Professional Documents
Culture Documents
Revision of Chapter 14 - Pantry Car and Mini Pantry Equipment of LHB Manual (Electrical)
Revision of Chapter 14 - Pantry Car and Mini Pantry Equipment of LHB Manual (Electrical)
CHAPTER 14 ...................................................................................................................... 1
PANTRY CAR AND MINI PANTRY EQUIPMENT .............................................................. 1
INTRODUCTION ................................................................................................................. 1
14.1 CHAIR CAR COACHES (Mini Pantry) EQUIPMENT: ........................................... 2
Hot Case ............................................................................................................... 2
Refrigerating Unit .................................................................................................. 2
Cooling Compartment ........................................................................................... 3
Bottle Cooler Compartment ................................................................................... 3
Water Boiler Unit ................................................................................................... 3
Soup Warmer ........................................................................................................ 4
14.2 COMPOSITE PANTRY EQUIPMENT FOR LHB TYPE & GARIB RATH EOG
COACHES ............................................................................................................ 4
Hot Case ............................................................................................................... 4
Refrigerating Unit .................................................................................................. 5
14.3 MODULAR INTEGRATED PANTRY EQUIPMENT FOR HOT BUFFET EOG
COACHES ............................................................................................................ 5
Integrated Modular pantry equipment ................................................................... 5
Cooking and Service Table Assembly................................................................... 8
Catering and Service Counter ............................................................................... 9
Storage Compartment with Sinks .......................................................................... 9
14.4 JOINT PROCEDURE ORDER FOR PROPER UPKEEP OF PANTRY CARS ... 10
Revised LHB Maintenance Manual (Electrical) Chapter 09
CHAPTER 14
PANTRY CAR AND MINI PANTRY EQUIPMENT
INTRODUCTION
Pantry equipment are provided either in the separate pantry cars attached with the
rake or in the coaches itself function as mini pantry according to the type of train and
requirement of the passenger. The layout of these pantry cars and mini pantries has
been approved by railway Board. EOG coaches are governed mainly by RDSO’s
specification nos. ELPS/Spec/EOG/01, March 1994 and ELPS/Spec/EOG/02,
November 1994. Pantry car equipment are governed by RCF’s Spec. EDTS-118E or
its latest versions.
The basic pantry equipments provided in the LHB rake are as under:-
COMPOSITE PANTRY EQUIPMENT FOR LHB TYPE & GARIB RATH EOG
COACHES (Ref: RCF specification No.EDTS-139,Rev-E,Corr-5)
MODULAR INTEGRATED PANTRY UNIT FOR LHB TYPE HOT BUFFET EOG
COACHES (Ref: RCF specification No.EDTS-118,Rev-e,AM-2,Corr-3)
a) Hot case
b) Bottle cooler
c) Deep freezer
d) Fridge 300 litres capacity
e) Horizontal water boiler 3 nos
f) Water purifier
g) Hot plate 4 x 2000 W
h) Hot plate 1 x 5300 W
i) Electric chimney
j) Oven toaster griller
k) Insect killer
IRCAMTECH/GWL/ELECT/2022-23//LHB/Manual/1.1 Page 1 of 11
Revised LHB Maintenance Manual (Electrical) Chapter 09
Hot Case
Hot case is meant to keep warm and warm up pre-cooked dishes in casseroles.
Vegetarian and non-vegetarian dishes can be kept warm separately. In order to
fulfill this requirement, hot case is divided into 3 separate parts.
Salient Features
Dimensions :910 x 1092 x 640 (600+40)mm
Power Supply :230 Volt (+/-10%), 50 Hz (+/-3%)
Heating element :3 x 500 Watt
Hot air blower :240 Volt (+/-5%), 50 Hz
Operating temperature :110°C
Thermostat Range :30 – 110°C
Trays :21 nos., 250 x 495mm stainless steel
fabricated food
Refrigerating Unit
Salient Feature
Dimension : 1157 x 595 x 1195 mm
Max. Power : 800 Watt (2x400 Watt)
Power Supply : 230 Volt (+/-10%), 50 Hz (+/-3%)
Thermostat range : Deep freezer -18 to -25°C
Bottle cooler 0 to + 10°C
Cooling compartment 0 to +10°C
IRCAMTECH/GWL/ELECT/2022-23//LHB/Manual/1.1 Page 2 of 11
Revised LHB Maintenance Manual (Electrical) Chapter 09
Cooling Compartment
The Bottle cooler is to simultaneously cool 1.0 liter bottles to a temperature level
of 3 to 5°C. Suitable arrangement has been made to prevent falling over/ rolling
around of bottles inside the bottle cooler when bottle cooler is not completely
filled up.
Water boiler of 30 liters capacity confirming to IS: 3412 is provided along with a
control box and necessary plumbing and tap arrangement on a common base
plate. There are three nos. of such boilers provided on side wall of coach. Inlet
to one of the boilers can be used for preparing tea/ coffee. Base plate and
plumbing are suitably modified to suit provision of water filter. Other two water
boilers are connected directly to over head tank of coach with the help of flexible
pipes. These are mainly used for cleaning purpose.
Salient Features
Capacity : 15Litres
Power : 230 Volt (+/-10%), 50 Hz (+/-3%)
Heating element : 2x1500 Watt tube type immersion
heating element
Thermostat : 40-110°C
DIM. : 725 x 370 x 380mm
IRCAMTECH/GWL/ELECT/2022-23//LHB/Manual/1.1 Page 3 of 11
Revised LHB Maintenance Manual (Electrical) Chapter 09
Soup Warmer
Soup Warmer is divided in two major parts i.e. food insert and kettle insert. It is
meant to keep warm and warm up the pre-mixed soup in the food insert. The
heating medium is water which is to be filled between food insert and kettle
insert. The lid should be kept close to prevent water loss. It is to be opened
when refilling of food insert is required. Don’t operate the kettle in dry condition.
Always turn the kettle control ‘OFF’ when not in use.
Salient Features
Capacity - a. Food insert – 10-11 litres.
Maximum power - 500 watts.
Nominal voltage - 230 V ± 10%, 50 Hz50 Hz ±3%
Thermostat range - 60-90°C
Thermal insulation - Bonded mineral wool
14.2 COMPOSITE PANTRY EQUIPMENT FOR LHB TYPE & GARIB RATH EOG
COACHES
Hot Case
Hot case is meant to keep warm and warm up pre-cooked dishes in casseroles.
Vegetarian and non-vegetarian dishes can be kept warm separately. In order to
fulfill this requirement, hot case is divided into 3 separate parts.
IRCAMTECH/GWL/ELECT/2022-23//LHB/Manual/1.1 Page 4 of 11
Revised LHB Maintenance Manual (Electrical) Chapter 09
Salient Features
Dimensions : 1190 x 750 x505 (465+40)mm
Power Supply : 230 Volt (+/-10%), 50 Hz (+/-3%)
Heating element : 2 x 500 Watt
Hot air blower : 240 Volt (+/-5%), 50 Hz
Operating temperature : 110°C
Thermostat Range : 30 – 110°C
Trays : 18 nos., 280 x 385mm stainless steel
fabricated food
Refrigerating Unit
Salient Feature
Dimension : 1190 x480 x 900 mm
Max. Power : 800 Watt (2x400 Watt)
Power Supply : 230 Volt (+/-10%), 50 Hz (+/-3%)
Thermostat range : Deep freezer -18 to -25°C
Bottle cooler 0 to + 10°C
Cooling compartment 0 to +10°C
IRCAMTECH/GWL/ELECT/2022-23//LHB/Manual/1.1 Page 5 of 11
Revised LHB Maintenance Manual (Electrical) Chapter 09
a) Deep freezer
Salient Feature
IRCAMTECH/GWL/ELECT/2022-23//LHB/Manual/1.1 Page 6 of 11
Revised LHB Maintenance Manual (Electrical) Chapter 09
Water boiler of 30 liters capacity confirming to IS: 3412 is provided along with a
control box and necessary plumbing and tap arrangement on a common base
plate. There are three nos. of such boilers provided on side wall of coach. Inlet
to one of the boilers can be used for preparing tea/ coffee. Base plate and
plumbing are suitably modified to suit provision of water filter. Other two water
boilers are connected directly to over head tank of coach with the help of flexible
pipes. These are mainly used for cleaning purpose.
Salient Features
Capacity : 15Litres
Power : 230 Volt (+/-10%), 50 Hz (+/-3%)
Heating element : 2x1500 Watt tube type immersion heating
element
Thermostat : 40-110°C
DIM. : 965 x 375 x 650mm
IRCAMTECH/GWL/ELECT/2022-23//LHB/Manual/1.1 Page 7 of 11
Revised LHB Maintenance Manual (Electrical) Chapter 09
Cooking table is divided in three parts. Cooking tables are provided with hot
plates of the reputed approved make of the following ratings:
i) 2.0 kW – total 04 nos. (2 nos. in centre table and 02 nos. in RHS table)
ii) 5 kW – total 1 nos. (1 x 2 kW centre table & 1 kW x 3 around centre plate
in LHS table).
Height of utensil base support is kept minimum to prevent heat loss through
gap.
Suitable thermal insulation is provided below heat zones to avoid overheating
of adjoining areas and prevent heat loss.
All cooking tables are provided with individual control boxes which include the
following switchgear/ control gear:
Rotary Switch - Siemens/ Salzer
Indicator – green - GS/ Allen Bradley / Teknic
ELCB - Siemens/ MDS/ L&T
Wiring schematic diagram is shown in drawing (Annexure – A) with copper bus
bar, copper wire, porcelain beads & Teflon insulated cables of suitable ratings.
Terminals for incoming and outgoing cables shall be suitable for heating
appliances and of suitable rating.
IRCAMTECH/GWL/ELECT/2022-23//LHB/Manual/1.1 Page 8 of 11
Revised LHB Maintenance Manual (Electrical) Chapter 09
Insect Killer
In modular unit of kitchen, front openable cupboards/ racks with adjustable type
shelves as shown in figures are provided. Stainless steel drawn type sinks of
following sizes are provided.
IRCAMTECH/GWL/ELECT/2022-23//LHB/Manual/1.1 Page 9 of 11
Revised LHB Maintenance Manual (Electrical) Chapter 09
Local JPO at Zonal railway level should be issued along with commercial
department considering following minimum points for proper upkeep of Pantry
Cars & Mini-pantries are as follows:
IRCAMTECH/GWL/ELECT/2022-23//LHB/Manual/1.1 Page 10 of 11
Revised LHB Maintenance Manual (Electrical) Chapter 09
Caution:
Pantry car cooking staff should take utmost care while handling with
oil. There should not be any oil spill on or near Electric hot plate as it
may cause fire.
The container of oil should be in store in pantry car only.
C Common Responsibility
1 No smoking should be allowed in pantry cars.
2 No inflammable items should be carried in pantry cars.
3 Ensure proper closing of panel doors, defective/rattling doors should
not be allowed.
4 No extra electrical equipment except standard scale should be
connected in any case. No temporary wiring for power supply to any
kitchen appliance is permitted.
5 While taking/handing over of charge, Pantry Manager and Electrical
supervisor shall ensure all above, prepare a joint handing over/taking
over sheet and keep proper records for deficiencies, if any.
IRCAMTECH/GWL/ELECT/2022-23//LHB/Manual/1.1 Page 11 of 11