A000 ARCHITECTURAL PLANS

PRELIMINARY SKETCH ONLY A001 COVER SHEET


PLANS ARE IN CONJUCTION WITH SUPPORTING DOCUMENTS
AND CLIENT VARIATIONS. SUBJECT TO CHANGE ONCE LOT A002 NOTES
SPECIFIC REPORTS & CONSTRUCTION DOCUMENTS ARE A005 SITE PLAN
IDENTIFIED/RECIEVED. A013 GROUND FLOOR PLAN
A014 FIRST FLOOR PLAN
A018 ELEVATIONS
A019 ELEVATIONS
A023 FLOOR AREA PLAN (EXTERNAL)
A024 GROSS FLOOR AREA PLAN (INTERNAL)

NOTE: UNREGISTERED PLANS


1. PENDING 10.7, S88B, BUSHFIRE REPORT &
SALINITY REPRORT

2. FURTHER ASSESSMENT REQUIRED


UPON REGISTRATION FOR BEP

3. SITE PLAN IS INDICATIVE ONLY. CONTOUR,


SPOT LEVELS, DRIVEWAY GRADIENT,
DROP EDGE BEAMS,RETAINING WALLS
AND OTHER NECESSARY INFORMATION
WILL BE UPDATED ONCE CONTOUR
PLAN IS RECEIVED.

DEVELOPER: WILLOWDALE - STOCKLAND GROWTH CENTRE:

SUPPORTING DOCUMENTS RECEIVED LOT SPECIFIC REPORTS AFFECTED RECEIVED


GREENFIELD: Yes BUSHFIRE REPORT: No No
D.A - DCP & LEP: No FLOOD REPORT: No No
AHD SURVEY: No ACOUSTICS REPORT: No No
SECTION 10.7: No HYDRAULICS: No No
SECTION 88B: No ARBORISTS REPORT: No No
CONTOUR SURVEY: No DILAPIDATION REPORT: No No
BOREHOLE REPORT: No SEWER PEG OUT: No No
13.10.21 4 NIMA SALES VARIATION REQUEST DATED 11.10.21
ENGINEERS: No SALINITY: No No
07.10.21 3 NIMA SALES VARIATION REQUEST DATED 05.10.21 STRUCTURALS: No ACID SULPHATE: No
29.09.21 2 PG INITIAL PRELIMINARY PLANS WITH AMENDMENT REQUEST DATED 17.09.21 LANDSCAPE PLAN: No RETICULATED WATER: No
17.09.21 1 PG INITIAL CONCEPT PLANS WITH SALES WITH 13.09.21
DATE REV DRAWN BY DESCRIPTION DOCUMENTS AND REPORTS ARE SUBJECT TO CHANGE
CLIENT'S NAME: SHEET NAME: JOB NO:
MR MAHESH PALETI
PTY LTD
ALL DIMENSIONS
ARE IN COVER SHEET 300019
BUILDERS LICENCE: 205 457C ABN: 481 288 211 98 MILLIMETERS.
CLIENT'S SIGNATURE DATE ALL DIMENSIONS HOUSE NAME: PROJECT STAGE: REV NO: SHEET NO:
10 Sovereign Place © COPYRIGHT ARE FRAME TO SITE ADDRESS:
South Windsor
NSW 2756. ALL RIGHTS RESERVED. This plan is the property of
I accept and understand the plans and documents that FRAME. DO NOT LOT 7183 DP:TBC CORAL 27 PRELIMINARY 4 A001
KURMOND HOMES PTY LTD. Copyright in this have been provided to me by Kurmond Homes. SCALE OFF
T: 1300 764 761
documents is owned by KURMOND HOMES PTY LTD.
Under the provisions of the Copyright ACT 1968 and is
PLANS. (No.XX) TBC FACADE NAME: PACKAGE: SCALE @ A3: DATE:

F: (02) 4577 6332


intended for use only as authorised by KURMOND
HOMES PTY LTD.
LOCATION: X:\1.JOBS\300001-300099\300019 - PALETI\300019 - PATETI - CORAL 27 - PRELIMINARY.NEW.rvt
LEPPINGTON ,NSW, 2179 VOGUE P.DIAMOND ELITE 13.10.21
PRELIMINARY SKETCH ONLY
PLANS ARE IN CONJUCTION WITH SUPPORTING DOCUMENTS
AND CLIENT VARIATIONS. SUBJECT TO CHANGE ONCE LOT
SPECIFIC REPORTS & CONSTRUCTION DOCUMENTS ARE
IDENTIFIED/RECIEVED.

GENERAL NOTES: SPECIFICATION NOTES:


COORDINATION: STAIRS: GENERAL SPECIFICATIONS: FOOTINGS AND SLABS: ROOF AND WALL CLADDING: SAFE MOVEMENT AND ACCESS:
REFER TO AND COORDINATE INFORMATION CONTAINED BALUSTRADES AND HANDRAILS, NEWEL POST, TREADS EXECUTE THE WORKS IN COMPLIANCE WITH THE DESIGN AND CONSTRUCT FOOTINGS AND SLABS:
IN THE ARCHITECTURAL DRAWINGS, AND THE AND RISERS TO STAIR MANUFACTURER'S RELEVANT DEEMED-TO-SATISFY PROVISIONS OF THE IN ACCORDANCE WITH PART 3.2 OF THE BCA (VOLUME 2) AND STAIR CONSTRUCTION:
ROOF TILING:
DOCUMENTATION OF OTHER CONSULTANTS. NOTIFY ANY SPECIFICATIONS. BUILDING CODE OF AUSTRALIA (BCA) (VOLUME 2), AS 2870-2011 (RESIDENTIAL SLABS AND FOOTINGS), AS TO BE IN ACCORDANCE WITH PART 3.9.1.1 OF THE BCA
TO BE IN ACCORDANCE WITH PARTS 3.5.1.1 & 3.5.1.2 OF
DISCREPANCIES BETWEEN THE ARCHITECTURAL AND/OR CURRENT EDITIONS OF RELEVANT AUSTRALIAN AND 3600-2001 (CONCRETE STRUCTURES) AND AS 2159-2009 (VOLUME 2) - ACCEPTABLE CONSTRUCTION PRACTICE.
THE BCA (VOLUME 2) AND AS 2049-2002 (ROOF TILES).
OTHER CONSULTANTS DOCUMENTATION PRIOR TO ROOF PLANS: OTHER APPLICABLE PUBLISHED STANDARDS AND THE (PILING-DESIGN AND INSTALLATION).
ROOF TILE INSTALLATION: TO AS 2050-2002 BALUSTRADES:
PROCEEDING WITH THE WORKS. TRADESMAN TO ENSURE THE CORRECT INSTALLATION RELEVANT REQUIREMENTS OF LOCAL AND/OR STATUTORY
(INSTALLATION OF ROOFING TILES). TO BE IN ACCORDANCE WITH PART 3.9.2.1 OF THE BCA
OF ROOF FLASHING TO JUNCTION OF BRICKWORK AND AUTHORITIES APPLICABLE TO THE EXECUTION OF THE BRICK & BLOCK CONSTRUCTION (MASONRY):
SPECIFICATIONS AND SCHEDULES: WORKS. THIS SCHEDULE OF CODES AND STANDARDS (VOLUME 2) - ACCEPTABLE CONSTRUCTION PRATICE.
CLADDING MASONRY CONSTRUCTION: TO BE IN ACCORDANCE METAL ROOF SHEETING:
REFER TO AND COORDINATE WITH APPLICABLE OUTLINES THE MINIMUM ACCEPTABLE STANDARDS. WITH PART 3.3 OF THE BCA (VOLUME 2) AND TO AS TO BE IN ACCORDANCE WITH PARTS 3.5.1.1 & 3.5.1.3 OF BLOCK AND TILE FINISHES:
SPECIFICATIONS AND SCHEDULES. NOTIFY ANY 3700-2011 (MASONRY STRUCTURES). THE BCA (VOLUME 2). CERAMIC TILING: FOLLOW THE GUIDANCE PROVIDED BY
DISCREPANCIES BETWEEN DOCUMENTS PRIOR TO CUT/ FILL PLAN: TERMITE PROTECTION: MASONRY UNITS: TO AS/NZS 4455-1997 (MASONRY METAL ROOFING DESIGN AND INSTALLATION: TO AS AS 3958.1-2007 (CERAMIC TILES - GUIDE TO THE
PROCEEDING WITH THE WORKS. REFER TO ENGINEER'S DETAILS FOR DROP EDGE PROVIDE TERMITE PROTECTION: IN ACCORDANCE WITH UNITS AND SEMENTAL PAVERS). CLAY BRICK 1562.1-1992 (DESIGN AND INSTALLATION OF SHEET INSTALLATION OF CERAMIC TILES) AND AS 3958.2-1992
BEAMS IF APPLICABLE. PART 3.1.3 - TERMITE RISK MANAGEMENT OF THE BCA DURABILITY BELOW DAMP-PROOF COURSE: USE ROOF AND WALL CLADDING-METAL). (CERAMIC TILES - GUIDE TO THE SELECTION OF A
DETAIL DRAWINGS: (VOLUME 2) AND TO AS 3660.1-200 TERMITE EXPOSURE CATEGORY TO AS/NZS 4456.10-2003
MANAGEMENT - NEW BUILDING WORK) CERAMIC TILING SYSTEM).
DRAWINGS AT LARGER SCALES TAKE PRECEDENCE (MASONRY UNITS AND SEGMENTAL PAVERS - METHODS ROOF PLUMBING: ADHESIVES: TO AS 2358-1992 (ADHESIVES - FOR FIXING
OVER DRAWINGS AT SMALLER SCALES. NOTIFY ANY BALUSTRADES PROVIDE PROFESSIONAL CERTIFICATION OF THE
ALL BALUSTRADES TO BE 1.1m FROM THE FINISHED OF TEST-DETERMINING RESISTANCE TO SALT ATTACK) TO BE IN ACCORDANCE WITH PART 3.5.2 OF THE BCA CERAMIC TILES).
DISCREPANCIES PRIOR TO PROCEEDING WITH THE TERMITE PROTECTION MEASURES TO THE PRINCIPAL APPENDIX A (SALT ATTACK RESISTANCE CATEGORIES).
FLOOR LEVEL. CERTIFTYING AUTHORITY, CONFIRMING COMPLIANCE (VOLUME 2) AND AS/NZS 3500-2003 (PART 3-STORMWATER
WORKS. WATERPROOFING:
WITH THE PROVISIONS OF THE BCA AND AUSTRALIAN DRAINAGE) AND AS/NZS 3500-2000 (PART 5-DOMESTIC
GALVANISING: TO BE IN ACCORDANCE WITH PART 3.8.1 OF THE BCA
STANDARD. INSTALLATION-SECTION 5-STORMWATER DRAINAGE).
EXECUTION OF THE WORKS: ROOF PLANS: GALVANISING MILD STEEL COMPONENTS (INCLUDING (VOLUME 2).
EXECUTE THE WORKS IN ACCORDANCE AND TRADESMAN TO ENSURE THE CORRECT INSTALLATION FASTENERS) TO AS 1214-1983 OR AS/NZS 4680-2006, AS WALL CLADDING: WATERPROOFING: TO AS 3740-2010
FLASHING AND DAMP - PROOF COURSES:
COMPLIANCE WITH: OF ROOF FLASHING TO JUNCTION OF BRICKWORK AND APPROPRIATE, WHERE EXPOSED TO WEATHER, TO BE IN ACCORDANCE WITH PART 3.5.3 OF THE BCA (WATERPROOFING OF WET AREAS IN RESIDENTIAL
FLASHING AND DAMP - PROOF COURSES: TO AS/NZS
-THE APPROVED DEVELOPMENT APPLICATION AND IN CLADDING EMBEDDED IN MASONRY OR IN CONTACT WITH (VOLUME 2). BUILDINGS).
2904-199S (DAMP PROOF COURSES AND FLASHINGS).
ACCORDANCE WITH THE RELEVANT CONDITIONS OF CHEMICALLY TREATED TIMBER. REFER TO ARCHITECTURAL DETAILS OF
CONSENT AND OTHER RELEVANT LOCAL AUTHORITY FASTENERS: INSTALLATION AND SARKING: WATERPROOFING.
REQUIREMENTS; STEEL NAILS: HOT-DIP GALVANISED TO AS/NZS 4680-1999 WALL TIES: BULK INSTALLATION: TO AS/NZS 4859.1-2002 (MATERIALS
WALL TIE TYPE: TO BCA VOLUME 2 CLAUSE 3.3.3.2 FOR THE THERMAL INSULATION OF BUILDINGS-GENERAL FLOOR COATINGS AND COVERINGS:
-THE REQUIREMENTS SCHEDULES BY A CURRENT BASIX (HOT-DIP GALVANISED (ZINC) COATINGS ON FABRICATED CARPETING: TO AS/NZS 2455.1-2007 (TEXTILE FLOOR
CERTIFICATE CONSISTENT WITH THE WORKS. FERROUS ARTICIES). SELF-DRILLING SCREWS: TO AS (ACCEPTABLE CONSTRUCTION-MASONRY-MASONRY CRITERIA AND TECHNICAL PROVISIONS), SECTION 5.
ACCESSORIES-WALL TIES) AND AS/NZS 2699.1-2000 (BUILT- REFLECTIVE INSULATION: TO AS/NZS 4859.1- 2002, COVERINGS - INSTALLATION PRACTICE - GENERAL).
-THE CURRENT EDITION OF THE BUILDING CODE OF 3566.1-2002 (SELF-DRILLING SCREWS FOR THE BUILDING RESILLENT FINISHES: TO AS 1884-2012 (FLOOR
AUSTRALIA ( AS AMENDED); AND AND CONSTRUCTION INDUSTRIES) IN COMPONENTS FOR MASONRY CONSTRUCTION-WALL SECTION 9
TIES); NON-SEISMIC AREAS: TYPE A; SEISMIC AREAS:TYPE SARKING MATERIAL: TO AS/NZS 4200.1-1994 (PLIABLE COVERINGS - RESILIENT SHEET AND TILES - LAYING AND
-CURRENT EDITIONS OF THE RELEVANT AUSTRALIAN MAINTENANCE PRACTICES).
AND OTHER APPLICABLE PUBLISHED STANDARDS METAL FINISHES: B. BUILDING MATERIALS AND UNDERLAYS-MATERIAL(S)).
RELEVANT TO THE EXECUTION OF THE WORKS. CORROSION PROTECTION: TO BCA VOLUME 2 CLAUSE WALL TIE SPACING: TO BCA VOLUME 2 FIGURE 3.3.3.1 WINDOWS AND DOORS:
3.4.2.2 (ACCEPTABLE CONSTRUCTION-FRAMING-STEEL (TYPICAL BRICK TIES SPACINGS IN CAVITY AND VENEER GLAZING TO BE IN ACCORDANCE WITH PART 3.6 OF THE PAINTING:
UNITS OF MEASUREMENT: FRAMING-GENERAL) CONSTRUCTION). BCA (VOLUME 2). PAINTING GENERALLY: FOLLOW THE GUIDANCE
DIMENSIONS ARE SHOWN IN MILLIMETRES UNLESS WALL TIE CORROSION PROTECTION: TO BCA VOLUME 2 GLASS SELECTION AND INSTALLATIONS: TO AS 1288-2006 PROVIDED BY AS/NZS 2311-2017 (GUIDE TO THE PAINTING
NOTED OTHERWISE. SITE PREPARATION: TABLE 3.3.3.1 (CORROSION PROTECTION TIES). (GLASS IN BUILDINGS-SELECTION AND INSTALLATION). OF BUILDINGS) AND AS/NZS 2312-2002 (GUIDE TO THE
LINTELS GENERALL: IN ACCORDANCE WITH PART 3.3.3.4 TIMBER DOORSETS: TO AS 2688-1984 (TIMBER DOORS). PROTECTION OF THE STRUCTURAL STEEL AGAINST
MATERIALS HANDLING AND STORAGE: DEMOLITION: ATMOSPHERIC CORROSION BY THE USE OF PROTECTIVE
OF THE BCA (VOLUME 2). TIMBER FRAMES AND JAMB LININGS: TO AS 2689-1984
MATERIAL, FIXTURES AND FITTINGS ARE TO BE DEMOLISH EXISTING STRUCTURES AS SHOWN: TO COATINGS).
(TIMBER DOORSETS).
HANDLED, STORED AND INSTALLED IN ACCORDANCE AS2601-2001 (DEMOLITION OF STRUCTURES). SECURITY SCREEN DOORS AND WINDOW GRILLES: TO
WITH THE MANUFACTURER'S CURRENT WRITTEN FIRE SAFETY: AS 5039-2008 (SECURITY SCREEN DOORS AND SECURITY
PLUMBING INSTALLATIONS:
INSTRUCTIONS. EARTHWORKS: WHERE A DISCREPANCY ARISES THE HYDRAULIC
WINDOW GRILLES). CONSULTANT'S LOCA OR STATUTORY AUTHORITY'S
TO BE CARRIED OUT IN ACCORDANCE WITH: FIRE SEPARATION: WINDOW SELECTION AND INSTALLATION: TO AS
STRUCTURE: THE REQUIREMENTS OF THE ENVIRONMENTAL TO BE IN ACCORDANCE WITH PART 3.7.1 OF THE BCA REQUIREMENTS TAKE PRECENDENCE OVER THE
FOUNDATIONS, FOOTINGS, REINFORCED CONCRETE 2047-2014 (WINDOWS IN BUILDINGS-SELECTION AND FOLLOWING STANDARDS TO THE EXTENT OF THE
PLANNING & ASSESSMENT ACT 1979; (VOLUME 2). INSTALLATION).
SLABS, RETAINING WALLS, FRAMING, BRACING, TIE- RELEVANT CONDITIONS OF THE DEVELOPMENT FIRE SEPARATION-SEPARATING WALL CONSTRUCTION: DISCREPANCY.
DOWN AND OTHER STRUCTURAL ELEMENTS ARE TO BE DOORSET INSTALLATION: TO AS 1909-1984 PLUMBING AND DRAINING PRODUCTS: TO SAA MPS2-2001
CONSENT; AND THE RELEVANT REQUIREMENTS OF PART 3.7.1.8 OF THE BCA (VOLUME 2). (INSTALLATION OF TIMBER DOORSETS).
CONSTRUCTED IN ACCORDANCE WITH THE PART 3.1.1 OF THE BCA (VOLUME 2). FIRE SEPARATION-ROOF LIGHTS: PART 3.7.1.10 OF THE (MANUAL OF AUTHORIZATION PROCEDURES FOR
STRUCTURAL ENGINEER'S DETAILS AND GARAGE DOORS: TO AS/NZS 4505-2012 (DOMESTIC PLUMBING AND DRAINAGE PRODUCTS) AND AS/NZS
BCA (VOLUME 2). GARAGE DOORS).
SPECIFICATIONS. STORMWATER DRAINAGE: REFER TO ARCHITECTURAL DETAILS OF FIRE 3718-2005 (WATER SUPPLY - TAP WARE).
PART 3.1.2 OF THE BCA (VOLUME 2) AND AS/NZS SEPARATION METHODS. STORMWATER: TO AS/NZS 3500.3-2003 (PLUMBING AND
HYDRAULICS: 3500-2000 (PART 5-DOMESTIC INSTALLATIONS-SECTION DRAINAGE - STORMWATER DRAINAGE) OR AS/NZS
STORMWATER DRAINAGE, WASTE WATER DRAINAGE, 5-STORMWATER DRAINAGE). HEALTH AND AMENITY: 3500.5-2012 (NATIONAL PLUMBING AND DRAINAGE -
SMOKE ALARMS:
FRESH WATER, GAS SUPPLY AND OTHER HYDRAULIC DOMESTIC INSTALLATIONS).
TO BE IN ACCORDANCE WITH PART 3.7.2 OF THE BCA WET AREAS:
SERVICES ARE TO BE CONSTRUCTED IN ACCORDANCE STRUCTURAL DESIGN: WASTEWATER: TO AS/NZS 3500.2-2015 (PLUMBING AND
(VOLME 2); AND AS 3786-2014 (SMOKE ALARMS). REFER TO 'WATERPROOFING'.
WITH LOCAL AUTHORITY AND HYDRAULIC ENGINEER'S FOR DETAILS OF STRUCTURAL FOOTINGS, SLABS, DRAINAGE - WASTE SERVICES) AND AS/NZS 3500.4-2015
REQUIREMENTS. FRAMING AND THE LIKE REFER TO STRUCTURAL ROOM HEIGHTS: (PLUMBING AND DRAINAGE - HEATED WATER SERVICES)
LINING: TO BE IN ACCORDANCE WITH PART 3.8.2 OF THE BCA OR AS/NZS 3500.5-2012
ENGINEERING DETAILS, TO BE PREPARED BY A
SLAB REBATES: QUALIFIED STRUCTURAL ENGINEER. PLASTERBOARD: TO AS/NZS 2588-1998 (GYPSUM (VOLUME 2). GAS: TO AS 5601-2013 (GAS INSTALLATION CODE).
ALL SLAB REBATES TO BE 160mm UNLESS OTHERWISE STRUCTURAL DESIGN IS TO BE IN ACCORDANCE WITH PLASTERBOARD).
NOTED. PLASTERBOARD INSTALLATION: TO AS/NZS 2589.1-2017 KITCHEN, SANITARY AND WASHING FACILITIES: ELECTRICAL INSTALLATIONS:
THE RELEVANT STRUCTURAL DESIGN MANUALS. TO BE IN ACCORDANCE WITH PART 3.8.3.2 AND 3.8.3.3 OF WHERE A DISCREPANCY ARRISES THE ELECTRICAL
GARAGE REBATES ARE 280mm WIDE X 15mm RECESS. (GYPSUM LININGS IN RESIDENTIAL AND LIGHT
ALL DIMENSIONS ARE TAKEN FROM EXTERNAL EDGE DRIVEWAY: COMMERCIAL CONSTRUCTION-APPLICATION AND THE BCA (VOLUME 2). CONSULTANT'S, LOCAL OR STATUTORY AUTHORITY'S
OF BRICK WALL. DRIVEWAY TO BE IN ACCORDANCE WITH AS 2890.1.2004 FINISHING-GYPSUM PLASTERBOARD) LEVEL 4 FINISH. REQUIREMENTS TAKE PRECEDENCE OVER THE
NATURAL AND ARTIFICIAL LIGHT: FOLLOWING STANDARDS TO THE EXTEN OF THE
FIBRE CEMENT: TO AS/NZS 2908.2-2000 (CELLULOSE-
SITE CLASSIFICATION: TO BE IN ACCORDANCE WITH PARTS 3.8.4.2 AND 3.8.4.3 DISCREPANCY
WET AREAS: CEMENT PRODUCTS-FLAT SHEETS), TYPE B, CATGEORY
TO BE IN ACCORDANCE WITH PART 3.2.4 OF THE BCA OF THE BCA (VOLUME 2). ELECTRICAL INSTALLATION: TO AS/NZS 3018-2001
FIXTURES SHOWN ARE FOR ILLUSTRATION PURPOSES 2.
(VOLUME 2) FIBROUS PLASTER PRODUCTS: TO AS 2185-1978 VENTILATION: (ELECTRICAL INSTALLATION - DOMESTIC INSTALLATIONS).
ONLY. ALL SIZES DEPICTED MAY VARY DEPENDING ON
(FIBROUS PLASTER PRODUCTS). TO BE IN ACCORDANCE WITH PART 3.8.5 OF THE BCA SMOKE DETECTORS: REFER TO "FIRE SAFETY, SMOKE
AVAILABILITY AND PRODUCT SELECTION. HEIGHT OF STRUCTURAL DESIGN MANUALS:
(VOLUME 2). ALARMS"
TILES MAY VARY ACCORDING TO SELECTION OF TILES. AS 1170.1-2002 (DEAD AND LIVE LOADS AND LOAD
F.W. LOCATION IS DIAGRAMATIC ONLY AND POSITION COMBINATIONS) TIMBER & STEEL FRAMED CONSTRUCTION: NATURAL VENTILATION: PARTS 3.8.5.2 AND 3.8.5.3 OF THE SMOKE DETECTION INSTALLATION AND TESTING:
BCA (VOLUME 2). TO AS 1670.1-2004 (FIRE DETECTION, WARNING,
MAY VARY. ALL FIXTURES SHOWN ARE BASED ON AS 1170.2-2002 (AS 4055 (1992) - WIND LOADS)
MECHANICAL VENTILATION: PARTS 3.8.5.0 AND 3.8.5.3 OF CONTROL AND INTERCOM SYSTEMS - SYSTEM DESIGN,
STANDARD INCLUSIONS. MEASUREMENTS MAY VARY AS 1170.4- 2007 (EARTHQUAKE LOADS) SUB-FLOOR VENTILATION:
THE BCA (VOLUME 2). INSTALLATION, AND COMMISSIONING - FIRE) IN
AS PER THE AVAILABILITY AND PRODUCT SELECTION. AS 1720.1-2010 (TIMBER STRUCTURES CODE) TO BE IN ACCORDANCE WITH PART 3.4.1 OF THE BCA ACCORDANCE WITH THE REQUIREMENTS OF THE
AS 2159-2009 (PILING-DESIGN AND INSTALLATION) (VOLUME 2). SOUND INSULATION: BUILDING CODE TO MAINS POWER.
AS 2327.1-2017 (COMPOSITE STRUCTURES)
MEASUREMENTS: TO BE IN ACCORDANCE WITH PART 3.8.6.1 OF THE BCA TEST ELECTRICAL INSTALLATIONS: TO AS/NZS 3017-2007
AS 3600-2009 (CONCRETE STRUCTURES) TIMBER WALL, FLOOR AND ROOF FRAMING:
ALL MEASUREMENTS ARE TAKEN FRAME TO FRAME (VOLUME 2). (ELECTRICAL INSTALLATIONS - TESTING GUIDELINES).
AS 4100-1998 (STEEL STRUCTURES) TIMBER FRAMING: TO BE IN ACCORDANCE WITH PART 3.4
AND TO FINISH FLOOR LEVEL. NO CONSIDERATION OF CERTIFY COMPLIANCE WITH AS/NZS 3018-2007.
FLOOR FINISH HAVE BEEN TAKEN. WHERE NEEDED, OF THE BCA (VOLUME 2) AND AS 1684.4-2010 (RESIDENTIAL
STRUCTURAL DESIGN CERTIFICATION: TIMBER-FRAMED CONSTRUCTION-SIMPLIFIED-NON-
MEASUREMENTS MAY NEED TO BE ACCOUNTED FOR MECHANICAL INSTALLATIONS:
SUBMIT STRUCTURAL ENGINEER'S DESIGN CYCLONIC) OR AS 1720.1-2010 (TIMBER STRUCTURES-
FINISH ONTOP OF CURRENT DIMENSION. MECHANICAL VENTILATION: TO AS 1668.2-2012 (THE USE
CERTIFICATION, IN ACCORDANCE WITH LOCAL DESIGN METHODS). OF VENTILATION AND AIR CONDITIONING IN BUILDINGS -
AUTHORITY REQUIREMENTS, THE PRINCIPAL CERTIFYING
MECHANICAL VENTILATION FOR ACCEPTABLE INDOOR
AUTHORITY PRIOR TO THE COMMENCEMENT OF WORKS.
CONSULTANTS: STEEL FRAMING AND STRUCTURAL STEEL MEMBERS: QUALITY) - GRADE 2 AMENITY.
ALL RELEVANT CONSULTANT DRAWINGS TO BE CONCRETE CONSTRUCTION: STEEL FRAMING: TO BE IN ACCORDANCE WITH PART 3.4.2
REFFERED BACK TO ORIGINAL DRAWINGS PROVIDED. CONCRETE STRUCTURES GENERALLY: TO AS OF THE BCA (VOLUME 2).
3600-2009 (CONCRETE STRUCTURES), GROUND SLABS ACCEPTABLE CONSTRUCTION PRACTICE (PART 3.4.2.1 OF
DOOR JAMBS: AND FOOTINGS: TO AS 2870-2011 (RESIDENTIAL SLABS THE BCA) AND/OR AS 4100-1998 (STEEL STRUCTURES)
MINIMUM 105mm BETWEEN DOOR JAMB AND WALL, AND FOOTINGS-CONSTRUCTION). COLD-FORMED STEEL FRAMING: PROVIDE A PROPRIETRY
WHERE MINIMUM DIMENSION CANNOT BE ACHIEVED, READY MIXED SUPPLY: TO AS 1379-2007 SYSTEM DESIGNED TO AS 3623-1993 (DOMESTIC METAL
DOOR TO BE CENTERED BETWEEN WALLS. (SPECIFICATION AND SUPPLY OF CRETE). FRAMING).

CLIENT'S NAME: SHEET NAME: JOB NO:


MR MAHESH PALETI
PTY LTD
ALL DIMENSIONS
ARE IN NOTES 300019
BUILDERS LICENCE: 205 457C ABN: 481 288 211 98 MILLIMETERS.
CLIENT'S SIGNATURE DATE ALL DIMENSIONS HOUSE NAME: PROJECT STAGE: REV NO: SHEET NO:
10 Sovereign Place © COPYRIGHT ARE FRAME TO SITE ADDRESS:
South Windsor
NSW 2756. ALL RIGHTS RESERVED. This plan is the property of
I accept and understand the plans and documents that FRAME. DO NOT LOT 7183 DP:TBC CORAL 27 PRELIMINARY 4 A002
KURMOND HOMES PTY LTD. Copyright in this have been provided to me by Kurmond Homes. SCALE OFF
T: 1300 764 761
documents is owned by KURMOND HOMES PTY LTD.
Under the provisions of the Copyright ACT 1968 and is
PLANS. (No.XX) TBC FACADE NAME: PACKAGE: SCALE @ A3: DATE:

F: (02) 4577 6332


intended for use only as authorised by KURMOND
HOMES PTY LTD.
LOCATION: X:\1.JOBS\300001-300099\300019 - PALETI\300019 - PATETI - CORAL 27 - PRELIMINARY.NEW.rvt
LEPPINGTON ,NSW, 2179 VOGUE P.DIAMOND ELITE 13.10.21
WIND CLASSIFICATION: "TBC"
PRELIMINARY SKETCH ONLY SLAB CLASSIFICATION: "TBC"
PLANS ARE IN CONJUCTION WITH SUPPORTING DOCUMENTS
AND CLIENT VARIATIONS. SUBJECT TO CHANGE ONCE LOT PROPERTY DESCRIPTION
SPECIFIC REPORTS & CONSTRUCTION DOCUMENTS ARE
IDENTIFIED/RECIEVED. LOT: 7183
D.P: UNREG
LGA: CAMPBELLTOWN
GREENFIEL HOUSING CODE
COMPLYING DEVELOPMENT CERTIFICATE
REFER TO HOUSING CODE FOR REQUIREMENTS.

SITE CALCULATIONS
SITE AREA 280.00 m²
N LOT WIDTH 10m
O 12.71 m²
5770 R BALCONY AREA
TH GROSS FLOOR AREA
GARAGE SETBACK *GARAGE G.F.A EXCLUDES 1 CAR PARKING SPACE
(18m²)
*EXCLUDES: BASEMENTS, STORAGE, VEHICLE
PROPOSED S ACCESS, TERRACES & BALCONIES WITH OUTER WALLS

KERB
DRIVEWAY OUTLINE <1.4M HIGH AND VOIDS
BY KURMOND HOMES
GROUND FLOOR G.F.A: 100.39 m²
S

98
APPROX. LOCATION OF SEWER LINE 91.83 m²
FIRST FLOOR G.F.A:

98.25
.5
OUTLINE OF GARAGE G.F.A: 18.63 m² - 1xCAR SPACE = 0.00 m²

98.00

SIDE GF
CROSSOVER
28m GROSS FLOOR AREA TOTAL: 192.22 m²

SIDE FF
D.E.B - A

120
500

CROSSOVER

1100
LOCATION OF
500
210.00 m²

DP
RAINWATER TANK NGL 98.45 NGL 98.28 MAX. GROSS FLOOR AREA:

S
DP DP FILL -50
DP & FILL -225
GARAGE

2880
SPREADER FGL 98.500 LANDSCAPE

ROAD 164
NGL 98.65 FGL 98.500
CUT +150
-75 -75
FFL 98.735 GROUND FLOOR: 111.46 m²
FGL 98.500
FGL 98.500 DP NGL 98.16 GARAGE: 20.82 m²
FILL -340

S
6.81 m²
98

FGL 98.500 PORCH/VERANDAH:


-75
SPREADER
.7

FRONT LANDSCAPE AREA ALFRESCO: 13.77 m²


DP &
5

CUT FILL
10m

SHOULD BE MINIMUM 50%


152.86 m²

10m
122.80 m² 88.73 m² PROPOSED FOOTPRINT:
OF THE FRONT YARD AREA.
DPNGL 98.75 FFL +/- 100mm EXISTING STRUCTURES: 0.00 m²

S
3280 CUT +250
FGL 98.500 DRIVEWAY / PATHWAY: 16.07 m²
ARTICULATION ZONE

98
NGL 98.75
REAR GF CUT +250 AREA =15 m2 LANDSCAPE LESS THAN 1.5m WIDE: 0.69 m²

.5
RW TAP FGL 98.500 ARTICULATION ZONE
G TAP NGL 98.48 ENCROACHMENT AREA = FRONT YARD LANDSCAPING: 27.46 m²
DP DP HWS DP METER BOX DP FILL -20

S
3.7m2 (=24%). REAR YARD LANDSCAPING: 82.92 m²

G TAP
FGL 98.500
(A) TOTAL LANDSCAPE AREA: 110.38 m²
28m LOCATION OF METER LANDSCAPE MINIMUM: 28.00 m²
LOCATION OF AC UNIT LOCATION OF HWS
BOX

S
PRIVATE OPEN SPACE
PRINCIPAL PRIVATE OPEN SPACE: 16.00 m²
PRIVATE OPEN SPACE: 64.70 m²
(A) : EASEMENT FOR MAINTENCE 0.9m. PRINCIPAL PRIVATE OPEN SPACE MINIMUM: 16m²
3830
PROPOSED DEVELOPMENT
PORCH SETBACK
PRIVATE OPEN SPACE
NOTES:
1. BEARINGS AND DISTANCES ARE BY TITLE AND/OR DEED ONLY.
THIS DETAIL SURVEY IS NOT A "SURVEY" AS DEFINED BY THE SURVEYORS ACT
1929. IF ANY CONSTRUCTION IS PLANNED IT WOULD BE ADVISABLE TO CARRY OUT
EXTERNAL DROP EDGE FURTHER SURVEY WORK TO DETERMINE THE BOUNDARY DIMENSIONS.
2. RELATIONSHIP OF IMPROVEMENTS TO BOUNDARIES IS DIAGRAMMATIC ONLY.
BEAM AREA WHERE OFFSETS ARE CRITICAL THEY SHOULD BE CONFIRMED BY FURTHER
SURVEY.
A 3.84 m² 3. CONTOURS SHOWN DEPICT THE TOPOGRAPHY, EXCEPT AT SPOT LEVELS
SHOWN, THEY DO NOT REPRESENT THE EXCAT LEVEL AT ANY PARTICULAR POINT.
TOTAL 3.84 m² 4. SERVICES SHOWN HEREON HAVE BEEN DETERMINED FROM VISUAL EVIDENCE
ONLY. PRIOR TO ANY DEMOLITION, EXCAVATION, OR CONSTRUCTION ON THE SITE
DRIVEWAY AREA THE RELEVANT AUTHORITY SHOULD BE CONTACTED TO ESTABLISH DETAILED
LOCATION AND DEPTH.
5. AUSTRALIAN HEIGHT DATUM WAS ESTABLISH FROM SSM 168755 RL 69.056.
DRIVEWAY 16.62 m² 6. TREE LOCATIONS ARE ACCURATE TO +/- 0.30m.
7. THE INFORMATION IS ONLY TO BE USED AT A SCALE ACCURACY OF 1:200M.
CROSSOVER AREA
CROSSOVER 8.93 m²
NOTE:
SITE PLAN IS INDICATIVE ONLY. CONTOUR, ROOF SCHEDULE
SPOT LEVELS, DRIVEWAY GRADIENT, BAL TBA
DROP EDGE BEAMS, RETAINING WALLS HOUSE TO BE CONSTRUCTED TO MARK AREA TYPE
AND OTHER NECESSARY INFORMATION COMPLY WITH THE RELEVANT ROOF A 162.22 m² CONCRETE TILES
WILL BE UPDATED ONCE CONTOUR REQUIREMENTS WITHIN AS 3959-2009 ROOF B 14.25 m² COLORBOND ROOF
PLAN IS RECEIVED. ROOF C 19.92 m² CONCRETE TILES
BUSHFIRE CONSTRUCTION TOTAL 196.39 m²
CLIENT'S NAME: SHEET NAME: JOB NO:
MR MAHESH PALETI
PTY LTD
ALL DIMENSIONS
ARE IN SITE PLAN 300019
BUILDERS LICENCE: 205 457C ABN: 481 288 211 98 MILLIMETERS.
CLIENT'S SIGNATURE DATE ALL DIMENSIONS HOUSE NAME: PROJECT STAGE: REV NO: SHEET NO:
10 Sovereign Place © COPYRIGHT ARE FRAME TO SITE ADDRESS:
South Windsor
NSW 2756. ALL RIGHTS RESERVED. This plan is the property of
I accept and understand the plans and documents that FRAME. DO NOT LOT 7183 DP:TBC CORAL 27 PRELIMINARY 4 A005
KURMOND HOMES PTY LTD. Copyright in this have been provided to me by Kurmond Homes. SCALE OFF
T: 1300 764 761
documents is owned by KURMOND HOMES PTY LTD.
Under the provisions of the Copyright ACT 1968 and is
PLANS. (No.XX) TBC FACADE NAME: PACKAGE: SCALE @ A3: DATE:

F: (02) 4577 6332


intended for use only as authorised by KURMOND
HOMES PTY LTD.
LOCATION: X:\1.JOBS\300001-300099\300019 - PALETI\300019 - PATETI - CORAL 27 - PRELIMINARY.NEW.rvt
LEPPINGTON ,NSW, 2179 VOGUE P.DIAMOND ELITE 1 : 200 13.10.21
PRELIMINARY SKETCH ONLY
PLANS ARE IN CONJUCTION WITH SUPPORTING DOCUMENTS
AND CLIENT VARIATIONS. SUBJECT TO CHANGE ONCE LOT
SPECIFIC REPORTS & CONSTRUCTION DOCUMENTS ARE NOTE:
IDENTIFIED/RECIEVED.
• ALL SQUARE SET OPENINGS & ALCOVES TO
BE 2350mm HIGH TO 2750mm HIGH CEILING.
• ALL SQUARE SET OPENINGS & ALCOVES TO
BE 2200mm HIGH TO 2450mm HIGH CEILINGS.
• ALL TV NICHES & CUTOUTS TO BE 1000mm
FROM FLOOR & 1350mm HIGH TO 2750mm
HIGH CEILING
• ALL TV NICHES & CUTOUTS TO BE 1000mm
FROM FLOOR & 1200mm HIGH TO 2450mm
HIGH CEILING
• REFER TO WET AREA DETAILS FOR SHOWER
NICHE DETAILS
• ALL INTERNAL DOOR HEIGHTS AS
INDICATED ON THE DOOR SCHEDULE.
• W.I.P SHELF HEIGHT=1716 WITH 4 SHELVES
• LINEN SHELF HEIGHT=1716 WITH 4 SHELVES

N
O
20890 • W.I.R SHELF HEIGHT=1966 WITH SINGLE

R
TH
OVERALL SHELF & SINGLE RAIL
3000 5640 10310 1080 860 • ROBE SHELF HEIGHT=1716 WITH SINGLE
SHELF & SINGLE RAIL
• ROBE SHELF HEIGHT=1966 WITH SINGLE
SHELF & DOUBLE RAIL
• WINDOWS TO HAVE PROTECTION OF
350 x 350
OPENABLE WINDOWS TO COMPLY WITH THE
BRICKWORK BUILDING CODE OF AUSTRALIA VOLUME 2
610 350

DP

470
COLD WATER POINT

AAT 21/06
COLUMN 2013. IN RELATION TO THE BEDROOM
960

WINDOWS.
W02

W 02
DP DP • ALFRESCO & PORCH TO HAVE 20mm FALL
AWAY FROM THE BUILDING.

FIRST FLOOR ABOVE


FIRST FLOOR ABOVE
• R3.0 CEILING INSULATION, R2.0 WALL
1190

WS
MEDIA

2410_PD

2410
GARAGE

D02
FS. WS INSULATION AND R1.5 GARAGE CEILING
3.87 X 3.32

D02
5.87 X 3.00 INSULATION AS PER BASIX CERTIFICATE.
KITCHEN

720 CSD #
-75 RL +98.735 m

4800
WIP
4.39 X 2.45 1.07 X 2.36
ALFRESCO DP
LEGEND

D11
ASD 21/24-2

590 x 350

-75

590
3.00 X 4.59 DWP MWP D10
800
SD03
2410

WS BRICKWORK
SD 03

820 # STORE MWP MICROWAVE PROVISION


RL +98.735 m -75 COLUMN
PORCH

1100 SQ SET
OVERALL

OVERALL
1200 SQ SET
2710 ENTRY DWP DISHWASHER PROVISION

1200
D01

D01
8390

8390
1.94 X 5.51
HALL 2.56 X 1.62
1200 #
RL +98.735 m WMS WASHING MACHINE SPACE
7430

710 130
D04 710 x 350 FS FRIDGE SPACE
1190

D06 820 #

LINEN
STORE
D07 D09 820 # MOROKA FINISH
820 # 820 # COLUMN RD ROLLER DOOR
DP
FAMILY DINING UP
D08 PDR PD PANELIFT DOOR
4.33 X 4.48 2.72 X 4.48 820 # 1.66 X 3.29
AST 18/18

350 x 350 L'DRY BED 5 #

SV 900

AAT 18/22
2340 HIGH DOORS

2170

3590
W01
1810

BRICKWORK 1.79 X 2.10


W04

W 04

COLUMN FW 3.64 X 3.09

W 01
ROBE
SA SMOKE ALARM
FW

WMS
1660
D05
2 x 720 # EXHAUST FAN

1000
RW TAP 710 x 350
830

FLOOR JOIST DIRECTION

710
G TAP MOROKA FINISH
COLUMN G TAP GARDEN TAP LOCATION
DP DP D03 HWS DP METER BOX DP
W 05 820 LDR W 06
R TAP RAINWATER TAP LOCATION

G TAP
AST 18/18 AS 06/09
OBSCURED
A/C UNIT DP DOWN PIPE LOCATION

3000 5030 1810 2870 820 1340 850 4310 860 FW FLOOR WASTE
W05 D03 W06 WS WASTE STACK
3000 17030 860
AJ ARTICULATION JOINTS
20890 RA ROOF ACCESS
OVERALL
SC STRUCTURAL COLUMN
TO ENGINEER'S DETAIL
SB STRUCTURAL BEAMS TO
ENGINEER'S SPECIFICATIONS

TB TIMBER BEAMS TO ROOF/ FLOOR


MANUFACTURERS SPECS.

FLOOR AREAS
GROUND FLOOR 111.46 m²
FIRST FLOOR 100.51 m²
GARAGE 20.82 m²
PORCH 6.81 m²
ALFRESCO 13.77 m²
STAIR VOID 4.71 m²
BALCONY 12.71 m²
Grand total 270.79 m²
CLIENT'S NAME: SHEET NAME: JOB NO:
MR MAHESH PALETI
PTY LTD
ALL DIMENSIONS
ARE IN GROUND FLOOR PLAN 300019
BUILDERS LICENCE: 205 457C ABN: 481 288 211 98 MILLIMETERS.
CLIENT'S SIGNATURE DATE ALL DIMENSIONS HOUSE NAME: PROJECT STAGE: REV NO: SHEET NO:
10 Sovereign Place © COPYRIGHT ARE FRAME TO SITE ADDRESS:
South Windsor
NSW 2756. ALL RIGHTS RESERVED. This plan is the property of
I accept and understand the plans and documents that FRAME. DO NOT LOT 7183 DP:TBC CORAL 27 PRELIMINARY 4 A013
KURMOND HOMES PTY LTD. Copyright in this have been provided to me by Kurmond Homes. SCALE OFF
T: 1300 764 761
documents is owned by KURMOND HOMES PTY LTD.
Under the provisions of the Copyright ACT 1968 and is
PLANS. (No.XX) TBC FACADE NAME: PACKAGE: SCALE @ A3: DATE:

F: (02) 4577 6332


intended for use only as authorised by KURMOND
HOMES PTY LTD.
LOCATION: X:\1.JOBS\300001-300099\300019 - PALETI\300019 - PATETI - CORAL 27 - PRELIMINARY.NEW.rvt
LEPPINGTON ,NSW, 2179 VOGUE P.DIAMOND ELITE 1 : 100 13.10.21
PRELIMINARY SKETCH ONLY
PLANS ARE IN CONJUCTION WITH SUPPORTING DOCUMENTS
AND CLIENT VARIATIONS. SUBJECT TO CHANGE ONCE LOT
SPECIFIC REPORTS & CONSTRUCTION DOCUMENTS ARE NOTE:
IDENTIFIED/RECIEVED.
• ALL SQUARE SET OPENINGS & ALCOVES TO
BE 2350mm HIGH TO 2750mm HIGH CEILING.
• ALL SQUARE SET OPENINGS & ALCOVES TO
BE 2200mm HIGH TO 2450mm HIGH CEILINGS.
• ALL TV NICHES & CUTOUTS TO BE 1000mm
FROM FLOOR & 1350mm HIGH TO 2750mm
HIGH CEILING
• ALL TV NICHES & CUTOUTS TO BE 1000mm
FROM FLOOR & 1200mm HIGH TO 2450mm
HIGH CEILING
• REFER TO WET AREA DETAILS FOR SHOWER
NICHE DETAILS
• ALL INTERNAL DOOR HEIGHTS AS
INDICATED ON THE DOOR SCHEDULE.
18050
• W.I.P SHELF HEIGHT=1716 WITH 4 SHELVES
OVERALL • LINEN SHELF HEIGHT=1716 WITH 4 SHELVES

N
O
5630 8640 160 3620 • W.I.R SHELF HEIGHT=1966 WITH SINGLE

R
TH
SHELF & SINGLE RAIL
830 1810 900 610 400 850 230 1320 1810 2270 1210 2030 160 3620 • ROBE SHELF HEIGHT=1716 WITH SINGLE
SHELF & SINGLE RAIL
W14 W13 W12 W11 W10
• ROBE SHELF HEIGHT=1966 WITH SINGLE
SHELF & DOUBLE RAIL
• WINDOWS TO HAVE PROTECTION OF
W 13 W 12 OPENABLE WINDOWS TO COMPLY WITH THE
W 14 AS 09/06 AS 12/09 W 11 W 10
AS 06/18 OBSCURED OBSCURED AS 12/18 AA 06/12 BUILDING CODE OF AUSTRALIA VOLUME 2
DP DP & DP &
OBSCURED 2013. IN RELATION TO THE BEDROOM

630 160

160
SPREADER SPREADER
WINDOWS.

5
830

WC 1600 ENS • ALFRESCO & PORCH TO HAVE 20mm FALL

IT NOOK
18

0.95 X 1.80 FREESTANDING 2.59 X 3.31 AWAY FROM THE BUILDING.


BATH 110 x 110 TIMBER • R3.0 CEILING INSULATION, R2.0 WALL

AA 06/12
BATH POST

1210
INSULATION AND R1.5 GARAGE CEILING

W09
FW
AS 12/18

W 09
DV 1500
1.88 X 3.42 INSULATION AS PER BASIX CERTIFICATE.
1810

BED 3 BED 4
W15

W 15

FW DP

SV 900
WIR

3815
590 x 350
18 3.03 X 3.08 D19
FW 3.02 X 3.51 1.37 X 3.31

590
BRICKWORK
720 D18 COLUMN LEGEND

ROBE
2 x 620
D21 820

AA 14/09
1590
D20 HALL

D16
950
2 x 520

W08
850
820

W 08
MWP MICROWAVE PROVISION
SPREADER

110 x 110 TIMBER

950
D
OVERALL

OVERALL
LINEN
DP &

930 POST DWP DISHWASHER PROVISION


7430

2150

7430
D13 D14
D D
D

335 535
ROBE ROBE D15 720 820
820 710 x 350 WMS WASHING MACHINE SPACE
18

D17 D12 MOROKA FINISH


D23 FW
2 x 520 820 COLUMN FS FRIDGE SPACE
2 x 520 D22
820
RD ROLLER DOOR
BALCONY

ASD 21/24-2
UP

SD07
2410
BED 2 SITTING MASTER BED 3.62 X 3.18 PD PANELIFT DOOR
1810

3455
W16

SD 07
AS 12/18

3.03 X 3.08 4.01 X 3.33 4.69 X 3.53 RL +101.735 m


W 16

110 x 110 TIMBER # 2340 HIGH DOORS


-150 POST
SA SMOKE ALARM
710 x 350
830

710
EXHAUST FAN

D
MOROKA FINISH
COLUMN FLOOR JOIST DIRECTION
DP DP DP DP
W 17 W 18 W 19
AS 06/18 AS 06/22 FIX 14/06 G TAP GARDEN TAP LOCATION
1.7m PRIVACY
SCREEN BY OWNER R TAP RAINWATER TAP LOCATION

830 1810 1670 2170 1550 600 5800 3620 DP DOWN PIPE LOCATION

W17 W18 W19 FW FLOOR WASTE


14430 3620
WS WASTE STACK
18050 AJ ARTICULATION JOINTS
OVERALL
RA ROOF ACCESS

SC STRUCTURAL COLUMN
TO ENGINEER'S DETAIL
SB STRUCTURAL BEAMS TO
ENGINEER'S SPECIFICATIONS

TB TIMBER BEAMS TO ROOF/ FLOOR


MANUFACTURERS SPECS.

FLOOR AREAS
GROUND FLOOR 111.46 m²
ROOF SCHEDULE FIRST FLOOR 100.51 m²
GARAGE 20.82 m²
MARK AREA TYPE PORCH 6.81 m²
ROOF A 162.22 m² CONCRETE TILES ALFRESCO 13.77 m²
ROOF B 14.25 m² COLORBOND ROOF STAIR VOID 4.71 m²
ROOF C 19.92 m² CONCRETE TILES BALCONY 12.71 m²
TOTAL 196.39 m² Grand total 270.79 m²
CLIENT'S NAME: SHEET NAME: JOB NO:
MR MAHESH PALETI
PTY LTD
ALL DIMENSIONS
ARE IN FIRST FLOOR PLAN 300019
BUILDERS LICENCE: 205 457C ABN: 481 288 211 98 MILLIMETERS.
CLIENT'S SIGNATURE DATE ALL DIMENSIONS HOUSE NAME: PROJECT STAGE: REV NO: SHEET NO:
10 Sovereign Place © COPYRIGHT ARE FRAME TO SITE ADDRESS:
South Windsor
NSW 2756. ALL RIGHTS RESERVED. This plan is the property of
I accept and understand the plans and documents that FRAME. DO NOT LOT 7183 DP:TBC CORAL 27 PRELIMINARY 4 A014
KURMOND HOMES PTY LTD. Copyright in this have been provided to me by Kurmond Homes. SCALE OFF
T: 1300 764 761
documents is owned by KURMOND HOMES PTY LTD.
Under the provisions of the Copyright ACT 1968 and is
PLANS. (No.XX) TBC FACADE NAME: PACKAGE: SCALE @ A3: DATE:

F: (02) 4577 6332


intended for use only as authorised by KURMOND
HOMES PTY LTD.
LOCATION: X:\1.JOBS\300001-300099\300019 - PALETI\300019 - PATETI - CORAL 27 - PRELIMINARY.NEW.rvt
LEPPINGTON ,NSW, 2179 VOGUE P.DIAMOND ELITE 1 : 100 13.10.21
"M" SLAB PLATFORM DETAIL
PRELIMINARY SKETCH ONLY
PLANS ARE IN CONJUCTION WITH SUPPORTING DOCUMENTS PROPOSED BUILDING
OUTLINE
AND CLIENT VARIATIONS. SUBJECT TO CHANGE ONCE LOT
SPECIFIC REPORTS & CONSTRUCTION DOCUMENTS ARE CEILING LEVEL
IDENTIFIED/RECIEVED.
150mm BATTERED BACKFILL
TO TOE OF SLAB FROM
BUILDING PLATFORM
(CENTRE LINE)
RIDGE RL 106.191
EXCAVATION BUILDING
SELECTED ROOF PLATFORM (SOLID LINE)
TILES
SELECTED QUAD
22.5 FLOOR LEVEL
FASCIA & GUTTER 450 450 610
FIRST CEILING RL 104.485
NATURAL GROUND LEVEL
SELECTED LIGHT (DASHED)
SELECTED

WINDOW HEIGHT
BRICKWORK WEIGHT CLADDING
SD 07

O/A BUILDING HEIGHT

2600
110 x 110 TIMBER ASD 21/24-2 W 08 W 10

2182
POST AA 14/09 AA 06/12
OBSCURED
SELECTED GLASS

7691
BALUSTRADE
FIRST FLOOR RL 101.885 5
GROUND CEILING RL 101.560 GROUND CEILING RL 101.560
SELECTED SELECTED
BRICKWORK BRICKWORK

GARAGE DOOR HEIGHT


WINDOW HEIGHT
710 x 350

3613
MOROKA FINISH

2750

2825
COLUMN W 01 D01
D02

2154

2154
AAT 18/22 1200 #

BOUNDARY
BOUNDARY
2410_PD

(A)
GROUND FLOOR RL 98.810 GARAGE FLOOR RL 98.735

75
310

235
NGL 98.48
FILL -20
FGL 98.500 NGL 98.16 NGL 98.28
FILL -340 FILL -225
AC & RWT 710 x 350 590 x 350
FGL 98.500 FGL 98.500
BRICKWORK
NORTH ELEVATION BEHIND
EASEMENT
MOROKA FINISH
COLUMN COLUMN

SCALE 1 : 100 FRONT ELEVATION


SELECTED QUAD
FASCIA & GUTTER

SELECTED
COLORBOND ROOF
RIDGE RL 106.191
SELECTED ROOF
TILES

SELECTED QUAD 22.5


FASCIA & GUTTER
450 450 450
FIRST CEILING RL 104.485

1.7m PRIVACY SELECTED


SCREEN BY OWNER BRICKWORK
WINDOW HEIGHT

W 11
O/A BUILDING HEIGHT

2600

W 10 AS 12/18 W 14
SELECTED LIGHT SELECTED ROOF
2182

WEIGHT CLADDING AA 06/12 AS 06/18 TILES


OBSCURED
W 12 W 13
18
7691

SELECTED GLASS SELECTED QUAD


AS 12/09 AS 09/06
BALUSTRADE FASCIA & GUTTER
FIRST FLOOR RL 101.885 OBSCURED OBSCURED 450
GROUND CEILING RL 101.560

SELECTED
SELECTED 450 BRICKWORK
BRICKWORK
2750

590 x 350
BRICKWORK
COLUMN

GARAGE FLOOR RL 98.735


75
310

D.E.B - A
NGL 98.45 350 x 350 NGL 98.65
NGL 98.16 NGL 98.28 FILL -50 BRICKWORK CUT +150
FILL -340 FILL -225 FGL 98.500 FGL 98.500 LOCATION OF
COLUMN
FGL 98.500 FGL 98.500 RAINWATER TANK

EAST ELEVATION
SCALE 1 : 100 SIDE ELEVATION
CLIENT'S NAME: SHEET NAME: JOB NO:
MR MAHESH PALETI
PTY LTD
ALL DIMENSIONS
ARE IN ELEVATIONS 300019
BUILDERS LICENCE: 205 457C ABN: 481 288 211 98 MILLIMETERS.
CLIENT'S SIGNATURE DATE ALL DIMENSIONS HOUSE NAME: PROJECT STAGE: REV NO: SHEET NO:
10 Sovereign Place © COPYRIGHT ARE FRAME TO SITE ADDRESS:
South Windsor
NSW 2756. ALL RIGHTS RESERVED. This plan is the property of
I accept and understand the plans and documents that FRAME. DO NOT LOT 7183 DP:TBC CORAL 27 PRELIMINARY 4 A018
KURMOND HOMES PTY LTD. Copyright in this have been provided to me by Kurmond Homes. SCALE OFF
T: 1300 764 761
documents is owned by KURMOND HOMES PTY LTD.
Under the provisions of the Copyright ACT 1968 and is
PLANS. (No.XX) TBC FACADE NAME: PACKAGE: SCALE @ A3: DATE:

F: (02) 4577 6332


intended for use only as authorised by KURMOND
HOMES PTY LTD.
LOCATION: X:\1.JOBS\300001-300099\300019 - PALETI\300019 - PATETI - CORAL 27 - PRELIMINARY.NEW.rvt
LEPPINGTON ,NSW, 2179 VOGUE P.DIAMOND ELITE 1 : 100 13.10.21
"M" SLAB PLATFORM DETAIL
PRELIMINARY SKETCH ONLY
PLANS ARE IN CONJUCTION WITH SUPPORTING DOCUMENTS PROPOSED BUILDING
OUTLINE
AND CLIENT VARIATIONS. SUBJECT TO CHANGE ONCE LOT
SPECIFIC REPORTS & CONSTRUCTION DOCUMENTS ARE CEILING LEVEL
SELECTED ROOF
IDENTIFIED/RECIEVED. TILES
150mm BATTERED BACKFILL
SELECTED QUAD TO TOE OF SLAB FROM
FASCIA & GUTTER BUILDING PLATFORM
RIDGE RL 106.191 (CENTRE LINE)
SELECTED ROOF
TILES
22.5 EXCAVATION BUILDING
PLATFORM (SOLID LINE)
SELECTED QUAD
FASCIA & GUTTER 450 450 FLOOR LEVEL
FIRST CEILING RL 104.485

SELECTED
BRICKWORK NATURAL GROUND LEVEL

WINDOW HEIGHT
(DASHED)
W 15 W 16

O/A BUILDING HEIGHT


SELECTED

2600
AS 12/18 AS 12/18

2182
COLORBOND ROOF

329
SELECTED QUAD
18

7691
FIRST FLOOR RL 101.885
FASCIA & GUTTER
5 450
GROUND CEILING RL 101.560

450
SELECTED
BRICKWORK

WINDOW HEIGHT
W 02
AAT 21/06 W 04

2750

BOUNDARY
AST 18/18

2154
SD 03

BOUNDARY

RW TAP
ASD 21/24-2

G TAP
GROUND FLOOR RL 98.810

310
NGL 98.45 NGL 98.65 NGL 98.75 NGL 98.75
350 x 350 350 x 350
FILL -50 CUT +150 CUT +250 CUT +250
FGL 98.500 FGL 98.500 BRICKWORK BRICKWORK FGL 98.500 FGL 98.500
COLUMN COLUMN
LOCATION OF AC UNIT

SOUTH ELEVATION
SCALE 1 : 100 REAR ELEVATION
RIDGE RL 106.191
SELECTED ROOF
TILES

SELECTED QUAD 22.5


FASCIA & GUTTER 450 450
FIRST CEILING RL 104.485

SELECTED 1.7m PRIVACY


BRICKWORK W 16 W 18 W 19
WINDOW HEIGHT

AS 12/18 AS 06/22 FIX 14/06 SCREEN BY OWNER


O/A BUILDING HEIGHT
2600

2182

SELECTED ROOF
TILES
18 SELECTED GLASS
7691

SELECTED QUAD BALUSTRADE


FIRST FLOOR RL 101.885 FASCIA & GUTTER 450
GROUND CEILING RL 101.560
SELECTED SELECTED
BRICKWORK BRICKWORK
WINDOW HEIGHT

710 x 350
2750

W 06 MOROKA FINISH
2154

D03 AS 06/09 COLUMN

G TAP
1640

1640
W 05 820 LDR OBSCURED
AST 18/18
GROUND FLOOR RL 98.810

NGL 98.75 NGL 98.75 NGL 98.48


CUT +250 350 x 350 CUT +250 FILL -20
FGL 98.500 BRICKWORK FGL 98.500 LOCATION OF AC UNIT FGL 98.500
LOCATION OF
COLUMN
RAINWATER TANK

WEST ELEVATION
SCALE 1 : 100 SIDE ELEVATION
CLIENT'S NAME: SHEET NAME: JOB NO:
MR MAHESH PALETI
PTY LTD
ALL DIMENSIONS
ARE IN ELEVATIONS 300019
BUILDERS LICENCE: 205 457C ABN: 481 288 211 98 MILLIMETERS.
CLIENT'S SIGNATURE DATE ALL DIMENSIONS HOUSE NAME: PROJECT STAGE: REV NO: SHEET NO:
10 Sovereign Place © COPYRIGHT ARE FRAME TO SITE ADDRESS:
South Windsor
NSW 2756. ALL RIGHTS RESERVED. This plan is the property of
I accept and understand the plans and documents that FRAME. DO NOT LOT 7183 DP:TBC CORAL 27 PRELIMINARY 4 A019
KURMOND HOMES PTY LTD. Copyright in this have been provided to me by Kurmond Homes. SCALE OFF
T: 1300 764 761
documents is owned by KURMOND HOMES PTY LTD.
Under the provisions of the Copyright ACT 1968 and is
PLANS. (No.XX) TBC FACADE NAME: PACKAGE: SCALE @ A3: DATE:

F: (02) 4577 6332


intended for use only as authorised by KURMOND
HOMES PTY LTD.
LOCATION: X:\1.JOBS\300001-300099\300019 - PALETI\300019 - PATETI - CORAL 27 - PRELIMINARY.NEW.rvt
LEPPINGTON ,NSW, 2179 VOGUE P.DIAMOND ELITE 1 : 100 13.10.21
PRELIMINARY SKETCH ONLY
PLANS ARE IN CONJUCTION WITH SUPPORTING DOCUMENTS
AND CLIENT VARIATIONS. SUBJECT TO CHANGE ONCE LOT
SPECIFIC REPORTS & CONSTRUCTION DOCUMENTS ARE
IDENTIFIED/RECIEVED.

5 ALFRESCO
13.77 m²

MWP DWP
2 FIRST FLOOR
100.51 m²

WS FS.
950

WS

950
1 GROUND FLOOR
111.46 m²
UP

UP
6 STAIR VOID
4.71 m²

930
1590

WMS

COLOUR SCHEME
1660

3 GARAGE
1000
20.82 m² GROUND FLOOR
WS

BALCONY

FIRST FLOOR
7 BALCONY
12.71 m² GARAGE

PORCH

4 PORCH ALFRESCO
6.81 m² STAIR VOID

FLOOR AREAS
GROUND FLOOR 111.46 m²
FIRST FLOOR 100.51 m²
GARAGE 20.82 m²
1. GROUND FLOOR AREA 2. FIRST FLOOR AREA PORCH 6.81 m²
ALFRESCO 13.77 m²
STAIR VOID 4.71 m²
BALCONY 12.71 m²
Grand total 270.79 m²
CLIENT'S NAME: SHEET NAME: JOB NO:
MR MAHESH PALETI
PTY LTD
ALL DIMENSIONS
ARE IN FLOOR AREA PLAN (EXTERNAL) 300019
BUILDERS LICENCE: 205 457C ABN: 481 288 211 98 MILLIMETERS.
CLIENT'S SIGNATURE DATE ALL DIMENSIONS HOUSE NAME: PROJECT STAGE: REV NO: SHEET NO:
10 Sovereign Place © COPYRIGHT ARE FRAME TO SITE ADDRESS:
South Windsor
NSW 2756. ALL RIGHTS RESERVED. This plan is the property of
I accept and understand the plans and documents that FRAME. DO NOT LOT 7183 DP:TBC CORAL 27 PRELIMINARY 4 A023
KURMOND HOMES PTY LTD. Copyright in this have been provided to me by Kurmond Homes. SCALE OFF
T: 1300 764 761
documents is owned by KURMOND HOMES PTY LTD.
Under the provisions of the Copyright ACT 1968 and is
PLANS. (No.XX) TBC FACADE NAME: PACKAGE: SCALE @ A3: DATE:

F: (02) 4577 6332


intended for use only as authorised by KURMOND
HOMES PTY LTD.
LOCATION: X:\1.JOBS\300001-300099\300019 - PALETI\300019 - PATETI - CORAL 27 - PRELIMINARY.NEW.rvt
LEPPINGTON ,NSW, 2179 VOGUE P.DIAMOND ELITE 1 : 100 13.10.21
PRELIMINARY SKETCH ONLY
PLANS ARE IN CONJUCTION WITH SUPPORTING DOCUMENTS
AND CLIENT VARIATIONS. SUBJECT TO CHANGE ONCE LOT
SPECIFIC REPORTS & CONSTRUCTION DOCUMENTS ARE
IDENTIFIED/RECIEVED.

MWP DWP
7 FIRST FLOOR GFA
6 GROUND FLOOR GFA

WS FS.
91.83 m²
100.39 m²

WS
950

950
UP UP

930
WMS
1590

8 GARAGE GFA
1660

18.63 m²
1000
WS

COLOUR SCHEME
FIRST FLOOR GFA

GARAGE GFA

GROUND FLOOR GFA

FLOOR SPACE AREA

1. GROUND FLOOR GFA 2. FIRST FLOOR GFA NAME


GROUND FLOOR GFA
AREA
100.39 m²
GARAGE GFA 18.63 m²
FIRST FLOOR GFA 91.83 m²
TOTAL 210.85 m²
CLIENT'S NAME: SHEET NAME: JOB NO:
MR MAHESH PALETI
PTY LTD
ALL DIMENSIONS
ARE IN GROSS FLOOR AREA PLAN (INTERNAL) 300019
BUILDERS LICENCE: 205 457C ABN: 481 288 211 98 MILLIMETERS.
CLIENT'S SIGNATURE DATE ALL DIMENSIONS HOUSE NAME: PROJECT STAGE: REV NO: SHEET NO:
10 Sovereign Place © COPYRIGHT ARE FRAME TO SITE ADDRESS:
South Windsor
NSW 2756. ALL RIGHTS RESERVED. This plan is the property of
I accept and understand the plans and documents that FRAME. DO NOT LOT 7183 DP:TBC CORAL 27 PRELIMINARY 4 A024
KURMOND HOMES PTY LTD. Copyright in this have been provided to me by Kurmond Homes. SCALE OFF
T: 1300 764 761
documents is owned by KURMOND HOMES PTY LTD.
Under the provisions of the Copyright ACT 1968 and is
PLANS. (No.XX) TBC FACADE NAME: PACKAGE: SCALE @ A3: DATE:

F: (02) 4577 6332


intended for use only as authorised by KURMOND
HOMES PTY LTD.
LOCATION: X:\1.JOBS\300001-300099\300019 - PALETI\300019 - PATETI - CORAL 27 - PRELIMINARY.NEW.rvt
LEPPINGTON ,NSW, 2179 VOGUE P.DIAMOND ELITE 1 : 100 13.10.21