Surface/Dermal

Surface

Ghost Wipes
For Lead and Other Metals on Surfaces

Data  Tough for wiping even rough surfaces


Interpretation  Readily and completely digest in hot water or acid solution
Lead on Surfaces
Lead is considered a hazard at  Meet specifications for sampling lead and other surface metals
surface levels of: • All ASTM E1792 specifications as required by U.S. EPA
 ≥ 40 µg/sq. ft. on floors • AIHA policy on sampling materials for lead in surface dust
• OSHA ID-125G, Addendum B
 ≥ 250 µg/sq. ft. on interior • OSHA OSS1 Lead on Surfaces by XRF
window sills
Make lead and other surface metal sample preparation and analysis easy with Ghost Wipes. Sturdy
Source: TSCA Section 403 Residential
Lead Standards (January 5, 2001 Federal
Ghost Wipe material holds together even when used on the roughest surfaces. In the lab, Ghost Wipes
Register) readily and completely dissolve during digestion to provide a more complete dispersion of the analyte of
interest for maximum recovery. Ghost Wipes dissolve so completely, there is no messy fibrous material
to clog the sample uptake capillary or nebulizer.
Wipe for Hexavelent
Chromium in Chrome Ghost Wipes — Not Just for Lead!
Plating Operations Use Ghost Wipes to collect samples of the following surface metals as specified in OSHA Method
SKC offers a coated filter wipe that
ID-125G, Addendum B.
meets the specifications of OSHA
Method W4001 for hexavalent • Antimony • Cobalt • Lead • Nickel
chromium on surfaces in chrome • Beryllium • Copper • Manganese • Vanadium
plating operations. The SKC • Cadmium • Iron • Molybdenum • Zinc
Hexavalent Chromium Wipe is • Chromium
a 37-mm binderless quartz filter
coated with sodium hydroxide. Un- Description Cat. No. Qty.
like uncoated filter wipes, sampling Ghost Wipes, moistened with deionized water, individually sealed packets, 225-2414 200
with the coated wipe stabilizes the use requires 10 x 10-cm template listed below 225-2413 1000
sample against acid interference in Templates
chrome plating environments and Plastic, 10 x 10 cm 225-2403 ea
eliminates the need for extracting Disposable manila paper, 10 x 10 cm 225-2415 250
the sample in the field. Analysis is 225-2415A 10
by ion chromatography with UV
detector. Each aluminized package
of 10 wipes includes plastic forceps Wipe Sample Test Kit
for proper handling of the samples For Evaluating Surface Contamination
according to the method, pk/10.
The Wipe Sample Test Kit provides the necessary
Cat. No. . ........................... 225-9025 supplies to sample surfaces for toxic materials that
can gain entry into the body via ingestion or skin
absorption. Each kit includes paper and glass
fiber filters, sterile sample bags, latex gloves,
cotton swabs, pH paper, and cover slips, 25
Ghost Wipes for lead and other metals, 72 mi-
croslides, 20 sample containers, 3 dropper bottles,
 Contains materials to sample surface metals, 1 plastic template (10 x 10 cm), marking pen,
pesticides, amines, radionuclides, corrosives, roll masking tape, roll clear tape, stainless steel for-
Smear Tabs and dust
Low-ash, acid-hardened paper de- ceps, and carry case. Solvents are not included.
signed for collecting samples on Description Cat. No.
 Assists in evaluating hazard control
surfaces where dust and chemicals Wipe Sample Test Kit
have settled, pk/100. effectiveness and cleaning regimens
Solvents are not included. 225-2401A
Template for HUD Lead Guidelines,
Cat. No. . ............................... 225-24  Convenient kit with supplies for OSHA wipe plastic, 30.5 x 30.5 cm (1 x 1 ft),
sample methods alternative to template in kit 225-2406

118 www.skcltd.com SKC Ltd. Phone: 01258 480188


Surface/Dermal
Surface

Microvacuum Cassettes for Surface Sampling


Data
Efficient Collection of Asbestos or Fungal Spores Interpretation
Fungal Spores on Surfaces
 Microvacuum nozzle on cassette for easy Guidelines for Microvacuum
sampling on surfaces and in carpeting Samples from Carpet
• Normal: < 5,000/1000 cm2 or
 Economical < 50,000/g

• Borderline: 25,000/1000 cm2


SKC Microvacuum Cassettes are designed spe- or 200,000/g
cifically for the collection and analysis of fungal • Elevated: 75,000/1000 cm2
spores or asbestos from carpets and other dusty or 1,000,000/g
areas. Each cassette is preloaded with an MCE
or polycarbonate filter and features an attached
microvacuum nozzle for easy sampling on surfaces
and in carpeting. Samples are sent to a laboratory
for analysis.
Stick-to-it
Dia. (mm) Filter Specifications Cassette Description Cat. No. Qty. Lift Tape
Microvacuum Cassettes for Asbestos or Fungal Spores For Surface Sampling of
25 0.45 µm MCE, BestChek, Carbon-filled polypropylene, 225-322 ea
for TEM analysis with cowl and nozzle
Biological Contaminants
37 0.45 µm MCE for TEM Styrene (non-conductive) 225-9543 ea Slide mailer for
analysis with nozzle Adhesive sample integrity
37 0.4 µm polycarbonate Styrene (non-conductive) 225-9542* ea area
with nozzle
Templates reusable plastic, 10 x 10-cm 225-2403 ea
disposable manila paper, 10 x 10-cm 225-2415 250
225-2415A 10
Carpet Sampling Cassette Kit includes 10 microvacuum carpet cassettes
Cat. No. 225-9542, 10 x 10-cm disposable templates, Luer adapters, zip bags,
and labels 225-9540 ea
* Also available in a convenient Carpet Sampling Kit • Easy to use and inexpensive
• Ensures consistent sample area
for better data interpretation
• Slide made of flexible plastic for

Sterile Surface Swab Kit sampling irregular surfaces


• Individually serialized for sample
For Biological Sampling identification

The easy-to-use Surface Swab Kit is ideal for Stick-to-it consists of a flexible
plastic microscope slide with
determining the relative degree and type of
an adhesive area. Simply iden-
biological contamination in an area. This non-
tify the sample area on the slide
destructive method can be used safely on most label, press the adhesive area
surfaces and materials. Each kit includes 10 sterile to the surface, place the slide
swabs in transport tubes and 10 templates. in the provided slide mailer,
and send it to a laboratory for
analysis.

Stick-to-it, pk/10
Description Cat. No. Qty.
Cat. No. ..................... 225-9808
Surface Swab Kit 225-2402* ea
Surface Swabs Only 225-2400* 50 Stick-to-it, pk/50
* Limited shelf-life
Cat. No. ..................... 225-9809

SKC Inc. Phone: 724-941-9701 www.skcinc.com 119