700(1600-7700)
Capacity rated
Btu/h 9000(5100-10900) 11200(4400-12200)
Power Consumption(Rated) W 500 650
EER/ COP W/W 5.30 5.08
Moisture Removal m³/h 1.2*10 ³
TECHNICAL SPECIFICATIONS
Motor W 27 30
Fan
Air flow rate(high) m³/h 700
Speed(Hi/Mid/Lo) rpm 1100/925/750 1100/900/700
Note: the data are based on the conditions shown in the table below
Conversation formulae
cooling heating Piping length
Kcal/h= KW×860
Indoor: 27 DB/19 WB Indoor:20 DB
5m Btu/h= KW×3414
Outdoor: 35 DB/24 WB Outdoor: 7 DB/6 WB
cfm=m³/min×35.3
4 Sensors list
type Description Qty
Room and pipe sensor Its used for detecting room and evaporator temperature 1
3.Specifications-AS35FBBHRA
cooling heating
W 3400(1300-4000) 3800(1600-4300)
Capacity rated
Btu/h 11600(4400-13650) 12900(5450-14650)
Power Consumption(Rated) W 780 790
EER/ COP W/W 4.36 4.81
Moisture Removal m³/h 1.6*10 ³
TECHNICAL SPECIFICATIONS
Motor W 32 35
Fan
Air flow rate(high) m³/h 700
Speed(Hi/Mid/Lo) rpm 1100/925/750 1100/900/700
Note: the data are based on the conditions shown in the table below
Conversation formulae
cooling heating Piping length
Kcal/h= KW×860
Indoor: 27 DB/19 WB Indoor:20 DB
5m Btu/h= KW×3414
Outdoor: 35 DB/24 WB Outdoor: 7 DB/6 WB
cfm=m³/min×35.3
4 Sensors list
type Description Qty
Room and pipe sensor Its used for detecting room and evaporator temperature 1
5 Piping diagrams
Filter
Filter
6.PCB diagram
Connectors
PCB(1) (Control PCB)
1) CN9 Connector for fan motor and feedback
2) CN6 Connector for heat exchanger thermistor and Room temperature thermistor
3) CN5’ Connector for UP&DOWN STEP motor
4) CN11 CN11’ Connector for RIGHT&LEFT STEP motor
5) CN21 white line CN52(black line) Connector for indoor terminal N and L
6) CN8 Connector for display board
7) CON2 CON3 Connector for ion generator
8) CN23 (red line) Connector for communicate between the indoor board and the outdoor board
9) CN36 Connector for long-range control
10) CN34 Connector for wifi Module
11) CON1 Connector for fresh air
12) CN2 Connector for wired controller
13) CN51 Connector for room card
AS26/35FBBHRA 0011800593B
AS26/35FBBHRA 0011800387D
PCB
CN11’
CN5 ‘’’
CN5’
CN14
CN51
CN34
CN8
CN2
CN36
CN6
CN15
CN23
CN9
CN21
CN52
sectioon 1
(COOL)
sectioon 2(DRY)
sectioon 3(STOP)
*Defrosting function: preventing the frosting on the indoor heat exchanger (when cooling or
dehumidifying). When the compressor works continuously for 6 minutes and the temperature of the
indoor coils has been below 1ć for 10 seconds, the compressor will be stopped and the malfunction
will be recorded in the malfunction list. The indoor system will continue to run. When the temperature
of the indoor coil is raised to 9ć, the compressor will be restarted again (the requirement of 3 minutes’
delay should be satisfied.)
* Coil protection (synchronic overheating protection) are installed for the four directions latch
malfunctions when dehumidifying.
* Timing system on/off function.
* Dormant control function.
set
37 medium speed 37
35
low speed
35
25
weak speed
25
16
stop
* Residue heat sending. The indoor fan will send the residue heat at a low speed for 20 seconds.
If other conditions are satisfied, when the compressor stops, the indoor system will operate at a light
speed. The indoor fan will stop when the coil temperature is below the THHOT0.
* Defrosting. When the system receives the defrosting signal from outdoors, the indoor fan will stop
and the indoor temperature display won’t change. At the time, any indoor coil malfunctions will be
neglected. When the outdoor defrosting finishes, the coil malfunction will still be neglected until the
compressor has been started up for 30 seconds. The indoor temperature display will not change and
the system operates at the cold air proof mode.
* Automatic heating temperature compensation: when the system enters the heating mode, the
temperature compensation (4ć) will be added. When the status is switched off, the compensation will
be erased.
7.1.7 Timing
You can set 24 hours’ on/off timing accordingly. After the setting, the timing indicator will be lightened.
Also, the light will be turning off after the timing is finished. The followings are several timing methods.
1.system /on timing: The timing indicator will be lightened and the indoor system is under the waiting
mode. The light will be turned off when the timing is finished and the rest of the system will operate
under a normal condition. The timing starts since the last reception of the timing signal.
2.system /off timing: When the system is turned on, the timing indicator is lightened, the rest of the
system will operated under a normal condition. When set time comes, the indicator light will be turned
off and the system will be turned off. If you have set the dormant functions, the order of your settings
will be operated according to the timing settings.
3 .system /on and off timing: The settings will be completed according to the orders..
* Quitting conditions: Press dormant button 10 times within 7 seconds and the buzzer will ring twice.
R25ć=10K¡f2%
B25ć/50ć=3700Kf2%
Temp.((ć)) Max.(K) Normal(K) Min.(K) Tolerance(ć)
Check the power supply. Check to make sure that the rated voltage is supplied.
None of the units
operates
Check the indoor PCB Check to make sure that the indoor PCB is broken
Large operating Check the installation Check to make sure that the required spaces for
noise and condition. installation (specified in the Technical Guide, etc.) are
vibrations provided.
29
30
31
32
33
34
35
36
37
38
39
40
Circuit diagrams
11 Circuit Diagrams
+5V
+5V JP4
4 4-1971798-1-原色-立式
+5V R 94 +5V CN6
PIPE R O O M
R 30 3 J1 1 2
R 29 R 53 100ΩR ST 1K +5V 4 +5V
+5V 2 R OO M R 24 1K
10 K LED 1 R 93 100ΩMOD E 3 D S1 R 86 1K R 42 10 K
C 11 100n F 10 K 1 PIPE R 25 1K
C 46 R 85 2
IC 1 10 K
φ3-红色-散光-低亮 TJC 8-04(立式) C 29 C3 R 28 1 R 49
1 8 10n F R 83 R 27 D S2 R 109 10 K
A0 VC C R 40
2 7 C N1 5 10n F 10n F C 30 4.7u F-1206 1K
A1 W P
4.7K 1%
3-59-C O M M _R X
3-60-C O M M _T X
10 K
4.7K 1%
3 6 1 10 K J2 1 2
A2 SC L 5267 -04A -原色-立式 +5V
4 5 +5V 2 R 74 C 31 4.7u F-1206
GN D SD A 1K N etRG 2
JP3 4 3
M24 C04 N etRG 1
N etL abel243
3-62-N
3 4
N etL abel238
N etL abel239
R 33 560ΩSD A 0.1u F 20
0.%1u-50
F V20 % -50 SW
V 2 机型选择
1
25/35
N etLab el241
ROOM
R 37 10K
10K
10K
FJ-fb
R3 N etRG 2 4 5
zj
A /B
60
59
63
62
61
58
57
56
55
54
53
52
51
50
49
2SA1037A K 2 7 R 103 100n F
100nF
100nF
IC 2
R 96
20 K
R8
在线烧写 1 8
P1 R 5F100LEA F A R 104 2K
10 K B M (ad )
P130(out)
beep0/IN T 6/P140
T O 00/P01
T X D 1/A N 17/P02
beep1/IN T 7/P141
T I00/P00
A V R E FP/A N 0/P20
A V R E FM /A N 1/P21
A N 2/P22
A N 3/P23
A N 4/P24
A N 5/P25
A N 6/P26
A N 7/P27
R 50 D S1 7 39 5 SER
蜂鸣器 P124/XT2 (TXD 0)/TO02/TI02 /P17 RCK R 17 100Ω
3
2K +12 V XT 1 D S2 8 38 6 RCK
P123/XT1 PC LB U Z1/P55 SR C K R 21 100Ω
2 9
N etLab el245 37 7 SR C K
P137/INT 0 P54 IR R 31 1K
10 36 SW ITC H 8 IR
B 10 B-PH -K -S-原色-立式 IC 8 C 15 100n F P122/X2 (INT11 )/P53 R 62 10 K
P76/IN T 10/R X D 2
P77/IN T 11/T X D 2
P30/IN T 3/scl11
P70/K R 0/scl21
1
11 6 D STEP _A VS S IN T1/P50/sda11
P71/sda21
A
P06/T I06
P05/T I05
P73/K R 3
P72/K R 2
1 9 6C 6B E2 14 做相应调整
2 8 B 12
5C 5B
5 D STEP _B TV S 1 C 43 C6 1n F15
EV S S0
C 13 4 D STEP _C 5V/400 W VD D 1K R 73
P63
3 7 4C 4B 100n F 16 R EMOTE_ R X R 34
4 6 D 14
3C 3B
3 D STEP _D 100n F EVDD 0 +5V
15 2 U STEP _A +5V 10 K
5 5 12V 2C 2B 100u F-16 V C 21 +12 V
N etL abel244
N etL abel242
4 1C 1B R 38 10 K R 35
3 B 10n F
C U LN2003A -贴片 R2 10 K N1 D1 5
2 +5V
R 106
SD A
SC L
D JP1 C N3 6
B U ZZ
1 R5 1K zj 2SD1781KT146R 10 K R 43
2 R LS 4148 3
上下摆步进电机 +12 V C 16 N2
1 27Ω-0805 2
C 10 100n F 100n F
TJC 8-02 (立式) KRC119S 1
IC 12
9 8 自检/缩时 R EMOTE_T X 4.7K B 3B -XH -A -蓝色-立式
COM E D1 6
10 7 U STEP _B +5V
左右摆步进电机 7C 7B R 92 R 95 10 K 远程通讯
+12 V 11 6 U STEP _C FK 2K R LS 4148
C N11 'C N1 1 6C 6B
12V 12 5 U STEP _D 10 K R 99 C N5 1
5 5 5C 5B 2K 1
13 4 LS TEP _A
4 4 A 4C 4B 2K 2
14 3 LS TEP _B
3 3 B 3C 3B R 100 B 2B -XH -A -蓝色-立式
2 2 C 15
2C 2B
2 LS TEP _C
C 27
1 1 D 16
1C 1B
1 LS TEP _D 100n F N3 C 12 备注: 1.没有特殊标示下电阻为
R 36 10 K R 101 100n F
B 5B -PH -K -S-原色-立式 IC 3 TLP 421 +5V 10 K 0603 封装,精度为 5 %。
U LN2003A -贴片 房卡
B 5B -PH -K -S-原色-立式 +15 V R 39 1K FJ-fb 2.没有特殊标示下无极性电容为贴片
R 58 2SD1781KT146R 0603 封装,耐压50V ,精度 20 % 。
C 14
C N 9 风机输出 2.7K +5V 3.没有特殊标示下电解电容为85℃。
7 4.7u F-50V -105 ℃ R 60 FJ-pwm
1n F
6 风机反馈
+15 V E14
10n F/630V IC 7 +5V 390Ω C 24 R 88
5 10 K +5V
C X3 6 R 59 10 K
4
R 68 10 K 10n F R 108 R 1 10 K
3 R 57 B 2B -XH -A -R -红色-立式
10 K C N3 4+5V SW ITC H R4 C N1 4
2 10 K
4 GN D
1 +310 V TLP 421 C5 1K 1
C 17 E15 3 R 97 100ΩN ettx SW 1
R 64 TX 100n F 2
10n F 2 RX TS V C -1(5.85*7*7)
B 5P7-XH -A -原色-立式 10 K N etrx
5267 -04A -原色-立式 1
R 98 100Ω 应急开关
47u F-50V -105 ℃-高频 网络通讯
+5V
10 0K -1 /4W
2SD1781KT146R TLP 851/P C851 47K -3W
R 91 100nF -50 V ZD 4
IC 6 1N4746A (18V -1W )
4.7K D1 7 1N 4007 (1000 mA/1000V ) +12 V RED
R 22 N1
R 20 220V_ N L1
3
3-40-COMM _R X 2K -1/4W 100uF -50V -105℃
C N23 ' D4 K2
C 9 1K TLP 421 C Y3
R 19 1 OJE-SS (H )-112 L(D )
1n F 2.2n F-250VAC
10 K D25 0 R LS 4148 ION
1
4
D1 2 R 26 C N2 3
2K -2W C OMM C ON 2
C ON 1
1N 4007 (1000 mA/1000V ) 1
220V_ N 1 ION
C ON 3
L1
+12 V
4
K3
D5 OJE-SS (H )-112 L(D )
R LS 4148
3
L
+ 12 V
+12 V
R 112 +5V IC11 U LN2003 A +12 V
CN2
+ 12 D2 5 2SD1781KT146R R 117 10 K R 44 1K 1 16
WIRE D
4 3-20-FLZ 1B 1C 220V_ N
4
GN D 10 K N4 2 15
3 R 113 2B 2C D1 0
SIG R LS 4148 R 46 1K 3 14
2 R 116 3-29 -TD 3B 3C
R 111 10 K 4 13 K1
1 1K 4B 4C
D2 6 27Ω-0805 R 47 1K 5 12 OJE-SS (H )-112 L(D )
3-5-SW 5B 5C
3
B 4B - C 34 6 11 R 55 0Ω R LS 4148 C OMM
C 25 6B 6C
R 63 1K 7 10
R LS4148
4
KRC119 S
4.7K D1 8
3-25 -LINE-TX 100n F K5
10 K
OJE-SS (H )-112 L( D) N
220V_
3
R LS 4148
ZD00 1
C 013 C 014 R 206
47uF-50V-10 5℃
E9 270 -2W C7
1N 5399 (1500 mA/1000V ) 4.7n F/250V 4.7n F/250V R 004
2.2K N00 1 100n F
+310 V 4 T1 KT C 8050
NTC 1 + 310 V 3
220-L R 205
SC K084 R 72 D7 5 102/1000V 560
10 nF /630V
D6 C 23 6 C 009 R 019
E7 R 78 1
C 002
47K /2W 7
100uF /450V
R 77 47Ω-1/2W
104 -630VDC
1N 53 99(1500m A /1000V )
D00 8
D9 D2 0
D8
D2 1 3000 mA/200V R 209
1N 5399 (1500 mA/1000V ) 1A/1000V 100Ω-1206
C Y1 C Y6
8
7
6
5
4.7n F-250VAC
IC 9 4.7n F-250VAC
ZD20 2
D /ST
D /ST
NC
VCC
A6059 H E204 C 32
22uF-50V-10 5℃
FB
IC 10
S
R 80
1.5K
1
2
3
4
R 61 C 010
TLP 421
1.5Ω-1/2W
1n F
10 uH-2 .5A
+5V
M BR 1100(1A -10 0V )
C N5 2 L2
C 35
1
+12 V 100n F D1 3
LC 1 BLM 21 P G 600 SN 1D
C 40 E6 C 42 C 53
220p F R 65
C N1 7 IC 5 1%
1 E5 R 76 1u F 100n F
C 41
470uF -25V -105℃
1 8 22Ω
D25 0 B OO T PH
2 7
Vin GN D
L1 100n F 3 6 470uF -25V -105 ℃
L FU SE1 EN C OM P
L1
T3.15A 250 V C 13
4
100 K
BALC K C X2 C 26 C3 9 1%
10n F 10p F
~ 22 0VA C 100n F/275V 220p F
2 RV1
CX 1
R 71 R 81
C N2 1 200 K 1%
1
220-N
TV R 14621*620V
2.2nF -250VAC
C Y4 C Y5 C N2 7
1
C N21 ' 1 220V_2.2n
N F-250VAC
D25 0
Haier Group
Haier Industrial Park, No.1, Haier Road Edited by : Zhen Lingyun
Liu Yunlin
266101, Qingdao, China_
Signed by : Zhang Xianqiang
Http //www.haier.com
Approved by: He Shiquan
AS09FBBHRA AS12FBBHRA
AS18FEBHRA AS24FEBHRA
AS26FBBHRA AS35FBBHRA
AS53FEBHRA AS71FEBHRA
Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
Nederlands
Parts and Functions
Indoor Unit Remote controller
Display board
Inlet
(inside) Outer side of the controller
5. ON / OFF button
Inlet grille
8
6. Display of each function
9
status
10 7. Operation mode display
Outlet ON/OFF 7 11
Button 8. WIFI and CLOCK display
Air Purifying Filter Vertical blade 12
(inside) (adjust left and 9. TEMP display
TIMER
right air fl ow) Horizontal flap 13 10. Humidity display
(adjust up and down air flow
6
Don't adjust it manually) 11. FAN SPEED display
5
12. SWING display
Swing up/down display
swing left/right display
14
4 13. TIMER ON display
15 TIMER OFF display
Actual inlet grille may vary from the one shown in the CLOCK display
manual according to the product purchased 3 16
14. FAN button
2 SELF 17
CLEAN
15. QUIET button
1
Display board ECO SENSOR
NOTE:
a. Humidity display is unavailable on some models
Outdoor Unit b. If the model you buy has a WIFI function, press the“ON/OFF”
button for 5s to emit the WIFI binding signal. Once in the
binding mode, the APP will show how to bind.
1
Operation
18. TIMER button Clock set
19. CLOCK button
20. 10 ºC button
1 Press CLOCK button,
2
heating maintaining
(valuable for RS) Press “+” or “-” to set
correct time.
21. HEALTH button
22. SMART button
Used to set SMART
operation. (This function
is unavailable on some Each press will increase or
models.) decrease 1min. If the button is
23. SWING up/down button kept pressed, time will change
24. SWING left/right button quickly.
1 Unit start.
SELF SELF
CLEAN CLEAN
QUIET
You can use this function when silence is needed for rest or
reading.
For each press, is displayed Air conditioner starts
QUIET function operation. In QUIET operation mode, fan
Press the DRY button on the remote controller.
speed automatically takes low speed of AUTO fan mode.
Press QUIET button again, disappears, the operation
stops.
3
Operation
1 button.
SELF
Unit will start running to reach the SELF
CLEAN
ECO SENSOR
CLEAN
temp. setting on LCD.
ECO SENSOR
ECO SENSOR
NOTE :
temperature
automatically.
4
Operation
ECO SENSOR Operation HEALTH AIRFLOW Operation
Human Sensing Function
1. “Follow” function: It can detect where a person is and The setting of
adjust the swing flap accordingly and send air to the
location of this person. If it detects people in two
locations, the swing flap will blow alternatively between function
these two locations and stay at each location for 15s. If
the appliance detects people in three or more locations,
the left and right swing flaps will swing automatically. appears on the display. Avoid
“Avoid” function: When the appliance detects a person in
the body.
TIMER
a location, it will adjust the swing flap to avoid such a
location. If it detects people in three or more locations,
the left and right swing flaps will swing automatically.
Note: again, appears on the display.
1) When there are people in several locations or a
person frequently moves between several locations,if this direct to the body.
person is in the in-between location or the crossing
location, whether the appliance is in a “Follow” mode or
an“Avoid” mode, theswing flap will swing automatically to
send air to these locations. The cancel of
2) Whether the setting is “Follow” or “Avoid”, it takes some
time to adjust theair direction after the appliance identifies function
the location of the people and the air direction will not
change immediately. TORBO
1 Select
mode.
your desired operation
Initial state
TORBO
Initial state
6
Operation
Comfortable SLEEP
3 hours then stops. Temp. is lower than temp. setting
so that room temperature won’t be too high for your
Before going to bed, you can simply press the SLEEP sleep.
button and unit will operate in SLEEP mode and bring you
a sound sleep.
7
Operation
SMART Operation Self Clean Operation
(This function is unavailable on ◆Functional description: the purpose of this function is to
some models)
clean the evaporator.
Entry and exit Press self clean button to enter this
One key can give you a
function, then it will display "CL" on the panel of the indoor
comfortable room! unit and also on the remote controller. After running 20-30
The air conditioning unit can minutes, this function will exit automatically when the " Pi "
judge the indoor temperature and sound is heard twice, then the unit returns to original state.
Under operation process of self clean, pressing the button
humidity, and make the adjustment
repeatedly has no effect and the function will not exit, but
accordingly. pressing the power off button and other mode button can
make it exit.
Note:
1.It has no effect under the mode of timer/sleep.
2.After this mode starts, the air volume may reduce or it
SMART SMART start may even have no airflow.
3.It is normal if the unit makes some noise like expanding
with heat and contracting with coldness.
Press ON/OFF button, unit starts. 4. The “CL” display time may last differently on the remote
Press SMART button “ ” is controller and panel.
5.It is normal if the temperature is below 0℃ outside, the
displayed on the remote controller. unit may display "F25"under this mode running.
TORBO
Please turn off the unit for 10 seconds then restart.
6.The best condition to run this mode: the temperature is
15℃~27℃ and the humidity is 35%~60% in the door,
the temperature is 30℃~40℃(cooling season) and
below 10℃(heating season) out the door.
7.It is hard to frost if the air is too dry(humidity<20%). and
if the humidity is too high(humidity>70%),
the condensate water may increase, which may move away
SMART FRESH
some frost.
SMART Defrost
SMART FAN SPEED
SMART FAN HEALTH
SMART DRY
SMART SOFT
SMART Control temperature
or SMART stops
8
Operation
HEALTH Operation ON/OFF operation and test operation
.
The water-ion generator in the
ON/OFF Operation:
Use this operation only when the remote controller is
airconditioner can generate a lot defective or lost, and with function of emergency running,
of anion effectively balance the air conditioner can run automatically for a while.
When the emergency operation switch is pressed, the
quantity of position and anion in “Pi” sound is heard once, which means the start of this
the air and also to kill bacteria operation.
and speed up the dust sediment
emergency operation starts, the unit will run automatically in
the following modes: Pi
air in the room. Room Designated Timer Fan Operation
temperature temperature mode speed mode
Test operation:
Test operation switch is the same as emergency switch.
For each press, is displayed Use this switch in the test operation
TORBO
when the room temperature is below Pi Pi
Air conditioner starts health anion
16 ºC, do not use it in the normal
function operation. operation.
Continue to press the test operation
switch for more than 5 seconds.
After you hear the “Pi” sound twice,
1
disappears, the operation stops.
9
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room Do not block the air inlet Remote Controller Indoor Body
temperature or outlet
10
Cautions
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.
WARNING
When abnormality such as burnt-small found, Use an exclusive Check proper
immediately stop the operation button and power source installation of the
contact sales shop. with a circuit drainage securely
breaker
Do not start or stop the Do not channel the air flow directly Do not try to repair or Connect the earth
operation by disconnecting at people, especially at infants or reconstruct by yourself.
the aged. cable.
the power supply cord
and so on.
earthing
PROHIBITION PROHIBITION
CAUTION
Do not use for the purpose of storage of Take fresh air occasionally especially Do not operate the switch with
food, art work, precise equipment, when gas appliance is running at the wet hand.
breeding, or cultivation. same time.
STRICT
PROHIBITION ENFORCEMENT PROHIBITION
Do not install the unit near a fireplace Check good condition of the Do not pour water onto the unit
or other heating apparatus. installation stand for cleaning
11
Trouble shooting Cautions
Before asking for service, check the following
Do not obstruct or cover the ventilation grille of the air
first. conditoner.Do not put fingers or any other things into the
inlet/outlet and swing louver.
Phenomenon Cause or check points This appliance is not intended for use by persons (including children)
with reduced physiced, sensory or mental capabilities or lack of
The system When unit is stopped, it won't restart
immediately until 3 minutes have experience and knowledge, unless they have been given supervision
does not restart
immediately. elapsed to protect the system. or instruction concerning use of appliance by person responsible for
When the electric plug is pulled out their safety. Children should be supervised to ensure that they do not
and reinserted, the protection circuit play with the appliance.
will work for 3 minutes to protect the
air conditioner. Specifications
During unit operation or at stop,
The refrigerating circuit is leak-proo f.
a swishing or gurgling noise may
Noise is heard be heard.At first 2-3 minutes after
unit start, this noise is more noticeable.
The machine is adaptive in following situation
(This noise is generated by 1.Applicable ambient temperature range:
refrigerant flowing in the system.)
During unit operation, a cracking Maximum:D.B/W.B 32oC/23oC
noise may be heard.This noise is Indoor Minimum:D.B/W.B 21oC/15oC
generated by the casing expanding
Normal Cooling Maximum:D.B/W.B 46oC/26oC
or shrinking because of
Performance temperature changes. Outdoor Minimum: D.B -20oC
inspection Should there be a big noise from Maximum:D.B 27oC
air flow in unit operation, air Indoor
filter may be too dirty. Minimum: D.B 15oC
Heating
This is because the system Maximum:D.B/W.B 24oC/18oC
Outdoor
Smells are circulates smells from the interior Minimum:D.B/W.B - 7 oC/-8oC
generated. air such as the smell of furniture, o o
paint, cigarettes. Outdoor Maximum:D.B/W.B 24 C/18 C
(INVERTER) Minimum:D.B -15oC
Mist or steam are
blown out. During COOL or DRY operation,
indoor unit may blow out mist. 2. If the power supply cord is damaged, it must be replaced by the
This is due to the sudden cooling manufacturer or its service agent or a similar qualified person.
of indoor air.
3.If the fuse of indoor unit on PC board is broken,please change
it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is
In DRY mode, when room temperature
In dry mode, fan broken,change it with the type of T.25A/250V
becomes lower than temp.
speed can’t be setting+2 oC,unit will run 4. The wiring method should be in line with the local wiring standard.
changed. intermittently at LOW speed
regardless of FAN setting. 5. After installation, the power plug should be easily reached.
Is power plug inserted? 6. The waste battery should be disposed properly.
Is there a power failure?
Is fuse blownout? 7. The appliance is not intended for use by young children or infirm
persons without supervision.
Is the air filter dirty?
Normally it should be cleaned 8. Young children should be supervised to ensure that they do not play
Poor cooling every 15 days.
Multiple with the appliance.
check Are there any obstacles before
inlet and outlet? 9. Please employ the proper power plug, which fit into the power supply
Is temperature set correctly? cord.
Are there some doors or
windows left open? 10. The power plug and connecting cable must have acquired the local
Is there any direct sunlight attestation.
through the window during the
cooling operation?(Use curtain) 11.In order to protect the units,please turn off the A/C first, and at least
Are there too much heat sources 30 seconds later, cutting off the power.
or too many people in the room
during cooling operation?
Haier
Address:No.1 Haier Road,Hi-tech Zone,Qingdao 266101 P.R.China
Contacts: TEL +86-532-8893-6943;FAX +86-532-8893-1010
Website: www.haier.com
12