Programming the DZB312B007.

52DK Fuling inverter for a three-spindle setup, with specific


focus on F1 00 to F1 25, involves configuring the parameters and settings for each spindle.
Here's a detailed explanation of the programming process:

Parameter Mode: a. Power on the inverter and enter the Parameter Mode. Press the "Menu"
button on the inverter keypad. b. Use the arrow keys to navigate through the parameter
menus.
Basic Parameters: a. Locate the Basic Parameters menu and select it. b. Set the necessary
basic parameters such as frequency range, acceleration, deceleration, and maximum
frequency according to your spindle motor's specifications. c. Save the changes and exit the
Basic Parameters menu.
Multi-Step Speed Control: a. Locate the Multi-Step Speed Control menu and select it. b. Set
the number of steps required for each spindle. c. Assign the desired frequency values to each
step. In this case, for F1 00 to F1 25, you will set 26 steps from F1 00 to F1 25 incrementally.
d. Save the changes and exit the Multi-Step Speed Control menu.
Function Menu: a. Locate the Function Menu and select it. b. Set the function code for each
step corresponding to the desired frequency values. For example, set the function code for F1
00 as 00, F1 01 as 01, and so on until F1 25 as 25. c. Save the changes and exit the Function
Menu.
Run Command: a. Locate the Run Command menu and select it. b. Set the Run Command for
each spindle. You can assign a specific function code to start or stop each spindle
individually. c. Save the changes and exit the Run Command menu.
Communication Settings: a. If you're planning to control the inverter through external
devices, such as a CNC controller, you'll need to configure the communication settings. b.
Locate the Communication Settings menu and select it. c. Choose the appropriate
communication protocol (such as RS485 or Modbus) and set the communication parameters
accordingly. d. Save the changes and exit the Communication Settings menu.
Additional Parameters: a. Depending on your specific requirements and spindle motor
characteristics, you may need to configure additional parameters such as torque limits,
voltage settings, and motor control modes. Refer to the inverter's manual for detailed
instructions on these parameters. b. Locate the Additional Parameters menu and select it. c.
Set the necessary parameters based on your requirements. d. Save the changes and exit the
Additional Parameters menu.
Finalize and Save: a. After configuring all the required parameters for each spindle, review
the settings to ensure they are accurate and aligned with your spindle motor specifications. b.
Save the parameter changes and exit the Parameter Mode.

Remember to consult the user manual provided by Fuling for the DZB312B007.52DK
inverter for specific parameter names and values. It's crucial to have a thorough
understanding of your spindle motor's specifications and requirements to accurately set up
and program the inverter.