Professional Documents
Culture Documents
30'-11"
30'-0"
AREA AFFECTED BY ROAD WIDENING
REFERENCE
114'-8" 159'-1"
P R O P O S E D 40'-0" W I D E R O A D
1 LAYOUT BOUNDARY :
33
56'-4"
54'-2"
53'-8"
56'
699 888
144'-11"
TOTAL NO. OF PLOTS : 100
117'-0"
WATER HARVESTING PIT : R.W.H
32 2
52'-0"
52'-0"
52'
52'
676 766 TOTAL SITE AREA : 07 Acres38 Guntas 89 Sq Yds.
132'-6" 38566.80 SQ.Yds
119'-3"
100' ROAD AFFECTED AREA : 0 Acres 8 Guntas 88 Sq.Yds.
31 3 1056.26 SQ.Yds
52'-0"
52'-0"
52'
52'
689 762
137'-2" LANDUSE ANALYSIS SQ.Yds Sq.Mtrs PERCENTAGE
121'-0"
8"
76'-
PARK 30 4 REGULAR PLOTTED AREA 22458.48 18778.15 59.87 %
52'-0"
52'-0"
72
52'
792
'-1
553.00 Sq.Yds.
699
0"
'-7" 155'-9"
48
Sump
80,000 Lts 121'-0" 162'-0"
63'-7" 45'-0" 45'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 50'-0" 56'-8"
P R O P O S E D 30'-0" W I D E R O A D
P R O P O S E D 40'-0" W I D E R O A D
53 19
40'-0"
40'-0"
40'-0"
40'-0"
40'-0"
40'-0"
40'-0"
40'-0"
40'-0"
76 45 44 34 29 20 5
40'
50'-3"
50'-3"
P R O P O S E D 30'-0" W I D E R O A D
77 200 200 222 222 222 222 222 222 252
311 80'-7" PARK AREA 2934.26 2453.41 07.82 %
36'-1"
75 54 46 43 35 28 21 18 6
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
78 150 150 167 167 167 167 167 167 148
8
30'
60'-0"
174
60'
241
74 55 47 36 27 22 17 7 SOCIAL
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
42
P R O P O S E D 30'-0" W I D E R O A D
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
80 150 150 167 167 167 167 167 167
PRO. 30' ROAD
30'
151
42'-7" 30'-0" 30'-0"
80'-0"
72 57 49 40 25 24 15 UTILITY AREA 353.01 295.16 00.94 %
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
44'-10"
150 150 167 167 38 249 174 167 11 10 9
46'-8"
49'-10"
81
30'
259
61'-10"
137 236 166 166
75'-7"
71 58 50 39 14 NET SITE AREA 37510.54 31363.59 100.00%
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
50'
50'
82 150 150 167 167 204
30'-0"
102'-7"
30'
137
50'-0" 61'-3"
17'-7"
30'-0"
30'-0"
30'-0"
20'-10" 632 Sq.Yds.
83 150 150 167 148
30'-0"
77'-6"
60'-0"
168 44'-4"
69 60 52
30'-0"
30'-0"
30'-0"
98
12 Septic
38'-2"
63'-7"
168 50'-0"
P R O P O S E D 30'-0" W I D E R O A D
68 61
30'-0"
30'-0"
30'-0"
97 85 563 Sq.Yds.
167 168
100mm Ø
PVC vent pipe 3.00 150mm Ø holes
Manhole cover (min.) 750mm c/c 150mm thk. (Using SRC)
85'-5"
30'-0"
150 150
0.30 99.920
100.00 0.15 0.30 Free board 0.10 1.20
30'-0"
30'-0"
96 86
TWL
0.525 max. To Soakpit (or) Drain
0.30min. 0.30
Inlet 12mm thk plastering in
2.48 m
1.20
66 0.20 CC 1:1½:3 mix with 20mm metal
63
30'-0"
30'-0"
0"
CI Rungs @ 300c/c
150 150
CC 1:1½:3 mix
Mortgage plots
13
87
30'-0"
30'-0"
95
146'-9"
167
PLAN OF PERCOLATION PIT
168 45'-0"
SECTION 'AA'
25'-2"
65
30'-0"
30'-0"
88 369 Sq.Yds.
0.20
60'-0"
2.0
A A
64
30'-0"
30'-0"
0.20
7"
0.15 40mm METAL
9'- 167 168 0.15 0.20 9.40 m 0.20 4.70 m 0.20 0.15
450mm
SEPTIC TANK PLAN C/S OF PERCOLATION PIT
39'-10"
100 MM THICK
C.C BED
P R O P O S E D 30'-0" W I D E R O A D CROSS SECTION OF
STORM WATER DRAIN
45'-0"
45'-0"
54
99 186 79
'-4
204'-7"
14
'-9
"