SERVICE MANUAL

Wall Mounted Type


DC Inverter
Model No. AS26FBBHRA
AS35FBBHRA

WARNING
This servic e informatio n is designed for experience d repai r technician s only and is not designe d for use by the genera l public.
It doe s not contai n warning s or caution s to advise non-technic al individu als of potentia l dangers in attemptin g to servic e a product.
Product s powered by electricit y shoul d be service d or repaire d only by experience d professiona l technicia ns. Any attemp t to service or
Repai r the produc t or product s deal t with in this servic e infor mation by anyone else could result in seriou s injury or death

(Qing dao Haie r Air Condi tioner Genera l corp . , Ltd)


All right s reser ved. Unauthoriz ed copying and distributio n is a violati on of law

Haier Group Version V1 Date 2018-07-02


Table of contents
Contents

1. Introduction............................................................................................ 1
2. Features ................................................................................................ 7
3. Specifications ........................................................................................ 8
4. Sensors list............................................................................................ 9
5. Piping diagrams.....................................................................................10
6. PCB diagram................................................................................... ....11
7. Functions and control ........................................................................... 14
8. Dimensional drawings ........................................................................... 26
9. Center of gravity .................................................................................. 26
10. Service Diagnosis ................................................................................ 27
11. Circuit diagrams .................................................................................. .41

Domestic air conditioner


Introduction

1. Introduction
1.1 Model name explanation

A S 2 6 F B B H R A

Apply toT1; 220~240V/50Hz/1Ph

DC inverter

Indoor units
Version number

35F Platform
Platform of indoor units: F (F platform)

Nominal cooling capacity (26 00W )

Type of indoor unit: S (wall-mounted)


Indoor unit

A S 3 5 F B B H R A

Apply toT1; 220~240V50Hz/1Ph

DC inverter

Indoor units
Version number

35F Platform
Platform of indoor units: F (F platform)

Nominal cooling capacity (3500W )

Type of indoor unit: S (wall-mounted)


Indoor unit

Domestic air conditioner


Introduction

1.2 Safety Cautions


Be sure to read the following safety cautions before conducting repair work.
The caution items are classified into “Warning” and “Caution”. The “Warning” items are especially important
since they can lead to death or serious injury if they are not followed closely. The “Caution” items can also lead
to serious accidents under some conditions if they are not followed. Therefore, be sure to observe all the safety
caution items described below.
About the pictograms
This symbol indicates an item for which caution must be exercised.
The pictogram shows the item to which attention must be paid.
This symbol indicates a prohibited action.
The prohibited item or action is shown inside or near the symbol.
This symbol indicates an action that must be taken, or an instruction.
The instruction is shown inside or near the symbol.
After the repair work is complete, be sure to conduct a test operation to ensure that the equipment operates
Normally, and explain the cautions for operating the product to the customer.

1.2.1 Caution in Repair

Warning
Be sure to disconnect the power cable plug from the plug socket before disassembling the equipment for
a repair.
Working on the equipment that is connected to a power supply can cause an electrical shook.
If it is necessary to supply power to the equipment to conduct the repair or inspecting the circuits, do not
touch any electrically charged sections of the equipment.

If the refrigerant gas discharges during the repair work, do not touch the discharging refrigerant gas .The
refrigerant gas can cause frostbite.

When disconnecting the suction or discharge pipe of the compressor at the welded section, release the
refrigerant gas completely at a well-ventilated place first.
If there is a gas remaining inside the compressor , the refrigerant gas or refrigerating machine oil
discharges when the pipe is disconnected, and it can cause injury.

If the refrigerant gas leaks during the repair work, ventilate the area. The refrigerant gas can generate
toxic gases when it contacts flames.

The step-up capacitor supplies high-voltage electricity to the electrical components of the outdoor unit.
Be sure to discharge the capacitor completely before conducting repair work . A charged capacitor can
cause an electrical shock.
Do not start or stop the air conditioner operation by plugging or unplugging the power cable plug.
Plugging or unplugging the power cable plug to operate the equipment can cause an electrical shock or
fire.

2 Domestic air conditioner


Introduction
Warning

Do not repair the electrical components with wet hands . Working on the equipment with wet hands can
cause an electrical shock

Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical
shock.

Be sure to provide the grounding when repairing the equipment in a humid or wet place, to avoid
electrical
shock.

Be sure to turn off the power switch and unplug the power cable when cleaning the equipment. The
internal fan rotates at a high speed, and cause injury.

Do not tilt the unit when removing it. The water inside the unit can spill and wet the furniture and floor.

Be sure to check that the refrigerating cycle section has cooled down sufficiently before conducting
repair
work. Working on the unit when the refrigerating cycle section is hot can cause burns.

Use the welder in a well-ventilated place. Using the welder in an enclosed room can cause oxygen
deficiency.

1.2.2 Cautions Regarding Products after Repair

Warning
Be sure to use parts listed in the service parts list of the applicable model and appropriate tools to
conduct repair work. Never attempt to modify the equipment. The use of inappropriate parts or tools can
cause an electrical shock, excessive heat generation or fire.
When relocating the equipment, make sure that the new installation site has sufficient strength to
withstand the weight of the equipment.
If the installation site does not have sufficient strength and if the installation work is not conducted
securely, the equipment can fall and cause injury.
Be sure to install the product correctly by using the provided standard installation frame. For
Incorrect use of the installation frame and improper installation can cause the equipment to fall, resulting integral
in injury. units only
For
Be sure to install the product securely in the installation frame mounted on a window frame.
integral
If the unit is not securely mounted, it can fall and cause injury.
units only

3 Domestic air conditioner


Introduction

Warning

Be sure to use an exclusive power circuit for the equipment, and follow the technical standards related to
the electrical equipment, the internal wiring regulations and the instruction manual for installation when
conducting electrical work.
Insufficient power circuit capacity and improper electrical work can cause an electrical shock or fire.

Be sure to use the specified cable to connect between the indoor and outdoor units. Make the
connections securely and route the cable properly so that there is no force pulling the cable at the
connection terminals.
Improper connections can cause excessive heat generation or fire.

When connecting the cable between the indoor and outdoor units, make sure that the terminal cover
does
not lift off or dismount because of the cable.
If the cover is not mounted properly, the terminal connection section can cause an electrical shock,
excessive heat generation or fire.
Do not damage or modify the power cable.
Damaged or modified power cable can cause an electrical shock or fire. Placing heavy items on the
power cable, and heating or pulling the power cable can damage the cable.

Do not mix air or gas other than the specified refrigerant (R-410A / R22) in the refrigerant system.
If air enters the refrigerating system, an excessively high pressure results, causing equipment damage
and injury.

If the refrigerant gas leaks, be sure to locate the leak and repair it before charging the refrigerant. After .

charging refrigerant, make sure that there is no refrigerant leak.


If the leak cannot be located and the repair work must be stopped, be sure to perform pump-down and
close the service valve, to prevent the refrigerant gas from leaking into the room. The refrigerant gas
itself
is harmless, but it can generate toxic gases when it contacts flames, such as fan and other heaters,
stoves and ranges.

When replacing the coin battery in the remote controller, be sure to disposed of the old battery to prevent
children from swallowing it.
If a child swallows the coin battery, see a doctor immediately.

4 Domestic air conditioner


Introduction

Caution

Installation of a leakage breaker is necessary in some cases depending on the conditions of the
installation site, to prevent electrical shocks.

Do not install the equipment in a place where there is a possibility of combustible gas leaks.
If a combustible gas leaks and remains around the unit, it can cause a fire.

Be sure to install the packing and seal on the installation frame properly. If the packing and seal are not
installed properly, water can enter the room and wet the furniture and floor.

1.2.3 Inspection after Repair

Warning

Check to make sure that the power cable plug is not dirty or loose, then insert the plug into a power outlet
all the way.
If the plug has dust or loose connection, it can cause an electrical shock or fire.

If the power cable and lead wires have scratches or deteriorated, be sure to replace them.
Damaged cable and wires can cause an electrical shock, excessive heat generation or fire.

Warning

Do not use a joined power cable or extension cable, or share the same power outlet with other electrical
appliances since it can cause an electrical shock, excessive heat generation or fire.

5 Domestic air conditioner


Introduction

Caution
Check to see if the parts and wires are mounted and connected properly, and if the connections at the
soldered or crimped terminals are secure. Improper installation and connections can cause excessive
heat generation, fire or an electrical shock.
If the installation platform or frame has corroded, replace it. Corroded installation platform or frame can
cause the unit to fall, resulting in injury.

Check the grounding, and repair it if the equipment is not properly grounded. Improper grounding can
cause an electrical shock.

Be sure to measure the insulation resistance after the repair, and make sure that the resistance is 1 M
ohm or higher.
Faulty insulation can cause an electrical shock.
Be sure to check the drainage of the indoor unit after the repair.
Faulty drainage can cause the water to enter the room and wet the furniture and floor.

1.2.4 Using Icons


Icons are used to attract the attention of the reader to specific information. The meaning of each icon is described in
the table below:

1.2.5 Using Icons List

Icon Type of Information Description

A “note” provides information that is not indispensable, but may


Note
Note nevertheless be valuable to the reader, such as tips and tricks.

A “caution” is used when there is danger that the reader, through


incorrect manipulation, may damage equipment, loose data, get
Caution
Caution an
unexpected result or has to restart (part of) a procedure.

Warning A “warning” is used when there is danger of personal injury.


Warning

A “reference” guides the reader to other places in this binder or in


Reference this manual, where he/she will find additional information on a
specific topic.

6 Domestic air conditioner


Features

2.Features

Super quiet: Lower noise operation condition

A-PAM DC inverter:With adoption of S-TYPE,S-PAM and PHASE control technology to works more

stably at low-frequency,and is more energy-saving,mor powerful at high frequency.

Long distance air supplying: The furthest air distance is 12 meters.

-15 Heating: When -15 can still heating natural

10 heating maintenance:Heating Holding 10 temperature

Confortable sleep The setting temperature and the indoor noise can be adjusted to a more comfortable

level when you set the “sleep mode” during night sleep.

Super match:One outdoor unit can match two or more indoor unit.

DIY auto mode: Adjust the last fixed operation mode automatically.

Turbo mode: Quick cooling or heating

Auto restart: Automatic return to previous operation conditions after sudden power blackout

24 hours timer: Use the timer function to set on,or off,or from on to off,or from off to on.

Intergrative valve cover:The valve cover is Intergrative.

2-way piping design: The pipe can shoot out both from left or right side.

Easy clean design: The panel is easy to wash and the airflow vents can be detached easily

Double 8 display:The display is Double 8 mode.

7 Domestic air conditioner


Specifications

3.Specifications-AS26FBBHRA

NOMINAL DISTRIBUTION SYSTEM VOLTAGE


Phase / 1
Frequency Hz 50

Voltage V ~

NOMINAL CAPACITY and NOMINAL INPUT

cooling heating
W 2650(1500-3200) 5700(1600-7700)
Capacity rated
Btu/h 9000(5100-10900) 11200(4400-12200)
Power Consumption(Rated) W 500 650
EER/ COP W/W 5.30 5.08
Moisture Removal m³/h 1.2*10 ³

TECHNICAL SPECIFICATIONS

Dimensions H*W*D mm 870×301×196


Packaged Dimensions H*W*D mm 952×389×283
Weight / KG 10.1
Gross weight / KG 12.5
Color / / White
Sound
dB(A) 39/33/28 39/33/28
Sound level peessure(Hi/Mid/Lo)
Sound power(high) dB(A) 60 60

Domestic air conditioner


Specifications
TECHNICAL SPECIFICATIONS-PARTS
cooling heating
Type Cross flow fan

Motor W 27 30
Fan
Air flow rate(high) m³/h 700
Speed(Hi/Mid/Lo) rpm 1100/925/750 1100/900/700

Type ML fin- 7HI-HX tube


Heat exchanger
Segment *stage*fitch 3*16*1.4
Air direction control Right,Left,Horizontal,Downward
Air filter Removable/Washable/Mildew Proof
Temperature control Microcomputer Control
Remote controller model 0010402886AD

Note: the data are based on the conditions shown in the table below
Conversation formulae
cooling heating Piping length
Kcal/h= KW×860
Indoor: 27 DB/19 WB Indoor:20 DB
5m Btu/h= KW×3414
Outdoor: 35 DB/24 WB Outdoor: 7 DB/6 WB
cfm=m³/min×35.3

4 Sensors list
type Description Qty

Room and pipe sensor Its used for detecting room and evaporator temperature 1

Domestic air conditioner


Specifications

3.Specifications-AS35FBBHRA

NOMINAL DISTRIBUTION SYSTEM VOLTAGE


Phase / 1
Frequency Hz 50
Voltage V ~

NOMINAL CAPACITY and NOMINAL INPUT

cooling heating
W 3400(1300-4000) 3800(1600-4300)
Capacity rated
Btu/h 11600(4400-13650) 12900(5450-14650)
Power Consumption(Rated) W 780 790
EER/ COP W/W 4.36 4.81
Moisture Removal m³/h 1.6*10 ³

TECHNICAL SPECIFICATIONS

Dimensions H*W*D mm 870×301×196


Packaged Dimensions H*W*D mm 952×389×283
Weight / KG 10.1
Gross weight / KG 12.5
Color / / White
Sound
dB(A) 40/38/35 40/38/35
Sound level peessure(Hi/Mid/Lo)
Sound power(high) dB(A) 61 61

Domestic air conditioner


Specifications
TECHNICAL SPECIFICATIONS-PARTS
cooling heating
Type Cross flow fan

Motor W 32 35
Fan
Air flow rate(high) m³/h 700
Speed(Hi/Mid/Lo) rpm 1100/925/750 1100/900/700

Type ML fin- 7HI-HX tube


Heat exchanger
Segment *stage*fitch 3*16*1.4
Air direction control Right,Left,Horizontal,Downward
Air filter Removable/Washable/Mildew Proof
Temperature control Microcomputer Control
Remote controller model 0010402886AD

Note: the data are based on the conditions shown in the table below
Conversation formulae
cooling heating Piping length
Kcal/h= KW×860
Indoor: 27 DB/19 WB Indoor:20 DB
5m Btu/h= KW×3414
Outdoor: 35 DB/24 WB Outdoor: 7 DB/6 WB
cfm=m³/min×35.3

4 Sensors list
type Description Qty

Room and pipe sensor Its used for detecting room and evaporator temperature 1

Domestic air conditioner


Piping diagrams

5 Piping diagrams

Filter

Filter

 Domestic air conditioner


Printed circuit board connector wiring diagram

6.PCB diagram
Connectors
PCB(1) (Control PCB)
1) CN9 Connector for fan motor and feedback
2) CN6 Connector for heat exchanger thermistor and Room temperature thermistor
3) CN5’ Connector for UP&DOWN STEP motor
4) CN11 CN11’ Connector for RIGHT&LEFT STEP motor
5) CN21 white line CN52(black line) Connector for indoor terminal N and L
6) CN8 Connector for display board
7) CON2 CON3 Connector for ion generator
8) CN23 (red line) Connector for communicate between the indoor board and the outdoor board
9) CN36 Connector for long-range control
10) CN34 Connector for wifi Module
11) CON1 Connector for fresh air
12) CN2 Connector for wired controller
13) CN51 Connector for room card

Note: Other designations


PCB(1) (Indoor Control PCB)
1) CN14 Connector for Forced operation ON / OFF switch
2) FUSE1 Fuse 3.15A/250VAC

AS26/35FBBHRA 0011800593B

AS26/35FBBHRA 0011800387D

11 Domestic air conditioner


Printed circuit board connector wiring diagram

PCB

CN11’
CN5 ‘’’
CN5’

CN14

CN51
CN34

CN8

CN2

CN36

CN6

CN15

CN23

CN9

CN21

CN52

12 Domestic air conditioner


Printed circuit board connector wiring diagram

3 Domestic air conditioner


Functions and control

7.Funcitions and control


7.1 Main functions and control specification
7.1.1 Automatic operation
When the running mode is turned to automation after starting the system, the system will first
determine the running mode according to the current room temperature and then will run according to
the determined mode. Tr in the following selection conditions means room temperature, Ts means
setting temperature, Tp means temperature of indoor coil pipe
TrıTs-3ć Choose Cooling Mode
Tr˘Ts-3ć Choose Heating Mode
After turning to the automation mode, the running mode can be switched between cooling mode,
fan mode and heating mode according to the change of the indoor ambient temperature. But the
automatic conversion between cooling mode and heating mode must be conducted after 15 minutes.

7.1.2 Cooling operation mode


Temperature control range: 16ć---30ć
Temperature difference: r1ć
* Control features: When Tr˄input airflow˅>Ts˄set temperature˅+ temperature Backlash A, the
compressor will be opened, the indoor fan will operate at the set speed and the mode signal will be
sent to the outdoor system. When Tr˄input airflow˅ Ts˄set temperature˅ temperature Backlash
B, the compressor will be shutted, the indoor fan will operate at the set speed and the mode signal will
be sent to the outdoor system. The system will keep the original status if Tr= Ts.
Airflow speed control: (temperature difference 1ć)
Automatic: When TrTs+3ć, high speed.
When Ts+1ćTr<Ts+3ć, medium speed
When Tr<Ts+1ć, low speed
When the sensor is off, low speed
When the airflow speed has no delay from the high to low switching, the speed should be delayed for
3 minutes (remain at high speed for 3 minutes.) before the next switch.
Manus: When the system is operating, you can set the high, medium or low speed manually. (When
the sensor is on or off, the system will change the speed 2 seconds after receiving the signal.)
*Airgate location control: the location for the airgate can be set according to your needs.
*Defrosting function: preventing the frosting on the indoor heat exchanger (when cooling or
dehumidifying). When the compressor works continuously for 6 minutes and the temperature of the
indoor coils has been below one centigrade for 10 seconds, the compressor will be stopped and the
malfunction will be recorded in the malfunction list. The indoor system will continue to run. When the
temperature of the indoor coil is raised to 9ć, the compressor will be restarted again (the requirement
of 3 minutes’ delay should be satisfied.)
* timing system on/off function.
* Dormant control function.

14 Domestic air conditioner


Functions and control

7.1.3 Dry mode.


* temperature control range: 16---30ć
* temperature difference: r1ć
Control feature: send the dehumidifying signal to the outdoor system.
When Tr>Ts+2ć, the compressor will be turned on, the indoor fan will operate at the set speed.
When Tr is between the Ts and Ts+2ć, the outdoor system will operate at the high dehumidifying
frequency for 10 minutes and then at the low dehumidifying mode for six minutes. The indoor fan will
operate at low speed.
When Tr< Ts-1.5ć, the outsystem will be stopped, the indoor fan will be stopped for 3 minutes and
then turned to the low speed option.
All the frequency converses have a f1ć difference.

sectioon 1
(COOL)

sectioon 2(DRY)

sectioon 3(STOP)

* Wind speed control: Automatic:


When Tr Ts+ 5ć, high speed.
When Ts+3ćdTr< Ts+5ć, medium speed.
When Ts+2ćdTr< Ts+3ć, low speed.
When Tr<Ts+2ć, light speed.
If the outdoor fan stopped, the indoor fan will be paused for 3 minutes.
If the outdoor fan stopped for more than 3 minutes and the outdoor system still operates, the system
will be changed into light speed mode.
When the airflow speed has no delay from the high to low switching, the speed should be delayed for
3 minutes (remain at high speed for 3 minutes.) before the next switch.
Manual: When the sensor is off or Tr< Ts+3ć, the manual operation can not be made. (obligatory
automatic operation.)
*Airgate location control: the location for the airgate can be set according to your needs.

15 Domestic air conditioner


Functions and control

*Defrosting function: preventing the frosting on the indoor heat exchanger (when cooling or
dehumidifying). When the compressor works continuously for 6 minutes and the temperature of the
indoor coils has been below 1ć for 10 seconds, the compressor will be stopped and the malfunction
will be recorded in the malfunction list. The indoor system will continue to run. When the temperature
of the indoor coil is raised to 9ć, the compressor will be restarted again (the requirement of 3 minutes’
delay should be satisfied.)
* Coil protection (synchronic overheating protection) are installed for the four directions latch
malfunctions when dehumidifying.
* Timing system on/off function.
* Dormant control function.

7.1.4 Heating operation mode.


* temperature control range: 16---30ć
* temperature difference: r1ć
* control feature: the temperature compensation is automatically added and the system will send the
heating signals to the outdoor system.
If Tr+0.5ćdTs, the outdoor compressor is turned on, the indoor fan will be at the cold air proof mode.
If Tr>Ts+1.5ć, the outdoor system is turned off, the indoor fan will be at the heat residue sending
mode.
*Indoor fan control
manual control: You can choose high, medium, low and automatic speed control.
Automatic: When Tr<Ts, high speed.
When TsTrTs+2ć, medium speed.
When Tr> Ts+2ć, low speed.
When the airflow speed has no delay from the high to low switching, the speed should be delayed for
3 minutes (remain at high speed for 3 minutes.) before the next switch.
*Airgate location control: the location for the airgate can be set according to your needs.
Coldair proof operation
1. The fan control functions as below:


set

37 medium speed 37

35
low speed
35
25
weak speed
25
16
stop

16 Domestic air conditioner


Functions and control


* Residue heat sending. The indoor fan will send the residue heat at a low speed for 20 seconds.
If other conditions are satisfied, when the compressor stops, the indoor system will operate at a light
speed. The indoor fan will stop when the coil temperature is below the THHOT0.
* Defrosting. When the system receives the defrosting signal from outdoors, the indoor fan will stop
and the indoor temperature display won’t change. At the time, any indoor coil malfunctions will be
neglected. When the outdoor defrosting finishes, the coil malfunction will still be neglected until the
compressor has been started up for 30 seconds. The indoor temperature display will not change and
the system operates at the cold air proof mode.
* Automatic heating temperature compensation: when the system enters the heating mode, the
temperature compensation (4ć) will be added. When the status is switched off, the compensation will
be erased.

7.1.5 Turbo function


The system enters the mode after receiving the ‘strength signal’.
Send strength operation signal to the outdoor system.
The mode change finishes the strength operation.
Entering ‘mute’, you can have normal operation or signal control such as timing to finish the strength
operation.
When the system is at the automatic option with the strength/ mute function, if the system enters the
cooling mode, the cooling strength/ mute function will be offered; if the system enters the heating
mode, then the heating strength/ mute function will be offered; if the system enters the airflow mode,
there will be no strength/ mute function.

7.1.6 quiet function


The system enters the mode after receiving the ‘mute signal’.
a. Mute heating: the airflow speed is slight, the system sends the mute signal to the outdoor system.
b. mute cooling: the airflow speed is slight, the system sends the mute signal to the outdoor system.
When the compressor operates, the airflow speed is mute speed. EEPROM is adaptable.
Mute operation can not work under the dehumidifying and airflow-sending operation.

17 Domestic air conditioner


Functions and control

7.1.7 Timing
You can set 24 hours’ on/off timing accordingly. After the setting, the timing indicator will be lightened.
Also, the light will be turning off after the timing is finished. The followings are several timing methods.
1.system /on timing: The timing indicator will be lightened and the indoor system is under the waiting
mode. The light will be turned off when the timing is finished and the rest of the system will operate
under a normal condition. The timing starts since the last reception of the timing signal.
2.system /off timing: When the system is turned on, the timing indicator is lightened, the rest of the
system will operated under a normal condition. When set time comes, the indicator light will be turned
off and the system will be turned off. If you have set the dormant functions, the order of your settings
will be operated according to the timing settings.
3 .system /on and off timing: The settings will be completed according to the orders..

7.1.8 sleeping function


The dormant timing is an eight hours unadaptable one. The timing signs are shown on the V series
board. (RC series show the dormant signal, the timing light is lighted on the 6 lights board).
2.1 Under the cooling/ dehumidifying operation, after the setting of the dormant operation, the set
temperature will be raised for 1 centigrade after 1 hour’s operation and will be raised for 1 centigrade
1 hour later. The system will keep this status for 6 hours and then close.
2.2 Under the heating mode, after the setting of the dormant operation, the setting temperature will fall
2 centigrade after 1 hour’s operation and will fall 2 centigrade 1 hour later. 3 hours after the preceding
operations, the set temperature will be raised for 1 centigrade and the system will keep this status for
3 hours and then close down.
2.3 During the dormant time, except the change of the system mode or a new press on the dormant
setting keys, the timing of the 8 hours dormancy will take the first timing as the start time, any presses
on other keys will not affect the original timing.
2.4 Indoor fan control under the dormant operation.
If the indoor fan is at the high speed before the dormant operation setting, the speed will be turned to
medium after the setting. If the fan is at the medium speed before the dormant setting, the speed will
be turned to low after the setting. If the fan is at the low speed before the dormant setting, the speed
will not change.

18 Domestic air conditioner


Functions and control

7.1.9 emergency switch function


Press the urgency button the buzzer will ring. The system will enter the automatic mode if you don’t
press the button for more than 5 seconds.
Under the system off mode, if you press the urgency key for 5 to 10 seconds, the system will start the
test operation.
Under the system off mode, if you press the urgency key for 10 to 15 seconds, the display screen will
show the resume of the last malfunction.
If the system is under operation, the press on the urgency key will stop it.
Under the system off mode, the display screen will show automatic running sign.
Under the system off mode, the system will not receive the remote control signal if the press on the
urgency key doesn’t last for 15 seconds or if the key is loosened.
Urgency operation: If you press the urgency key for less than 5 seconds, the buzzer will ring when you
press the on/off key. The system will enter the urgency operation when the urgency key is loosened.
The urgency operation is fully automatic.
Test operation.
The inlet temperature sensor doesn’t work, the indoor fan and the indoor air direction board motor
works synchronically. High speed airflow, cooling, outdoor system on, etc, will send the ambient
temperature 30 centigrade and coil temperature 16 centigrade information to the outdoor system.
Test operation
The defrost protection of the evaporator doesn’t work.
The temperature control doesn’t work.
The test operation will be finished in 30 minutes.
The test operation can be stopped by the relative commands from the remote control.

19 Domestic air conditioner


Functions and control

7.1.10 Low load protection control


In order to prevent the frosting of the indoor evaporator, the outdoor system will be
stopped if the indoor heat interaction temperature is below 1ć centigrade for 5 minutes, but the fan
will continue to operate. The outdoor system will be started again when the heat interaction
temperature is above 9 centigrade and the system has been stopped for 3 minutes. The malfunction
will be stored in the malfunction resume and will not be revealed

7.1.11 High load protection control


The outdoor system will be stopped if the coil temperature is above 63ć for 2 minutes. The indoor
fan will be controlled by the thermostat. The outdoor system can be restarted when the coil
temperature is below 45ć and the system has been stopped for 3 minutes. The malfunction will be
stored in the malfunction resume and will not be revealed.

7.1.12 Single indoor system operation


* Enter condition: First, set the high speed airflow and 30 centigrade set temperature, then press the
dormant keys for 6 times within 7 seconds, the system will feedback with 6 rings.
* After the system enters the separate indoor system operation mode, the indoor system will operate
according to the set mode and neglect the communication signals of the outdoor system. However, it
has to send signals to the outdoor system.
* Quitting condition: This mode can be quitted after receiving the quitting signal from the remote
control or urgency system. The indoor system thus can quit the single operation mode.

7.1.13 Auto restarted function


* Entering condition: Press sleep button 10 times within 7 second, the buzzer will ring 4 times

* Quitting conditions: Press dormant button 10 times within 7 seconds and the buzzer will ring twice.

20 Domestic air conditioner


Functions and control

7.2 Value of thermistor


Room sensor and Pipe Sensor

R25ć=10K¡f2%
B25ć/50ć=3700Kf2%
Temp.((ć)) Max.(K) Normal(K) Min.(K) Tolerance(ć)

-30 165.2170 147.9497 132.3678 -1.94 1.75

-29 155.5754 139.5600 125.0806 -1.93 1.74

-28 146.5609 131.7022 118.2434 -1.91 1.73

-27 138.1285 124.3392 111.8256 -1.89 1.71

-26 130.2371 117.4366 105.7989 -1.87 1.70

-25 122.8484 110.9627 100.1367 -1.85 1.69

-24 115.9272 104.8882 94.8149 -1.83 1.67

-23 109.4410 99.1858 89.8106 -1.81 1.66

-22 103.3598 93.8305 85.1031 -1.80 1.64

-21 97.6556 88.7989 80.6728 -1.78 1.63

-20 92.3028 84.0695 76.5017 -1.76 1.62

-19 87.2775 79.6222 72.5729 -1.74 1.60

-18 82.5577 75.4384 68.8710 -1.72 1.59

-17 78.1230 71.5010 65.3815 -1.70 1.57

-16 73.9543 67.7939 62.0907 -1.68 1.55

-15 70.0342 64.3023 58.9863 -1.66 1.54

-14 66.3463 61.0123 56.0565 -1.64 1.52

-13 62.8755 57.9110 53.2905 -1.62 1.51

-12 59.6076 54.9866 50.6781 -1.60 1.49

-11 56.5296 52.2278 48.2099 -1.58 1.47

-10 53.6294 49.6244 45.8771 -1.56 1.46

-9 50.8956 47.1666 43.6714 -1.54 1.44

-8 48.3178 44.8454 41.5851 -1.51 1.42

-7 45.8860 42.6525 39.6112 -1.49 1.40

-6 43.5912 40.5800 37.7429 -1.47 1.39

-5 41.4249 38.6207 35.9739 -1.45 1.37

-4 39.3792 36.7676 34.2983 -1.43 1.35

-3 37.4465 35.0144 32.7108 -1.41 1.33

-2 35.6202 33.3552 31.2062 -1.38 1.31

-1 33.8936 31.7844 29.7796 -1.36 1.29

0 32.2608 30.2968 28.4267 -1.34 1.28

1 30.7162 28.8875 27.1431 -1.32 1.26

2 29.2545 27.5519 25.9250 -1.29 1.24

3 27.8708 26.2858 24.7686 -1.27 1.22

4 26.5605 25.0851 23.6704 -1.25 1.20

5 25.3193 23.9462 22.6273 -1.23 1.18

6 24.1432 22.8656 21.6361 -1.20 1.16

22 Domestic air conditioner


Functions and control

7 23.0284 21.8398 20.6939 -1.18 1.14

8 21.9714 20.8659 19.7982 -1.15 1.12

9 20.9688 19.9409 18.9463 -1.13 1.09

10 20.0176 19.0621 18.1358 -1.11 1.07

11 19.1149 18.2270 17.3646 -1.08 1.05

12 18.2580 17.4331 16.6305 -1.06 1.03

13 17.4442 16.6782 15.9315 -1.03 1.01

14 16.6711 15.9601 15.2657 -1.01 0.99

15 15.9366 15.2770 14.6315 -0.98 0.96

16 15.2385 14.6268 14.0271 -0.96 0.94

17 14.5748 14.0079 13.4510 -0.93 0.92

18 13.9436 13.4185 12.9017 -0.91 0.90

19 13.3431 12.8572 12.3778 -0.88 0.87

20 12.7718 12.3223 11.8780 -0.86 0.85

21 12.2280 11.8126 11.4011 -0.83 0.83

22 11.7102 11.3267 10.9459 -0.81 0.80

23 11.2172 10.8634 10.5114 -0.78 0.78

24 10.7475 10.4216 10.0964 -0.75 0.75

25 10.3000 10.0000 9.7000 -0.75 0.75

26 9.8975 9.5974 9.2980 -0.76 0.76

27 9.5129 9.2132 8.9148 -0.80 0.80

28 9.1454 8.8465 8.5496 -0.84 0.83

29 8.7942 8.4964 8.2013 -0.87 0.86

30 8.4583 8.1621 7.8691 -0.91 0.90

31 8.1371 7.8428 7.5522 -0.95 0.93

32 7.8299 7.5377 7.2498 -0.98 0.97

33 7.5359 7.2461 6.9611 -1.02 1.00

34 7.2546 6.9673 6.6854 -1.06 1.04

35 6.9852 6.7008 6.4222 -1.10 1.07

36 6.7273 6.4459 6.1707 -1.13 1.11

37 6.4803 6.2021 5.9304 -1.17 1.14

38 6.2437 5.9687 5.7007 -1.21 1.18

39 6.0170 5.7454 5.4812 -1.25 1.22

40 5.7997 5.5316 5.2712 -1.29 1.25

41 5.5914 5.3269 5.0704 -1.33 1.29

42 5.3916 5.1308 4.8783 -1.37 1.33

43 5.2001 4.9430 4.6944 -1.41 1.36

44 5.0163 4.7630 4.5185 -1.45 1.40

45 4.8400 4.5905 4.3500 -1.49 1.44

46 4.6708 4.4252 4.1887 -1.53 1.47

47 4.5083 4.2666 4.0342 -1.57 1.51

48 4.3524 4.1145 3.8862 -1.61 1.55

49 4.2026 3.9686 3.7443 -1.65 1.59

23 Domestic air conditioner


Functions and control

50 4.0588 3.8287 3.6084 -1.70 1.62

51 3.9206 3.6943 3.4780 -1.74 1.66

52 3.7878 3.5654 3.3531 -1.78 1.70

53 3.6601 3.4416 3.2332 -1.82 1.74

54 3.5374 3.3227 3.1183 -1.87 1.78

55 3.4195 3.2085 3.0079 -1.91 1.82

56 3.3060 3.0989 2.9021 -1.95 1.85

57 3.1969 2.9935 2.8005 -2.00 1.89

58 3.0919 2.8922 2.7029 -2.04 1.93

59 2.9909 2.7948 2.6092 -2.08 1.97

60 2.8936 2.7012 2.5193 -2.13 2.01

61 2.8000 2.6112 2.4328 -2.17 2.05

62 2.7099 2.5246 2.3498 -2.22 2.09

63 2.6232 2.4413 2.2700 -2.26 2.13

64 2.5396 2.3611 2.1932 -2.31 2.17

65 2.4591 2.2840 2.1195 -2.36 2.21

66 2.3815 2.2098 2.0486 -2.40 2.25

67 2.3068 2.1383 1.9803 -2.45 2.29

68 2.2347 2.0695 1.9147 -2.49 2.34

69 2.1652 2.0032 1.8516 -2.54 2.38

70 2.0983 1.9393 1.7908 -2.59 2.42

71 2.0337 1.8778 1.7324 -2.63 2.46

72 1.9714 1.8186 1.6761 -2.68 2.50

73 1.9113 1.7614 1.6219 -2.73 2.54

74 1.8533 1.7064 1.5697 -2.78 2.58

75 1.7974 1.6533 1.5194 -2.83 2.63

76 1.7434 1.6021 1.4710 -2.88 2.67

77 1.6913 1.5528 1.4243 -2.92 2.71

78 1.6409 1.5051 1.3794 -2.97 2.75

79 1.5923 1.4592 1.3360 -3.02 2.80

80 1.5454 1.4149 1.2942 -3.07 2.84

81 1.5000 1.3721 1.2540 -3.12 2.88

82 1.4562 1.3308 1.2151 -3.17 2.93

83 1.4139 1.2910 1.1776 -3.22 2.97

84 1.3730 1.2525 1.1415 -3.27 3.01

85 1.3335 1.2153 1.1066 -3.32 3.06

86 1.2953 1.1794 1.0730 -3.38 3.10

87 1.2583 1.1448 1.0405 -3.43 3.15

88 1.2226 1.1113 1.0092 -3.48 3.19

89 1.1880 1.0789 0.9789 -3.53 3.24

90 1.1546 1.0476 0.9497 -3.58 3.28

91 1.1223 1.0174 0.9215 -3.64 3.33

92 1.0910 0.9882 0.8942 -3.69 3.37

24 Domestic air conditioner


Functions and control

93 1.0607 0.9599 0.8679 -3.74 3.42

94 1.0314 0.9326 0.8424 -3.80 3.46

95 1.0030 0.9061 0.8179 -3.85 3.51

96 0.9756 0.8806 0.7941 -3.90 3.55

97 0.9490 0.8558 0.7711 -3.96 3.60

98 0.9232 0.8319 0.7489 -4.01 3.64

99 0.8983 0.8088 0.7275 -4.07 3.69

100 0.8741 0.7863 0.7067 -4.12 3.74

101 0.8507 0.7646 0.6867 -4.18 3.78

102 0.8281 0.7436 0.6672 -4.23 3.83

103 0.8061 0.7233 0.6484 -4.29 3.88

104 0.7848 0.7036 0.6303 -4.34 3.92

105 0.7641 0.6845 0.6127 -4.40 3.97

106 0.7441 0.6661 0.5957 -4.46 4.02

107 0.7247 0.6482 0.5792 -4.51 4.07

108 0.7059 0.6308 0.5632 -4.57 4.12

109 0.6877 0.6140 0.5478 -4.63 4.16

110 0.6700 0.5977 0.5328 -4.69 4.21

111 0.6528 0.5820 0.5183 -4.74 4.26

112 0.6361 0.5667 0.5043 -4.80 4.31

113 0.6200 0.5518 0.4907 -4.86 4.36

114 0.6043 0.5374 0.4775 -4.92 4.41

115 0.5891 0.5235 0.4648 -4.98 4.45

116 0.5743 0.5100 0.4524 -5.04 4.50

117 0.5600 0.4968 0.4404 -5.10 4.55

118 0.5460 0.4841 0.4288 -5.16 4.60

119 0.5325 0.4717 0.4175 -5.22 4.65

120 0.5194 0.4597 0.4066 -5.28 4.70

25 Domestic air conditioner


Seivice diagnosis

8.Dimensional drawings unit:mm

9.Center of gravity unit:mm

FA端盖 FB端盖 FC端盖


A(mm) 866 856 870

Domestic air conditioner


Service diagnosis

10. Service Diagnosis


10.1 Caution for Diagnosis
The operation lamp flashes when any of the following errors is detected.
1. When a protection device of the indoor or outdoor unit is activated or when the thermistor malfunctions,
disabling equipment operation.
2. When a signal transmission error occurs between the indoor and outdoor units. In either case, conduct the
diagnostic procedure described in the following pages.

Parameter of primary electronic appliance


NO N am e P a r a m e te r P ic t u r e

R ated voltage: 310V


R ated current: 0.2A
1 F an m otor
R ated frequen c y:

10.2 Problem Symptoms and Measures


Symptom Check Item Details of Measure

Check the power supply. Check to make sure that the rated voltage is supplied.
None of the units
operates
Check the indoor PCB Check to make sure that the indoor PCB is broken

Operation A power failure of 2 to 10 cycles can stop air conditioner


Check the power supply.
sometimes stops. operation.

Set the units to cooling operation, and compare the


Check for faulty operation temperatures of the liquid side connection pipes of the
of the electronic connection section among rooms to check the opening and
Equipment expansion valve. closing operation of the electronic expansion valves of the
operates but does individual units.
not cool, or does
not heat (only for
heat pump)
Diagnosis by service port
pressure and operating Check for insufficient gas.
current.

Large operating Check the installation Check to make sure that the required spaces for
noise and condition. installation (specified in the Technical Guide, etc.) are
vibrations provided.

27 Domestic air conditioner


Connector Wiring Diagram

1 .3 Error Codes and Description indoor display


Code indication

Indoor displaying panel code indication Outdoor


(LED1 fault description
Only For 498 and 498A display flash
Other
(Red/Green Time Run On times)
display
Flash Off ,)
Indoor and Communication fault between
E7 15
Outdoor indoor and outdoor units
E1 -- Room temperature sensor failure
Indoor E2 -- Heat-exchange sensor failure
Malfunction E4 -- Indoor EEPROM error
E14 -- Indoor fan motor malfunction
F12 1 Outdoor EEPROM error
F1 2 The protection of IPM
Outdoor Overcurrent protection of AC
F22 3
Malfunction electricity for the outdoor model
Communication fault between the
F3 4
IPM and outdoor PCB

F20 / 5 Compressor overload

F19 6 Power voltage is too high or low


F27 / 7 Compressor blocked
Overheat protection for Discharge
F4 8
temperature
F8 / 9 Outdoor DC fan motor fault
F21 10 Defrost temperature sensor failure
F7 11 Suction temperature sensor failure
F6 12 Ambient temperature sensor failure
Discharge temperature sensor
F25 13
failure
F30 Suction temp of compressor is too
14
high
F13 16 Less gas charge

F14 17 4-way-valve fault


deviate from the normal for the
F11 18
compressor
F28 19 Loop of the station detect error

F2 24 Overcurrent of the compressor


Overcurrent protection for
F23 25
single-phase of the compressor

1 .3.1 Thermistor or Related Abnormality


 ● 


outdoor display LED1 flash 10 times Defrost temperature sensor failure



LED1 flash 11 times Suction temperature sensor failure
LED1 flash 12 times Ambient temperature sensor failure
LED1 flash 13 times Discharge temperature sensor failure

28 Domestic Air Conditioner


    






       


       


 




                                         29
     
    


            

30
     
    


  




                                         31
     
    


  


32
     
    


  


33
     
    


 

 

                                       34
     
    




 

35
     
    


     
     

                                         36
     
    

                                       37
     
    

                                      38
     
    

                                     39
     
    

 

        

 

       

40
     
Circuit diagrams

11 Circuit Diagrams

+5V
+5V JP4
4 4-1971798-1-原色-立式
+5V R 94 +5V CN6

PIPE R O O M
R 30 3 J1 1 2
R 29 R 53 100ΩR ST 1K +5V 4 +5V
+5V 2 R OO M R 24 1K
10 K LED 1 R 93 100ΩMOD E 3 D S1 R 86 1K R 42 10 K
C 11 100n F 10 K 1 PIPE R 25 1K
C 46 R 85 2
IC 1 10 K
φ3-红色-散光-低亮 TJC 8-04(立式) C 29 C3 R 28 1 R 49
1 8 10n F R 83 R 27 D S2 R 109 10 K
A0 VC C R 40
2 7 C N1 5 10n F 10n F C 30 4.7u F-1206 1K
A1 W P

4.7K 1%
3-59-C O M M _R X
3-60-C O M M _T X

10 K

4.7K 1%
3 6 1 10 K J2 1 2
A2 SC L 5267 -04A -原色-立式 +5V
4 5 +5V 2 R 74 C 31 4.7u F-1206
GN D SD A 1K N etRG 2
JP3 4 3
M24 C04 N etRG 1

N etL abel243
3-62-N

3 4
N etL abel238

N etL abel239

+5V E E PRO M R 118 560ΩSC L 1K C 404 C 405 +5V


2 R 75
人感
B M (ad)

R 33 560ΩSD A 0.1u F 20
0.%1u-50
F V20 % -50 SW
V 2 机型选择
1
25/35

N etLab el241
ROOM

R 37 10K
10K
10K
FJ-fb

R3 N etRG 2 4 5
zj

A /B

2K TJC 8-04 (立式)


N etRG 1 3 6 C 28 C 20
C2
64

60
59
63
62
61

58
57
56
55
54
53
52
51
50
49
2SA1037A K 2 7 R 103 100n F

100nF
100nF
IC 2

R 96
20 K

R8
在线烧写 1 8
P1 R 5F100LEA F A R 104 2K
10 K B M (ad )
P130(out)
beep0/IN T 6/P140

T O 00/P01
T X D 1/A N 17/P02
beep1/IN T 7/P141
T I00/P00

sda10/R X D 1/A N 16/P03


SC L 10/SC K 10/P04

A V R E FP/A N 0/P20
A V R E FM /A N 1/P21
A N 2/P22
A N 3/P23
A N 4/P24
A N 5/P25
A N 6/P26
A N 7/P27

R 11 R ST ND I-04 H R 102 R 69 2K 25/35


48 PIPE
2K AN18 /P147 R7 2K A/B
R 10 R 23 47 R EMOTE_ R X
C1 P146
10 K 10 K 46 R EMOTE_T X
100n F scl00/TI07/TO07/P10 +5V
1 45
3-1-SW P120/AN19 sda00/TI06/TO06/ RXD0 /P11 3-45 -LINE -R X
2 44 CN8
复位电路 3
3-2-TD
3-3-FLZ
P43
P42/TI04/TO04
TI05/TO05/INT5/TXD0/ P12
sdaa0/TI04/TO 04/TXD2/ P13
43 N ettx
3-44 -LINE -TX D IG L
D IG H
R6
R 16
100Ω
100Ω
1 C OM3
B UZZ 1 FJ-pwm 4 42 N etrx 2 C OM2
PKM13 EP Y -4002 P41/TI07/TO07 scla0/sda20/TI03/TO03/ RXD2 /P14 E1
+12 V MOD E 5 41 3 +5V
R 82 220Ω-0805 P40/TOOL 0 scl20/TI02/TO02/P15
R ST 6 40 4 GN D
R ES R T (R XD0 )/INT5/TO01/T I01 /P16 SER R 18 100Ω 100u F-16 V
P31/IN T 4/T I03/T O 03/beep0

R 50 D S1 7 39 5 SER
蜂鸣器 P124/XT2 (TXD 0)/TO02/TI02 /P17 RCK R 17 100Ω
3

2K +12 V XT 1 D S2 8 38 6 RCK
P123/XT1 PC LB U Z1/P55 SR C K R 21 100Ω
2 9
N etLab el245 37 7 SR C K
P137/INT 0 P54 IR R 31 1K
10 36 SW ITC H 8 IR
B 10 B-PH -K -S-原色-立式 IC 8 C 15 100n F P122/X2 (INT11 )/P53 R 62 10 K
P76/IN T 10/R X D 2
P77/IN T 11/T X D 2

11 35 C 19 +5V B 8B -PH -K -S-原色-立式


P74/IN T 8/sda01

+12 V 9 8 P121/X1 (INT10 )/P52


P75/IN T 9/scl01

P30/IN T 3/scl11
P70/K R 0/scl21
1

CN5 COM E C 38 1u F 12 34 IR 1n F 注3 :R 53 ,R 6,R 16 ,R 18 ,R 17 ,R 21


UZ Z8M00G53 (三脚)8M - 0.5%
7 C BSTLS
B 5B -PH -K -S-红色 -立式

12V 10 R EGC IN T2/P51


P61/SD A A 0
P60/SC L A 0

C N5 ' 10 7C 7B C 37 13 33 LS TEP _D 阻值需根据选择的显示板


P62(开漏)

11 6 D STEP _A VS S IN T1/P50/sda11
P71/sda21

A
P06/T I06
P05/T I05
P73/K R 3
P72/K R 2

1 9 6C 6B E2 14 做相应调整
2 8 B 12
5C 5B
5 D STEP _B TV S 1 C 43 C6 1n F15
EV S S0
C 13 4 D STEP _C 5V/400 W VD D 1K R 73
P63

3 7 4C 4B 100n F 16 R EMOTE_ R X R 34
4 6 D 14
3C 3B
3 D STEP _D 100n F EVDD 0 +5V
15 2 U STEP _A +5V 10 K
5 5 12V 2C 2B 100u F-16 V C 21 +12 V
N etL abel244
N etL abel242

A 16 1 PTV S 5V0 S1UR 10 K


17
18
19
20
21
D ST E P_A 22
D ST E P_B 23
D ST E P_C 24
D ST E P_D 25
U ST E P_A 26
U ST E P_B 27
U ST E P_C 28
U ST E P_D 29
L ST E P_A 30
L ST E P_B 31
L ST E P_C 32

4 1C 1B R 38 10 K R 35
3 B 10n F
C U LN2003A -贴片 R2 10 K N1 D1 5
2 +5V
R 106
SD A
SC L

D JP1 C N3 6
B U ZZ

1 R5 1K zj 2SD1781KT146R 10 K R 43
2 R LS 4148 3
上下摆步进电机 +12 V C 16 N2
1 27Ω-0805 2
C 10 100n F 100n F
TJC 8-02 (立式) KRC119S 1
IC 12
9 8 自检/缩时 R EMOTE_T X 4.7K B 3B -XH -A -蓝色-立式
COM E D1 6
10 7 U STEP _B +5V
左右摆步进电机 7C 7B R 92 R 95 10 K 远程通讯
+12 V 11 6 U STEP _C FK 2K R LS 4148
C N11 'C N1 1 6C 6B
12V 12 5 U STEP _D 10 K R 99 C N5 1
5 5 5C 5B 2K 1
13 4 LS TEP _A
4 4 A 4C 4B 2K 2
14 3 LS TEP _B
3 3 B 3C 3B R 100 B 2B -XH -A -蓝色-立式
2 2 C 15
2C 2B
2 LS TEP _C
C 27
1 1 D 16
1C 1B
1 LS TEP _D 100n F N3 C 12 备注: 1.没有特殊标示下电阻为
R 36 10 K R 101 100n F
B 5B -PH -K -S-原色-立式 IC 3 TLP 421 +5V 10 K 0603 封装,精度为 5 %。
U LN2003A -贴片 房卡
B 5B -PH -K -S-原色-立式 +15 V R 39 1K FJ-fb 2.没有特殊标示下无极性电容为贴片
R 58 2SD1781KT146R 0603 封装,耐压50V ,精度 20 % 。
C 14
C N 9 风机输出 2.7K +5V 3.没有特殊标示下电解电容为85℃。
7 4.7u F-50V -105 ℃ R 60 FJ-pwm
1n F
6 风机反馈
+15 V E14
10n F/630V IC 7 +5V 390Ω C 24 R 88
5 10 K +5V
C X3 6 R 59 10 K
4
R 68 10 K 10n F R 108 R 1 10 K
3 R 57 B 2B -XH -A -R -红色-立式
10 K C N3 4+5V SW ITC H R4 C N1 4
2 10 K
4 GN D
1 +310 V TLP 421 C5 1K 1
C 17 E15 3 R 97 100ΩN ettx SW 1
R 64 TX 100n F 2
10n F 2 RX TS V C -1(5.85*7*7)
B 5P7-XH -A -原色-立式 10 K N etrx
5267 -04A -原色-立式 1
R 98 100Ω 应急开关
47u F-50V -105 ℃-高频 网络通讯

41 Domestic air conditioner


Circuit diagrams

+5V

R 13 1N 4007 (1000 mA/1000V )


330 IC 4 D1 1 R 14
R 90 L
3-41-COMM_T X R 12 47K -3W
4.7K R 15
N5 C8 E4

10 0K -1 /4W
2SD1781KT146R TLP 851/P C851 47K -3W
R 91 100nF -50 V ZD 4
IC 6 1N4746A (18V -1W )
4.7K D1 7 1N 4007 (1000 mA/1000V ) +12 V RED
R 22 N1
R 20 220V_ N L1

3
3-40-COMM _R X 2K -1/4W 100uF -50V -105℃
C N23 ' D4 K2
C 9 1K TLP 421 C Y3
R 19 1 OJE-SS (H )-112 L(D )
1n F 2.2n F-250VAC
10 K D25 0 R LS 4148 ION
1

4
D1 2 R 26 C N2 3
2K -2W C OMM C ON 2
C ON 1
1N 4007 (1000 mA/1000V ) 1

220V_ N 1 ION
C ON 3

L1
+12 V

4
K3
D5 OJE-SS (H )-112 L(D )
R LS 4148

3
L
+ 12 V
+12 V
R 112 +5V IC11 U LN2003 A +12 V
CN2
+ 12 D2 5 2SD1781KT146R R 117 10 K R 44 1K 1 16
WIRE D

4 3-20-FLZ 1B 1C 220V_ N

4
GN D 10 K N4 2 15
3 R 113 2B 2C D1 0
SIG R LS 4148 R 46 1K 3 14
2 R 116 3-29 -TD 3B 3C
R 111 10 K 4 13 K1
1 1K 4B 4C
D2 6 27Ω-0805 R 47 1K 5 12 OJE-SS (H )-112 L(D )
3-5-SW 5B 5C

3
B 4B - C 34 6 11 R 55 0Ω R LS 4148 C OMM
C 25 6B 6C
R 63 1K 7 10
R LS4148

X H A C ONTR O LLER 1n F R 115 3-23 -LINE-R X 3-1-N 7B 7C


10 K 8 9
N6 10n F E COM + 12 V
C 33 N1
+12 V

4
KRC119 S
4.7K D1 8
3-25 -LINE-TX 100n F K5
10 K
OJE-SS (H )-112 L( D) N
220V_

3
R LS 4148

100 -1206 +15 V


D20 6 100 -1206 R 011
15V-100mA
FR 106 (1A -600V -500ns) ZD00 3 R 202 10Ω-2512
R 203
1N4742A (12V -1W )
1N 5399(1500 m A /1 000V )

1N 4 746A (18V -1W )

ZD00 1
C 013 C 014 R 206
47uF-50V-10 5℃

E9 270 -2W C7
1N 5399 (1500 mA/1000V ) 4.7n F/250V 4.7n F/250V R 004
2.2K N00 1 100n F
+310 V 4 T1 KT C 8050
NTC 1 + 310 V 3
220-L R 205
SC K084 R 72 D7 5 102/1000V 560
10 nF /630V

D6 C 23 6 C 009 R 019
E7 R 78 1
C 002
47K /2W 7
100uF /450V

R 77 47Ω-1/2W
104 -630VDC
1N 53 99(1500m A /1000V )

TR A -SR W 19ES -X 5 8V013/B CK -6-FE-1901H 12V-900mA


220-N D1 9 10 -1206 12V /1A -15 V
1A/1000V + 12 V
FR10 6(1A -600V -500 ns)

D00 8
D9 D2 0
D8
D2 1 3000 mA/200V R 209
1N 5399 (1500 mA/1000V ) 1A/1000V 100Ω-1206
C Y1 C Y6
8
7
6
5

4.7n F-250VAC
IC 9 4.7n F-250VAC
ZD20 2
D /ST
D /ST
NC
VCC

A6059 H E204 C 32
22uF-50V-10 5℃

E8 1N4742A (12V -1W ) 100n F


GN D

1000uF -25V -105℃


BR

FB

IC 10
S

R 80
1.5K
1
2
3
4

R 61 C 010
TLP 421
1.5Ω-1/2W
1n F

10 uH-2 .5A
+5V
M BR 1100(1A -10 0V )

C N5 2 L2
C 35
1
+12 V 100n F D1 3
LC 1 BLM 21 P G 600 SN 1D
C 40 E6 C 42 C 53
220p F R 65
C N1 7 IC 5 1%
1 E5 R 76 1u F 100n F
C 41
470uF -25V -105℃

1 8 22Ω
D25 0 B OO T PH
2 7
Vin GN D
L1 100n F 3 6 470uF -25V -105 ℃
L FU SE1 EN C OM P
L1

LB 2271 (32 m H -0.35A ) 4 5


SS V S ENS E
220V_ L 220-L R 51
TP S 5402 R 79
47 0nF /275V

T3.15A 250 V C 13
4

100 K
BALC K C X2 C 26 C3 9 1%
10n F 10p F
~ 22 0VA C 100n F/275V 220p F
2 RV1
CX 1

R 71 R 81
C N2 1 200 K 1%
1

220-N
TV R 14621*620V
2.2nF -250VAC
C Y4 C Y5 C N2 7
1
C N21 ' 1 220V_2.2n
N F-250VAC
D25 0

42 Domestic air conditioner


Sincere Forever

Haier Group
Haier Industrial Park, No.1, Haier Road Edited by : Zhen Lingyun
Liu Yunlin
266101, Qingdao, China_
Signed by : Zhang Xianqiang
Http //www.haier.com
Approved by: He Shiquan

Domestic air conditioner


SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL

AS09FBBHRA AS12FBBHRA

AS18FEBHRA AS24FEBHRA
AS26FBBHRA AS35FBBHRA

AS53FEBHRA AS71FEBHRA

Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
Nederlands
Parts and Functions
Indoor Unit Remote controller
Display board
Inlet
(inside) Outer side of the controller

5. ON / OFF button
Inlet grille
8
6. Display of each function
9
status
10 7. Operation mode display
Outlet ON/OFF 7 11
Button 8. WIFI and CLOCK display
Air Purifying Filter Vertical blade 12
(inside) (adjust left and 9. TEMP display
TIMER
right air fl ow) Horizontal flap 13 10. Humidity display
(adjust up and down air flow
6
Don't adjust it manually) 11. FAN SPEED display

5
12. SWING display
Swing up/down display
swing left/right display
14
4 13. TIMER ON display
15 TIMER OFF display
Actual inlet grille may vary from the one shown in the CLOCK display
manual according to the product purchased 3 16
14. FAN button
2 SELF 17
CLEAN
15. QUIET button
1
Display board ECO SENSOR

16. HEAT button


1 4
17. SELF CLEAN button
1 Signal receiver hole 2

2 1. ECO SENSOR button


Ambient temp.display 3
When receiving the remote
control signal, display the set 2. DRY button
temperature.
Used to set DRY operation.
3 Operation mode indicator
(lights up when the compressor is on.) 3. COOL button
WIFI display
Used to set COOL operation.
4
4. TEMP button
used to change setting
temperature

NOTE:
a. Humidity display is unavailable on some models
Outdoor Unit b. If the model you buy has a WIFI function, press the“ON/OFF”
button for 5s to emit the WIFI binding signal. Once in the
binding mode, the APP will show how to bind.

OUTLET CONNECTING PIPING


AND ELECTRICAL WIRING
INLET DRAIN HOSE

1
Operation
18. TIMER button Clock set
19. CLOCK button
20. 10 ºC button
1 Press CLOCK button,

special heating set


function: 10 degree

2
heating maintaining
(valuable for RS) Press “+” or “-” to set
correct time.
21. HEALTH button
22. SMART button
Used to set SMART
operation. (This function
is unavailable on some Each press will increase or
models.) decrease 1min. If the button is
23. SWING up/down button kept pressed, time will change
24. SWING left/right button quickly.

25. SLEEP button 3


26. HEALTH AIRFLOW button
23 24
27. LIGHT button
22 25 Control the lightening and TURBO press APPLY, “AM” and
extinguishing of the indoor
21 26
LED display board. starts working.
Note:
20 27
28. CODE button
19 28 A-b yard The distance between the signal transmission head and
18 29
29. APPLY button the receiver hole should be within 7m without any obstacle
TURBO 30
30. TURBO button change-over wireless telephone is installed in the type

in receiving the signals, so the distance to the indoor unit


should be shorter.
Note: Full display or unclear display during operation indicates the
batteries have been used up. Please change batteries.
1. SMART+SLEEP:When the light sensing function is enabled,
If the remote controller can’t run normally during operation,
the appliance will be in the mode. If the appliance
detects that indoor light is weak (lower than the setting please remove the batteries and reload several minutes later
value) for several minutes, the light sensing function
Hint:
works automatically. If theappliance detects no movements
Remove the batteries in case unit won’t be in usage for
of people for 20 minutes , during which the light is weaker
a long period.
than the setting value , it will enter the “SMART+SLEEP”
mode automatically. The appliance will operate as per the
sleep curve.(See the“SLEEP”function in Page 7).
Dred operation
(This function is unavailable on some models.)
Conditions to exit: Haier Peaksmart enabled air-conditioners have a Demand
1) The appliance detects that the indoor light is stronger Response Mode display on the indoor unit.
than the setting value for 20 minutes. The display could be labelled d1, d2, d3 (wording may
2) The appliance is in the 8h “SMART + SLEEP” mode. differ model to model).
3) The “LIGHT SENSING” function is disabled. These modes are described in more detail below:
When any of the above conditions is met, the appliance will Mode Display Description What to do
exit from the “SMART+SLEEP” mode. Once out of the Your air-conditioner will continue
“SMART+SLEEP” mode, the appliance will operate under to cool or heat during the peak
the operation status initially set on the remote controller. DRM3 d3 demand event. The energy No action is required.
Note:1) This function is not available in the “AIR SUPPLY” consumed by your air-conditioner
mode. is capped to 75%.
2) This function is not available in the “SLEEP”mode. Your air-conditioner will continue
3) When it is in the "REMOTE SLEEP” mode or the to cool or heat during the peak
“TIMER”is on, the appliance will exit from this function. DRM2 d2 demand event. The energy No action is required.
consumed by your air-conditioner
4) Light sources like indoor lamps and TV’s LED
is capped to 50%.
light,and frequent movement s of pets will affect this
DRM1 mode is only activated during
function. Your air-conditioner is still turned
emergency demand management
on and the fan will continue to
2. Press “HEALTH”+“HEALTH AIRFLOW” simultaneously can DRM1 d1 operate. Your compressor is
situations. This mode will automatically reset
set and cancel the “LOCK” function ( ) the device within 2 hours .If your air-con is in
turned off and cool/hot air will no
this mode for longer than 2 hours please
longer be generated
contact Energex on 13 12 53.
2
Operation
QUIET Operation COOL,HEAT and DRY Operation

1 Unit start.

2 Select operation mode.


TIMER TIMER

Press the COOL button on


the remote controller.

SELF SELF
CLEAN CLEAN

ECO SENSOR ECO SENSOR

QUIET

Press the HEAT button on the remote controller.

You can use this function when silence is needed for rest or
reading.
For each press, is displayed Air conditioner starts
QUIET function operation. In QUIET operation mode, fan
Press the DRY button on the remote controller.
speed automatically takes low speed of AUTO fan mode.
Press QUIET button again, disappears, the operation
stops.

1. In DRY mode, when room temperature becomes


lower than temp. setting +2 ºC, unit will run
intermittently in LOW speed regardless of FAN
setting.
2. Remote controller can memorize each operation
status. When starting it next time, just press ON/
OFF button and unit will run in previous status.

3
Operation
1 button.

pressed, temp. setting


increases 1 ºC.

pressed, temp. setting


TIMER decreases 1 ºC. TIMER

SELF
Unit will start running to reach the SELF
CLEAN
ECO SENSOR
CLEAN
temp. setting on LCD.
ECO SENSOR
ECO SENSOR

2 AN Operation 1 ECO SENSOR


Press ECO SENSOR button,For each press,changes
as follows:
cancel

NOTE :

A human sensor is used to detect changes in the infrared radiationemitted by


human bodies. In case of the following conditions, the detection may not be
changes as follows: accurate:

temperature

The speed of human movement exceeds the sensitivity of the sensor.

objects due to the wind.


Moving targets go beyond the detection range of the sensor.

Unit will run at selected fan speed.


sharply.
Besides, if a person is at the border of two or three air blowing areas, the

automatically.

4
Operation
ECO SENSOR Operation HEALTH AIRFLOW Operation
Human Sensing Function
1. “Follow” function: It can detect where a person is and The setting of
adjust the swing flap accordingly and send air to the
location of this person. If it detects people in two
locations, the swing flap will blow alternatively between function
these two locations and stay at each location for 15s. If
the appliance detects people in three or more locations,
the left and right swing flaps will swing automatically. appears on the display. Avoid
“Avoid” function: When the appliance detects a person in
the body.
TIMER
a location, it will adjust the swing flap to avoid such a
location. If it detects people in three or more locations,
the left and right swing flaps will swing automatically.
Note: again, appears on the display.
1) When there are people in several locations or a
person frequently moves between several locations,if this direct to the body.
person is in the in-between location or the crossing
location, whether the appliance is in a “Follow” mode or
an“Avoid” mode, theswing flap will swing automatically to
send air to these locations. The cancel of
2) Whether the setting is “Follow” or “Avoid”, it takes some
time to adjust theair direction after the appliance identifies function
the location of the people and the air direction will not
change immediately. TORBO

3) If the actual airflow cannot reach (or avoid) the location


where a person is due to such factors as fan speed setting,
temperature setting, ambient temperature difference and
layout of the room, pressing the left and right swing flaps and outlet grills of the air conditioner are opened, and
can adjustthe air direction and set the airflow direction by the unit goes on working under the condition before the
hand.
grille will close automatically.
4) Set the health airflow when the human sensing
(including follow/avoid) function is enabled and exit from Notice:
the human sensing (including follow/avoid) function. Cannot pull direct the outlet grille by hand. Otherwise, the
5) Press the upper and lower swing flaps when the human grille will run incorrectly. If the grille is not run correctly,
sensing (including follow/avoid) function is enabled, there stop for a minute and then start, adjusting by remote
is no upper and lower full swing status. controller.
Remote controller can memorize each operation status.
6) When the appliance is in the upper and lower full swing when starting it next time, just press ON/OFF button and
status, set the human sensing function (including unit will run in previous status.
follow/avoid), the upper and lower swing flaps are in their
standard positions of relevant mode.
2. When the human sensing function is enabled, if the
appliance cannot detects people for a long time (at least Note:
20 minutes), it will automatically enter the power saving
mode. In the power saving mode, the operating frequency
will lower down and the fan speed is low. Once a person is 2. In heating, it is better to select the mode.
detected, the appliance will exit from the power saving mode. 3. In cooling, it is better to select the mode.
3. When the human sensing function is enabled, the 4. In cooling and dry, using the air conditioner for a
appliance will have a real-time detection of human long time under the high air humidity, a phenomenon
movements and adjust the frequency and fan speed falling drips of water occurs at the outlet grille.
according to the movements. In the heating mode, if the 5. Select the appropriate fan direction according to the
movements are frequent, the frequency and fan speed will actual conditions.
lower down; when the movements become less, the
frequency and fan speed will rise but cannot exceed the
setting values set by the remote controller. The cooling
mode is contrary to the heating mode.
5
Operation
SWING Operation TIMER Operation
Set Clock correctly before starting Timer operation. You can
let unit start or stop automatically a following times: Before
1 you wake up in the morning, or get back from outside or
after you fall asleep at night.

1 Select
mode.
your desired operation

For each press of “ ” button, air Select your desired


TIMER ON.
displays as follows according to
different operation modes: Remote controller: “TIMER ON”
TIMER

COOL/DRY: Select your desired


TIMER OFF.

HEAT: Remote controller: “TIMER OFF”

SMART: 2 Time setting.


TORBO

Initial state
TORBO

2 Every time the button is pressed,


time setting increases or decreases
1 min, if kept depressed, it will increase rapidly. It can be
adjusted within 24 hours.

For each press of “ ” button, remote controller


3
displays as follows:
remote controller:
APPLY
“ON” or “OFF”

Initial state

When humidity is high, condensate water might occur


at air outlet if all vertical louvers are adjusted to left or
right.

position for a long time in COOL or DRY mode,


otherwise, condensate water might occur.
To cancel TIMER mode
Just press TIMER button several times until TIMER
dispiay disappear.

6
Operation
Comfortable SLEEP
3 hours then stops. Temp. is lower than temp. setting
so that room temperature won’t be too high for your
Before going to bed, you can simply press the SLEEP sleep.
button and unit will operate in SLEEP mode and bring you
a sound sleep.

Temp. setting Unit stop

Press SLEEP 1 hr Decreases 2 ºC


button.
1 hr
Decreases 2 ºC
Operation Mode 3 hrs
3 hrs Rises 1 ºC
1. In COOL, DRY mode
SLEEP SLEEP
1 hours after SLEEP mode operation starts operation stops
starts, temp. will become 1 ºC In HEAT mode
higher than temp. setting. After
another 1 hours, temp. rises by
1 ºC further. The unit will run for
3. In SMART mode
further 6 hours then stops Temp.
The unit operates in corresponding sleep mode, which
is higher than temp. setting so
adapted to the automatically selected operation mode.
that room temperature won’t be
4. When quiet sleeping function is set to 8 hours the
too low for your sleep.
TORBO quiet sleeping time can not be adjusted. When TIMER
function is set, the quiet sleeping function can’t be
set up. After the sleeping function is set up, if user
resets TIMER function, the sleeping function will be
cancelled; the machine will be in the state of timing-
on, if the two modes are set up at the same time, either
SLEEP SLEEP
operation starts operation stops
automatically, and the other mode will be cancelled.
Approx. 6hrs
Power Failure Resume Function
1 hr
Rises 1 ºC
not start running unless 3 minutes have elapsed. When
the power resumes after power failure, the unit will run
1 hr Rises 1 ºC automatically, and 3 minutes later the compressor starts
running.

Temp. setting Unit stop


Note to the power failure resume:
In COOL, DRY mode
enter function after hearing four sounds. And press the
2. In HEAT mode
this function after hearing two sounds.
1 hours after SLEEP mode starts, temp will become
2 ºC lower than temp. setting. After another 1 hours,
temp decrease by 2 ºC further. After more another
3 hours, temp. rises by 1 ºC further. The unit will run for
further

7
Operation
SMART Operation Self Clean Operation
(This function is unavailable on ◆Functional description: the purpose of this function is to
some models)
clean the evaporator.
Entry and exit Press self clean button to enter this
One key can give you a
function, then it will display "CL" on the panel of the indoor
comfortable room! unit and also on the remote controller. After running 20-30
The air conditioning unit can minutes, this function will exit automatically when the " Pi "
judge the indoor temperature and sound is heard twice, then the unit returns to original state.
Under operation process of self clean, pressing the button
humidity, and make the adjustment
repeatedly has no effect and the function will not exit, but
accordingly. pressing the power off button and other mode button can
make it exit.
Note:
1.It has no effect under the mode of timer/sleep.
2.After this mode starts, the air volume may reduce or it
SMART SMART start may even have no airflow.
3.It is normal if the unit makes some noise like expanding
with heat and contracting with coldness.
Press ON/OFF button, unit starts. 4. The “CL” display time may last differently on the remote
Press SMART button “ ” is controller and panel.
5.It is normal if the temperature is below 0℃ outside, the
displayed on the remote controller. unit may display "F25"under this mode running.
TORBO
Please turn off the unit for 10 seconds then restart.
6.The best condition to run this mode: the temperature is
15℃~27℃ and the humidity is 35%~60% in the door,
the temperature is 30℃~40℃(cooling season) and
below 10℃(heating season) out the door.
7.It is hard to frost if the air is too dry(humidity<20%). and
if the humidity is too high(humidity>70%),
the condensate water may increase, which may move away
SMART FRESH
some frost.
SMART Defrost
SMART FAN SPEED
SMART FAN HEALTH
SMART DRY
SMART SOFT
SMART Control temperature

or SMART stops

The power saving function only works under the


cooling, heating or dehumidifying mode, after the
power saving function is set, press the sharp,
mute, sleep, or smart key to exit the power saving
function.
Under the cooling, heating and dehumidifying mode,
press the smart key to enter the smart function. Under After the power saving is set, the host machine will
the smart running mode, when the air conditioning is automatically adjust the setting temperature, and
running, it will automatically select cooling, heating, automatically control the switch of the compressor,
dehumidifying or blowing mode as When the smart which may be inconsistent with the user’s setting.
function is running, press the “cooling” “heating” or The power saving function is more effective after
“dehumidifying” key to switch to the other mode, you the air conditioning has been running for a long
will exit from the smart function. time (more than 2 hours)

8
Operation
HEALTH Operation ON/OFF operation and test operation

.
The water-ion generator in the
ON/OFF Operation:
Use this operation only when the remote controller is
airconditioner can generate a lot defective or lost, and with function of emergency running,
of anion effectively balance the air conditioner can run automatically for a while.
When the emergency operation switch is pressed, the
quantity of position and anion in “Pi” sound is heard once, which means the start of this
the air and also to kill bacteria operation.
and speed up the dust sediment
emergency operation starts, the unit will run automatically in
the following modes: Pi
air in the room. Room Designated Timer Fan Operation
temperature temperature mode speed mode

Above 24 ºC 24 ºC No AUTO COOL

Below 24 ºC 24 ºC No AUTO HEAT

It is impossible to change the settings of temp. and fan


Press HEALTH
speed, It is also not possible to operate in timer or dry mode.
button

Test operation:
Test operation switch is the same as emergency switch.
For each press, is displayed Use this switch in the test operation
TORBO
when the room temperature is below Pi Pi
Air conditioner starts health anion
16 ºC, do not use it in the normal
function operation. operation.
Continue to press the test operation
switch for more than 5 seconds.
After you hear the “Pi” sound twice,

Loading of the battery


Press HEALTH button for twice press,

1
disappears, the operation stops.

Remove the battery cover;

2 Load the batteries as illustrated. 2 R-03 batteries,


resetting key (cylinder); Be sure that the loading is
in line with the “+”/“-”;
When indoor fan motor is running, it has healthy
process function. (It’s available under any mode)
When the fan in the indoor unit does not work, the 3
health lamp lights up, but the anion generator does Load the battery, then put on the cover again.
not release anion.

9
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room Do not block the air inlet Remote Controller Indoor Body
temperature or outlet

Proper wipe the air conditioner by using a


temperature
soft and dry cloth.For serious stains,
use a neutral detergent diluted with
Do not usewater,wipe the controller water.Wring the water out of the
with a dry cloth.Do not use glass cloth before wiping,then wipe off the
cleaner or chemical cloth. detergent completely.

Do not use the following for cleaning


Close doors and windows Use the timer effectively
during operation

Gasoline,benzine, thinner or cleanser Hot water over 40 O C(104O F) may


may damage the coating of the unit. cause discoloring or deformation.
During cooling operation Air Filter cleaning
prevent the penetration
of direct sunlight with Press the “SMART” button for 5s to partially raise the panel.
curtain or blind
Open the panel by hand and support the panel with a holder
Remove the filter
Clean the filter
If the unit is not to be used Use the louvers effectively
for a long time, turn off the 5 Fit the filter
power supply main switch. 6 Remove the holder and close the panel
7 Long press the “SMART” button and the
panel will automatically lower down and
Once every
become closed two weeks
OFF

Replacement of Air Purifying Filter

1.Open the lnlet Grille 4.Attach the standard air filter


Press the “SMART” button for (Necessary installation)
5s to partially raise the panel.
ATTENTION:
The white side of the photocatalyst air purifying filter
2.Detach the standard air filter face outside,and the black side face the unit The green
side of the bacteria-killing medium air purifying filter face
Slide the knob slightly upward to
outside,and the white side face the unit.
release the filter, then withdraw it.
5.Close the Inlet Grille
Long press the “SMART” button and the panel will
automatically lower down and become closed.
NOTE:
Detach old Air Purifying Filter The photocatalyst air purifying filter will be solarized in fixed
time. In normal family, it will be solarized every 6 months.

The bacteria-killing medium air purifying filter will be used


for a long time,no need for replacement. But in the period
of using them ,you should remove the dust frequently by
3.Attach Air Purifying Filter using vacuum cleaner or flaping them lightly,otherwise ,
its performance will be affected.
Put air purifying filter appliances into the
right and left filter frames. Please keep the bacteria-killing medium air purifying filter in
the cool and dry conditions avoid long time directly sunshine
when you stop using it,or its ability of sterilization will be
reduced.

10
Cautions
WARNING
Please call Sales/Service Shop for the Installation.
Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.

WARNING
When abnormality such as burnt-small found, Use an exclusive Check proper
immediately stop the operation button and power source installation of the
contact sales shop. with a circuit drainage securely
breaker

OFF STRICT STRICT


ENFORCEMENT ENFORCEMENT
Connect power supply cord Use the proper voltage 1.Do not use power supply cord extended
to the outlet completely or connected in halfway
2.Do not install in the place where there is any
possibility of inflammable gas leakage around the unit.
3.Do not get the unit exposed
STRICT STRICT to vapor or oil steam.
ENFORCEMENT ENFORCEMENT PROHIBITION
Do not use power supply Take care not to damage Do not insert objects into the air
cord in a bundle. the power supply cord. inlet or outlet.

PROHIBITION PROHIBITION PROHIBITION

Do not start or stop the Do not channel the air flow directly Do not try to repair or Connect the earth
operation by disconnecting at people, especially at infants or reconstruct by yourself.
the aged. cable.
the power supply cord
and so on.

earthing
PROHIBITION PROHIBITION

CAUTION
Do not use for the purpose of storage of Take fresh air occasionally especially Do not operate the switch with
food, art work, precise equipment, when gas appliance is running at the wet hand.
breeding, or cultivation. same time.

STRICT
PROHIBITION ENFORCEMENT PROHIBITION
Do not install the unit near a fireplace Check good condition of the Do not pour water onto the unit
or other heating apparatus. installation stand for cleaning

PROHIBITION PROHIBITION PROHIBITION


Do not place animals or plants in Do not place any objects on or Do not place flower vase or water
the direct path of the air flow climb on the unit. containers on the top of the unit.

PROHIBITION PROHIBITION PROHIBITION

11
Trouble shooting Cautions
Before asking for service, check the following
Do not obstruct or cover the ventilation grille of the air
first. conditoner.Do not put fingers or any other things into the
inlet/outlet and swing louver.
Phenomenon Cause or check points This appliance is not intended for use by persons (including children)
with reduced physiced, sensory or mental capabilities or lack of
The system When unit is stopped, it won't restart
immediately until 3 minutes have experience and knowledge, unless they have been given supervision
does not restart
immediately. elapsed to protect the system. or instruction concerning use of appliance by person responsible for
When the electric plug is pulled out their safety. Children should be supervised to ensure that they do not
and reinserted, the protection circuit play with the appliance.
will work for 3 minutes to protect the
air conditioner. Specifications
During unit operation or at stop,
The refrigerating circuit is leak-proo f.
a swishing or gurgling noise may
Noise is heard be heard.At first 2-3 minutes after
unit start, this noise is more noticeable.
The machine is adaptive in following situation
(This noise is generated by 1.Applicable ambient temperature range:
refrigerant flowing in the system.)
During unit operation, a cracking Maximum:D.B/W.B 32oC/23oC
noise may be heard.This noise is Indoor Minimum:D.B/W.B 21oC/15oC
generated by the casing expanding
Normal Cooling Maximum:D.B/W.B 46oC/26oC
or shrinking because of
Performance temperature changes. Outdoor Minimum: D.B -20oC
inspection Should there be a big noise from Maximum:D.B 27oC
air flow in unit operation, air Indoor
filter may be too dirty. Minimum: D.B 15oC
Heating
This is because the system Maximum:D.B/W.B 24oC/18oC
Outdoor
Smells are circulates smells from the interior Minimum:D.B/W.B - 7 oC/-8oC
generated. air such as the smell of furniture, o o
paint, cigarettes. Outdoor Maximum:D.B/W.B 24 C/18 C
(INVERTER) Minimum:D.B -15oC
Mist or steam are
blown out. During COOL or DRY operation,
indoor unit may blow out mist. 2. If the power supply cord is damaged, it must be replaced by the
This is due to the sudden cooling manufacturer or its service agent or a similar qualified person.
of indoor air.
3.If the fuse of indoor unit on PC board is broken,please change
it with the type of T. 3.15A/ 250V. If the fuse of outdoor unit is
In DRY mode, when room temperature
In dry mode, fan broken,change it with the type of T.25A/250V
becomes lower than temp.
speed can’t be setting+2 oC,unit will run 4. The wiring method should be in line with the local wiring standard.
changed. intermittently at LOW speed
regardless of FAN setting. 5. After installation, the power plug should be easily reached.
Is power plug inserted? 6. The waste battery should be disposed properly.
Is there a power failure?
Is fuse blownout? 7. The appliance is not intended for use by young children or infirm
persons without supervision.
Is the air filter dirty?
Normally it should be cleaned 8. Young children should be supervised to ensure that they do not play
Poor cooling every 15 days.
Multiple with the appliance.
check Are there any obstacles before
inlet and outlet? 9. Please employ the proper power plug, which fit into the power supply
Is temperature set correctly? cord.
Are there some doors or
windows left open? 10. The power plug and connecting cable must have acquired the local
Is there any direct sunlight attestation.
through the window during the
cooling operation?(Use curtain) 11.In order to protect the units,please turn off the A/C first, and at least
Are there too much heat sources 30 seconds later, cutting off the power.
or too many people in the room
during cooling operation?

Haier
Address:No.1 Haier Road,Hi-tech Zone,Qingdao 266101 P.R.China
Contacts: TEL +86-532-8893-6943;FAX +86-532-8893-1010
Website: www.haier.com

12