You are on page 1of 5

Equipment Name Reinjection Compressor 2nd Stage Discharge Cooler

Tag 23-HA-103

Shell CASE
Side Fluid Base Case
Cooling Water Case-1
Cooling Water Case-2
Cooling Water
Heat Exchanged (KW) 3945.9 4704 4741
Natural Gas Molar flow(MMSCFD) 59.72 69.62 67.74
Mass flow rate(Kg/hr.) 60602.61 70459.00 68745.71
Molecular Weight 20.37 20.37 20.37
Natural Gas Inlet Temp.(C) 137.90 140.08 137.89
Natural Gas Outlet Temp.(C) 50 50 45
Cooling Water flow rate(Kg/hr.) 227880 285840 272160
Cooling Water Supply Temp.(C) 35 35 35
Cooling Water Return Temp.(C) xx xx xx
Cooling Water Supply Pressure(Kpag) 350 350 350
Cooling Water Return Pressure(Kpag) xx xx xx
Natural Gas Supply Pressure(Kpag) 10211 10248.3 10016.04
Natural Gas outlet Pressure(Kpag) xx xx xx
Exchanger Geometry
Type H-BFU
I.D(mm) 765
Tube Length(mm) 3050
No. of Tubes 750
Tube O.D(mm) 19.05
Tube Thk.(mm) 1.65
Tube MOC SS316
Baffle type Double Segmental
% cut 25
Spacing C/C(mm) 240

H2O 0.00351 0.00355 0.00356


CO2 0.05521 0.05521 0.05521
Nitrogen 0.00472 0.00472 0.00472
Methane 0.82755 0.82751 0.82751
Ethane 0.06023 0.06023 0.06023
Propane 0.02761 0.02760 0.02760
i-Butane 0.00432 0.00432 0.00432
n-Butane 0.00843 0.00843 0.00843
i-Pentane 0.00241 0.00241 0.00241
n-Pentane 0.00221 0.00221 0.00221
n-Hexane 0.00181 0.00181 0.00181
n-Heptane 0.00120 0.00120 0.00120
n-Octane 0.00060 0.00060 0.00060
n-Nonane 0.00020 0.00020 0.00020
n-Decane 0.00000 0.00000 0.00000
n-C11 0.00000 0.00000 0.00000
@0.5 Bar Delta P(Tube Side)

Required Temp. as per HMB. However its depands upon Heat Transfer area provided. We can say output from Exchanger Ratin
Cooling Water Supply flow rate should be fixed
Cooling Water Supply Temperature should be fixed
Output from Exchanger Rating.

Output from Exchanger Rating.

Output from Exchanger Rating.


y output from Exchanger Rating.
Notes:
1. Gas Composition as per HYSYS Model Received.