You are on page 1of 5

01 02 03 04 05 06 07 08

03
12,100 01 02 03 04 05 06 07 08
03
1,770 1,200 2,300 1,400 2,300 1,070 2,070 12,100
200 11,700 200
1,770 1,200 2,300 1,400 2,300 1,070 2,070
200 1,450 200 3,300 200 3,500 200 2,850 200 200 1,450 200 3,300 200 3,500 200 2,850 200
pv
1,650 3,500 500 2,900 500 3,050 1,650 3,500 500 2,900 500 3,050
I I I I
200 600

600

800
pv

1,800 200

1,200 600
2,100 200 1,200 600
pv pv pv

1,600 200
2,000
Kitchen

2,100

2,100
2,100

2,100

1,850

1,850
200 1,200
yard Balcony pv

1,500 800 1,200


pv pv
2,350

1,050 2,500 200 400 2,800 300 200 2,050 1,000

4,350
600 850 2,050
2,150

4,350
H Verandah pv H H H
pv pv

200

200
200

930

930
930

930
600 750

1,900 400
2,050
pv pv pv

F
G G G G pv

2,300
200 Bedroom

2,600
pv
200

3,000
1,150

03 study

2,850
pv pv
450 1,900 700 room pv pv

1,900

1,900
1,900

1,900
pv

3,200

200
500
+300 Kitchen 350 1,200 350 pv
3,700 200 3,100 200

1,500 400 150 1,000


pv

600 600 500

200
2,100

Dining 2,700 1,000

200 400 150


F F
1,800

F F
3,400

pv

100

1,700
1,500
200
pv pv Bath pv

1,700
pv

1,670

1,670
1,670

1,670
1,500
SH/WC pv pv ELEVATION 02

200
1,200 Pantry Bath

900
1,200 200 pv

1,100
2,050 900 300
700

1,200 150 900 2,050


600

pv pv

150
E pv pv E E Lobby 800 2,050 E ELEVATION 01

1,980
800
13,800

13,800
150
150
14,200

14,200
200

fp pv

900
900
1,500

1,200 100 2,250 200 900 Bath


293

2,800
pv

3,150
3,300

1,900
2,100
2,100

200
70

150 1,500
250

600 900
pv pv

04
04
0

150

4,300
4,000

4,000
4,000

4,000
pv

4,300
+150

3,800
17 16 15 14 13 17 16 15 14 13
12 12

02
02

4,000
Bedroom

150

150
11

700
11
guest

2,750
10
10
02
2,550
5,000

sunken

1,650
9
bedroom 3,050 200 1,300
9

lounge Lobby 8 8
pv

1,500
2,200

1,000
1,350
7 7
pv Master

1,400 550 700 200


200

550

550
6
550

550

2,950
6
1 2 3 4 5

3,150
1 2 3 4 5
Bedroom
D pv D D w.i.c D
pv

200

1,400 550 700


1,450
1,500
C C C C

1,050
1,050
pv
1,350

pv
pv
700

pv

1,400 200 500


700

700
1,400 200 500
700

700
pv pv pv pv pv pv pv pv
470 300 1,200 B pv B

200
200
B pv 300 1,700 1,350
200 B
2,050 800 400 1,500 500 1,000 100 1,200 300 1,550 1,500
200

2,200 650 1,400 500 800 800

1,400

1,400
1,400

1,400
Entry
1,400

700 1,400
+300

1,900
2,400

2,400
Balcony
2,400

2,400
porch
2,300
2,300

pv pv pv
pv

700

700

700
700
700
900

900
900

900

pv pv pv pv
A A A A

200
500 2,900 500
2,850 500 2,900 500 2,300 3,050
200 2,650 200 3,500 200 2,100 200 2,850 200
200 2,650 200 3,500 200 2,100 200 2,850 200
200 11,700 200 pv pv
200 11,700 200 pv pv
1,770 1,200 2,300 1,400 2,300 1,070 2,070
1,770 1,200 2,300 1,400 2,300 1,070 2,070 ELEVATION 04
12,100
12,100
01 02 03 01 04 05 06 07 08 01 02 03 01 04 05 06 07 08

MAIN ROAD
GROUND FLOOR UPPER FLOOR
90959

90960

AREA=113M2 AREA=115M2 ELEVATION 03

ACCESS ROAD

14,300
ROOF DETAILS 01 02 03 04 05 06 07 08
03

4,000
approved roofing stone coated steel tiles on
50x50mm battens on mini corrugated iron sheets on 1,750 1,200 2,300 1,400 2,300 1,070 2,070

MAIN ROAD
ic ic ic PROPOSED SITE

150x50mm rafters at 600mm centres 150x50mm purlins


PLOT NO. 90963
90962 90961

50x50mm ceiling joist(brandering) at 600mm centres I I

flower box
100x50mm ties & truts 100x75mm wall plate Drying
yard

12mm raw bolts cast into beam at 1200mm centres 2,100

2,100
ic

walkway
ridge tiles in coloured mortar to match fascia and gutter
all to S.E.s details.All timber to be celcured LOCATION PLAN
ic
H H
930

930
ROOF PITCH 45degrees 600x450mm MH cover & frame
G G
Eveaves=500mm TYPE CAPACITY NO. OF DESLUDGING DIMENSIONS IN MM 150mm rc cover slab

14,200
GL GL
IN PERSONS INTERVAL

150
LITRES (YEARS) A B C D E F1 F2
1,900

1,900
140mm thick
PROPOSED DEVELOPMENT 3M masonry wall
A 3000 10 2 800 1000 1000 3000 800 1200 1400

600
inlet
B 6000 20 2 800 1400 1200 3600 1400 1500 1400 1:3:6 conc.
F F

100

150

VARIES (3-6M)
28,000
28,100
C 9000 30 2 800 1400 1200 3600 1800 1500 1400

walkway
450x200mm deep
1,670

1,670
ic D 12000 40 2 800 1600 1400 4000 2000 1500 1300

RC beam to S.E.s details


450

450

E 15000 50 2 800 1600 1400 4000 2400 1500 1200


200mm dia. stone blocks
E E F 22500 100 1.5 800 3600 1800 5600 3000 1850 1500 for loose ground or where
specified
G 45000 200 1.5 800 5600 2800 8600 3600 2040 1500

flower box
2,400

2,400

R.C STAIRCASE DETAILS

flower box
H 67500 300 1.5 800 7600 3800 11600 4000 2260 1500
Typical section
Treads=250mm

04
septic I 90000 400 1.5 800 8800 4400 13400 4600 2380 1500
4,000

4,000
tank

walkway
B
Risers=150mm NB. 1.Soak pits o be used
02

200 800 200 D 200 800 200 on soils with good absorption
eg sand,red soil etc

all to S.E.details
150

150

soak
2.Depth to be specified

200
pit
A 100 B 100 C

A A
R.C SLAB DETAILS

600
550

550

E
2,700

2,700

Approved floor finish on D D 12mm dia. ms bars

200
9,800
at 150mm

150mm thick r.c slab 1:2:4 mix on C C DRIVEWAY


SOAK PIT
c/c bothways
700

700
Floor plan B

A142 BRC mesh wire on, 500g polythene B B Floor plan

DPM 300mm overlap on, 125mm RC cover slab


to engineer's detail
600x450mm cover
and frame
600x450mm cover
and frame

on 50mm sand blinding on 300mm thick


2,400

2,400
Inlet Outlet
well compacted approved H/C fill manhole TWL manhole

200

300

500
Invert level of
on firm ground.

200
1,400 600 600 600 1,400 A A
200

200

200

200

200

incoming drain

500
Sub-soil drain

16,200

F2
FOUNDATION DETAILS 190mm thick masonry E

F1
SECTION 01-01 stone wall with 10mm
10mm water proofing
600mm x 200mm thick strip foundation 1,750 1,200 2,300 1,400 2,300 1,070 2,070 rendering to approval
rendering to approval

to s.e details depth not exceeding ACCESS ROAD


SITE PLAN
1,200mm deep 01 02 03 01 04 05 06 07 08 Section A-A
150mm thick base slab

Section B-B
ROOF PLAN
SEPTIC TANK DETAILS
NOTES FINISHES ARCHITECTS CLIENT PROJECT DRAWING TITLE
1. All dimensions in mm unless stated otherwise 7. All drainage to comply with P.P. and M.o.W.H. and local

Production Drawings
2. All dimensions to be used as indI.Cated. No scaling off authority requirements.
the drawing. 8. D.P.C. to be 3 ply bituminous felt and to be provided under
3. All R.C. works to comply with SE drawings. all walls.
4. All I.Cs to have heavy duty covers. 9. Architect to be informed of any discrepancies before works
5. Permanent vents(p.v.)to be provided above all begins. SCALE: 1:150-1:100 DRAWN: CHECKED:

doors and windows as indI.Cated. 10. All drainage pipes passing under slab or driveway to be JOB No.
6. Depth of foundation to be determined on site. encassed in 150mm concrete sorround. ARCHITECT'S SIGNATURE CLIENT'S SIGNATURE DRG. No.01 DATE:

You might also like