You are on page 1of 2

SUREFLOW TECHNOLOGIES

SERIES 2000 VACUUM OPERATED GAS FEED SYSTEMS

• ECONOMICAL CHLORINATION

• ALL VACUUM OPERATION

• CONSTRUCTED OF THE FINEST


MATERIALS

• CYLINDER OR MANIFOLD MOUNTING -


ONE SIMPLE CONNECTION

• WORLD-WIDE REPRESENTATIVES
AND FACTORY TRAINED SERVICE

Applications Features
• Economy - At last, a high quality but
Municipal Water and Wastewater economical chlorinator. Proof that
Treatment quality doesn't have to be expensive.
For disinfection of potable water in • Safety - All vacuum operation. Remote
municipal, industrial, or private systems, ejector and direct cylinder mounting
as well as in motels, resorts, housing insures the highest degree of operator
projects and farm irrigation systems. An safety.
excellent chlorinator for municipal or • Construction - Fine silver rate valve
private waste-water treatment systems or and inlet valve provide long life and
industrial plants. accurate control. All machined body
parts produce the most durable
Industrial Water and Waste-water chlorinator available.
Treatment • Automatic Switchover - The
For industrial water and waste-water availability of automatic switchover
treatment, including: provides uninterrupted treatment. This
Treatment of metal finishing wastes, feature permits changing used
Cooling water disinfection, cylinders at the operators convenience
Chlorination of boiler make-up water, and without stopping treatment.
treatment of process or discharge water
from paper, food canning, brewing,
bottling, poultry processing and chemical
process plants.

4212 BETHLEHEM PIKE, TELFORD, PA 18969


TELEPHONE (215) 799-2420 FAX (215) 799-2424
WWW.SUREFLOWTECH.NET
SERIES 2000 VACUUM OPERATED GAS FEED SYSTEMS
Technical Data

Model Information Code Vacuum Tubing


Connections
Model 2 _ _ _ _ Max. Capacity Vacuum Vent
250 ppd (5 kg/h) 1/2" 3/8"
Gas 500 ppd (10 kg/h) 5/8" 3/8"
B- Carbon Dioxide
C- Chlorine Size Requirements - Distance
S- Sulfur Dioxide
The gas feeder can be a few feet to several
hundred feet from the ejector, depending on the
Vacuum Regulator Mounting maximum feed rate and the diameter of the
connecting tubing.
1-Cylinder or manifold
mounted with rate valve
ppd (kg/h) 100'(31m) 200'(61m) 500' (153m)
3- Cylinder or manifold 250 (5) 1/2" 5/8" 3/4"
mounted with remote meters and 500 (10) 5/8" 3/4" 1"
rate valve std. For 250 and
500PPD systems Ejector Connections
250 ppd (5 kg/h) Inlet 11/4" NPT Optional 11/2" hose
5- Cylinder or manifold mounted 500 ppd (10 kg/h) Outlet 11/2" hose 11/4" NPT
with automatic switchover
Materials of Construction:
Available Gas Flowmeters PTFE, PVC, polyethylene, tantalum, silver, silver
8- 250 PPD (5.0 kg/h) plated silicon bronze, monel, viton, and teflon.
9- 500 PPD (10 kg/h)

Maximum Capacity Back Pressure


V- 250 ppd (5.0 kg/h) Maximum back pressure at point of application for
5- 500 ppd (10.0 kg/h) a standard ejector is 140 psig. For pressures
greater than 140 psig, consult factory.
Accuracy: Within 4% of maximum flowmeter Feed Rate Capacities
capacity All feed rate capacities shown in this bulletin are for
Operating Range: 20:1, manual, 10:1 automatic chlorine. To determine those for other gasses,
Operating Temperature: Ejector 35 °F to 120 °F multiply the chlorine value by:
Other components: -20 °F to 120 °F Sulfur Dioxide: 0.95
Carbon Dioxide: 0.78
The system operating temperature is largely Gas Warning
dependent on the withdrawl rate of gas from the All unattended gas containers and gas feed
cylinder and is a function of the ambient equipment should be monitored for leaks. Gas
temperature. sensitive detectors, which will respond quickly to
gas leaks into the atmosphere, should be installed
REPRESENTED BY: at each site.
Options and Accessories
Inlet Water Assembly Booster Pumps
Scales Manifolds
Gas Detectors Isolating Valves
Corporation Stops Automatic Controls
Residual Analyzers Floor and Wall Cabinets

4212 BETHLEHEM PIKE, TELFORD, PA 18969


TELEPHONE (215) 799-2420 FAX (215) 799-2424
WWW.SUREFLOWTECH.NET

You might also like