You are on page 1of 2

VAIBHAV RESPIRABLE DUST SAMPLER

VRDS 500NL
SPECIAL FEATURES
 Modular design for easy operation
 Drain plug for manometer fluid leveling
 Sturdy aluminum construction with SS hardware
 Low Noise during operations
 Less variation in flow even chocking of filter
 Maintenance free Suction assembly
 Totally eliminated of EMI
 Compact, Portable, Easy to Operate-Transport & Handle
 Arrangement for Parallel Gaseous sampling
 Light provision for working in night & dark area
 Design to runs continuously 24 hours or more
 Castor provide easy internal movement
 Common Body (Housing) structure for all the model
which will easy converted to any of the below model
 Suitable for Outdoor Use, Corrosion free lockable housing
Vaibhav Respirable Dust Sampler VRDS 500NL is designed to
measure respirable suspended particulate matter in ambient air. It is
used for collection of PM10 suspended particulate matter up to
small as 0.1 micron in size. It also has provision to collect samples
of gaseous pollutants such as SO2, NOx, H2S, F2, CL2, etc. in
impinger tubes for further analysis to determine their individual
concentrations. This advanced unit is meets the requirement
recommended by the Central Board for Prevention & Control of
Water Pollution, New Delhi. Emission regulations (December
1985) Part III.
TECHNICAL WORKING : Ambient air laden with suspended particulate enters the system through the corrosion free
aluminum modular inlet pipe. As the air passes through the cyclone, which divides the particulate matter in to two
fractions one is Respirable dust and another coarse cum non Respirable dust from the air stream by centrifugal forces
acting on the solid particles. These separated particulates fall through the cyclone’s conical hopper and collect in the
sampling bottle place at its bottom. The fine dust forming the Respirable fraction of the Total Suspended particulate
(TSP) pass through the cyclone and is carried by the air stream to the Filter Paper, clamped between the top cover and
filter adaptor assembly. The respirable dust is retained by the filter and the carrier air exhausted from the system
through the blower.
STANDARD ACCESSORIES : The Standard instrument is supplied with set of sample inlet assembly, Main instrument (Main
Instrument consist of blower, filter holder assembly, voltage controller, time totalizer, digital timer, manometer assembly etc..),
User convenience kit with tools, operational manual and accessories are supplied with instrument. All Vaibhav products are
lockable and can be opened by single master key provided with each instrument.
OTHER PRODUCTS
Stack Monitoring Kit Fine Dust Sampler (PM 2.5 Sampler) Attachment for PM 2.5 Sampling
Handy Velocity Monitor Combo Sampler (FOR PM 10 & PM 2.5) Weather Station
Gaseous Sampler Respirable Dust Sampler (PM 10) Accessories & Consumables
High Volume Handy Stack Sampler Handy Sampler Calibration Kit for SMK/RDS/FPS/HS
NOx Apparatus Personal Sampler Chemical Kit
Local Air Quality Sampler Attachment for Gaseous Sampler Flue Gas Analyzer
FOR PRICING, INFORMATION AND QUERIES CONTACT:

VAIBHAV EQUIPMENT SERVICE


5, Chintamani Society, Ramnagar, Sabarmati, Ahmedabad-380005. Gujarat.
Phone : 079- 2751 7010 Mobile : 09427380743, Email : vaibhavequipment@gmail.com
specification and design are subject to change without prior notice
VAIBHAV RESPIRABLE DUST SAMPLER
VRDS 500NL
TECHNICAL SPECIFICATION

SPECIFICATION VRDS 500NL


Basic features :
Brushless & belt less almost maintenance free & zero
consumable noise less turbine blower,
10 micron down to 0.1 micron (depending upon type of filter used). A cyclone is used for
fractionating the dust into two fractions, D-50 for the cyclone is at 10 microns. RSPM is
Particulate Sampling :
accumulated on the filter paper (8”X10” size) while coarse dust is collected in a cup placed under
the cyclone
To accommodate any standard filter paper of 25 x 20 cm, particulate bigger than 10 micron
Filter Holder :
collected in separate dust cap under the cyclone
8” X 10” (203mm X 254mm / 20.3cm X 25.4 cm) Glass microfiber filter for common use and EPM
Filter Media :
2000 or equivalent for special monitoring / research work
Flow Rate : Free flow 0.9 – 1.4 m3/min free flow with filter and more than 2.0 m3/min without filter
IS Reference : Match the basic requirement prescribed in BIS 5182(Part-23) 2006 for sampling
Timer Recorder : 0 to 99999.99 hrs. time totalizer records the running time in hours
Programmable Real Time control system with control of automatic start & stop, number of required
Clock / Timer : intervals can be programmed, Timer is used to start and shut off the sampler at preset time
Sampling Time : 30 hours (maximum)
Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage. For
Power Requirement :
proper operation and safety a good earth connection is mandatory
Dimension : Approximately 410mm X 300mm X 700mm
Separate provision for collection of Respirable and non Respirable (less than and greater than 10
Particle Size :
micron) size particles
The body of RDS is robust enough to withstand impacts and vibration in transportation, it is made
Construction :
of heavy aluminum sheet.
Provision has been made for light in the sampler for taking reading during dark area and in night
Night View :
hours and
Hardware : Only SS corrosion free hardware used in sampler
Weight : 41 Kg
ALL THE ABOVE INSTRUMENT IS HAVING THE DIFFERENCE OF BASIC FEATURES WHILE DIMENSION, FUNCTIONS
AND ITS STRACTURES REAMINS ALMOST SAME IN ALL MODEL
Warranty : ALL VAIBHAV PRODUCTS CARRY 14 MONTH WARRANTY

FOR PRICING, INFORMATION AND QUERIES CONTACT:


VAIBHAV EQUIPMENT SERVICE
5, Chintamani Society, Ramnagar, Sabarmati, Ahmedabad-380005. Gujarat.
Phone : 079- 2751 7010 Mobile : 09427380743, Email : vaibhavequipment@gmail.com
specification and design are subject to change without prior notice