You are on page 1of 1

C D NOTES

PB-2

1. THESE DRAWINGS SHALL BE READ IN CONJUCTION WITH DRG


COLUMN SCHEDULE NO-CELZ/TD/ST-3000 SHEET NO-1/1 AND OTHER DRGS MENTIONED

PB-2

PB-2
ON IT.
A B E F
450 2. THE STRUCTURE IS DESIGNED AS PER RELEVANT I.S CODE AND
PB-3 PB-3 PB-2 PB-2 PB-2 FOR FOLLOWING ENVIRONMENT CONDITIONS:
4
(a) SEISMIC ZONE: IV

450
PB-2
PB-1

PB-4
(b) BASIC WIND SPEED (Vb): 55M/SEC

PB-5

PLINTH BEAM LEVEL TO


PB-1
PB-1
PB-2 PB-5
REINFORCEMENT (c) EXPOSURE CONDITION: SEVERE

ROOF SLAB LEVEL


4#20
ARRANGMENT

PB-2
PB-2
3. PROPER COVER SHALL BE MAINTAINED FOR ALL RCC MEMBERS BY
PB-5 PB-5 ATTACHING SUITABLE COVER BLOCKS TO REINFORCEMENT
3 PB-5 PB-7
BARS.THE CLEAR COVER FOR PROTECTION OF MAIN
REINFORCEMENT FOR DIFFERENT MEMBERS SHALL BE FOLLOWS:

COL. SIZE b x l 450 x 450

PB-5
PB-1

(a) RAFT/FOOTING: 50 MM

PB-2
LONGITUDINAL 4#20

PB-2
(b) COLUMN: 45 MM
REINFORCEMENT
4#16

PB-1
(NOS-mmØ) (c) LINTELS,STAIR ETC: 45 MM

PB-5 PB-5 TRANSVERSE REINFORCEMENT #10@ 95 c/c NEAR ENDS (d) BEAM: 45 MM
2 WITHIN CONFINING REIN (L0)
(e) SLAB: 45 MM
TRANSVERSE REINFORCEMENT #8 @200c/c BALANCE
PB-1 PB-1 BALANCE PORTION (L1)
PB-1

CONFINED ZONE (L0) 500

PB-4
PB-5

4. DESIGN DATA

PB-2
450 (a) GRADE OF RCC: M 30 (DESIGN MIX)

PB-6
(b) GRADE OF REINFORCEMENT: TMT BARS OF GRADE FE-500D
PB-5 PB-5 PB-5 IN ABSENCE OF SOIL INVESTIGATION

}
(c) TYPE OF SOIL:
1

450
REPORT STR DES HAS BEEN CARRIED
(d) SBC -

PB-2
OUT ASSUMING MEDIUM SOIL.
(e) DEPTH OF FOUNDATION HAS BEEN DESIGNED
PB-1 REINFORCEMENT FOUNDATION- FOR SBC OF 150 KN/M2 AT 1.50 M
4#20 BELOW MGL. GE TO VERIFY THE DATA
PLINTH BEAM LAYOUT PLAN ARRANGMENT
WITH SOIL INVESTIGATION REPORT

FOOTING TO PLINTH
BEFORE EXECUTION. (ALL FOOTINGS
HAVE BEEN ASSUMED TO REST ON ONE

BEAM LEVEL
LEVEL)

(f) MASONARY: SOLID PCC BLOCK MASONARY : 100/200 THICK

C D COL. SIZE b x l 450 x 450


5. SLOPE OF ROOF AS PER ARCH DRG.
C1 C1 LONGITUDINAL 4#20
REINFORCEMENT
(NOS-mmØ)
4#16
TRANSVERSE REINFORCEMENT
A B E F WITHIN CONFINING REIN (L0)
#10@ 95 c/c NEAR ENDS

C1 C1 C1 C1 C1 TRANSVERSE REINFORCEMENT #8 @200c/c BALANCE


4 C1
BALANCE PORTION (L1)
CONFINED ZONE (L0) 500
COLUMN MAERKED C1
C1

C1 C1 C1 C1 C1
3
SNO. DATE DESCRIPTION INITIAL
REVISIONS

PROVN OF FIRE STN TO INCL GARAGE FOR TFF AND LIVING ACCN FOR
FIRE CREW WITH ALLIED INFRA INSIDE AREA OF 41 FAD

C1 C1 C1 SUB FIRE STATION


2 STRUCTURAL DETAILS:- COLUMN AND PLINTH BEAM LAYOUT PLAN
C1 C1
DATE 21 JUL 2022
DRN HAV N TAMANG CHIEF ENGINEER SHEET NO.
DES BY LEH ZONE 1/3
C1 DF. NO.

C1 C1 C1 SCALE NTS DRG.NO : CELZ/WD/ST/44-02/2022

1
C1 C1

COLUMN LAYOUT PLAN


CHAO BHARTIYA, IDSE
DIR (DES)
FOR CHIEF ENGINEER