Model(s): GMV-160WL/C-T Outdoor side heat exchanger of air air conditioner Indoor side heat exchanger air of air conditioner Type compressor driven vapour compression If applicable: driver of electric motor compressor Item Symbol Value Unit Item Symbol Value Unit Seasonal space Rated cooling capacity Prated,c 16.0 kW cooling energy ηs,c 310.0 % efficiency Declared cooling capacity for part load at given outdoor Declared energy efficiency ratio for part load at given temperatures Tj and indoor 27°/19 °C (dry/wet bulb) outdoor temperatures Tj Tj = + 35 °C Pdc 16.00 kW Tj = + 35 °C EERd 3.35 - Tj = + 30 °C Pdc 11.84 kW Tj = + 30 °C EERd 5.90 -
Tj = + 25 °C Pdc 7.55 kW Tj = + 25 °C EERd -
12.60 Tj = + 20 °C Pdc 6.49 kW Tj = + 20 °C EERd 17.50 - Degradation co-efficient Cdc 0.25 - - for air conditioners(*) Power consumption in modes other than ‘active mode’ Crankcase heater Off mode POFF 0.044 kW PCK 0.044 kW mode Thermostat-off mode PTO 0.005 kW Standby mode PSB 0.044 kW Other items Capacity control variable Sound power level, For air-to-air air LWA -/69 dB indoor/outdoor conditioner: air If engine driven: Emissions mg/kWh fuel flow rate, - 6600 m3/h NOx(**) - of nitrogen oxides input GCV outdoor kg CO2 eq measured GWP of the refrigerant 2088 (100 years) Contact details: Name of manufacturer: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 GREE ELECTRIC APPLIANCES,INC. OF ZHUHAI (*) If Cdc is not determined by measurement then the default degradation coefficient air conditioners shall be 0,25. (**) From 26 September 2018. Where information relates to multi-split air conditioners, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer. Information requirements (heat pump) Model(s): GMV-160WL/C-T Outdoor side heat air exchanger of heat pump Indoor side heat air exchanger of heat pump Indication if the heater is equipped with a no supplementary heater If applicable: driver of electric motor compressor Parameters declared for Average climate condition Item symbol value unit Item symbol value unit Seasonal space heating Rated heating capacity Prated,h 18.0 kW ηs,h 175.0 % energy efficiency Declared heating capacity for part load at indoor temperature Declared coefficient of performance for part load at given 20 °C and outdoor temperature Tj outdoor temperatures Tj Tj = – 7 °C Pdh 10.30 kW Tj = – 7 °C COPd 2.90 - Tj = + 2 °C Pdh 6.32 kW Tj = + 2 °C COPd 4.25 - Tj = + 7 °C Pdh 4.28 kW Tj = + 7 °C COPd 6.00 - Tj = + 12 °C Pdh 4.09 kW Tj = + 12 °C COPd 8.70 - Tbiv = bivalent Pdh 10.30 kW Tbiv = bivalent temperature COPd 2.90 - temperature TOL = operation limit Pdh 10.84 kW TOL = operation limit COPd 2.80 - Tj = – 15 °C (if TOL < – Tj = – 15 °C (if TOL < – Pdh kW COPd - 20 °C) 20 °C) Operation limit Bivalent temperature Tbiv -7 °C Tol -10 °C temperature Degradation co-efficient Cdh 0.25 - heat pumps(**) Power consumption in modes other than ‘active mode’ Supplementary heater Back-up heating capacity Off mode POFF 0.044 kW elbu - kW (*) Thermostat-off mode PTO 0.049 kW Type of energy input - Crankcase heater mode PCK 0.044 kW Standby mode PSB 0.044 kW Other items Capacity control variable air flow rate, outdoor Sound power level, - 6600 m3/h LWA -/72 dB measured indoor/outdoor measured Emissions of nitrogen mg/kWh NOx(***) - Rated brine or water flow oxides (if applicable) input GCV rate, outdoor side heat - - m3/h kg CO2 eq GWP of the refrigerant 2088 exchanger (100 years) Contact details: Name of manufacturer: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 GREE ELECTRIC APPLIANCES,INC. OF ZHUHAI (*) (**) If Cdh is not determined by measurement then the default degradation coefficient of heat pumps shall be 0,25. (***) From 26 September 2018. Where information relates to multi-split heat pumps, the test result and performance data may be obtained on the basis of the performance of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.