You are on page 1of 16
KP-700 Wireless Keypad * G@Ge@O Table of Contents Foreword 1 Package List Product Overview 34 Power on Connect Keypad to Control Pane! Connect RFID Tag to Keypad 67 Connect Electronic Boor Lock Installation Enter Setup State 9 exit Delay 10 Setting for $05 Key uw Keyboard Tone 2 RFID Reader Setting 13-14 Direct Disarm by RFID Tag 15-16 Change User Code 7 Change Admin Code 18 Reset 19 0 Disarm 21 Stay Mode 22 Emergency Call 23 Mate Mode 23 Reteenc heen Usage Notices 24 Maintenance 24 FAQ eaten m cee ee icures Instructions of Wired Cable Interface Specifications Foreword Package List ‘Thank you for purchasing this wireless keypad, tis recommended to install outside the entry door and users can achieve operations such as arm, disarm, stay mode after inputting passcode, Moreover, the keypad can connect with an electronic door lock to work as an access contrel system DODO®H and then press [Disarm (@)] key or put RFID tag purchased xg @Q ® © separately close to the RFID reader to disarm the system. By this way, the door willbe opened easily, which is very convenient, Keypad x1. AAA 1.SV Battery x3 Screws x4 C Manual x2 Wired Cable x1 Product Overview fc e RFID reader ' Battery compartment. O\NONGY aonb arm DAOQO--* 4b samser svi CG GY - isarm DOOO-> wr D RFID tag / card (125KHz) can be purchased separately. © The keypad beeps twice every two seconds and the LED Max. 50 pes are supported. RFID Tag Or, + se °) indicator flashes once in case of low battery. Preparation before Use Power on Remove the insulating strip forthe first time, 1, Keypad uses 3pcs of AAA batteries. {0 Loose the screw, open the case {® Put batteries in according to the positive and negative signs, « Close the rear cover and screw on ‘open the rear cover of keypad will tigger tamper suite, please clams the alarm by fllowing the disarm instruction in age 21 2. When connected with electronic door lack as an access contro, keypad is suggested to use the speciic power supply for access control iknow connection ss peace eter tothe strucon manua cone oor lock The eetanc door oe and specie power sup fer access contel Steuld be purchase respecivey Connect Keypad to Control Panel Make sure the control panels in connecting state, input user code or admin codeon keypad, and then press any key of {Arm [Disarm] [Stay Model, The connection succeeds ater fone beep ier an ete cont th panel athe esd ar comecion (For dete cosecon np peer ewer mani of ane) Note tf the control panel beeps twice when connecting i means the keypad ha already connectes withthe pan he dt wer codes 1234, The det admin code 123456 Connect Keypad with RFID Tag 4. Input fadmin code + #] to wake up keypad. Three beeps mean wrong input rng inp fr 6 irs continu, ‘the eypud wil be locked for 20 secon. 2, Press (9), one beep is heard and the LED indicator is on Keypad enters learning state 23, Put RFID tag close to the RFID reader, the connection succeeds after one beep and the LED indicator goes out "Yoo espe ae hears tne the RID tag hae been connects betore To dear the connection of RAD ag, pt admin code + #towake up the ‘eypad and than press down] for si saconds. RAD 995 are al ceared ar ona beep, Connect Electronic Door Lock To know connection steps, please refer to the instruction ‘manual of electronie door lock Installation Fix the keypad on the door frame or the wall before use. “1 Loose the screw, open the case “2 Fix the rear cover on the door frame or the wall by screws “© Fasten the front cover of keypad on the rear cover. Secure two covers into place and then screw on Note: Opening the ear cover of keypad wil tigger tamper swt please sam the alm by following the aiarm instruction i page 23 Settings Exit Delay The keypad should enter setup state before al settings. Enter Setup State code + #] to wake up keypad. Under sen sate there eno operton wth 10 secon, the joa ett ate aatealy ou can 230 press [#10 at. The exit delay allows time to leave after arming the system, After the delay time, ifyou are sil at home, you may trigger an alarm, Ths sting doesnot apply 0 Stay Made, Ite ely te of ots contra pana an keypa ae set ely te respec the aul dela ne she total of batts. Exit Delay Ever setup stat input!—_aaelay inet \When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful ‘Once he delay ia se whan you am the keypad it wl beep once cry te Seconds to amin you to leave. Tha ening tin wl seed upin heat 5 seconds. er edly tne, the cont! pane Note: User ean input digital 0-250 which ers to 0-250 seconds. Default sting: 0, no daly. 10 11 Setting for SOS Key Keyboard Tone You can choose to input cade before pressing (SOS) key or not This function i to prevent false operation or trick Not Input Code for SOS Eerstup sae not ho (JOO BOOB QO06 4646 When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful Enable Code SOS En q When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful Note: Default setting: 0, Code SOS is disabled. Keyboard tone can be turned on or off itis off the successful setup tone will be closed too. Turn off Keyboard Tone Enter setup state, input ‘When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful Turn on Keyboard Tone Encor setup state input: jadoktrks) ‘when one beep is heard and the LED indicator keeps on for 10 secands, the setup is successful Note: Daft setting: 1, turn on the keyboard tone 12 13 RFID Reader Setting Disable RFID Reader Enter setup state, input X When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful Enable RFID Reader Enter setup state, input || BQO When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful Press [*] on the keypad and then cisaram the system by RFID. tag after this function was enabled. Disarming Silently by RFID Tag The conteol panel and siren will hoot twice when disaeming bby RFID tag. If et disarming silently by RFID tag, the control panel and siren will keep silent to finish disarming without disturbing neighborhood. Encersetup state input: xBik2a ‘When one beep is heard and the LED indicator keeps on for 10 secands, the setup is successful Note: Bafa setting: turn on disarm by RFID tag and the sten wll hoot when asatming, 14 15 Direct Disarm by RFID Tag ‘When direct disarm by RFID tag is enabled, users can directly present RFID tags to disarm the system and unlock the electrical door locks. However, the function consumes power greatly. {tis recommended to disable the function, thatis, the keypad sin sleeping state. Users need to press the [*) key before presenting RFID tags. Disable Direct Disarm by RFID Tag Entersetup state input: pie When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful Enable Direct Disarm by RFID Tag If the keypad is powered by DC 12V power, enable this. function, User can disarm the system by RFID tag directly, whieh is more convenient Enter setup state, input QOOO LO@ \When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful Note: Deft setting: 0, disable the function of direct disarm by RFD tag, 16 17 Change User Code Change Admin Code Using user code can wake up keypad, open electronic door lock, or send Arm, Disarm, Stay Mode commands to the control panel Te void pa reveal ease change user cose wren fest tire us, Change User Code Ener setup state input: kmsemew user code) Od 88 When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful Note: User code is 4 gts; default code is 12347 Using admin code can wake up keypad, send Arm, Disarm, Stay Mode commands to the control panel, and also change any settings of the keypad, To avoid passcode reves), please change admin code for first time. Change Admin Code Ereersetup sae, input | x@xemewadmin coder ‘When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful Note: Admin code is 6 digits: default code is 123456" 18 Reset Usage ‘A After reset, the user code, admin code, and other settings will restore to default except that the connected RFID tags can still disarm and open electronic door lock Entersetup state input: ower When one beep is heard and the LED indicator keeps on for 10 seconds, the setup is successful 19 Working with an alarm control panel, the keypad is more secure than the remote control. User code or admin code should be input before the operation of Arm, Disarm, Stay Mode, and Mute Mode. Arm Input user code or admin code, and press [Arm] key, the LED indicator flashes once and the keypad beeps once and sends (Arm) command to the control panel ‘When the alarm panel receives the signal, the siren will beep fonce and the [Arm] indicator will light on. The alarm system centers armed state AQAG ) I there is an intrusion, the alarm system will be triggered, the siren will hoot and the control panel willsend SMS and auto dial to pre-stored phone numbers to notify users. (SMS notification is applicable only for GSM alarm systems) 20 21 Disarm Users can disarm alarm system by using keypad or by using RFID tags. Using Keypad to Disarm Input user code or admin code, and press [Disarm key, the LED indicator flashes once and the keypad beeps once and sends [Disarm] command to the contral panel ‘When the alarm panel receives the signal, the siren will beep twice and the Disarm indicator will light on, the alarm system centers disarmed state In this state, the sensors being ‘triggered will not cause an alarm, Using RFID Tag to Disarm If direct disarm by RFID tag is disabled, user needs to press [*] towake up the keypad and then put RFID tag close to the reader to disatm and unlock the door, If direct disarm by RFID tag is tenable, user can put RAID tag close tothe reader to disarm and unlock the door directly. Stay Mode Input user code or admin code, and press [Stay Mode! key, the LED indicator flashes once and the keypad beeps once and sends [Stay Mode] command to the control panel (When the alarm panel receives the signal, the siren will beep ‘once and the [Stay Mode) indicator will light on, the alarm system enters stay mode state Allthe sensors in ather zones ave armed to prevent the Intruder except that the motion detector in Home Mode Zone 's disarmed, so that people can move freely at home. 22 23 Emergency Call If not inputting code for SOSis set, user just holds the (SOS) key for 3 seconds, the LED indicator flashes once, the keypad beeps once, and the control panel alarms immediately, inputting code for SOS is set, user needs to input user code or admin code before holding the {SOS} key for 3 seconds to send an alarm, Mute Mode Mute mode means thatthe LED indicators of contro! panel flash, but the siren does not beep, to avoid disturbing the neighborhood Input user code or admin code, and hold any key of [Atm] [Disarm] [Stay Mode] for 2 seconds, the LED indicator flashes once, the keypad beeps once and sends corresponding command to the control panel When the alarm panel receives ‘the signal, the LED indicator lights on or off, but the siren does not beep, Notices and Maintenance In order to avoid any harm to the users or others during usage and prolong the usage life, please abide by the following notices. Usage Notices ‘General instruction Forbiddance Thea non ep roa ese gay Hon fe ae ose Forbiddance of decomposition Maintenance You can get most dust or fingerprint off with a dry soft cloth or tissue. If there is drt on the keypad, please wipe the surface by a soft cloth with a litle dilute alkaline detergent and then wipe again with a dry ciath, 24 25 FAQ Problem Solution No response from keypad keypad connect to control panel No response trom the control panel by operat onkeypad © Cannot sisarm by RFID Tags Keypad cannot be programmed Keypad cannot be Srmed, disarmed and in stay mode Instructions of Wired Cables Interface (from Left to Right) +12 (RED WARE) ve of powe {GND (BLACK wire} Negative of power PUSH (YELLOW WaREy nal output for electronic lock (GND (WHITE WIRE): (OPEN (GREEN WIRE} nal input for ext ste 26 27 Specifications Product Name: keypad Model No: K>-700 Power Supply. 3 pcs of AAA batteries or DC 12V Static Current << 20uA (powered by batteries) Transmitting Current: < Zama, RFID Tags Supported: Sopes sitting Distance: << 80m (in open area) Radio Frequency: SISMH2 0° 433.92MH2 Only 433.92 Miz is avaliable for Europe ERP (dBm) MAX: 1355 Housing Materiat 85 pa ‘Operating Condition: Temperature: O°C to SOC Relate Humiaty: < $035 (non-condensing) Dimensions: 135,.50.15mm Net Weight: 903 CE cededaraton of conformity ery Chuang ls Gl ees tathe no eeuipnen ye K-700 Wie Keone incenplance nth Urecte 214/53/ The fle cheEUeaaan scanty waite athe olowginteet ers hugsytmmechangscon/angit/zotinea 2-700, 2 nrorwarton For THe useRs Arne andthe ace ate eoaatermsh tar mae Consign ‘dee ali conpnonetogeter to acti ooe cron ang ete sesso rnjiog cane otatas by your ac sano x 204i anate amendrem 7013/8660 stn arecie:Thaatedct Trebaterylates wr theeymtalnhhnay nesceletarngroinacte rv oa en a orerery ig) Far poser ein, urn eBay 2 28

You might also like