Postgraduate Student, Department of Orthodontics, Univer- INTRODUCTION
sity of Illinois at Chicago, Chicago, Ill, USA.
b
Statistician, Department of Orthodontics, University of Illinois Following the completion of orthodontic treatment,
at Chicago, Chicago, Ill, USA.
one of the most important goals is maintaining the
c
Clinical Professor, Department of Orthodontics and Dento-
facial Orthopedics, Boston University, Boston, Mass, USA. finished result. It was reported that approximately 70%
d
Engineer Research Associate, Research and Standards of orthodontic cases result in some degree of relapse.1
Department of the Sciences Institute of the American Dental The causes of relapse are due to a number of different
Association, Chicago, Ill, USA.
e
Director, Research and Standards Department of the factors, including the periodontium, occlusion, soft
Sciences Institute of the American Dental Association, Chicago, tissue, and growth.2,3 Various removable and fixed
Ill, USA. retainer appliances are implemented to maintain the
f
Associate Professor, Department of Orthodontics, University
finished orthodontic result. Some examples of retention
of Illinois at Chicago, Chicago, Ill, USA.
Corresponding author: Dr Phimon Atsawasuwan, Associate appliances include traditional Hawley retainers, spring
Professor, Department of Orthodontics, University of Illinois at aligners, and fixed lingual retainers.4 Clear thermoplas-
Chicago, Chicago, IL 60612, USA tic retainers have increased in popularity due to their
(e-mail: patsawas@uic.edu)
desired esthetics and ease of fabrication.5 When
Accepted: October 2018. Submitted: June 2018.
Published Online: January 2, 2019
compared to the traditional Hawley retainers, clear
Ó 2019 by The EH Angle Education and Research Foundation, thermoplastic retainers have been found to be equally
Inc. effective in retention following orthodontic treatment.6
The two most common materials used for vacuum- Eighty specimens of the prepared material were
formed retainers (VFRs) are polyethylene polymers divided randomly into eight groups (with 10 specimens
and polypropylene/ethylene copolymers. Polyethylene in each of the cleaning solution and toothbrushing
polymers are considered more esthetic because the groups). The eight different cleaning methods evaluat-
material is virtually transparent; however, polypropyl- ed were: Invisalign Cleaning Crystals (Align Technol-
ene/ethylene copolymers are considered to be more ogy, Inc.; San Jose, Calif); Retainer Brite Cleaning
durable and flexible.7 A study showed that environ- Tablets (Dentsply International; York, Pa); Polident
mental conditions such as temperature, humidity, and Antibacterial Denture Cleaner (GlaxoSmithKline; Phil-
pressure influence the mechanical behaviors of various adelphia, Pa); Listerine Cool Mint (Johnson & Johnson
clear thermoplastic products.8 Several studies have Consumer, Inc.; New Brunswick, NJ); 2.5% vinegar;
focused on work of fracture,9 wear resistance,10 and 0.5% sodium hypochlorite; 3% hydrogen peroxide; and
Figure 2. Standardized toothbrushing machine. The arrow repre- Figure 4. (A) Photo showing profilometer stylus and specimen
sents the direction of brushing stroke. holder. (B) Diagram showing specimen measurement locations.
Table 1. Descriptive Statistics (%) and Pair-wise (P Values) Mean Differences of Surface Roughness From Baseline to 6 Months Among the
Cleaning Methods
Invisalign 0.6% 3%
Cleaning Retainer 2.5% Sodium Hydrogen
Cleaning Methods Mean 6 SE Crystals Brite Polident Listerine Vinegar Hypochlorite Peroxide Toothbrushing
Invisalign Cleaning 0.01 6 0.03 - 1.000 1.000 1.000 1.000 0.561 1.000 1.000
Crystals
Retainer Brite 0.04 6 0.02 1.000 - 1.000 0.561 0.191 0.013* 1.000 0.330
Polident 0.01 6 0.01 1.000 1.000 1.000 1.000 1.000 0.930 1.000 1.000
Listerine 0.01 6 0.03 1.000 0.561 1.000 - 1.000 1.000 1.000 1.000
2.5% Vinegar 0.02 6 0.01 1.000 0.191 1.000 1.000 - 1.000 1.000 1.000
0.6% Sodium 0.04 6 0.03 0.561 0.013* 0.930 1.000 1.000 - 0.252 1.000
tests. SEM images at baseline and the end of the 6- Multiple comparisons indicated that the specimens
month period were compared. The specimens were cleaned with Retainer Brite exhibited the largest
gold plated and images were collected at 10 kV, and surface roughness change, which was significantly
500X magnification. different compared to the specimens cleaned with the
0.6% sodium hypochlorite (P , .01) (Table 1).
Statistical Analysis However, qualitative analysis of the SEM images of
the specimens cleaned with Retainer Brite (Figure 5B)
Analysis of variance (ANOVA) and Bonferroni test
compared to the images of the specimens cleaned with
for multiple comparisons were performed for the mean
the 0.6% sodium hypochlorite solution (Figure 5C) at
differences among cleaning methods. Student’s t-test
5003 magnification exhibited no appreciable differenc-
was used for comparison of variables between
es in the surface features at 6-months and baseline
baseline and 6 months. Data analyses (SPSS statistics
(Figure 5A). The multiple comparisons showed that
V.22.0, IBM Corp, Armonk, NY) were performed and
specimens cleaned with 3% hydrogen peroxide exhib-
statistical significance was set at 0.05.
ited the greatest change in flexural modulus, which
was significantly different compared to the specimens
RESULTS
cleaned with Listerine (P , .05) (Table 2). There were
At baseline, there was no mean significant difference no statistically significant mean differences among the
of the tested variables among the specimens (P . .05). cleaning methods for light transmittance, F(7, 32) ¼
Comparison of mean differences from baseline to 6 0.601, P value ¼ .750.
months of each variable for all the different cleaning The Student’s t-test indicated a consistent decrease
methods showed statistically significant mean differ- in light transmittance through the polypropylene/ethyl-
ences in both surface roughness: F(7, 32) ¼ 2.926, P ene copolymer specimens for all cleaning methods at 6
value , .05; and flexural modulus: F(7, 32) ¼ 2.829, P months compared to baseline (Figure 6). All cleaning
value , .05, values among the cleaning methods. methods produced similar surface roughness and
Figure 5. SEM images of copolymer specimens from (A) baseline, (B) 6 months after Retainer Brite and (C) 6 months after 0.6% sodium
hypochlorite.
Table 2. Descriptive Statistics (MPa) and Pair-wise (P values) Mean Differences of Flexural Modulus From Baseline to 6 Months Among the
Cleaning Methods
Invisalign 0.6% 3%
Cleaning Retainer 2.5% Sodium Hydrogen
Cleaning Methods Mean 6 SE Crystals Brite Polident Listerine Vinegar Hypochlorite Peroxide Toothbrushing
Invisalign Cleaning 18.37 6 30.64 - 1.000 1.000 0.618 1.000 1.000 1.000 1.000
Crystals
Retainer Brite 35.09 6 24.41 1.000 - 1.000 0.101 1.000 1.000 1.000 1.000
Polident 22.60 6 60.07 1.000 1.000 - 0.397 1.000 1.000 0.089 0.939
Listerine 34.82 6 27.24 0.618 0.101 0.397 - 1.000 0.580 0.007* 1.000
2.5% Vinegar 8.99 6 30.95 1.000 1.000 1.000 1.000 - 1.000 1.000 1.000
0.6% Sodium 19.03 6 26.57 1.000 1.000 1.000 0.580 1.000 - 1.000 1.000
flexural modulus values at 6 months compared to surface roughness values were well below 0.5 lm as
baseline. measured by the surface profilometer. The implication
is that the significant roughness change might not be
DISCUSSION clinically significant. For instance, a report about the
scale of perception of roughness by human tongues
Essix Cþ, made from a polypropylene/ethylene
demonstrated that human tongues could not detect
copolymer, is a desirable material for thermoplastic
roughness at a scale smaller than 0.5 lm.18 Given that
retainers due to its translucent and durable nature.7
the magnitude of surface roughness values measured
Despite its esthetic advantage, research has been
in the present study were less than 0.5 lm, it could be
limited on evaluating the effect of cleaning methods on
reasoned that this statistical difference in surface
the function of the material. In addition, it seems that
roughness is not clinically relevant.
different thermoplastic materials behaved differently
The mean differences between specimens values at
once exposed to different cleaning solutions.12,13 The
6 months and baseline indicated that the 3% hydrogen
present study evaluated the long-term effects of
peroxide resulted in the greatest difference in flexural
various cleaning methods, which have been suggested
modulus. As listed on the MSDS sheet for Essix Cþ,
to patients by orthodontists for use with Essix Cþ
the material is not compatible with oxidizing agents.19
without good information on the long-term effects on
Therefore, this finding was not surprising given the
the behavior of the material.
powerful oxidizing abilities of hydrogen peroxide.20
In this study, mean differences between 6 months
Polymer oxidation is known to result in an increase in
and baseline indicated that Retainer Brite showed the
stiffness (increase in flexural modulus).21,22 Given Essix
most change in surface roughness. However, the
Cþ incompatibility with oxidizing agents, the diluted 3%
hydrogen peroxide is speculated to have acted as an
oxidizing agent that led to the statistically significant
change in flexural modulus value over the six month
time period.
In this study of cleaning methods, polypropylene/
ethylene copolymer specimens in all groups, stored in
artificial saliva at 378C between cleaning interventions,
demonstrated aging appearance as a decrease in
translucency over time. The degree of decrease in
translucency of the specimens varied among the
cleaning methods.
A limitation of this study was that the flat specimens
did not mimic the clinical shape of thermoplastic
retainers, which follow the contour of teeth. However,
flat specimens were deemed necessary in this study to
Figure 6. A bar graph of copolymer light transmittance between provide a uniform cross-sectional area to make
baseline and 6 months (*P , .05). standard flexural modulus and light transmittance
measurements, which provided standard results that in a simulated intraoral environment. Orthod Waves. 2006;
can be used in future studies. Although the specimens 65:64–72.
were flat, they were processed (heat-vacuum formed) 9. Pascual AL, Beeman CS, Hicks EP, Bush HM, Mitchell RJ.
The essential work of fracture of thermoplastic orthodontic
in the same manner used to fabricate thermoplastic
retainer material. Angle Orthod. 2010;80:554–560.
retainers, minimizing the effect of this limitation on the 10. Raja TA, Littlewood SJ, Munyombwe T, Bubb NL. Wear
study. resistance of four types of vacuum-formed retainer materi-
als: a laboratory study. Angle Orthod. 2014;84:656–664.
CONCLUSIONS 11. Zafeiriadis AA, Karamouzos A, Athanasiou AE, Eliades T,
Palaghias G. In vitro spectrophotometric evaluation of
The results indicate that specific cleaning methods Viverat clear thermoplastic retainer discolouration, Aust
affect the long-term light transmittance of polypropyl- Orthod J. 2014;30:192–200.