Professional Documents
Culture Documents
Architectural Working Drawing-1-1
Architectural Working Drawing-1-1
03
12,100 01 02 03 04 05 06 07 08
03
1,770 1,200 2,300 1,400 2,300 1,070 2,070 12,100
200 11,700 200
1,770 1,200 2,300 1,400 2,300 1,070 2,070
200 1,450 200 3,300 200 3,500 200 2,850 200 200 1,450 200 3,300 200 3,500 200 2,850 200
pv
1,650 3,500 500 2,900 500 3,050 1,650 3,500 500 2,900 500 3,050
I I I I
200 600
600
800
pv
1,800 200
1,200 600
2,100 200 1,200 600
pv pv pv
1,600 200
2,000
Kitchen
2,100
2,100
2,100
2,100
1,850
1,850
200 1,200
yard Balcony pv
4,350
600 850 2,050
2,150
4,350
H Verandah pv H H H
pv pv
200
200
200
930
930
930
930
600 750
1,900 400
2,050
pv pv pv
F
G G G G pv
2,300
200 Bedroom
2,600
pv
200
3,000
1,150
03 study
2,850
pv pv
450 1,900 700 room pv pv
1,900
1,900
1,900
1,900
pv
3,200
200
500
+300 Kitchen 350 1,200 350 pv
3,700 200 3,100 200
200
2,100
F F
3,400
pv
100
1,700
1,500
200
pv pv Bath pv
1,700
pv
1,670
1,670
1,670
1,670
1,500
SH/WC pv pv ELEVATION 02
200
1,200 Pantry Bath
900
1,200 200 pv
1,100
2,050 900 300
700
pv pv
150
E pv pv E E Lobby 800 2,050 E ELEVATION 01
1,980
800
13,800
13,800
150
150
14,200
14,200
200
fp pv
900
900
1,500
2,800
pv
3,150
3,300
1,900
2,100
2,100
200
70
150 1,500
250
600 900
pv pv
04
04
0
150
4,300
4,000
4,000
4,000
4,000
pv
4,300
+150
3,800
17 16 15 14 13 17 16 15 14 13
12 12
02
02
4,000
Bedroom
150
150
11
700
11
guest
2,750
10
10
02
2,550
5,000
sunken
1,650
9
bedroom 3,050 200 1,300
9
lounge Lobby 8 8
pv
1,500
2,200
1,000
1,350
7 7
pv Master
550
550
6
550
550
2,950
6
1 2 3 4 5
3,150
1 2 3 4 5
Bedroom
D pv D D w.i.c D
pv
200
1,050
1,050
pv
1,350
pv
pv
700
pv
700
1,400 200 500
700
700
pv pv pv pv pv pv pv pv
470 300 1,200 B pv B
200
200
B pv 300 1,700 1,350
200 B
2,050 800 400 1,500 500 1,000 100 1,200 300 1,550 1,500
200
1,400
1,400
1,400
1,400
Entry
1,400
700 1,400
+300
1,900
2,400
2,400
Balcony
2,400
2,400
porch
2,300
2,300
pv pv pv
pv
700
700
700
700
700
900
900
900
900
pv pv pv pv
A A A A
200
500 2,900 500
2,850 500 2,900 500 2,300 3,050
200 2,650 200 3,500 200 2,100 200 2,850 200
200 2,650 200 3,500 200 2,100 200 2,850 200
200 11,700 200 pv pv
200 11,700 200 pv pv
1,770 1,200 2,300 1,400 2,300 1,070 2,070
1,770 1,200 2,300 1,400 2,300 1,070 2,070 ELEVATION 04
12,100
12,100
01 02 03 01 04 05 06 07 08 01 02 03 01 04 05 06 07 08
MAIN ROAD
GROUND FLOOR UPPER FLOOR
90959
90960
ACCESS ROAD
14,300
ROOF DETAILS 01 02 03 04 05 06 07 08
03
4,000
approved roofing stone coated steel tiles on
50x50mm battens on mini corrugated iron sheets on 1,750 1,200 2,300 1,400 2,300 1,070 2,070
MAIN ROAD
ic ic ic PROPOSED SITE
flower box
100x50mm ties & truts 100x75mm wall plate Drying
yard
2,100
ic
walkway
ridge tiles in coloured mortar to match fascia and gutter
all to S.E.s details.All timber to be celcured LOCATION PLAN
ic
H H
930
930
ROOF PITCH 45degrees 600x450mm MH cover & frame
G G
Eveaves=500mm TYPE CAPACITY NO. OF DESLUDGING DIMENSIONS IN MM 150mm rc cover slab
14,200
GL GL
IN PERSONS INTERVAL
150
LITRES (YEARS) A B C D E F1 F2
1,900
1,900
140mm thick
PROPOSED DEVELOPMENT 3M masonry wall
A 3000 10 2 800 1000 1000 3000 800 1200 1400
600
inlet
B 6000 20 2 800 1400 1200 3600 1400 1500 1400 1:3:6 conc.
F F
100
150
VARIES (3-6M)
28,000
28,100
C 9000 30 2 800 1400 1200 3600 1800 1500 1400
walkway
450x200mm deep
1,670
1,670
ic D 12000 40 2 800 1600 1400 4000 2000 1500 1300
450
flower box
2,400
2,400
flower box
H 67500 300 1.5 800 7600 3800 11600 4000 2260 1500
Typical section
Treads=250mm
04
septic I 90000 400 1.5 800 8800 4400 13400 4600 2380 1500
4,000
4,000
tank
walkway
B
Risers=150mm NB. 1.Soak pits o be used
02
200 800 200 D 200 800 200 on soils with good absorption
eg sand,red soil etc
all to S.E.details
150
150
soak
2.Depth to be specified
200
pit
A 100 B 100 C
A A
R.C SLAB DETAILS
600
550
550
E
2,700
2,700
200
9,800
at 150mm
700
Floor plan B
2,400
Inlet Outlet
well compacted approved H/C fill manhole TWL manhole
200
300
500
Invert level of
on firm ground.
200
1,400 600 600 600 1,400 A A
200
200
200
200
200
incoming drain
500
Sub-soil drain
16,200
F2
FOUNDATION DETAILS 190mm thick masonry E
F1
SECTION 01-01 stone wall with 10mm
10mm water proofing
600mm x 200mm thick strip foundation 1,750 1,200 2,300 1,400 2,300 1,070 2,070 rendering to approval
rendering to approval
Section B-B
ROOF PLAN
SEPTIC TANK DETAILS
NOTES FINISHES ARCHITECTS CLIENT PROJECT DRAWING TITLE
1. All dimensions in mm unless stated otherwise 7. All drainage to comply with P.P. and M.o.W.H. and local
Production Drawings
2. All dimensions to be used as indI.Cated. No scaling off authority requirements.
the drawing. 8. D.P.C. to be 3 ply bituminous felt and to be provided under
3. All R.C. works to comply with SE drawings. all walls.
4. All I.Cs to have heavy duty covers. 9. Architect to be informed of any discrepancies before works
5. Permanent vents(p.v.)to be provided above all begins. SCALE: 1:150-1:100 DRAWN: CHECKED:
doors and windows as indI.Cated. 10. All drainage pipes passing under slab or driveway to be JOB No.
6. Depth of foundation to be determined on site. encassed in 150mm concrete sorround. ARCHITECT'S SIGNATURE CLIENT'S SIGNATURE DRG. No.01 DATE: