You are on page 1of 5

 

Telephone:
Fax:
VAT Registration No.:

Name: CONTROL SYSTEM Manufacturer: Opel/Vauxhall


Address: Model: CORSA
Year: 97
Registration: X16XE
Tel - Private: Mileage:
Tel - Business: Job number:
Tel - Mobile Date

Control system

Fuel pump relay

Checking operation - Fig. 25

Technical Data
Terminals Condition Resistance
87 & 30 Battery voltage disconnected
87 & 30 Battery voltage connected Zero
Battery + to terminal 86
Battery - to terminal 85

NOTE: Ensure battery voltage supply is connected correctly. Otherwise relay could be damaged.

Ensure ignition switched OFF.


Remove relay.
Check resistance between relay terminals.
Connect battery voltage supply to specified relay terminals.
Check resistance between relay terminals.

Checking supply voltage - Fig. 26

Manufacturer: Opel/Vauxhall Model: Corsa-B 1,6 (c) Autodata Limited 2013


Engine code: X16XE Output: 78 (106) 6000 . 5/27/2023
Tuned for: R-Cat Year: 1994-00 V9.200-
Technical Data
Terminals Condition Voltage
2 & earth Ignition ON Battery voltage
4 & earth Ignition OFF Battery voltage

Switch ignition ON.


Relay should be heard to operate.
If relay is not heard to operate: Check fuses.
Switch ignition OFF.
Remove relay.
Check voltage between relay base terminal and earth.
Switch ignition ON.
Check voltage between relay base terminal and earth.
If voltage not as specified: Check wiring.

Engine control module (ECM)

NOTE: Trouble codes must be erased after completion of ECM tests. Refer to Self-diagnosis section.
NOTE: Due to small size of ECM harness multi-plug pins it is advisable to access the pins at the rear of multi-plug.

Checking supply voltage - X14XE/X16XE/X16XEL - 
Fig. 27

Technical Data
Terminals Condition Voltage
A6 & earth Ignition OFF Battery voltage
C16 & earth Ignition ON Battery voltage
D3 & earth - Corsa-B/Tigra Ignition ON Battery voltage

Ensure ignition switched OFF.


Disconnect ECM multi-plugs.
Check voltage between harness multi-plug terminal and earth.
Switch ignition ON.
Check voltage between harness multi-plug terminals and earth.
If voltage not as specified: Check wiring and relays.

Checking earth connection - X14XE/X16XE/X16XEL - 
Fig. 27

Manufacturer: Opel/Vauxhall Model: Corsa-B 1,6 (c) Autodata Limited 2013


Engine code: X16XE Output: 78 (106) 6000 . 5/27/2023
Tuned for: R-Cat Year: 1994-00 V9.200-
Technical Data
Terminals Resistance
B1 & earth Zero
C7 & earth Zero
C9 & earth Zero
D7 & earth Zero
D16 & earth Zero

Ensure ignition switched OFF.


Disconnect ECM multi-plugs.
Check resistance between harness multi-plug terminals and earth.
If resistance not as specified: Check wiring.

Checking supply voltage - C16XE - Fig. 28

Technical Data
Terminals Condition Voltage
D10 & earth Ignition ON Battery voltage
D12 & earth Ignition OFF Battery voltage
D13 & earth Ignition OFF Battery voltage

Ensure ignition switched OFF.


Disconnect ECM multi-plugs.
Check voltage between harness multi-plug terminals and earth.
Switch ignition ON.
Check voltage between harness multi-plug terminal and earth.
If voltage not as specified: Check wiring and relays.

Checking earth connection - C16XE - Fig. 28

Technical Data
Terminals Resistance
A1 & earth Zero
A16 & earth Zero
C15 & earth Zero
C16 & earth Zero
D9 & earth Zero

Ensure ignition switched OFF.

Manufacturer: Opel/Vauxhall Model: Corsa-B 1,6 (c) Autodata Limited 2013


Engine code: X16XE Output: 78 (106) 6000 . 5/27/2023
Tuned for: R-Cat Year: 1994-00 V9.200-
Disconnect ECM multi-plugs.
Check resistance between harness multi-plug terminals and earth.
If resistance not as specified: Check wiring.

25 26

27

Manufacturer: Opel/Vauxhall Model: Corsa-B 1,6 (c) Autodata Limited 2013


Engine code: X16XE Output: 78 (106) 6000 . 5/27/2023
Tuned for: R-Cat Year: 1994-00 V9.200-
28

Manufacturer: Opel/Vauxhall Model: Corsa-B 1,6 (c) Autodata Limited 2013


Engine code: X16XE Output: 78 (106) 6000 . 5/27/2023
Tuned for: R-Cat Year: 1994-00 V9.200-