Ethernet Interface Plug-in Card

for Alstom e-DXC


Enhanced Digital Cross-connect

User’s Manual
Version 8, October 30, 2015
Table of Contents

1. PRODUCT DESCRIPTION .................................................................................1


1.1. Application Illustration ..................................................................................................... 2
1.2. Product Specifications..................................................................................................... 3

2. INSTALLATION ..................................................................................................4
2.1. Mechanical Installation .................................................................................................... 4
2.2. Electrical Installation ....................................................................................................... 4
2.3. Configuration Setting ...................................................................................................... 4

3. OPERATION .......................................................................................................5
4. ETHERNET CARD (Without L2 Switch) SETUP PROCEDURE .......................6
4.1. Menu Tree ...................................................................................................................... 6
4.2. Initial Setup and Card Registration .................................................................................. 7
4.3. Choosing a Trib Unit ..................................................................................................... 10
4.4. Mode Setup .................................................................................................................. 11
4.5. WAN (VCG) & Link Setup ............................................................................................. 13
4.5.1. Payload/LCAS Setup ............................................................................................ 13
4.5.2. Encapsulation Type Setup .................................................................................... 14
4.5.3. Encapsulation Parameter Setup............................................................................ 15
4.5.4. Path Alarm Setup ................................................................................................. 20
4.5.5. WAN (VCG) Alarm Threshold Setup ..................................................................... 22
4.5.6. Linkdown Alarm Setup .......................................................................................... 23
4.5.7. Link Config Setup ................................................................................................. 24
4.5.8. Customer Information Setup ................................................................................. 25
4.5.9. Link Failure Propagation ....................................................................................... 26
4.5.10. Inter-Frame Gap (IFG) Setup ................................................................................ 27
4.6. Performance Setup/Clear.............................................................................................. 28
4.6.1. Clear Performance Data ....................................................................................... 28
4.6.2. Performance Threshold Setup .............................................................................. 29
4.7. File Transfer ................................................................................................................. 30
4.7.1. Unit Download Firmware....................................................................................... 30
4.8. SNCP/UPSR APS Setup............................................................................................... 31
4.8.1. SNCP/UPSR APS Command ............................................................................... 31
4.8.2. SNCP/UPSR Revertive Setup............................................................................... 32
4.9. Reset Unit ..................................................................................................................... 33
4.10. Unit Load Default .......................................................................................................... 33

5. ETHERNET CARD (With L2 Switch) SETUP PROCEDURE ..........................34


5.1. Menu Tree .................................................................................................................... 34
5.2. Initial Setup and Card Registration ................................................................................ 35
5.3. Choosing a Trib Unit ..................................................................................................... 36
5.4. Mode Setup .................................................................................................................. 38
5.5. Store/Retrieve Backup Config ....................................................................................... 39
5.6. WAN (VCG) & Link Setup ............................................................................................. 40
5.6.1. Payload/LCAS Setup ............................................................................................ 40
5.6.2. Encapsulation Type Setup .................................................................................... 41
5.6.3. Encapsulation Parameter Setup............................................................................ 42
5.6.4. Path Alarm Setup ................................................................................................. 46
5.6.5. WAN (VCG) Alarm Threshold Setup ..................................................................... 48
5.6.6. Linkdown Alarm Setup .......................................................................................... 49
5.6.7. Link Config Setup ................................................................................................. 50
5.6.8. Customer Information Setup ................................................................................. 51
5.6.9. Link Failure Propagation ....................................................................................... 51
5.5.10 Inter-Frame Gap (IFG) Setup ........................................................................................ 52
5.7. Performance Setup/Clear .............................................................................................. 53
5.7.1. Clear Performance Data ....................................................................................... 53
5.7.2. Performance Threshold Setup .............................................................................. 54
5.8. File Transfer ................................................................................................................. 55
5.8.1. Unit Download Firmware....................................................................................... 55
5.8.2. Copy Firmware to Standby Unit ............................................................................ 56
5.9. Switch Setup................................................................................................................. 56
5.9.1. VLAN Setup ......................................................................................................... 57
5.9.1.1. VLAN Tag Protocol ID Setup ......................................................................... 57
5.9.1.2. VLAN Port Configuration Setup ..................................................................... 58
5.9.1.3. VLAN Port Association Setup ........................................................................ 59
5.9.2. Port Map Setup .................................................................................................... 60
5.9.2.1. WAN PortMap Setup ..................................................................................... 60
5.9.2.2. LAN Port Map Setup ..................................................................................... 61
5.9.3. Port Trunk Setup .................................................................................................. 62
5.9.4. MSTP/RSTP Setup............................................................................................... 63
5.9.4.1. MSTP Region/CIST Setup............................................................................. 63
5.9.4.2. Spanning Tree Port Setup ............................................................................. 64
5.9.4.3. MSTP Instance/Vlan Setup ........................................................................... 65
5.9.4.4. MSTP Instance/Priority Setup........................................................................ 66
5.9.4.5. MSTP/RSTP Port Setup ................................................................................ 66
5.9.4.6. RSTP Bridge Setup ....................................................................................... 69
5.9.5. Flow Control Setup ............................................................................................... 69
5.9.6. QoS Setup............................................................................................................ 70
5.9.6.1. Class of Service Setup .................................................................................. 70
5.8.6.1.1 Priority Mode Setup ............................................................................ 71
5.8.6.1.2 Fixed Priority Setup............................................................................. 72
5.8.6.1.3 VLAN Tag Priority Setup ..................................................................... 72
5.8.6.1.4 TOS Field Priority Setup ..................................................................... 73
5.8.6.1.5 Distrusted Port Setup .......................................................................... 74
5.9.6.2. TCP/UDP Port Access Control ...................................................................... 74
5.8.6.2.1 TCP/UDP Well Known Port Setup ....................................................... 75
5.8.6.2.2 TCP/UDP User Define Port Setup ....................................................... 75
5.8.6.2.3 TCP/UDP Port Range Setup ............................................................... 76
5.9.6.3. Transmission Scheduling .............................................................................. 76
5.8.6.3.1 Scheduling Algorithm .......................................................................... 77
5.8.6.3.2 WFQ Weight Setup ............................................................................. 77
5.9.6.4. Transmission WRED Setup ........................................................................... 78
5.9.6.5. Rate Control Setup........................................................................................ 79
5.8.6.5.1 Rate Ctrl/Ingress WRED Setup ........................................................... 79
5.8.6.5.2 Port Bitrate Setup ............................................................................... 80
5.9.7. IGMP Setup.......................................................................................................... 81
5.9.7.1. IGMP Snooping............................................................................................. 81
5.9.7.2. IGMP Fast Leave .......................................................................................... 82
5.9.7.3. IGMP Router Port.......................................................................................... 83
5.9.7.4. IP Multicast Range ........................................................................................ 84
5.9.7.5. IGMP Cross Vlan I ........................................................................................ 85
5.9.7.6. IGMP Cross Vlan II ....................................................................................... 86
5.9.8. MAC Learning Setup ............................................................................................ 87
5.10. SNCP/UPSR APS Setup............................................................................................... 88
5.10.1. SNCP/UPSR APS Command ............................................................................... 88
5.10.2. SNCP/UPSR Revertive Setup............................................................................... 89
5.11. Reset Unit ..................................................................................................................... 90
5.12. Unit Load Default .......................................................................................................... 90

6. Application: ELAN Ring ..................................................................................91


6.1. Introduction ................................................................................................................... 91
6.2. Setup Instructions ......................................................................................................... 92

List of Figures

Figure 1-1 Ethernet Interface Cards ....................................................................................... 1


Figure 1-2 Ethernet Card Application Illustration..................................................................... 2
Figure 4-1 Ethernet Interface Card without Switch VT-100 Menu Tree.................................... 6
Figure 5-1 Ethernet Interface Card with Switch VT-100 Menu Tree ...................................... 34

List of Tables

Table 3-1 LED Indication for Ethernet Cards ......................................................................... 5


Table 4-1 Mode Setting Options.......................................................................................... 11
Table 4-2 Payload/LCAS Setting Options ............................................................................ 13
Table 4-3 Encapsulation Type Setting Options .................................................................... 14
Table 4-4 Encapsulation Parameter Setting Options ........................................................... 15
Table 4-5 GFP Parameter Setting Options .......................................................................... 16
Table 4-6 LAPS Parameter Setting Options ........................................................................ 17
Table 4-7 BCP Parameter Setting Options .......................................................................... 18
Table 4-8 Path Alarm Setting Options 1 .............................................................................. 20
Table 4-9 Path Alarm Setting Options 2 .............................................................................. 20
Table 4-10 WAN (VCG) Alarm Threshold Setting Options ..................................................... 22
Table 4-11 Linkdown Alarm Setting Options.......................................................................... 23
Table 4-12 Link Config Setting Options ................................................................................. 24
Table 4-13 Link Failure Propagation Setting Options............................................................. 26
Table 4-14 Inter-Frame Gap (IFG)Setting Options ................................................................ 27
Table 4-15 Performance Threshold Setting Options .............................................................. 29
Table 4-16 SNCP/UPSR APS Command Setting Options ..................................................... 32
Table 5-1 Mode Setting Options.......................................................................................... 38
Table 5-2 Payload/LCAS Setting Options ............................................................................ 40
Table 5-3 Encapsulation Type Setting Options .................................................................... 41
Table 5-4 Encapsulation Parameter Setting Options ........................................................... 42
Table 5-5 GFP Parameter Setting Options .......................................................................... 42
Table 5-6 LAPS Parameter Setting Options ........................................................................ 44
Table 5-7 BCP Parameter Setting Options .......................................................................... 45
Table 5-8 Path Alarm Setting Options 1 .............................................................................. 46
Table 5-9 Path Alarm Setting Options 2 .............................................................................. 47
Table 5-10 WAN (VCG) Alarm Threshold Setting Options ..................................................... 48
Table 5-11 Linkdown Alarm Setting Options.......................................................................... 49
Table 5-12 Link Config Setting Options ................................................................................. 50
Table 5-13 Link Failure Propagation Setting Options............................................................. 52
Table 5-14 Inter-Frame Gap (IFG) Setting Options................................................................ 52
Table 5-15 Performance Threshold Setting Options .............................................................. 54
Table 5-16 VLAN Tag Protocol ID Setting Options ................................................................ 57
Table 5-17 VLAN Tag Protocol ID Setting Options for Screen 1 ............................................ 58
Table 5-18 VLAN Tag Protocol ID Setting Options for Screen 2 ............................................ 58
Table 5-19 VLAN Port Association ID Setting Options for Screen 1 ....................................... 59
Table 5-20 VLAN Port Association ID Setting Options for Screen 2 ....................................... 59
Table 5-21 WAN Port Map Setting Options ........................................................................... 60
Table 5-22 LAN Port Map Setting Options ............................................................................ 61
Table 5-23 Port Trunk Setting Options .................................................................................. 62
Table 5-24 Transmission WRED Setting Options .................................................................. 78
Table 5-25 Rate Ctrl/Ingress WRED Setting Options............................................................. 79
Table 5-26 Port Bitrate Setting Options ................................................................................. 80
Table 5-27 IGMP Snooping Setting Options .......................................................................... 81
Table 5-28 IGMP Fast Leave Setting Options ....................................................................... 82
Table 5-29 IGMP Router Port Setting Options ....................................................................... 83
Table 5-30 IGMP Multicast Range Setting Options................................................................ 84
Table 5-31 IGMP Cross Vlan I Setting Options...................................................................... 85
Table 5-32 IGMP Cross Vlan II Setting Options..................................................................... 86
Table 5-33 MAC Learning Setup ........................................................................................... 87
D Bitte führen Sie das Gerät am Ende seiner Lewbensdauer den zue Verfügung
stehended Rückgabeund Sammelsystemen zu.

GB At the end of the product's useful life, please dispose of it at appropriate collection
points provided in your country

F Une fois le produit en fin devie, veuillez le déposer dans un point de recyclage
approprié.

ES Para preservar el medio ambiente, al final dela vida útil de su producto, depositelo
en los laguares destinado aello de acuerdo con la legislación vigente.

P No final de vida útil do producto, por favor coloque no ponto de recolha apropriado.

I I Onde tutelare l'ambiente, non buttate l'apparecchio trai i normali rifiuti al termine
della sua vita utile, ma portatelo presso i punti DI RACCOLTA specifici per questi
rifiuti previsti dalla normativa vigente.

NL Wij raden u aan het apparant aan het einde van zijn nuttige levensduur, niet bij hey
gewone huisafval te deponeren, maar op de dearvoor bestemde adressen.

DK Når produktet er udtjent, bor det bø rtskaffes via de sæ rlige indsamlingssteder i


landet.

N Ved slutten av produktets levetid bø r det avhendes på en kommunal miljø stasjon


eller leveres til en elektroforhandler.

S Lämna vänligen in produkten på lämplig återvinningsstation när den är förbrukad.

FIN Hävitä tuote käytöiän päättyessä viemällä se asianmukaiseen keräyspisteeseen.

PL Gdy produkt nie nadaje sie juz do dalszego uzytku, nalezy zostawic go w jednym ze
specjalnych punktów zajmujacych sie zbiórka zuzytych producktów w wybranych
miejscach na terenie kraju.

CZ Po skončení jeho životnosti odložte prosím výrobek na přislušném sbĕrném místé


zřízeném dle předpisů ve vaší zemi.

SK Po skončení jeho životnosti odovzdajte prosím zariadenie na príslušnom zbernom


mieste podía platných miestnych predpisov a noriem.

SLO Ko se izdelku izteče življenska doba, ga odnesite na ustrezno zbirno mesto oziroma
ga odvrzite v skladu z veljavnimi predpisi.

GR Στο Тέλορ тηρ λειτοςπγικήρ Ζωήρ τος πποϊόντορ παπακαλώ


Πετξτε το στα ειōικά σημεία πος Παπέσονται οτη σωπα σαρ.

PRC 當產品使用壽命結束,請在你的國家所提供的適當地點做好回收處理
e-DXC Ethernet Card

1. PRODUCT DESCRIPTION
The Ethernet Interface Card is a software configurable plug-in card for the e-DXC device.

There are two types of Ethernet cards. One is equipped with an L2 switch and one is equipped without an
L2 switch. Both cards have 8 FE Ports and 1 GbE Port. The cards are pictured below.

Figure 1-1 Ethernet Interface Cards

Alstom Page 1
e-DXC Ethernet Card

1.1. Application Illustration

SDH/SONET
Backbone

STM-1/4
(OC-3/12)

e-DXC

STM-1/4
(OC-3/12)
Backbone

10/100/1000
Ethernet

Figure 1-2 Ethernet Card Application Illustration

Alstom Page 2
e-DXC Ethernet Card

1.2. Product Specifications


The Ethernet Interface Card is a software configurable plug-in card.

Ethernet Module
Total Ports Nine (eight FE ports and one GbE Processing VCAT, GFP(G.7041), LAPS and LCAS
port) Protocol (G.7042)
Data Rate 10/100/1000 Mbps Connector RJ-45 connector
Layer2 Protocol RSTP, VLAN VCAT n x VC12, n x VC3, or n x VC4
MSTP
IGMP
QOS
Multiplexing G.707

Alstom Page 3
e-DXC Ethernet Card

2. INSTALLATION

2.1. Mechanical Installation


The Ethernet interface card will plug into any tributary slot in the e-DXC chassis. The card is hot-pluggable
(ie. it can be plugged in while the e-DXC device is powered up).

2.2. Electrical Installation


All electrical connections are on the backplane. The electrical connections are made when the card is firmly
seated into a tributary slot in the e-DXC chassis.

2.3. Configuration Setting


All configurations can be set with keyboard commands via a VT-100 monitor. Please refer to

CHAPTER 4. ETHERNET CARD (Without L2 Switch) SETUP PROCEDURE

and

CHAPTER 5. ETHERNET CARD (With L2 Switch) SETUP PROCEDURE.

Alstom Page 4
e-DXC Ethernet Card

3. OPERATION
The Ethernet card has multi-color LEDs for operation and error indications. The indication is either off, steady
on, or flickering (flashing). The following table lists each LED and its color and the meaning it represents.

Table 3-1 LED Indication for Ethernet Cards

LED Indication for Ethernet Card


LED Color Indication
ACTIVE Off Card failure
Flashing Green Working card
Flashing Amber Standby card
Flashing Red Card is unregistered
TEST Off Card self-test is okay
Flashing Red Card self-test failed.
ALM This LED is used to indicate alarm status AU-LOP, AU-AIS, TU-LOP, TU-
AIS, UNEQ, RDI, REI, BIP..., all paired alarms about SDH/SONET. It is also
used to indicate the port link status.
Red Critical alarm message or Major alarm message occurs
Amber Minor alarm message occurs
Green Informative alarm message or no alarm message occurs

Alstom Page 5
e-DXC Ethernet Card

4. ETHERNET CARD (Without L2 Switch) SETUP PROCEDURE

4.1. Menu Tree

This chapter provides detailed setup instructions for the Ethernet interface card without an L2 switch

Please note that Tributary cards must be registered with the e-DXC device or you will not be able to access
their detailed menu screens.

E-DXC Ethernet Interface Card


without Switch VT-100 Menu Tree

[DISPLAY] [SETUP]

C > WAN ( VCG) & Link Display M > Mode Setup


A > Add /Drop Channel Count S > WAN (VCG) & Link Setup
B > Customer Information Display
A > Payload/LCAS Setup
C > LAN Link Status B > Encapsulation Type Setup
D > LCAS Channel Status C > Encapsulation Parameter Setup
D> Path Alarm Setup
A > Current Alarm Status E > WAN (VCG) Alarm Threshold Setup
A > Path Alarm Status F > Linkdown Alarm Setup
B > Linkdown Alarm Status G> Link Config Setup
H > Customer Information Setup
P > Unit Performance
I > Link Fail Propagation Setup
1> 01- Hour Performance
J > Inter-Frame Gap (IFG) Setup
2> 24 - Hour Performance
3> 07 -Day Performance R > Performance Setup / Clear
G > WAN (VCG) Statistics A > Clear Performance Data
B > Performance Threshold Setup
B > SNCP/UPSR APS Status
L > File Transfer
A > Unit Download Firmware
B > Copy Firmware to Standby Unit
D > SNCP/UPSR APS Setup
A> SNCP/UPSR APS Command
B> SNCP/UPSR Revertive Setup
[LOG]
F > Log Off
O > Log On [MISC]
U > Choose a Unit Z > Unit Reset
E > Return to Main Menu W> Unit Load Default

Figure 4-1 Ethernet Interface Card without Switch VT-100 Menu Tree

Alstom Page 6
e-DXC Ethernet Card

4.2. Initial Setup and Card Registration


Prior to setting up an Ethernet Interface Card, you must first set up the main e-DXC device. Full instructions
for doing so are found in the e-DXC User’s Manual. After that setup is complete go to the main Controller
Menu for the e-DXC device. A sample screen is shown below.

You must register your Ethernet cards with the e-DXC device.

Press N to register the unit (ie. register your card).

e-DXC === Controller Menu === 09:53:10 02/06/2009

Serial Number : 000011 Device Name : e-DXC


Hardware Version: B Start Time : 09:34:03 02/06/2009
Software Version: V1.02.01 01/21/2009 Connect Port : SUPV_PORT

[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Display H -> SDH/SONET Setup
J -> PDH Display K -> PDH Setup
P -> Map Display G -> Map Setup
Q -> Alarm Queue M -> Alarm Setup
I -> System Information L -> File Transfer
T -> System Log V -> Store/Retrieve Backup Config
N -> Unit Registration

[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default

>>SPACE bar to refresh or enter a command ===>

The Unit Registration screen will appear. Select the command “Card Registration” and press the Enter key.

e-DXC === Unit Registration === 10:16:37 02/06/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Slot REG. Model/Mode Card Model Software Version Remark


==== =============== ================ =================== =================
#1
#2
#3
#4
(PRTD = Protected, NP = No Protection)
==== =============== ================ =================== =================
#11
#12
#13
#14
#15 Quad E1 Quad E1 V3.01.03 06/27/2008
#16 Quad E1 V3.01.06 03/28/2008

Command : Card Registration

<< Press ESC key to return to previous menu >>

Use the Tab key to scroll in the Tributary slot that your Ethernet card is plugged into. Press the Enter key.

Command : Card Registration


Unit : Trib-3

Alstom Page 7
e-DXC Ethernet Card

The model of card will appear. “ENET” represents Ethernet card without switch, “ENETSW” represents
Ethernet card with switch. Move the cursor to the Registered Model field and select the protection type.

In the sample screen below, we choose ENET-NP:

Command : Card Registration


Unit : Trib-3
Registered Model : ENET-NP

Press the Enter key. A registration prompt will appear as the registration takes place.

Registration......SUCCESS!

After registration, the card information will show on the screen:

e-DXC === Unit Registration === 10:16:37 02/06/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Slot REG. Model/Mode Card Model Software Version Remark


==== =============== ================ =================== =================
#1
#2
#3 ENET-NP FE V1.02.02 07/03/2008
#4
(PRTD = Protected, NP = No Protection)
==== =============== ================ =================== =================
#11
#12
#13
#14
#15 Quad E1 Quad E1 V3.01.03 06/27/2008
#16 Quad E1 V3.01.06 03/28/2008

Command : Card Registration

<< Press ESC key to return to previous menu >>

If you have other cards to register do it now. Each plug-in interface card must be registered separately.

Alstom Page 8
e-DXC Ethernet Card

Change Protection Mode:


To change the protection mode, you do not need to de-register the card. Simply use the command “Change
Protection Mode”. You can change the card’s protection mode from NP (without protection) to PRTD (with
protection), or vise-versa.

Card De-registration:
To de-register a card, please activate the command “Card Un-registration”. The setup procedure is similar to
that of “Card registration”.

e-DXC === Unit Registration === 10:16:37 02/06/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Slot REG. Model/Mode Card Model Software Version Remark


==== =============== ================ =================== =================
#1 B155/622 V1.01.01 10/19/2007
#2 E1/T1(32Port) V1.01.02 11/16/2007
#3 ENET-NP FE V1.02.02 07/03/2008
#4
(PRTD = Protected, NP = No Protection)
==== =============== ================ =================== =================
#11
#12
#13
#14
#15 Quad E1 Quad E1 V3.01.03 06/27/2008
#16 Quad E1 V3.01.06 03/28/2008

Command : Card Un-registration

<< Press ESC key to return to previous menu >>

Alstom Page 9
e-DXC Ethernet Card

4.3. Choosing a Trib Unit


Press U from the e-DXC Controller Menu to select the Tributary slot that the Ethernet interface card is
plugged into.

e-DXC === Controller Menu === 09:53:10 02/06/2009

Serial Number : 000011 Device Name : e-DXC


Hardware Version: B Start Time : 09:34:03 02/06/2009
Software Version: V1.02.01 01/21/2009 Connect Port : SUPV_PORT

[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Display H -> SDH/SONET Setup
J -> PDH Display K -> PDH Setup
P -> Map Display G -> Map Setup
Q -> Alarm Queue M -> Alarm Setup
I -> System Information L -> File Transfer
T -> System Log V -> Store/Retrieve Backup Config
N -> Unit Registration

[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default

>>SPACE bar to refresh or enter a command ===>

A prompt will appear. Use the Tab key to scroll in the card’s Tributary slot number. Press the Enter key.

==>> Press Tab key to select the unit: 3

The unit menu will show as below:

Unit 1 ENET === Unit Menu === 18:06:13 09/02/2011

HW Version : C Card State : Initialization Completed


SW Version : V2.07.02 03/08/2011

[DISPLAY] [SETUP]
C -> WAN(VCG) & Link Display M -> Mode Setup
A -> Current Alarm Status S -> WAN(VCG) & Link Setup
P -> Unit Performance R -> Performance Setup/Clear
G -> WAN(VCG) Statistics L -> File Transfer
B -> SNCP/UPSR Status D -> SNCP/UPSR APS Setup

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

Alstom Page 10
e-DXC Ethernet Card

4.4. Mode Setup

The Unit Menu path for Mode Setup is as follows:

M> Mode Setup

The Mode Setup screen will appear. Use the Tab key to scroll in your setting. Then press the Enter key.

Table 4-1 Mode Setting Options

Field Setting Default Setting


Mode Selection e-line (8FE) e-line (8FE)
e-line(1GE)

Unit 1 ENET === Mode Setup === 16:48:35 01/04/2008


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

Mode Selection : e-line(8FE)

A prompt will ask if you wish to change to this new configuration. Press Y for yes.

>> Change configuration (Y/N)? (Note:to save,please use V-command)

A prompt will advise you that the change was successful.

SUCCESS

You must save this change. To do so, press E to return to the e-DXC device Controller Menu as shown
below. Then press V from the main menu.

e-DXC === Controller Menu === 09:53:10 02/06/2009

Serial Number : 000011 Device Name : e-DXC


Hardware Version: B Start Time : 09:34:03 02/06/2009
Software Version: V1.02.01 01/21/2009 Connect Port : SUPV_PORT

[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Display H -> SDH/SONET Setup
J -> PDH Display K -> PDH Setup
P -> Map Display G -> Map Setup
Q -> Alarm Queue M -> Alarm Setup
I -> System Information L -> File Transfer
T -> System Log V -> Store/Retrieve Backup Config
N -> Unit Registration

[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default

>>SPACE bar to refresh or enter a command ===>

Alstom Page 11
e-DXC Ethernet Card

The Store/Retrieve Configuration screen will appear. Use the arrow keys to move the flashing cursor to
STORE. Press the Enter key. Press Y for yes.

e-DXC ===Store/Retrieve Configuration=== 17:19:20 02/20/2009

>> Select ? *STORE RETRIEVE


>> Store Current Configuration ? [Y/N]

You will be asked to key in your password. The default password is eDXC in upper case letters.
Press the Enter key.

e-DXC ===Store/Retrieve Configuration=== 17:19:20 02/20/2009

>> Select ? *STORE RETRIEVE


==>> Enter password :

The following message will be displayed as the storage process takes place.

>> Select ? *STORE RETRIEVE


===> Saving.......

Press the Esc key to return to the Controller Menu.

Alstom Page 12
e-DXC Ethernet Card

4.5. WAN (VCG) & Link Setup

The Unit Menu path for WAN (VCG) & Link Setup is as follows:

S > WAN (VCG) & Link Setup

Then press one of the following:

A > Payload/LCAS Setup


B > Encapsulation Type Setup
C > Encapsulation Parameter Setup
D > Path Alarm Setup
E > WAN (VCG) Alarm Threshold Setup
F > Linkdown Alarm Setup
G > Link Config Setup
H > Customer Information Setup
I > Link Fail Propagation Setup
J -> Inter-Frame Gap(IFG) Setup

Screen by screen setup examples are shown below:

4.5.1. Payload/LCAS Setup

The Unit Menu path for Payload/LCAS Setup is as follows:


S > WAN (VCG) & Link Setup
A > Payload/LCAS Setup

The Payload/LCAS Setup screen will appear. Use the arrow keys to move the cursor to the various fields.
Then use the Tab key to scroll in your settings. Press the Enter key.

Table 4-2 Payload/LCAS Setting Options

VCG Field SDH Payload Default LCAS LCAS


MODE Settings Payload Mode Mode
Setting Default
Setting
WAN1 (GE) Mode 1 TU12, TU12 LCAS, LCAS
WAN2 to 9 (FE) TU3, Non LCAS
AU4/C4,
AU3/C3
Mode 2 TU11, TU11
AU4/C4,
AU3/C3

Alstom Page 13
e-DXC Ethernet Card

Unit 3 EN ETS W == = P ayl oad /LC AS Set up = == 18: 07: 43 11/ 24/ 200 9
ARRO W K EYS : CUR SOR MO VE , E NTE R K EY : I TEM SEL ECT

SD H M ode : M ode 1

[WA N] [p ayl oad ] [lc as mod e]


WAN 1(G E) : TU 12 LCA S

WAN 2(F E) : TU 12 LCA S


WAN 3(F E) : TU 12 LCA S
WAN 4(F E) : TU 12 LCA S
WAN 5(F E ) : TU 12 LCA S
WAN 6(F E) : TU 12 LCA S
WAN 7(F E) : TU 12 LCA S
WAN 8(F E) : TU 12 LCA S
WAN 9(F E) : TU 12 LCA S

Note : M ode 1 sup por ts AU4 /C4 , A U3/ C3, TU 3, TU12


M ode 2 sup por ts AU4 /C4 , A U3/ C3, TU 11

<< P re s s E SC key to re tur n t o p rev iou s m enu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

4.5.2. Encapsulation Type Setup

The Unit Menu path for Encapsulation Type Setup is as follows:

S > WAN (VCG) & Link Setup


B > Encapsulation Type Setup

The Encapsulation Type Setup screen will appear. Use the arrow keys to move the cursor to the various
fields. Then use the Tab key to scroll in your settings. Press Enter.

Table 4-3 Encapsulation Type Setting Options

Field Encapsulation Type Settings Default


Setting
WAN1 (GE) GFP GFP
WAN2 to 9(FE) LAPS
BCP

Alstom Page 14
e-DXC Ethernet Card

Unit 3 ENET === Encapsulation Type Setup === 16:33:20 02/10/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

Encapsulation Type

WAN1(GE) : GFP

WAN2(FE) : GFP
WAN3(FE) : GFP
WAN4(FE) : GFP
WAN5(FE) : GFP
WAN6(FE) : GFP
WAN7(FE) : GFP
WAN8(FE) : GFP
WAN9(FE) : GFP

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

4.5.3. Encapsulation Parameter Setup

The Unit Menu path for Encapsulation Parameter Setup is as follows:

S > WAN (VCG) & Link Setup


C > Encapsulation Parameter Setup

The Encapsulation Parameter Setup screen will appear. Use the arrow keys to move the cursor to the (VCG)
WAN# field. Then key in the WAN# setting. Press the Enter key.

Table 4-4 Encapsulation Parameter Setting Options

Field Setting Range Default Setting


(VCG) WAN# 2 to 9 2

Unit 3 ENET === Encapsulation Par Setup === 17:20:34 02/20/2009


ARROW KEYS: CURSOR MOVE, Please Input: 2 to 9, BACKSPACE to edit
(VCG) WAN# : 2

<< Press ESC key to return to previous menu >>

If your encapsulation type is GFP, the GFP Parameter Setup screen will appear. Use the arrow keys to
move the cursor to the various fields. Some settings must be keyed in. Some must be scrolled in using the
Tab key. Press the Enter key.

Alstom Page 15
e-DXC Ethernet Card

Table 4-5 GFP Parameter Setting Options

Field Settings Default Setting


Rx PTI 0 to 7 0
Rx EXI 0 to 0xF 0
Rx UPI 0 to 0xFF 01
DELTA 1 to 4 1
Rx Descramble Disable Enable
Rx Payload FCS Check Enable Disable
Rx PTI Check Disable
Rx UPI Check Disable
Tx PTI 0 to 7 0
Tx EXI 0 to 0xF 0
Tx UPI 0 to 0xFF 01
Tx PFI 0 to 1 0
Tx Scramble Disable Enable
Tx Payload FCS Insert Enable Disable
Tx/Rx Payload FCS CRC-32 CRC-32
Mode CRC-16

Unit 3 ENET === GFP Parameter Setup === 16:39:29 02/10/2009


ARROW KEYS: CURSOR MOVE, Please Input: 0 to 7, BACKSPACE to edit
(VCG) WAN# : 2

Rx PTI : 0 Tx PTI : 0
Rx EXI : 0 Tx EXI : 0
Rx UPI : 1 Tx UPI : 01
DELTA : 1 Tx PFI : 0

Rx Descramble : Enable Tx Scramble : Enable


Rx Payload FCS Check : Disable Tx Payload FCS Insert : Disable
Rx PTI Check : Disable Tx/Rx Payload FCS Mode : CRC-32
Rx UPI Check : Disable

<< Press ESC key to return to previous menu >>

If your encapsulation type is LAPS, the LAPS Parameter Setup screen will appear. Use the arrow keys to
move the cursor to the various fields. Some settings must be keyed in. Some must be scrolled in using the
Tab key. Press the Enter key.

Alstom Page 16
e-DXC Ethernet Card

Table 4-6 LAPS Parameter Setting Options

Field Settings Default Setting


Rx Address 0 to 0xFF 4
Rx Control 0 to 0xFF 03
Rx SAPI MSB 0 to 0xFF FE
Rx SAPI LSB 0 to 0xFF 01
Rx Descramble Disable/Enable Enable
Rx Payload FCS Check Disable/Enable Enable
Rx Address Check Disable/Enable Disable
Rx Control Check Disable/Enable Disable
Rx SAPI Check Disable/Enable Disable
Tx Address 0 to 0xFF 04
Tx Control 0 to 0xFF 03
Tx SAPI MSB 0 to 0xFF FE
Tx SAPI LSB 0 to 0xFF 01
Tx Scramble Disable/Enable Enable
Tx Payload FCS Insert Disable/Enable Enable
Tx/Rx Payload FCS CRC-32 CRC-32
Mode CRC-16

Unit 3 ENET === LAPS Parameter Setup === 17:18:45 02/10/2009


ARROW KEYS: CURSOR MOVE, Please Input: 0 to 0xFF, BACKSPACE to edit
(VCG) WAN# : 2

Rx Address : 4_ Tx Address : 04
Rx Control : 03 Tx Control : 03
Rx SAPI MSB : FE Tx SAPI MSB : FE
Rx SAPI LSB : 01 Tx SAPI LSB : 01

Rx Descramble : Enable Tx Scramble : Enable


Rx Payload FCS Check : Enable Tx Payload FCS Insert : Enable
Rx Address Check : Disable Tx/Rx Payload FCS Mode : CRC-32
Rx Control Check : Disable
Rx SAPI Check : Disable

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 17
e-DXC Ethernet Card

If your encapsulation type is BCP, the BCP Parameter Setup screen will appear. Use the arrow keys to
move the cursor to the various fields. Some settings must be keyed in. Some must be scrolled in using the
Tab key. Press the Enter key.

Table 4-7 BCP Parameter Setting Options

Field Settings Default Setting


Rx Address 0 to 0xFF FF
Rx Control 0 to 0xFF 03
Rx Protocol MSB 0 to 0xFF 00
Rx Protocol LSB 0 to 0xFF 31
Rx Descramble Disable/Enable Enable
Rx Payload FCS Check Disable/Enable Enable
Rx Address Check Disable/Enable Disable
Rx Control Check Disable/Enable Disable
Rx Protocol Check Disable/Enable Disable
Rx Bit F 0/1 0
Rx Bit Z 0/1 1
Rx Pads 0 to 0xF 0
Rx MAC Type 0 to 0xFF 01
Rx BCP Flags Check Disable/Enable Disable
Rx BCP MAC Type Check Disable/Enable Disable
Tx Address 0 to 0xFF FF
Tx Control 0 to 0xFF 03
Tx Protocol MSB 0 to 0xFF 00
Tx Protocol LSB 0 to 0xFF 31
Tx Scramble Disable/Enable Enable
Tx Payload FCS Insert Disable/Enable Enable
Tx Payload FCS Mode CRC-32, CRC-16 CRC-32
Tx Bit F 0/1 0
Tx Bit Z 0/1 1
Tx Pads 0 to 0xF 0
Tx MAC Type 0 to 0xFF 01

Alstom Page 18
e-DXC Ethernet Card

Unit 1 ENETSW === BCP Parameter Setup === 14:47:18 11/26/2009


ARROW KEYS: CURSOR MOVE, Please Input: 0 to 0xFF, BACKSPACE to edit
(VCG) WAN# : 2

Rx Address : FF Tx Address : FF
Rx Control : 03 Tx Control : 03
Rx Protocol MSB : 00 Tx Protocol MSB : 00
Rx Protocol LSB : 31 Tx Protocol LSB : 31

Rx Descramble : Enable Tx Scramble : Enable


Rx Payload FCS Check : Enable Tx Payload FCS Insert : Enable
Rx Address Check : Disable Tx/Rx Payload FCS Mode : CRC-32
Rx Control Check : Disable
Rx Protocol Check : Disable

Rx Bit F : 0 Tx Bit F : 0
Rx Bit Z : 1 Tx Bit Z : 1
Rx Pads : 0 Tx Pads : 0
Rx MAC Type : 01 Tx MAC Type : 01

Rx BCP Flags Check : Disable


Rx BCP MAC Type Check : Disable
<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V.

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 19
e-DXC Ethernet Card

4.5.4. Path Alarm Setup

The Unit Menu path for Path Alarm Setup is as follows:

S > WAN (VCG) & Link Setup


D > Path Alarm Setup

The Path Alarm Setup screen will appear. Use the arrow keys to move the cursor to the various fields. Then
use the Tab key to scroll in your settings. Press the Enter key.

Table 4-8 Path Alarm Setting Options 1

Field Settings Default Setting


(VCG) WAN# 2 to 9 2
path low-order low-order
hi-order

Unit 3 ENET === Path Alarm Setup === 18:18:09 02/10/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

(VCG) WAN# 2 path : low-order

<< Press ESC key to return to previous menu >>

An advanced Path Alarm Setup screen will appear. Use the arrow keys to move the cursor to the various
fields. Then use the Tab key to scroll in your settings. Press the Enter key.

Table 4-9 Path Alarm Setting Options 2

Low-order Alarm Alarm Relay Relay Severity Severity


Path Type Settings Default Settings Default Settings Default
TU-LOP ENABLED ENABLED ENABLED DISABLED INFO MAJR
TU-AIS DISABLED ENABLED DISABLED MINR MAJR
LP-UNEQ DISABLED MAJR INFO
LP-RDI-P DISABLED CRIT INFO
LP-RDI-S DISABLED INFO
LP-RDI-C DISABLED INFO
LP-REI DISABLED INFO
LP-BIP DISABLED INFO

Hi-order Alarm Alarm Relay Relay Severity Severity


Path Type Settings Default Settings Default Settings Default
AU-LOP ENABLED ENABLED ENABLED DISABLED INFO MAJR
AU-AIS DISABLED ENABLED DISABLED MINR MAJR
HP-UNEQ DISABLED MAJR INFO
HP-RDI-P DISABLED CRIT INFO
HP-RDI-S DISABLED INFO
HP-RDI-C DISABLED INFO
HP-B3-REI DISABLED INFO
HP-B3-BIP DISABLED INFO

Unit 3 ENET === Path Alarm Setup === 18:18:09 02/10/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

(VCG) WAN# 2 path : low-order

Alstom Page 20
e-DXC Ethernet Card

type alarm relay severity


TU-LOP ENABLED DISABLED MAJR
TU-AIS ENABLED DISABLED MAJR
LP-UNEQ DISABLED DISABLED INFO
LP-RDI-P DISABLED DISABLED INFO
LP-RDI-S DISABLED DISABLED INFO
LP-RDI-C DISABLED DISABLED INFO
LP-REI DISABLED DISABLED INFO
LP-BIP DISABLED DISABLED INFO

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 21
e-DXC Ethernet Card

4.5.5. WAN (VCG) Alarm Threshold Setup

The Unit Menu path for WAN (VCG) Alarm Threshold Setup is as follows:

S > WAN (VCG) & Link Setup


E > WAN (VCG) Alarm Threshold Setup

The WAN (VCG) Alarm Threshold Setup screen will appear. Use the arrow keys to move the cursor to the
various fields. Then use the Tab key to scroll in your settings. Threshold settings must be keyed in. Press
the Enter key.

Table 4-10 WAN (VCG) Alarm Threshold Setting Options

Field En/Dis En/Dis Severity Severity Threshold Threshold


Settings Default Settings Default Settings Default
Errored FCS Count EN DIS INFO MINR 1 to 99999 00100
FIFO Overflow DIS MINR
Frame Count MAJR
Dropped Frame Count CRIT

Unit 3 ENET === WAN(VCG) Alarm Threshold Setup === 18:23:41 02/10/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

En/Dis severity Threshold


Errored FCS count DIS MINR 00100
FIFO overflow frame count DIS MINR 00100
dropped frame count DIS MINR 00100

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 22
e-DXC Ethernet Card

4.5.6. Linkdown Alarm Setup

The Unit Menu path for Linkdown Alarm Setup is as follows:

S > WAN (VCG) & Link Setup


F-> Linkdown Alarm Setup

The Linkdown Alarm Setup screen will appear. Use the arrow keys to move the cursor to the various fields.
Then use the Tab key to scroll in your settings. Press the Enter key.

Table 4-11 Linkdown Alarm Setting Options

Port Alarm Alarm Relay Relay Severity Severity


Settings Default Settings Default Settings Default
LAN1 to 9 ENABLED ENABLED ENABLED DISABLED INFO MINR
DISABLED DISABLED MINR
MAJR
CRIT

Unit 3 ENET === Linkdown Alarm Setup === 17:24:23 02/20/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

port alarm relay severity


-----------------------------------------
LAN1 ENABLED DISABLED MINR
LAN2 ENABLED DISABLED MINR
LAN3 ENABLED DISABLED MINR
LAN4 ENABLED DISABLED MINR
LAN5 ENABLED DISABLED MINR
LAN6 ENABLED DISABLED MINR
LAN7 ENABLED DISABLED MINR
LAN8 ENABLED DISABLED MINR
LAN9 ENABLED DISABLED MINR

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 23
e-DXC Ethernet Card

4.5.7. Link Config Setup

The Unit Menu path for Link Config Setup is as follows:

S > WAN (VCG) & Link Setup


G > Link Config Setup

The Link Config Setup screen will appear. Use the arrow keys to move the cursor to the various fields. Then
use the Tab key to scroll in your settings. Press the Enter key.

Table 4-12 Link Config Setting Options

Port Link Config Settings Default Setting


LAN1 Auto negotiation Auto negotiation
100M full-duplex
10M full-duplex
100M half-duplex
10M half-duplex
1000M full-duplex
LAN2-9 Auto negotiation Auto negotiation
100M full-duplex
10M full-duplex
100M half-duplex
10M half-duplex

Unit 3 ENET === Link Config Setup === 17:24:55 02/20/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

port link config


----------------------------
LAN1 Auto negotiation
LAN2 Auto negotiation
LAN3 Auto negotiation
LAN4 Auto negotiation
LAN5 Auto negotiation
LAN6 Auto negotiation
LAN7 Auto negotiation
LAN8 Auto negotiation
LAN9 Auto negotiation

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 24
e-DXC Ethernet Card

4.5.8. Customer Information Setup

The Unit Menu path for Customer Information Setup is as follows:

S > WAN (VCG) & Link Setup


H > Customer Information Setup

The Customer Information Setup screen will appear. Use the arrow keys to move the cursor to the various
fields. Then key in the customer name for each LAN. Press the Enter key.

Unit 3 ENET === Customer Information Setup === 17:32:51 02/20/2009


ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort

Port# Customer Information


LAN1 name of link#1______
LAN2 name of link#2
LAN3 name of link#3
LAN4 name of link#4
LAN5 name of link#5
LAN6 name of link#6
LAN7 name of link#7
LAN8 name of link#8
LAN9 name of link#9

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 25
e-DXC Ethernet Card

4.5.9. Link Failure Propagation

Note: Local LAN Port failure is reflected upstream at the WAN Port. The Ethernet port of each device is
monitored. If a link failure is detected at either device a signal will automatically be sent to the other device
to shut down the corresponding Ethernet port. Thus, the shut down of an Ethernet port is propagated.

Similarly, if WAN (VCG) port failure occurs, link failure propagation will shut down the corresponding LAN
ports. Link Failure Propagation is for E-line mode only.

The Unit Menu path for Link Failure Propagation is as follows:

S >WAN(VCG) & Link Setup


I > Link Failure Propagation

Table 4-13 Link Failure Propagation Setting Options


Field Settings Default Setting Notes
WAN (VCG) Lost Propagation ENABLED, DISABLED
Remote Link Down Propagation DISABLED DISABLED Remote Link Down
Remote Link Down Guard Time 1 to 5 Sec. 1 sec. Propagation is only
supported in GFP mode.

Unit 3 ENET === Link Fail Propagation Setup === 17:34:30 02/20/2009
ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

WAN(VCG) Lost Propagation : DISABLED


Remote Link Down Propagation : DISABLED
Remote Link Down Guard Time : 1 second

Note: "Remote Link Down Propagation" is only supported in GFP mode.


<< Press ESC key to return to previous menu >>

Alstom Page 26
e-DXC Ethernet Card

4.5.10. Inter-Frame Gap (IFG) Setup

The Unit Menu path for Inter-Frame Gap Setup is as follows:

S >WAN(VCG) & Link Setup


J > Inter-Frame Gap (IFG) Setup

The Inter-Frame Gap (IFG) Setup screen will appear. Input your IFG settings and press the Enter key.

Table 4-14 Inter-Frame Gap (IFG) Setting Options

Port Fields IFG Settings Default Setting


LAN1 to LAN 9 80, 88, 96 96

Unit 1 ENET === Inter-Frame Gap(IFG) Setup === 04:21:52 09/04/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

Port IFG (Bit Times)


------ ---------------
LAN1 96
LAN2 96
LAN3 96
LAN4 96
LAN5 96
LAN6 96
LAN7 96
LAN8 96
LAN9 96

<< Press ESC key to return to previous menu >>

Alstom Page 27
e-DXC Ethernet Card

4.6. Performance Setup/Clear

The Unit Menu path for Performance Setup/Clear is as follows:

R > Performance Setup/Clear

Then press one of the following:

A > Clear Performance Data


B > Performance Threshold Setup

Screen by screen setup examples are shown below:

4.6.1. Clear Performance Data


The Unit Menu path for Clear Performance Data is as follows:

R > Performance Setup/Clear


A > Clear Performance Data

Unit 3 ENET === Performance Setup/Clear === 17:35:09 02/20/2009

A -> Clear Performance Data


B -> Performance Threshold Setup

>> Clear performance data - are you sure [Y/N] ?

Alstom Page 28
e-DXC Ethernet Card

4.6.2. Performance Threshold Setup

The Unit Menu path for Performance Threshold Setup is as follows:

R > Performance Setup/Clear


B > Performance Threshold Setup

The Performance Threshold Cross Alarm Setup screen will appear. Use the arrow keys to move the cursor
to the various fields. Then use the Tab key to scroll in your settings. Press the Enter key.

Table 4-15 Performance Threshold Setting Options

Monitor Point EN/DIS EN/DIS Severity Severity Threshold Threshold


Settings Default Settings Default Settings Default
HP-BIP(B3) EN DIS INFO INFO 1 to 99999 02400
HP-REI DIS MINR 02400
LP-BIP(V5) MAJR 00600
LP-REI(V5 CRIT 00600
LP-BIP(B3) 02400
LP-REI(B3) 19200

Unit 3 ENETSW === Perf. Threshold Cross Alarm Setup === 17:35:48 02/20/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Monitor Point En/Dis severity Threshold


HP-BIP(B3) DIS INFO 02400
HP-REI DIS INFO 02400
LP-BIP(V5) DIS INFO 00600
LP-REI(V5) DIS INFO 00600
LP-BIP(B3) DIS INFO 02400
LP-REI(B3) DIS INFO 19200

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 29
e-DXC Ethernet Card

4.7. File Transfer

The Unit Menu path for File Transfer is as follows:

L > File Transfer

Then press one of the following:

A > Unit Download Firmware


B > Copy Firmware to Standby Unit

Screen by screen setup examples are shown below:

4.7.1. Unit Download Firmware

The Unit Menu path for Unit Download Firmware is as follows:

L > File Transfer


A > Unit Download Firmware

The Unit Download Firmware setup screen will appear. Use the arrow keys to move the cursor to the
various fields. Key in the TFTP Server IP address and a Firmware File Name. Press the Enter key.

Unit 1 ENET === Unit Download Firmware === 14:46:05 11/03/2007


ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort

Firmware 1 Version : V1.01.01 10/19/2007


Firmware 2 Version : V1.01.01 10/19/2007
Current Firmware Bank: 1
Next Boot Firmware : 1
TFTP Server IP : 10.3.11.1
Firmware File Name : O94RENET.RUN____________________________________________

<< Press ESC key to abort, ENTER key to Upload/Download Firmware >>

A prompt will ask if you really want to download. Press Y for yes.

Really want to Download ?

A message will be displayed as the download is in progress and a new message will appear once the
download is complete.
Unit 1 ENET === Unit Download Firmware === 14:48:39 11/03/2007
ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort

Firmware 1 Version : V1.01.01 10/19/2007


Firmware 2 Version : V1.01.01 10/19/2007
Current Firmware Bank: 1
Next Boot Firmware : 1
TFTP Server IP : 010.003.011.001
Firmware File Name : O94RENET.RUN

14:48:45 11/03/07 Downloading firmware ........619148 bytes received.


14:48:55 11/03/07 Send firmware file to trib-2 ........Download Complete.

<< Press ESC key to abort, ENTER key to Upload/Download Firmware >>

Alstom Page 30
e-DXC Ethernet Card

4.8. SNCP/UPSR APS Setup

The Unit Menu path for SNCP/UPSR APS Setup is as follows:

D > SNCP/UPSR APS Setup

The following SNCP/UPSR APS Setup screen will appear. Press A or B.

Unit 1 ENET === SNCP/UPSR APS Setup === 18:06:26 09/02/2011

A -> SNCP/UPSR APS Command


B -> SNCP/UPSR Revertive Setup

<< Press ESC key to return to Main Menu or enter a command >>

4.8.1. SNCP/UPSR APS Command

The Unit Menu path for SNCP/UPSR APS Command is as follows:

D > SNCP/UPSR APS Setup


A > SNCP/UPSR APS Command

The SNCP/UPSR APS Command screen will appear. Use the arrow keys to move the cursor. Key in the
Port number. Scroll in the Channel #. Press the Enter key.

Unit 1 ENET === SNCP/UPSR APS Setup === 18:06:26 09/02/2011


ARROW KEYS: CURSOR MOVE, Please Input: 2 to 9, BACKSPACE to edit
Select path ==>

Port : 2_
Channel : 01

<< Press ESC key to return to previous menu >>

An expanded screen will appear. Scroll in your Command setting. (See SNCP/UPSR APS Command
Setting Options in table above.) Press the Enter key. A prompt will ask if you are sure. Press Y for yes.

Unit 1 ENET === SNCP/UPSR APS Setup === 18:06:26 09/02/2011


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Port : 2
Channel : 01

Command : Clear

Note :
FS = Force Switch
MS = Manual Switch
PRI = Primary
SEC = Secondary
<< Press ESC key to return to previous menu >>

Alstom Page 31
e-DXC Ethernet Card

4.8.2. SNCP/UPSR Revertive Setup

The Unit Menu path for SNCP/UPSR Revertive Setup is as follows:

D > SNCP/UPSR APS Setup


B > SNCP/UPSR Revertive Setup

The SNCP/UPSR Revertive Setup screen will appear. Use the arrow keys to move the cursor. Key in the
Port number. Scroll in the Channel #. Press the Enter key.

Unit 1 ENET === SNCP/UPSR Revertive Setup === 18:06:50 09/02/2011


ARROW KEYS: CURSOR MOVE, Please Input: 2 to 9, BACKSPACE to edit
Select path ==>

Port : 2_
Channel : 01

<< Press ESC key to return to previous menu >>

An expanded screen will appear. Scroll in your Command setting. (See SNCP/UPSR APS Command
Setting Options in table above.) Press the Enter key. A prompt will ask if you are sure. Press Y for yes.

Unit 1 ENET === SNCP/UPSR Revertive Setup === 18:06:50 09/02/2011


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Port : 2
Channel : 01
Revertive: Non-Revertive

Note :
FS = Force Switch
MS = Manual Switch
PRI = Primary
SEC = Secondary
<< Press ESC key to return to previous menu >>

Table 4-16 SNCP/UPSR APS Command Setting Options

Fields Settings Default Setting Notes


Port 1 to 9 2 1GE -> 1, 8FE -> 2 to 9
Channel 1 to 63 1
Command Clear, Clear FS = Force Switch
FS, MS, MS = Manual Switch
PRI, SEC PRI = Primary
SEC = Secondary

Alstom Page 32
e-DXC Ethernet Card

4.9. Reset Unit

The Unit Menu path for Reset Unit is as follows:

Z > Reset Unit

Use the arrow keys to move the flashing cursor to either Working, Standby or Both. Press the Enter key.

Unit 1 ENET === Unit Reset === 14:21:51 01/07/2008

>>Unit? *Working Standby Both

The following prompt will appear. Press Y for Yes

Reset - are you sure ? [Y/N]

4.10. Unit Load Default

The Unit Menu path for Unit Load Default is as follows:

W > Unit Load Default

A prompt will ask if you want to load the default configuration. Press Y for Yes.

Load default - are you sure (Y/N)?

Key in your password. Press the Enter key.

==>> Enter password :

Alstom Page 33
e-DXC Ethernet Card

5. ETHERNET CARD (With L2 Switch) SETUP PROCEDURE


5.1. Menu Tree

This chapter provides detailed setup instructions for the Ethernet interface card with an L2 switch

Please note that Tributary cards must be registered with the e-DXC device or you will not be able to access
their detailed menu screens.

VT-100Menu Tree

[DISPLAY] [SETUP]
C > WAN (VCG) & Link Display M > Mode Setup
A > Add/Drop Channel Count S > WAN( VCG) & Link Setup
B > Customer Information Display A > Payload/LCAS Setup
C > LAN Link Status B > Encapsulation Type Setup
D > LCAS Channel Setting C > Encapsulation Parameter Setup
D > Path Alarm Setup
A > Current Alarm Status
E > WAN (VCG) Alarm Threshold Setup
A > Path Alarm Status F > Linkdown Alarm Setup
B > Linkdown Alarm Status G > Link Config Setup
H > Customer Information Setup
I > Link Fail PropagationSetup
P > Unit Performance J > Inter-Frame Gap ( IFG) Setup A > VLAN Tag Protocol ID Setup
B > VLAN Port Configuration Setup
1 > 01-Hour Performance C > VLAN Port Association Setup
R> Performance Setup / Clear
2 > 24-Hour Performance A > Clear Performance Data
A > WAN Port Map Setup
3 > 07-Day Performance B > Performance Threshold Setup B > LAN Port Map Setup

G > WAN (VCG) Statistics


L> File Transfer A > MSTP Region/CIST Setup
B > Spanning Tree Port Setup
I > Switch Status A> Unit Download Firmware C > MSTP Instance/VLAN Setup
D > MSTP Instance/Priority Setup
A > Port Statistics B> Copy Firmware to Standby Unit E > MSTP/RSTP Port Setup
F > RSTP Bridge Setup
B > VLAN ID Info H> Switch Setup
C > VLAN Port Association A > VLAN Setup
D > MSTP Region/CIST Display B > Port Map Setup A > Priority Mode Setup
B > Fixed Priority Setup
E > MSTP Bridge ID Display C > Port Trunk Setup C >VLAN Tag Priority Setup
F > MSTP Instance/VLAN Mapping D > MSTP/RSTP Setup D > TOS Field Priority Setup

G > MSTP/RSTP Port Display E > Flow Control Setup E > Distrusted Port Setup

H > RSTP Bridge Display F > QoS Setup A > Class of Service Setup A > TCP / UDP Well Known Port Setup
J > IP Multicast Display B > TCP/UDP Port Access Control B > TCP / UDP User Define Port Setup
C > Transmission Scheduling C > TCP /UDP Port Range Setup
D > Transmission WRED Setup
B > SNCP/UPSR APS Status E > Rate Control Setup
A > Scheduling Algorithm
B > WFQ Weight Setup
G > IGMP Setup A > IGMP Snooping
B > IGMP Fast Leave A > Rate Ctrl/ Ingress WRED Setup
C > IGMP Router Port B > Port Bitrate Setup
D > IGMP IP Multicast Range
E > IGMP Cross VLAN I
F > IGMP Cross VLAN II

H > MAC Learning Setup

D > SNCP/UPSRAPS Setup


A > SNCP/UPSR APS Command
[ LOG] B > SNCP/UPSR Revertive Setup
F > Log Off
[MISC]
O > Log On
Z > Reset Unit
U > Choose a Unit
E > Return to Main Menu W> Unit Load Default

Figure 5-1 Ethernet Interface Card with Switch VT-100 Menu Tree

Alstom Page 34
e-DXC Ethernet Card

5.2. Initial Setup and Card Registration


Prior to setting up an Ethernet Interface Card you must first set up the main e-DXC device. Full instructions
for doing so are found in the e-DXC User’s Manual. After that setup is complete go to the main Controller
Menu for the e-DXC device. A sample screen is shown below.

You must register your Ethernet cards with the e-DXC device.

Press N to register the unit (ie. register your card).

e-DXC === Controller Menu === 11:24:53 02/23/2009

Serial Number : 000013 Device Name : e-DXC


Hardware Version: B Start Time : 09:08:47 02/23/2009
Software Version: V1.02.01 02/19/2009 Connect Port : SUPV_PORT

[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Display H -> SDH/SONET Setup
J -> PDH Display K -> PDH Setup
P -> Map Display G -> Map Setup
Q -> Alarm Queue M -> Alarm Setup
I -> System Information L -> File Transfer
T -> System Log V -> Store/Retrieve Backup Config
N -> Unit Registration

[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default

>>SPACE bar to refresh or enter a command ===>

The Unit Registration screen will appear. One card is presently in the device. Press the Enter key.

e-DXC === Unit Registration === 10:16:37 02/06/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Slot REG. Model/Mode Card Model Software Version Remark


==== =============== ================ =================== =================
#1 FESW V1.02.02 07/03/2008
#2 E1/T1(32Port) V1.01.02 11/16/2007
#3 B155/622 V1.01.01 10/19/2007
#4
(PRTD = Protected, NP = No Protection)
==== =============== ================ =================== =================
#11
#12
#13
#14
#15 Quad E1 Quad E1 V3.01.03 06/27/2008
#16 Quad E1 V3.01.06 03/28/2008

Command : Card Registration

<< Press ESC key to return to previous menu >>

Use the Tab key to scroll in the Tributary slot that your Ethernet card is plugged into. Press the Enter key.

Command : Card Registration


Unit : Trib-1

The model of card will appear. Press the Enter key.

Command : Card Registration


Unit : Trib-1

Alstom Page 35
e-DXC Ethernet Card

Registered Model : ENETSW-NP

A registration prompt will appear as the registration takes place.

Registration......SUCCESS!

An updated screen will appear that shows the location of the registered card.

e-DXC === Unit Registration === 10:16:37 02/06/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Slot REG. Model/Mode Card Model Software Version Remark


==== =============== ================ =================== =================
#1 ENETSW-NP FESW V1.02.02 07/03/2008
#2 E1/T1(32Port) V1.01.02 11/16/2007
#3 B155/622 V1.01.01 10/19/2007
#4
(PRTD = Protected, NP = No Protection)
==== =============== ================ =================== =================
#11
#12
#13
#14
#15 Quad E1 Quad E1 V3.01.03 06/27/2008
#16 Quad E1 V3.01.06 03/28/2008

Command : Card Registration

<< Press ESC key to return to previous menu >>

If you have other cards to register, do it now. Each plug-in interface card must be registered separately.
Note: The procedure for de-registration is similar to the process for registration except you use the Tab key
to scroll in the command: Card Un-registration.

e-DXC === Unit Registration === 10:16:37 02/06/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Slot REG. Model/Mode Card Model Software Version Remark


==== =============== ================ =================== =================
#1 ENETSW-NP FESW V1.02.02 07/03/2008
#2 E1/T1(32Port) V1.01.02 11/16/2007
#3 B155/622 V1.01.01 10/19/2007
#4
(PRTD = Protected, NP = No Protection)
==== =============== ================ =================== =================
#11
#12
#13
#14
#15 Quad E1 Quad E1 V3.01.03 06/27/2008
#16 Quad E1 V3.01.06 03/28/2008

Command : Card Un-registration

<< Press ESC key to return to previous menu >>

5.3. Choosing a Trib Unit


Press U from the e-DXC Controller Menu to select the Tributary slot that the Ethernet interface card is
plugged into.

e-DXC === Controller Menu === 11:24:53 02/23/2009

Serial Number : 000013 Device Name : e-DXC


Hardware Version: B Start Time : 09:08:47 02/23/2009
Software Version: V1.02.01 02/19/2009 Connect Port : SUPV_PORT

[DISPLAY] [SETUP]

Alstom Page 36
e-DXC Ethernet Card

C -> System Config Display S -> System Config Setup


D -> SDH/SONET Display H -> SDH/SONET Setup
J -> PDH Display K -> PDH Setup
P -> Map Display G -> Map Setup
Q -> Alarm Queue M -> Alarm Setup
I -> System Information L -> File Transfer
T -> System Log V -> Store/Retrieve Backup Config
N -> Unit Registration

[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default

>>SPACE bar to refresh or enter a command ===>

A prompt will appear. Use the Tab key to scroll in the card’s Tributary slot number. Press the Enter key.

==>> Press Tab key to select the unit: 1

The unit menu will appear for that card.

Unit 3 ENETSW === Unit Menu === 11:27:51 02/23/2009

HW Version : D Card State : Initialization Fail


SW Version : V1.02.02 07/03/2008

[DISPLAY] [SETUP]
C -> WAN(VCG) & Link Display M -> Mode Setup
A -> Current Alarm Status S -> WAN(VCG) & Link Setup
P -> Unit Performance R -> Performance Setup/Clear
G -> WAN(VCG) Statistics L -> File Transfer
I -> Switch Status H -> Switch Setup
B -> SNCP/UPSR APS status D -> SNCP/UPSR APS Setup

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

Alstom Page 37
e-DXC Ethernet Card

5.4. Mode Setup

The Unit Menu path for Mode Setup is as follows:

M> Mode Setup

The Mode Setup screen will appear. Use the Tab key to scroll in your setting. Then press the Enter key.

Table 5-1 Mode Setting Options

Field Setting Default Setting Notes


Mode Selection e-line (8FE) e-line (8FE)
e-line(1GE)
e-lan(8FE) e-lan settings must be used if you
e-lan(1GE) wish to use the Ethernet switch
for VLAN
portmap(8FE) Port map settings must be used if
portmap(1GE) you wish to use the Ethernet
switch for Port Mapping

Unit 1 ENETSW === Mode Setup === 16:48:35 01/04/2008


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

Mode Selection : e-line(8FE)

A prompt will ask if you wish to change to this new configuration. Press Y for yes.

>> Change configuration (Y/N)? (Note:to save,please use V-command)

A prompt will advise you that the change was successful.

SUCCESS

Alstom Page 38
e-DXC Ethernet Card

5.5. Store/Retrieve Backup Config

You must save this change. To do so, press E to return to the e-DXC device Controller Menu as shown
below. Then press V from the main menu.

e-DXC === Controller Menu === 17:12:36 01/04/2008

Serial Number : 010525 Device Name : e-DXC


Hardware Version: D Start Time : 15:17:16 01/04/2008
Software Version: V1.03.01 12/19/2007 Connect Port : SUPV_PORT

[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Config Display H -> SDH/SONET Config Setup
I -> System Information M -> Alarm Setup
Q -> Alarm Queue L -> File Transfer
B -> Currently-Active Alarm Summary V -> Store/Retrieve Backup Config
A -> Current Alarm Status G -> Loopback/Diagnostics Setup
P -> SDH/SONET Performance R -> Performance Setup/Clear
T -> System Log N -> Unit Registration
E -> Diagnostics Display

[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default

>>SPACE bar to refresh or enter a command ===>

The Store/Retrieve Configuration screen will appear. Use the arrow keys to move the flashing cursor to
STORE. Press the Enter key. Press Y for yes.

e-DXC ===Store/Retrieve Configuration=== 17:13:56 01/04/2008

>> Select ? *STORE RETRIEVE


>> Store Current Configuration ? [Y/N]

You will be asked to key in your password. The default password is eDXC in upper case letters.
Press the Enter key.

e-DXC ===Store/Retrieve Configuration=== 17:13:56 01/04/2008

>> Select ? *STORE RETRIEVE


==>> Enter password :

The following message will be displayed as the storage process takes place.

>> Select ? *STORE RETRIEVE


===> Saving.......

Press the Esc key to return to the Controller Menu.

Alstom Page 39
e-DXC Ethernet Card

5.6. WAN (VCG) & Link Setup

The Unit Menu path for WAN (VCG) & Link Setup is as follows:

S > WAN (VCG) & Link Setup

Then press one of the following:

A > Payload/LCAS Setup


B > Encapsulation Type Setup
C > Encapsulation Parameter Setup
D > Path Alarm Setup
E > VCG Alarm Threshold Setup
F-> Linkdown Alarm Setup
G > Link Config Setup
H > Customer Information Setup
I > Link Failure Propagation
J -> Inter-Frame Gap(IFG) Setup

Screen by screen setup examples are shown below:

5.6.1. Payload/LCAS Setup

The Unit Menu path for Payload/LCAS Setup is as follows:


S > WAN (VCG) & Link Setup
A > Payload/LCAS Setup

The Payload/LCAS Setup screen will appear. Use the arrow keys to move the cursor to the various fields.
Then use the Tab key to scroll in your settings. Press the Enter key.

Table 5-2 Payload/LCAS Setting Options

VCG Field SDH Payload Default LCAS LCAS


MODE Settings Payload Mode Mode
Setting Default
Setting
WAN1 (GE) Mode 1 TU12, TU12 LCAS, LCAS
WAN2 to 9 (FE) TU3, Non LCAS
AU4/C4,
AU3/C3
Mode 2 TU11, TU11
AU4/C4,
AU3/C3

Alstom Page 40
e-DXC Ethernet Card

Unit 1 EN ETS W = == Pay loa d/L CAS Se tup === 18 :07 :43 11 /24 /20 09
ARRO W K EYS : CUR SOR MO VE , E NTE R K EY : I TEM SEL ECT

SD H M ode : M ode 1

[WA N] [p ayl oad ] [lc as mod e]


WAN 1(G E) : TU 12 LCA S

WAN 2(F E) : TU 12 LCA S


WAN 3(F E) : TU 12 LCA S
WAN 4(F E) : TU 12 LCA S
WAN 5(F E) : TU 12 LCA S
WAN 6(F E) : TU 12 LCA S
WAN 7(F E) : TU 12 LCA S
WAN 8(F E) : TU 12 LCA S
WAN 9(F E) : TU 12 LC A S

Note : M ode 1 sup por ts AU4 /C4 , A U3/ C3, TU 3, TU12


M ode 2 sup por ts AU4 /C4 , A U3/ C3, TU 11

<< P res s E SC key to re tur n t o p rev iou s m enu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

5.6.2. Encapsulation Type Setup

The Unit Menu path for Encapsulation Type Setup is as follows:

S > WAN (VCG) & Link Setup


B > Encapsulation Type Setup

The Encapsulation Type Setup screen will appear. Use the arrow keys to move the cursor to the various
fields. Then use the Tab key to scroll in your settings. Press the Enter key.

Table 5-3 Encapsulation Type Setting Options

Field Encapsulation Type Settings Default Setting


WAN1 (GE) GFP GFP
WAN2 to 9 LAPS
(FE) BCP

Unit 1 ENETSW === Encapsulation Type Setup === 10:21:25 01/07/2008


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

Encapsulation Type

WAN1(GE) : GFP

WAN2(FE) : GFP
WAN3(FE) : GFP
WAN4(FE) : GFP
WAN5(FE) : GFP
WAN6(FE) : GFP
WAN7(FE) : GFP
WAN8(FE) : GFP

Alstom Page 41
e-DXC Ethernet Card

WAN9(FE) : GFP

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

5.6.3. Encapsulation Parameter Setup

The Unit Menu path for Encapsulation Parameter Setup is as follows:

S > WAN (VCG) & Link Setup


C > Encapsulation Parameter Setup

The Encapsulation Parameter Setup screen will appear. Use the arrow keys to move the cursor to the (VCG)
WAN# field. Then key in the WAN# setting. Press the Enter key.

Table 5-4 Encapsulation Parameter Setting Options


Field Setting Range Default Setting
(VCG) WAN# 2 to 9 2

Unit 1 ENETSW === Encapsulation Par Setup === 10:38:26 01/07/2008


ARROW KEYS: CURSOR MOVE, Please Input: 1 to 1, BACKSPACE to edit
(VCG) WAN# : 2

<< Press ESC key to return to previous menu >>

If your encapsulation type is GFP, the GFP Parameter Setup screen will appear. Use the arrow keys to
move the cursor to the various fields. Some settings must be keyed in. Some must be scrolled in using the
Tab key. Press the Enter key.

Table 5-5 GFP Parameter Setting Options

Field Settings Default Setting


Rx PTI 0 to 7 0
Rx EXI 0 to 0xF 0
Rx UPI 0 to 0xFF 01
DELTA 1 to 4 1
Rx Descramble Disable Enable
Rx Payload FCS Check Enable Disable
Rx PTI Check Disable
Rx UPI Check Disable
Tx PTI 0 to 7 0
Tx EXI 0 to 0xF 0
Tx UPI 0 to 0xFF 01
Tx PFI 0 to 1 1
Tx Scramble Disable Enable
Tx Payload FCS Insert Enable Disable
Tx/Rx Payload FCS CRC-32 CRC-32
Mode CRC-16

Unit 1 ENETSW === GFP Parameter Setup === 10:44:43 01/07/2008


ARROW KEYS: CURSOR MOVE, Please Input: 0 to 7, BACKSPACE to edit
(VCG) WAN# : 1

Rx PTI : 0_ Tx PTI : 0

Alstom Page 42
e-DXC Ethernet Card

Rx EXI : 0 Tx EXI : 0
Rx UPI : 01 Tx UPI : 01
DELTA : 1 Tx PFI : 1

Rx Descramble : Enable Tx Scramble : Enable


Rx Payload FCS Check : Disable Tx Payload FCS Insert : Disable
Rx PTI Check : Disable Tx/Rx Payload FCS Mode : CRC-32
Rx UPI Check : Disable

<< Press ESC key to return to previous menu >>

If your encapsulation type is LAPS, the LAPS Parameter Setup screen will appear. Use the arrow keys to
move the cursor to the various fields. Some settings must be keyed in. Some must be scrolled in using the
Tab key. Press the Enter key.

Alstom Page 43
e-DXC Ethernet Card

Table 5-6 LAPS Parameter Setting Options

Field Settings Default Setting


Rx Address 0 to 0xFF 4

Rx Control 0 to 0xFF 03

Rx SAPI MSB 0 to 0xFF FE

Rx SAPI LSB 0 to 0xFF 01

Rx Descramble Disable/Enable Enable


Rx Payload FCS Check Disable/Enable Enable
Rx Address Check Disable/Enable Disable
Rx Control Check Disable/Enable Disable
Rx SAPI Check Disable/Enable Disable
Tx Address 0 to 0xFF 04

Tx Control 0 to 0xFF 03

Tx SAPI MSB 0 to 0xFF FE

Tx SAPI LSB 0 to 0xFF 01

Tx Scramble Disable/Enable Enable


Tx Payload FCS Insert Disable/Enable Enable
Tx/Rx Payload FCS CRC-32 CRC-32
Mode CRC-16

Unit 1 ENETSW === LAPS Parameter Setup === 13:50:07 01/31/2008


ARROW KEYS: CURSOR MOVE, Please Input: 0 to 0xFF, BACKSPACE to edit
(VCG) WAN# : 2

Rx Address : 4_ Tx Address : 04
Rx Control : 03 Tx Control : 03
Rx SAPI MSB : FE Tx SAPI MSB : FE
Rx SAPI LSB : 01 Tx SAPI LSB : 01

Rx Descramble : Enalbe Tx Scramble : Enalbe


Rx Payload FCS Check : Enalbe Tx Payload FCS Insert : Enalbe
Rx Address Check : Disable Tx/Rx Payload FCS Mode : CRC-32
Rx Control Check : Disable
Rx SAPI Check : Disable

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 44
e-DXC Ethernet Card

If your encapsulation type is BCP, the BCP Parameter Setup screen will appear. Use the arrow keys to
move the cursor to the various fields. Some settings must be keyed in. Some must be scrolled in using the
Tab key. Press the Enter key.

Table 5-7 BCP Parameter Setting Options

Field Settings Default Setting


Rx Address 0 to 0xFF FF

Rx Control 0 to 0xFF 03

Rx Protocol MSB 0 to 0xFF 00

Rx Protocol LSB 0 to 0xFF 31

Rx Descramble Disable/Enable Enable


Rx Payload FCS Check Disable/Enable Enable
Rx Address Check Disable/Enable Disable
Rx Control Check Disable/Enable Disable
Rx Protocol Check Disable/Enable Disable
Rx Bit F 0/1 0
Rx Bit Z 0/1 1
Rx Pads 0 to 0xF 0
Rx MAC Type 0 to 0xFF 01
Rx BCP Flags Check Disable/Enable Disable
Rx BCP MAC Type Check Disable/Enable Disable
Tx Address 0 to 0xFF FF

Tx Control 0 to 0xFF 03

Tx Protocol MSB 0 to 0xFF 00

Tx Protocol LSB 0 to 0xFF 31

Tx Scramble Disable/Enable Enable


Tx Payload FCS Insert Disable/Enable Enable
Tx Payload FCS Mode CRC-32, CRC-16 CRC-32
Tx Bit F 0/1 0
Tx Bit Z 0/1 1
Tx Pads 0 to 0xF 0
Tx MAC Type 0 to 0xFF 01

Alstom Page 45
e-DXC Ethernet Card

Unit 1 ENETSW === BCP Parameter Setup === 14:47:18 11/26/2009


ARROW KEYS: CURSOR MOVE, Please Input: 0 to 0xFF, BACKSPACE to edit
(VCG) WAN# : 2

Rx Address : FF Tx Address : FF
Rx Control : 03 Tx Control : 03
Rx Protocol MSB : 00 Tx Protocol MSB : 00
Rx Protocol LSB : 31 Tx Protocol LSB : 31

Rx Descramble : Enable Tx Scramble : Enable


Rx Payload FCS Check : Enable Tx Payload FCS Insert : Enable
Rx Address Check : Disable Tx/Rx Payload FCS Mode : CRC-32
Rx Control Check : Disable
Rx Protocol Check : Disable

Rx Bit F : 0 Tx Bit F : 0
Rx Bit Z : 1 Tx Bit Z : 1
Rx Pads : 0 Tx Pads : 0
Rx MAC Type : 01 Tx MAC Type : 01

Rx BCP Flags Check : Disable


Rx BCP MAC Type Check : Disable

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V.

>> Change configuration (Y/N)? (Note:to save,please use V-command)

5.6.4. Path Alarm Setup

The Unit Menu path for Path Alarm Setup is as follows:

S > WAN (VCG) & Link Setup


D > Path Alarm Setup

The Path Alarm Setup screen will appear. Use the arrow keys to move the cursor to the various fields. Then
use the Tab key to scroll in your settings. Press the Enter key.

Table 5-8 Path Alarm Setting Options 1

Field Settings Default Setting


(VCG) WAN# 2 to 9 2
path low-order low-order
hi-order

Unit 1 ENET === Alarm Mask Setup === 11:12:47 01/07/2008


ARROW KEYS: CURSOR MOVE, Please Input: 1 to 1, BACKSPACE to edit

(VCG) WAN# 2 path : low-order

<< Press ESC key to return to previous menu >>

An advanced Path Alarm Setup screen will appear. Use the arrow keys to move the cursor to the various
fields. Then use the Tab key to scroll in your settings. Press the Enter key.

Alstom Page 46
e-DXC Ethernet Card

Table 5-9 Path Alarm Setting Options 2

Low-order Alarm Alarm Relay Relay Severity Severity


Path Type Settings Default Settings Default Settings Default
TU-LOP ENABLED ENABLED ENABLED DISABLED INFO MAJR
TU-AIS DISABLED ENABLED DISABLED MINR MAJR
LP-UNEQ DISABLED MAJR INFO
LP-RDI-P DISABLED CRIT INFO
LP-RDI-S DISABLED INFO
LP-RDI-C DISABLED INFO
LP-REI DISABLED INFO
LP-BIP DISABLED INFO

Hi-order Alarm Alarm Relay Relay Severity Severity


Path Type Settings Default Settings Default Settings Default
AU-LOP ENABLED ENABLED ENABLED DISABLED INFO MAJR
AU-AIS DISABLED ENABLED DISABLED MINR MAJR
HP-UNEQ DISABLED MAJR INFO
HP-RDI-P DISABLED CRIT INFO
HP-RDI-S DISABLED INFO
HP-RDI-C DISABLED INFO
HP-B3-REI DISABLED INFO
HP-B3-BIP DISABLED INFO

Unit 1 ENETSW === Alarm Mask Setup === 11:33:51 01/07/2008


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

(VCG) WAN# 1 path : low-order

type alarm relay severity


TU-LOP ENABLED DISABLED MAJR
TU-AIS ENABLED DISABLED MAJR
LP-UNEQ DISABLED DISABLED INFO
LP-RDI-P DISABLED DISABLED INFO
LP-RDI-S DISABLED DISABLED INFO
LP-RDI-C DISABLED DISABLED INFO
LP-REI DISABLED DISABLED INFO
LP-BIP DISABLED DISABLED INFO

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V.

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 47
e-DXC Ethernet Card

5.6.5. WAN (VCG) Alarm Threshold Setup

The Unit Menu path for WAN (VCG) Alarm Threshold Setup is as follows:

S > WAN (VCG) & Link Setup


E > WAN (VCG) Alarm Threshold Setup

The WAN (VCG) Alarm Threshold Setup screen will appear. Use the arrow keys to move the cursor to the
various fields. Then use the Tab key to scroll in your settings. Threshold settings must be keyed in. Press
the Enter key.

Table 5-10 WAN (VCG) Alarm Threshold Setting Options

Field En/Dis En/Dis Severity Severity Threshold Threshold


Settings Default Settings Default Settings Default
Errored FCS Count EN DIS INFO MINR 1 to 99999 00100
FIFO Overflow DIS MINR
Frame Count MAJR
Dropped Frame Count CRIT

Unit 1 ENETSW === VCG Alarm Threshold Setup === 12:39:27 01/07/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

En/Dis severity Threshold


Errored FCS count DIS MINR 00100
FIFO overflow frame count DIS MINR 00100
dropped frame count DIS MINR 00100

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 48
e-DXC Ethernet Card

5.6.6. Linkdown Alarm Setup

The Unit Menu path for Linkdown Alarm Setup is as follows:

S > WAN (VCG) & Link Setup


F-> Linkdown Alarm Setup

The Linkdown Alarm Setup screen will appear. Use the arrow keys to move the cursor to the various fields.
Then use the Tab key to scroll in your settings. Press the Enter key.

Table 5-11 Linkdown Alarm Setting Options

Port Alarm Alarm Relay Relay Severity Severity


Settings Default Settings Default Settings Default
LAN1 to 9 ENABLED ENABLED ENABLED DISABLED INFO MINR
DISABLED DISABLED MINR
MAJR
CRIT

Unit 1 ENETSW === Linkdown Mask Setup === 12:46:33 01/07/2008


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

port alarm relay severity


-----------------------------------------
LAN1 ENABLED DISABLED MINR
LAN2 ENABLED DISABLED MINR
LAN3 ENABLED DISABLED MINR
LAN4 ENABLED DISABLED MINR
LAN5 ENABLED DISABLED MINR
LAN6 ENABLED DISABLED MINR
LAN7 ENABLED DISABLED MINR
LAN8 ENABLED DISABLED MINR
LAN9 ENABLED DISABLED MINR

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 49
e-DXC Ethernet Card

5.6.7. Link Config Setup

The Unit Menu path for Link Config Setup is as follows:

S > WAN (VCG) & Link Setup


G > Link Config Setup

The Link Config Setup screen will appear. Use the arrow keys to move the cursor to the various fields. Then
use the Tab key to scroll in your settings. Press the Enter key.

Table 5-12 Link Config Setting Options

Port Link Config Settings Default Setting


LAN1 Auto negotiation Auto negotiation
100M full-duplex
10M full-duplex
100M half-duplex
10M half-duplex
1000M full-duplex
LAN2-9 Auto negotiation Auto negotiation
100M full-duplex
10M full-duplex
100M half-duplex
10M half-duplex

Unit 1 ENETSW === Link Config Setup === 13:29:44 01/07/2008


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

port link config


----------------------------
LAN1 Auto negotiation
LAN2 Auto negotiation
LAN3 Auto negotiation
LAN4 Auto negotiation
LAN5 Auto negotiation
LAN6 Auto negotiation
LAN7 Auto negotiation
LAN8 Auto negotiation
LAN9 Auto negotiation

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 50
e-DXC Ethernet Card

5.6.8. Customer Information Setup

The Unit Menu path for Customer Information Setup is as follows:

S > WAN (VCG) & Link Setup


H > Customer Information Setup

The Customer Information Setup screen will appear. Use the arrow keys to move the cursor to the various
fields. Then key in the customer name for each LAN. Press the Enter key.

Unit 1 ENETSW === Customer Information Setup === 13:35:21 01/07/2008


ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort

Port# Customer Information


LAN1 name of link#1______
LAN2 name of link#2
LAN3 name of link#3
LAN4 name of link#4
LAN5 name of link#5
LAN6 name of link#6
LAN7 name of link#7
LAN8 name of link#8
LAN9 name of link#9

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

5.6.9. Link Failure Propagation

Note: Local LAN Port failure is reflected upstream at the WAN Port. The Ethernet port of each device is
monitored. If a link failure is detected at either device a signal will automatically be sent to the other device
to shut down the corresponding Ethernet port. Thus, the shut down of an Ethernet port is propagated.

Similarly, if WAN (VCG) port failure occurs, link failure propagation will shut down the corresponding LAN
ports. Link Failure Propagation is for E-line mode only.

The Unit Menu path for Link Fail Propagation is as follows:

S >WAN(VCG) & Link Setup


I > Link Failure Propagation

Alstom Page 51
e-DXC Ethernet Card

Table 5-13 Link Failure Propagation Setting Options

Field Settings Default Setting Notes


WAN (VCG) Lost
Propagation ENABLED,
DISABLED
Remote Link Down DISABLED Remote Link Down
Propagation Propagation is only
Remote Link Down 1 to 5 Sec. 1 sec. supported in GFP
Guard Time mode.

Unit 1 ENET === Link Fail Propagation Setup === 21:16:02 O7/01/2008
ARROW KEYS: CURSOR MOVE, ENTER KEY: ITEM SELECT

Wan(VCG) Lost PROPAGATION : DISABLED


Remote link Down Propagation : DISABLED
Remote Link Down Guard Time : 1 second

<< Press ESC key to return to previous menu >>

5.5.10 Inter-Frame Gap (IFG) Setup

The Unit Menu path for Inter-Frame Gap Setup is as follows:

S >WAN(VCG) & Link Setup


J > Inter-Frame Gap (IFG) Setup

The Inter-Frame Gap (IFG) Setup screen will appear. Input your IFG settings and press the Enter key.

Table 5-14 Inter-Frame Gap (IFG) Setting Options

Port Fields IFG Settings Default Setting


LAN1 to LAN 9 80, 88, 96 96

Unit 1 ENET === Inter-Frame Gap(IFG) Setup === 04:21:52 09/04/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

Port IFG (Bit Times)


------ ---------------
LAN1 96
LAN2 96
LAN3 96
LAN4 96
LAN5 96
LAN6 96
LAN7 96
LAN8 96
LAN9 96

<< Press ESC key to return to previous menu >>

Alstom Page 52
e-DXC Ethernet Card

5.7. Performance Setup/Clear

The Unit Menu path for Performance Setup/Clear is as follows:

R > Performance Setup/Clear

Then press one of the following:

A > Clear Performance Data


B > Performance Threshold Setup

Screen by screen setup examples are shown below:

5.7.1. Clear Performance Data

The Unit Menu path for Clear Performance Data is as follows:

R > Performance Setup/Clear


A > Clear Performance Data

A prompt will ask if you want to clear the performance data. Press Y for Yes or N for No. Press the Enter
key.

Unit 1 ENETSW === Performance Setup/Clear === 13:36:59 01/07/2008

A -> Clear Performance Data


B -> Performance Threshold Setup

>> Clear performance data - are you sure [Y/N] ?

Alstom Page 53
e-DXC Ethernet Card

5.7.2. Performance Threshold Setup

The Unit Menu path for Performance Threshold Setup is as follows:

R > Performance Setup/Clear


B > Performance Threshold Setup

The Performance threshold Cross Alarm Setup screen will appear. Use the arrow keys to move the cursor to
the various fields. Then use the Tab key to scroll in your settings. Press the Enter key.

Table 5-15 Performance Threshold Setting Options

Monitor Point EN/DIS EN/DIS Severity Severity Threshold Threshold


Settings Default Settings Default Settings Default
HP-BIP(B3) EN DIS INFO INFO 1 to 99999 02400
HP-REI DIS MINR 02400
LP-BIP(V5) MAJR 00600
LP-REI(V5 CRIT 00600
LP-BIP(B3) 02400
LP-REI(B3) 19200

Unit 1 ENETSW === Perf. Threshold Cross Alarm Setup ===13:38:31 01/07/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Monitor Point En/Dis severity Threshold


HP-BIP(B3) DIS INFO 02400
HP-REI DIS INFO 02400
LP-BIP(V5) DIS INFO 00600
LP-REI(V5) DIS INFO 00600
LP-BIP(B3) DIS INFO 02400
LP-REI(B3) DIS INFO 19200

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 54
e-DXC Ethernet Card

5.8. File Transfer

The Unit Menu path for File Transfer is as follows:

L > File Transfer

Then press one of the following:

A > Unit Download Firmware


B > Copy Firmware to Standby Unit

Screen by screen setup examples are shown below:

5.8.1. Unit Download Firmware

The Unit Menu path for Unit Download Firmware is as follows:

L > File Transfer


A > Unit Download Firmware

The Unit Download Firmware setup screen will appear. Use the arrow keys to move the cursor to the
various fields. Key in the TFTP Server IP address and a Firmware File Name. Press the Enter key.

Unit 1 ENETSW === Unit Download Firmware === 14:46:05 11/03/2007


ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort

Firmware 1 Version : V1.01.01 10/19/2007


Firmware 2 Version : V1.01.01 10/19/2007
Current Firmware Bank: 1
Next Boot Firmware : 1
TFTP Server IP : 10.3.11.1
Firmware File Name : O94RENET.RUN____________________________________________

<< Press ESC key to abort, ENTER key to Upload/Download Firmware >>

A prompt will ask if you really want to download. Press Y for yes.

Really want to Download ?

A message will be displayed as the download is in progress and a new message will appear once the
download is complete.

Unit 1 ENETSW === Unit Download Firmware === 14:48:39 11/03/2007


ARROW KEYS: CURSOR MOVE, BACKSPACE to edit, ESC to abort

Firmware 1 Version : V1.01.01 10/19/2007


Firmware 2 Version : V1.01.01 10/19/2007
Current Firmware Bank: 1
Next Boot Firmware : 1
TFTP Server IP : 010.003.011.001
Firmware File Name : O94RENET.RUN

14:48:45 11/03/07 Downloading firmware ........619148 bytes received.


14:48:55 11/03/07 Send firmware file to trib-5 ........Download Complete.

<< Press ESC key to abort, ENTER key to Upload/Download Firmware >>

Alstom Page 55
e-DXC Ethernet Card

5.8.2. Copy Firmware to Standby Unit

The Unit Menu path for Firmware to Standby Unit is as follows:

L > File Transfer


B > Copy Firmware to Standby Unit

The Copy firmware to standby unit screen will appear. A prompt will ask if you are sure. Press Y for yes.
The copying will occur immediately.

Unit 1 ENET === Copy firmware to standby unit === 14:50:53 11/03/2007

Copy firmware to standby unit - are you sure ? Y \ 605


Copy Complete.

<< Press ESC key to return to previous menu >>

5.9. Switch Setup

The Unit Menu path for Switch Setup is as follows:

H > Switch Setup

The following VLAN Setup screen will appear.

Unit 3 ENETSW === Switch Setup === 11:33:10 02/23/2009

A -> VLAN Setup


B -> PortMap Setup
C -> Port Trunk Setup
D -> MSTP/RSTP Setup
E -> Flow Control Setup
F -> Qos Setup
G -> IGMP Setup

<< Press ESC key to return to Main Menu or enter a command >>

Alstom Page 56
e-DXC Ethernet Card

5.9.1. VLAN Setup

The Unit Menu path for VLAN Setup is as follows:

H > Switch Setup


A > VLAN Setup

The VLAN Setup screen will appear. Press A, B, or C.

Note: You will not be able to access this screen unless you have already set the Ethernet Switch
card to an E-LAN mode setting. (Please refer to Section 5.4, Mode Setup).

Unit 1 ENETSW === VLAN Setup === 18:02:53 01/15/2008

A -> VLAN Tag Protocol ID Setup


B -> VLAN Port Configuration Setup
C -> VLAN Port Association Setup

<< Press ESC key to return to Main Menu or enter a command >>

5.9.1.1. VLAN Tag Protocol ID Setup

The Unit Menu path for VLAN Tag Protocol ID Setup is as follows:

H > Switch Setup


A > VLAN Setup
A -> VLAN Tag Protocol ID Setup

The VLAN Tag Protocol ID Setup screen will appear. Key in the VLAN TPID setting. Press the Enter key.

Table 5-16 VLAN Tag Protocol ID Setting Options

Field Settings Default Setting Notes


VLAN TPID User determined 0x8100 Allowable characters
are: 0 to 9, A to F.

Unit 1 ENETSW === VLAN Tag Protocol ID Setup === 10:24:50 01/16/2008
ARROW KEYS: CURSOR MOVE, Please Input: 0 to 9, A to F, BACKSPACE to edit

VLAN TPID : 0x8100

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 57
e-DXC Ethernet Card

5.9.1.2. VLAN Port Configuration Setup

The Unit Menu path for VLAN Port Configuration Setup is as follows

H > Switch Setup


A > VLAN Setup
B -> VLAN Port Configuration Setup

The VLAN Port Configuration Setup screen will appear.


Use the Tab key to scroll in the Port# setting. Press the Enter key.

Table 5-17 VLAN Tag Protocol ID Setting Options for Screen 1

Field Settings Default Setting


Port# WAN1(GE) WAN1(GE)
WAN2(FE) to
WAN9(FE)
LAN1(GE)
LAN2(FE) to
LAN9(FE)

Unit 1 ENETSW === VLAN Port Configuration Setup === 10:55:54 01/16/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : WAN1(GE)

<< Press ESC key to return to previous menu >>

An updated screen will appear. Enter your settings and press the Enter key.

Table 5-18 VLAN Tag Protocol ID Setting Options for Screen 2

Field Settings Default Setting Notes


Port VLAN ID(PVID) Setting range is: 1 to 0001 Key in your setting
4094
Port untagged out Enable Disable
Disable

Unit 1 ENETSW === VLAN Port Configuration Setup === 11:03:26 01/16/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port# : WAN1(GE)

Port VLAN ID(PVID) : 0001

Port untagged out : Disable

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

Alstom Page 58
e-DXC Ethernet Card

5.9.1.3. VLAN Port Association Setup


The Unit Menu path for VLAN Port Port Association Setup is as follows:

H > Switch Setup


A > VLAN Setup
C -> VLAN Port Association Setup

The VLAN Port Association Setup screen will appear. Key in your setting. Press the Enter key.

Table 5-19 VLAN Port Association ID Setting Options for Screen 1


Field Settings Default Setting Notes
VID# Setting range is: 1 to 0001 Key in your setting
4094

Unit 1 ENETSW === VLAN Port Association Setup === 11:25:43 01/16/2008
ARROW KEYS: CURSOR MOVE, Please Input: 1 to 4095, BACKSPACE to edit
VID# : 0001

<< Press ESC key to return to previous menu >>

An updated screen will appear. Enter your settings and press the Enter key.

Table 5-20 VLAN Port Association ID Setting Options for Screen 2


Field Settings Default Setting
WAN1(GE) ON, OFF ON
WAN2(FE) to
WAN9(FE)
LAN1(GE)
LAN2(FE) to
LAN9(FE)
Filter Broadcast No, Yes No

Unit 1 ENETSW === VLAN Port Association Setup === 11:25:43 01/16/2008
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
VID# : 0001
WAN1(GE) : ON
WAN2(FE) : ON
WAN3(FE) : ON
WAN4(FE) : ON
WAN5(FE) : ON
WAN6(FE) : ON
WAN7(FE) : ON
WAN8(FE) : ON
WAN9(FE) : ON
LAN1(GE) : ON
LAN2(FE) : ON
LAN3(FE) : ON
LAN4(FE) : ON
LAN5(FE) : ON
LAN6(FE) : ON
LAN7(FE) : ON
LAN8(FE) : ON
LAN9(FE) : ON
Filter Broadcast: No

<< Press ESC key to return to previous menu >>

Alstom Page 59
e-DXC Ethernet Card

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

5.9.2. Port Map Setup

The Unit Menu path for Port Map Setup is as follows:

H > Switch Setup


B > Port Map Setup

The Port Map Setup screen will appear. Press A or B.

Note: You will not be able to access this screen unless you have already set the Ethernet Switch
card to the Port Map mode setting. (Please refer to Section 5.4, Mode Setup).

Unit 1 ENETSW === PortMap Setup === 11:45:16 01/16/2008

A -> WAN PortMap Setup


B -> LAN PortMap Setup

<< Press ESC key to return to Main Menu or enter a command >>

5.9.2.1. WAN PortMap Setup

The Unit Menu path for WAN PortMap Setup is as follows:

A > WAN PortMap Setup

The WAN PortMap Setup screen will appear. Scroll in your settings. Press the Enter key.

Table 5-21 WAN Port Map Setting Options


Field Settings Default Setting
WAN1(GE) on, off off
WAN2(FE) to
WAN9(FE)
LAN1(GE)
LAN2(FE) to
LAN9(FE)

Unit 1 ENETSW === WAN PortMap Setup === 11:57:23 01/16/2008


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT
port WAN1G WAN2 WAN3 WAN4 WAN5 WAN6 WAN7 WAN8 WAN9
destination
WAN1(GE) off off off off off off off off off
WAN2(FE) off off off off off off off off off
WAN3(FE) off off off off off off off off off
WAN4(FE) off off off off off off off off off
WAN5(FE) off off off off off off off off off
WAN6(FE) off off off off off off off off off
WAN7(FE) off off off off off off off off off
WAN8(FE) off off off off off off off off off
WAN9(FE) off off off off off off off off off
LAN1(GE) off off off off off off off off off
LAN2(FE) off off off off off off off off off

Alstom Page 60
e-DXC Ethernet Card

LAN3(FE) off off off off off off off off off
LAN4(FE) off off off off off off off off off
LAN5(FE) off off off off off off off off off
LAN6(FE) off off off off off off off off off
LAN7(FE) off off off off off off off off off
LAN8(FE) off off off off off off off off off
LAN9(FE) off off off off off off off off off

<< Press ESC key to return to previous menu >>

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

5.9.2.2. LAN Port Map Setup

The Unit Menu path for LAN PortMap Setup is as follows:

B > LAN PortMap Setup

The LAN PortMap Setup screen will appear. Scroll in your settings. Press the Enter key.

Table 5-22 LAN Port Map Setting Options

Field Settings Default Setting


WAN1(GE) on, off off
WAN2(FE) to
WAN9(FE)
LAN1(GE)
LAN2(FE) to
LAN9(FE)

Unit 1 ENETSW === LAN PortMap Setup === 12:15:50 01/16/2008


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT
port LAN1G LAN2 LAN3 LAN4 LAN5 LAN6 LAN7 LAN8 LAN9
destination
WAN1(GE) off off off off off off off off off
WAN2(FE) off off off off off off off off off
WAN3(FE) off off off off off off off off off
WAN4(FE) off off off off off off off off off
WAN5(FE) off off off off off off off off off
WAN6(FE) off off off off off off off off off
WAN7(FE) off off off off off off off off off
WAN8(FE) off off off off off off off off off
WAN9(FE) off off off off off off off off off
LAN1(GE) off off off off off off off off off
LAN2(FE) off off off off off off off off off
LAN3(FE) off off off off off off off off off
LAN4(FE) off off off off off off off off off
LAN5(FE) off off off off off off off off off
LAN6(FE) off off off off off off off off off
LAN7(FE) off off off off off off off off off
LAN8(FE) off off off off off off off off off
LAN9(FE) off off off off off off off off off

Alstom Page 61
e-DXC Ethernet Card

<< Press ESC key to return to previous menu

The following prompt will appear. Press Y to change the configuration. If you want to save this configuration
you must return to the e-DXC Controller Menu and press V

>> Change configuration (Y/N)? (Note:to save,please use V-command)

5.9.3. Port Trunk Setup

The Unit Menu path for Port Trunk Setup is as follows:

H > Switch Setup


C > Port Trunk Setup

The Port Trunk Setup screen will appear. Scroll in your settings. Press the Enter key.

Table 5-23 Port Trunk Setting Options

Field Settings Default Setting


Member/leader port WAN1 to WAN9, none
LAN1 to LAN9, none
WAN1(GE) on, off off
WAN2(FE) to
WAN9(FE)
LAN1(GE)
LAN2(FE) to
LAN9(FE)

Unit 1 ENETSW === Port Trunk Setup === 12:04:34 09/30/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT
trunk1 trunk2 trunk3 trunk4
member\leader port none none none none
WAN1 off off off off
WAN2 off off off off
WAN3 off off off off
WAN4 off off off off
WAN5 off off off off
WAN6 off off off off
WAN7 off off off off
WAN8 off off off off
WAN9 off off off off
LAN1 off off off off
LAN2 off off off off
LAN3 off off off off
LAN4 off off off off
LAN5 off off off off
LAN6 off off off off
LAN7 off off off off
LAN8 off off off off
LAN9 off off off off

<< Press ESC key to return to previous menu >>

Alstom Page 62
e-DXC Ethernet Card

5.9.4. MSTP/RSTP Setup

The Unit Menu path for MSTP/RSTP Setup is as follows:

H > Switch Setup


D > MSTP/RSTP Setup

5.9.4.1. MSTP Region/CIST Setup

H > Switch Setup


D > MSTP/RSTP Setup
A> MSTP Region/CIST Setup

The MSTP Region/CIST Setup screen will appear. Key or scroll in your settings as required. Press the Enter
key.
Table 5-24 MSTP Region/CIST Setting Options

Field Settings Default Setting Notes


STP MSTP enable, Disable disable
Region Name MST name
Revision 0 to 65535 1
Bridge ID MAC ADDR Display only
Bridge ID Priority 0, 4096, 8192, 12288, 32768
16384, 20480, 24576,
28672, 32768, 36864,
40060, 45056, 49152,
53248, 57344, 61440
Bridge Max Age 6 to 40 20
Hello Time 1 to 10 2
Forward Delay 4 to 30 15

Note: Bridge max. age must be ≥ 2 x (Hello time+1) and ≤ 2 x (Forward Delay – 1).

Unit 2 ENETSW === MSTP Region/CIST Setup === 18:27:58 03/26/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

STP : MSTP enable

Region Name : MSTname


Revision : 00001

Bridge ID MAC ADDR : 00-88-16-A5-0D-4D


Bridge ID Priority : 32768 (MST instance 0)
Bridge Max Age : 20 sec Hello Time : 02 sec Forward Delay : 15 sec

<< Press ESC key to return to previous menu >>

Alstom Page 63
e-DXC Ethernet Card

5.9.4.2. Spanning Tree Port Setup

H > Switch Setup


D > MSTP/RSTP Setup
B> Spanning Tree Port Setup

The Spanning Tree Port Setup screen will appear. Scroll in your settings. Press the Enter key.

Table 5-25 Spanning Tree Port Setting Options

Field Settings Default Setting


WAN1(GE) enable, disable enable
WAN2(FE) to WAN9(FE)
LAN1(GE)
LAN2(FE) to LAN9(FE)

Unit 3 ENETSW === Spanning Tree Port Setup === 10:41:06 02/24/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Port Spantree
--------- -----------
WAN1(GE) enable
WAN2(FE) enable
WAN3(FE) enable
WAN4(FE) enable
WAN5(FE) enable
WAN6(FE) enable
WAN7(FE) enable
WAN8(FE) enable
WAN9(FE) enable
LAN1(GE) enable
LAN2(FE) enable
LAN3(FE) enable
LAN4(FE) enable
LAN5(FE) enable
LAN6(FE) enable
LAN7(FE) enable
LAN8(FE) enable
LAN9(FE) enable

<< Press ESC key to return to previous menu >>

Alstom Page 64
e-DXC Ethernet Card

5.9.4.3. MSTP Instance/Vlan Setup

H > Switch Setup


D > MSTP/RSTP Setup
C> MSTP Instance/Vlan Setup

The MSTP Instance/Vlan Setup screen will appear. Type in your settings. Press the Enter key.

Table 5-26 MSTP Instance/Vlan Setting Options

Field Settings Default Setting Notes


MST Instance 1 to 64 1
Priority Display only

Unit 2 ENETSW === MSTP Instance/Vlan Setup === 18:22:01 03/26/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
MST instance :01
Priority : 32768
Add from Vlan#0001 to Vlan#0001

<< Press ESC key to return to previous menu >>

Alstom Page 65
e-DXC Ethernet Card

5.9.4.4. MSTP Instance/Priority Setup

H > Switch Setup


D > MSTP/RSTP Setup
D> MSTP Instance/Priority Setup

The MSTP Instance/Priority Setup screen will appear. Key or scroll in your settings as required. Press the
Enter key.

Table 5-27 MSTP Instance/Priority Setting Options

Field Settings Default Setting Note


MST Instance 1 to 64 1
Priority 0, 4096, 32678 Scroll in your setting
8192,…61440 (increments of 4096)

Unit 2 ENETSW === MSTP Instance/Priority Setup === 18:22:59 03/26/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
MST instance :01
Priority : 32768

Vlan mapping
------------------------------
1

<< Press ESC key to return to previous menu >>

5.9.4.5. MSTP/RSTP Port Setup

H > Switch Setup


D > MSTP/RSTP Setup
E> MSTP/RSTP Port Setup

Note: MSTP is only available in e-lan mode. RSTP is only available in e-line and portmap
modes. Please refer to Section 5.5, Mode Setup, for instructions on changing the mode.

If you are in e-lan mode the MSTP port setup screen will appear. Type in a setting for the MST instance.
Press the Enter key.

Table 5-28 MSTP Port Setting Options

Field Setting Options Default Setting


MST Instance 0 to 64 0

Unit 5 ENETSW === MSTP Port Setup === 13:44:37 09/30/2009


ARROW KEYS: CURSOR MOVE, Please Input: 0 to 64, BACKSPACE to edit
MST instance :00

<< Press ESC key to return to previous menu >>

Alstom Page 66
e-DXC Ethernet Card

MSTP Instance 0

If you selected MSTP Instance 0, the following MSTP Port Setup screen will appear.

Table 5-29 MSTP Port Setting Options (Instance 0)

Setting Type Setting Options Default Setting Notes


Role Display only
State Display only
Cost 1 to 200000000 200000
Prio 0, 16, 32,…240 128 Scroll in your setting
(increments of 16)
Edg-P No, Yes No
Type auto, share, pt to pt auto
Boundary Display only

Unit 5 ENETSW === MSTP Port Setup === 13:44:37 09/30/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port Role State Cost Prio Edg-P Type Boundary
---------- ---------- ----- --------- ---- ----- -------- ------------
WAN1(GE) disabled Dis 000200000 128 No auto Internal
WAN2(FE) disabled Dis 000200000 128 No auto Internal
WAN3(FE) designated Fwd 000200000 128 No auto Internal
WAN4(FE) designated Fwd 000200000 128 No auto Internal
WAN5(FE) designated Fwd 000200000 128 No auto Internal
WAN6(FE) designated Fwd 000200000 128 No auto Internal
WAN7(FE) designated Fwd 000200000 128 No auto Internal
WAN8(FE) designated Fwd 000200000 128 No auto Internal
WAN9(FE) designated Fwd 000200000 128 No auto Internal
LAN1(GE) designated Fwd 000200000 128 No auto Internal
LAN2(FE) designated Fwd 000200000 128 No auto Internal
LAN3(FE) designated Fwd 000200000 128 No auto Internal
LAN4(FE) designated Fwd 000200000 128 No auto Internal
LAN5(FE) designated Fwd 000200000 128 No auto Internal
LAN6(FE) designated Fwd 000200000 128 No auto Internal
LAN7(FE) designated Fwd 000200000 128 No auto Internal
LAN8(FE) designated Fwd 000200000 128 No auto Internal
LAN9(FE) designated Fwd 000200000 128 No auto Internal
MST instance:0
<< Press ESC key to return to previous menu >>

MSTP Instance 1 to 64

If you selected MSTP Instance 1 to 64, the following MSTP Port Setup screen will appear.

Table 5-30 MSTP Port Setting Options (Instance 1 to 64)

Setting Type Setting Options Default Setting Note


Role Display only
State Display only
Cost 1 to 200000000 200000
Prio 0, 16, 32,…240 128 Scroll in your setting
(increments of 16)

Alstom Page 67
e-DXC Ethernet Card

Unit 5 ENETSW === MSTP Port Setup === 10:01:53 10/01/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port Role State Cost Prio
---------- ---------- ----- --------- ----
WAN1(GE) disabled Dis 000200000 128
WAN2(FE) disabled Dis 000200000 128
WAN3(FE) disabled Dis 000200000 128
WAN4(FE) disabled Dis 000200000 128
WAN5(FE) disabled Dis 000200000 128
WAN6(FE) disabled Dis 000200000 128
WAN7(FE) disabled Dis 000200000 128
WAN8(FE) disabled Dis 000200000 128
WAN9(FE) disabled Dis 000200000 128
LAN1(GE) disabled Dis 000200000 128
LAN2(FE) disabled Dis 000200000 128
LAN3(FE) disabled Dis 000200000 128
LAN4(FE) disabled Dis 000200000 128
LAN5(FE) disabled Dis 000200000 128
LAN6(FE) disabled Dis 000200000 128
LAN7(FE) disabled Dis 000200000 128
LAN8(FE) disabled Dis 000200000 128
LAN9(FE) disabled Dis 000200000 128
MST instance:1
<< Press ESC key to return to previous menu >>

If you are in e-line or portmap mode the RSTP port setup screen will appear. Key or scroll in your settings as
required. Press the Enter key.

Table 5-31 MSTP Port Setting Options

Setting Type Setting Options Default Setting Notes


Role Display only
State Display only
Cost 1 to 200000000 200000
Prio 0, 16, 32,…240 128 Scroll in your setting
(increments of 16)
Edg-P No, Yes No
Type auto, share, pt to pt auto
Boundary Display only

Unit 5 ENETSW === RSTP Port Setup === 09:46:33 10/01/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Port Role State Cost Prio Edg-P Type
---------- ---------- ----- --------- ---- ----- --------
WAN1(GE) disabled Fwd 000200000 128 No auto
WAN2(FE) disabled Fwd 000200000 128 No auto
WAN3(FE) disabled Fwd 000200000 128 No auto
WAN4(FE) disabled Fwd 000200000 128 No auto
WAN5(FE) disabled Fwd 000200000 128 No auto
WAN6(FE) disabled Fwd 000200000 128 No auto
WAN7(FE) disabled Fwd 000200000 128 No auto
WAN8(FE) disabled Fwd 000200000 128 No auto
WAN9(FE) disabled Fwd 000200000 128 No auto
LAN1(GE) disabled Fwd 000200000 128 No auto

Alstom Page 68
e-DXC Ethernet Card

LAN2(FE) disabled Fwd 000200000 128 No auto


LAN3(FE) disabled Fwd 000200000 128 No auto
LAN4(FE) disabled Fwd 000200000 128 No auto
LAN5(FE) disabled Fwd 000200000 128 No auto
LAN6(FE) disabled Fwd 000200000 128 No auto
LAN7(FE) disabled Fwd 000200000 128 No auto
LAN8(FE) disabled Fwd 000200000 128 No auto
LAN9(FE) disabled Fwd 000200000 128 No auto

<< Press ESC key to return to previous menu >>

5.9.4.6. RSTP Bridge Setup

H > Switch Setup


D > MSTP/RSTP Setup
F> RSTP Bridge Setup

The RSTP Bridge Setup screen will appear. Key or scroll in your settings as required. Press the Enter key.

Table 5-32 RSTP Bridge Setting Options

Field Setting Options Default Setting Notes


STP RSTP Enable, Disable Disable
Bridge ID MAC ADDR Display only
Bridge Max Age Setting range is: 6 to 40 20 sec.
Hello Time Setting range is:1 to 10 2 sec.
Forward Delay Setting range is:4 to 15 sec.
300

Note: Bridge max. age must be ≥ 2 x (Hello time+1) and ≤ 2 x (Forward Delay – 1).

Unit 2 ENETSW === RSTP Bridge Setup === 18:24:51 03/26/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

STP : Disable

Bridge ID MAC ADDR : 00-88-16-A5-0D-4D


Bridge ID Priority : 32768
Bridge Max Age : 20 sec Hello Time : 02 sec Forward Delay : 15 sec

<< Press ESC key to return to previous menu >>

5.9.5. Flow Control Setup

H > Switch Setup


E > Flow Control Setup

Alstom Page 69
e-DXC Ethernet Card

The Flow Control Setup screen will appear. Scroll in your settings as required. Press the Enter key.

Table 5-33 Flow Control Setting Options

Setting Type Setting Options Default Setting


Flow Control ON, OFF ON
Asymmetric ON, OFF OFF

Unit 3 ENETSW === Flow Control Setup === 13:28:35 02/23/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

port Flow control Asymmetric


WAN1(GE) : ON OFF
WAN2(FE) : ON OFF
WAN3(FE) : ON OFF
WAN4(FE) : ON OFF
WAN5(FE) : ON OFF
WAN6(FE) : ON OFF
WAN7(FE) : ON OFF
WAN8(FE) : ON OFF
WAN9(FE) : ON OFF
LAN1(GE) : ON OFF
LAN2(FE) : ON OFF
LAN3(FE) : ON OFF
LAN4(FE) : ON OFF
LAN5(FE) : ON OFF
LAN6(FE) : ON OFF
LAN7(FE) : ON OFF
LAN8(FE) : ON OFF
LAN9(FE) : ON OFF

<< Press ESC key to return to previous menu >>

5.9.6. QoS Setup

H > Switch Setup


F > QoS Setup

Unit 3 ENETSW === Qos Setup === 13:28:49 02/23/2009

A -> Class of Service Setup


B -> TCP/UDP Port Access Control
C -> Transmission Scheduling
D -> Transmission WRED Setup
E -> Rate Control Setup

<< Press ESC key to return to Main Menu or enter a command >>

5.9.6.1. Class of Service Setup

H > Switch Setup


F > QoS Setup
A > Class of Service Setup

Unit 3 ENETSW = Class of Service Setup = 13:29:28 02/23/2009

Alstom Page 70
e-DXC Ethernet Card

A -> Priority Mode Setup


B -> Fixed Priority Setup
C -> Vlan Tag Priority Setup
D -> TOS field Priority Setup
E -> Distrusted Port Setup

<< Press ESC key to return to Main Menu or enter a command >>

5.8.6.1.1 Priority Mode Setup

H > Switch Setup


F > QoS Setup
A > Class of Service Setup
A > Priority Mode Setup

The Priority Mode Setup screen will appear. Scroll in your settings. Press the Enter key.

Table 5-34 Priority Mode Setting Options


.
Field Setting Options Default Setting
WAN1 (GE) Tag/TOS, Fixed Tag/TOS
WAN2 to 9 (FE)
LAN1 (GE)
LAN2 to 9 (FE)
Packet Priority Tag, TOS Tag

Unit 3 ENETSW === Priority Mode Setup === 13:29:43 02/23/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

WAN1(GE) : Tag/TOS
WAN2(FE) : Tag/TOS
WAN3(FE) : Tag/TOS
WAN4(FE) : Tag/TOS
WAN5(FE) : Tag/TOS
WAN6(FE) : Tag/TOS
WAN7(FE) : Tag/TOS
WAN8(FE) : Tag/TOS
WAN9(FE) : Tag/TOS
LAN1(GE) : Tag/TOS
LAN2(FE) : Tag/TOS
LAN3(FE) : Tag/TOS
LAN4(FE) : Tag/TOS
LAN5(FE) : Tag/TOS
LAN6(FE) : Tag/TOS
LAN7(FE) : Tag/TOS
LAN8(FE) : Tag/TOS
LAN9(FE) : Tag/TOS
Packet Priority : Tag

<< Press ESC key to return to previous menu >>

Alstom Page 71
e-DXC Ethernet Card

5.8.6.1.2 Fixed Priority Setup

H > Switch Setup


F > QoS Setup
A > Class of Service Setup
B > Fixed Priority Setup

The Fixed Priority Setup screen will appear. Scroll in your settings. Press the Enter key.

Table 5-35 Fixed Priority Setting Options

Field Setting Options Default Setting


Transmission Priority P0, P1, P2, P3 P0
Drop Procedure low-drop, high-drop

Unit 3 ENETSW === Fixed Priority Setup === 13:30:20 02/23/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

Transmission priority Drop precedence


WAN1(GE) : P0 low-drop
WAN2(FE) : P0 low-drop
WAN3(FE) : P0 low-drop
WAN4(FE) : P0 low-drop
WAN5(FE) : P0 low-drop
WAN6(FE) : P0 low-drop
WAN7(FE) : P0 low-drop
WAN8(FE) : P0 low-drop
WAN9(FE) : P0 low-drop
LAN1(GE) : P0 low-drop
LAN2(FE) : P0 low-drop
LAN3(FE) : P0 low-drop
LAN4(FE) : P0 low-drop
LAN5(FE) : P0 low-drop
LAN6(FE) : P0 low-drop
LAN7(FE) : P0 low-drop
LAN8(FE) : P0 low-drop
LAN9(FE) : P0 low-drop

<< Press ESC key to return to previous menu >>

5.8.6.1.3 VLAN Tag Priority Setup

H > Switch Setup


F > QoS Setup
A > Class of Service Setup
C > VLAN Tag Priority Setup

The Vlan Tag Priority Setup screen will appear. Scroll in your settings. Press the Enter key.

Table 5-36 Vlan Tag Priority Setting Options

Field Setting Options Default Setting Notes


Tag Priiority Display only
Transmission Priority P0, P1, P2, P3 P0
Drop Procedure low-drop, high-drop

Unit 3 ENETSW === Vlan Tag Priority Setup === 13:30:59 02/23/2009
ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

Tag priority Transmission priority Drop precedence


0 P0 low-drop
1 P0 low-drop

Alstom Page 72
e-DXC Ethernet Card

2 P0 low-drop
3 P0 low-drop
4 P0 low-drop
5 P0 low-drop
6 P0 low-drop
7 P0 low-drop

<< Press ESC key to return to previous menu >>

5.8.6.1.4 TOS Field Priority Setup

H > Switch Setup


F > QoS Setup
A > Class of Service Setup
D > TOS Field Priority Setup

The TOS Field Priority Setup screen will appear. Scroll in your settings. Press the Enter key.

Table 5-37 TOS Field Priority Setting Options

Field Setting Options Default Setting Notes


Tag Priority Display only
Transmission Priority P0, P1, P2, P3 P0
Drop Procedure low-drop, high-drop
TOS Field [4:2] , [7:5] [4:2]

Unit 3 ENETSW === TOS field Priority Setup === 13:31:47 02/23/2009
ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

Tos priority Transmission priority Drop precedence


0 P0 low-drop
1 P0 low-drop
2 P0 low-drop
3 P0 low-drop
4 P0 low-drop
5 P0 low-drop
6 P0 low-drop
7 P0 low-drop

TOS field: [4:2]

<< Press ESC key to return to previous menu >>

Alstom Page 73
e-DXC Ethernet Card

5.8.6.1.5 Distrusted Port Setup

H > Switch Setup


F > QoS Setup
A > Class of Service Setup
E > Distrusted Port Setup

The Distrusted Port Setup screen will appear. Scroll in your settings. Press the Enter key.

Table 5-38 TOS Field Priority Setting Options

Field Setting Options Default Setting Notes


Port Display only
Distrusted distrusted, trusted trusted
New Tag Priiority 0, 1, 2, 3, 4, 5, 6, 7 0
(for distrusted port)

Unit 5 ENETSW === Distrusted Port Setup === 11:24:41 10/01/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT
Port Distrusted New Tag Priority(for distrusted port)
WAN1(GE) trusted 0
WAN2(FE) trusted 0
WAN3(FE) trusted 0
WAN4(FE) trusted 0
WAN5(FE) trusted 0
WAN6(FE) trusted 0
WAN7(FE) trusted 0
WAN8(FE) trusted 0
WAN9(FE) trusted 0
LAN1(GE) trusted 0
LAN2(FE) trusted 0
LAN3(FE) trusted 0
LAN4(FE) trusted 0
LAN5(FE) trusted 0
LAN6(FE) trusted 0
LAN7(FE) trusted 0
LAN8(FE) trusted 0
LAN9(FE) trusted 0

<< Press ESC key to return to previous menu >>

5.9.6.2. TCP/UDP Port Access Control

H > Switch Setup


F > QoS Setup
A > Class of Service Setup
B > TCP/UDP Port Access Control

Unit 3 ENETSW = TCP/UDP Port Access Control = 13:32:21 02/23/2009

A -> TCP/UDP Well Known Port Setup


B -> TCP/UDP User Define Port Setup
C -> TCP/UDP Port Range Setup

<< Press ESC key to return to Main Menu or enter a command >>

Alstom Page 74
e-DXC Ethernet Card

5.8.6.2.1 TCP/UDP Well Known Port Setup

H > Switch Setup


F > QoS Setup
B > TCP/UDP Port Access Control
A > TCP/UDP Well Known Port Setup

The Well Known Port Setup screen will appear. Scroll in your settings. Press the Enter key.

Table 5-39 TCP/UDP Well Known Port Setting Options

Field Setting Options Default Setting Notes


TCP/UDP Port Display only
Port Enable ENABLE, DISABLE DISABLE
Priority (tx) P0, P1, P2, P3 P0
Precedence (drop) low-drop, high-drop low-drop
Discard ENABLE, DISABLE DISABLE

Unit 3 ENETSW === Well Known Port Setup === 13:32:34 02/23/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

TCP/UDP Port Port Enable Priority(tx) Precedence(drop) Discard


23 DISABLE P0 low-drop DISABLE
512 DISABLE P0 low-drop DISABLE
6000 DISABLE P0 low-drop DISABLE
443 DISABLE P0 low-drop DISABLE
111 DISABLE P0 low-drop DISABLE
22555 DISABLE P0 low-drop DISABLE
22 DISABLE P0 low-drop DISABLE
554 DISABLE P0 low-drop DISABLE

NOTE: P0=lowest priority

<< Press ESC key to return to previous menu >>

5.8.6.2.2 TCP/UDP User Define Port Setup


H > Switch Setup
F > QoS Setup
B > TCP/UDP Port Access Control
B > TCP/UDP User Define Port Setup

The User Define Port Setup screen will appear. Scroll in your settings. Press the Enter key.

Table 5-40 TCP/UDP User Define Port Setting Options

Field Setting Options Default Setting


TCP/UDP Port 1 to 65535 0000
Port Enable ENABLE, DISABLE DISABLE
Priority (tx) P0, P1, P2, P3 P0
Precedence (drop) low-drop, high-drop low-drop
Discard ENABLE, DISABLE DISABLE

Alstom Page 75
e-DXC Ethernet Card

Unit 3 ENETSW === User Define Port Setup === 13:33:23 02/23/2009
ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

TCP/UDP Port Port Enable Priority(tx) Precedence(drop) Discard


00000 DISABLE P0 low-drop DISABLE
00000 DISABLE P0 low-drop DISABLE
00000 DISABLE P0 low-drop DISABLE
00000 DISABLE P0 low-drop DISABLE
00000 DISABLE P0 low-drop DISABLE
00000 DISABLE P0 low-drop DISABLE
00000 DISABLE P0 low-drop DISABLE
00000 DISABLE P0 low-drop DISABLE

NOTE: P0=lowest priority

<< Press ESC key to return to previous menu >>

5.8.6.2.3 TCP/UDP Port Range Setup

H > Switch Setup


F > QoS Setup
B > TCP/UDP Port Access Control
C > TCP/UDP Port Range Setup

The Port Range Setup screen will appear. Key or scroll in your settings as required. Press the Enter key.

Table 5-41 Port Range Setting Options

Field Setting Options Default Setting


Port Num (Min) 1 to 65535 0000
Port Num (Max) 1 to 65535 0000
Tx Priority P0, P1, P2, P3 P0
Drop Precedence low-drop, high-drop low-drop
Fiterilg YES, NO NO

Unit 3 ENETSW === Port Range Setup === 13:34:07 02/23/2009


ARROW KEYS: CURSOR MOVE, Please Input: 1 to 65535, BACKSPACE to edit

Port Num(Min) : 00000


Port Num(Max) : 00000
Tx Priority : P0
Drop Precedence : low-drop
Filtering : NO

<< Press ESC key to return to previous menu >>

5.9.6.3. Transmission Scheduling


H > Switch Setup
F > QoS Setup
C > Transmission Scheduling

Unit 3 ENETSW === Transmission Scheduling === 13:34:39 02/23/2009

A -> Scheduling Algorithm


B -> WFQ Weight Setup

<< Press ESC key to return to Main Menu or enter a command >>

Alstom Page 76
e-DXC Ethernet Card

5.8.6.3.1 Scheduling Algorithm

H > Switch Setup


F > QoS Setup
C > Transmission Scheduling
A > Scheduling Algorithm

The Scheduling Algorithm screen will appear. Scroll in your settings. Press the Enter key.

Table 5-42 Scheduling Algorithm Setting Options

Setting Type Setting Options Default Setting


P0 queue SP (strict riority),
P1 queue WFQ (weighted fair
P2 queue queuing)
P3 queue

Unit 3 ENETSW === Scheduling Algorithm === 13:34:51 02/23/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

port P0 queue P1 queue P2 queue P3 queue


WAN1(GE) : SP SP SP SP
WAN2(FE) : SP SP SP SP
WAN3(FE) : SP SP SP SP
WAN4(FE) : SP SP SP SP
WAN5(FE) : SP SP SP SP
WAN6(FE) : SP SP SP SP
WAN7(FE) : SP SP SP SP
WAN8(FE) : SP SP SP SP
WAN9(FE) : SP SP SP SP
LAN1(GE) : SP SP SP SP
LAN2(FE) : SP SP SP SP
LAN3(FE) : SP SP SP SP
LAN4(FE) : SP SP SP SP
LAN5(FE) : SP SP SP SP
LAN6(FE) : SP SP SP SP
LAN7(FE) : SP SP SP SP
LAN8(FE) : SP SP SP SP
LAN9(FE) : SP SP SP SP

SP:Strict Priority, WFQ:Weighted Fair Queuing

<< Press ESC key to return to previous menu >>

5.8.6.3.2 WFQ Weight Setup

H > Switch Setup


F > QoS Setup
C > Transmission Scheduling
B > WFQ Weight Setup

The WFQ Weight Setup screen will appear. Scroll in your settings. Press the Enter key.

Table 5-43 WFQ Weight Setup Setting Options

Setting Type Setting Options Default Setting


P0 queue 0 to 100 25
P1 queue 25
P2 queue 25
P3 queue 25

Alstom Page 77
e-DXC Ethernet Card

Unit 3 ENETSW === WFQ Weight Setup === 13:35:22 02/23/2009


ARROW KEYS: CURSOR MOVE, Please Input: 0 to 100, BACKSPACE to edit

port P0 queue P1 queue P2 queue P3 queue


WAN1(GE) : 025% 025% 025% 025%
WAN2(FE) : 025% 025% 025% 025%
WAN3(FE) : 025% 025% 025% 025%
WAN4(FE) : 025% 025% 025% 025%
WAN5(FE) : 025% 025% 025% 025%
WAN6(FE) : 025% 025% 025% 025%
WAN7(FE) : 025% 025% 025% 025%
WAN8(FE) : 025% 025% 025% 025%
WAN9(FE) : 025% 025% 025% 025%
LAN1(GE) : 025% 025% 025% 025%
LAN2(FE) : 025% 025% 025% 025%
LAN3(FE) : 025% 025% 025% 025%
LAN4(FE) : 025% 025% 025% 025%
LAN5(FE) : 025% 025% 025% 025%
LAN6(FE) : 025% 025% 025% 025%
LAN7(FE) : 025% 025% 025% 025%
LAN8(FE) : 025% 025% 025% 025%
LAN9(FE) : 025% 025% 025% 025%

<< Press ESC key to return to previous menu >>

5.9.6.4. Transmission WRED Setup

The Unit Menu path for Transmission WRED Setup is as follows:

H > Switch Setup


F > QoS Setup
D > Transmission WRED Setup

The Transmission WRED Setup screen will appear. Key in your settings. Press the Enter key.

Table 5-44 Transmission WRED Setting Options


Field Setting Options Default Setting
X% 0 to 15 12
Y% 0 to 15 0
Z% 0 to 15 0
Level1 0 to 2000 0032
Level2 0 to 2000 0064

Unit 1 ENETSW === Transmission WRED Setup === 12:35:54 10/01/2009


ARROW KEYS: CURSOR MOVE, Please Input: 0 to 15, BACKSPACE to edit

X% : 12(x6.25%)
Y% : 00(x6.25%)
Z% : 00(x6.25%)
Level1 : 0032
Level2 : 0064

Level1 : When destination queue size reaches Level1 threshold,


the high-drop packets will be dropped at X%,
the low-drop packets will be dropped at Y%.
Level2 : When destination queue size reaches Level2 threshold,
the high-drop packets will be dropped at 100%,
the low-drop packets will be dropped at Z%.

<< Press ESC key to return to previous menu >>

Alstom Page 78
e-DXC Ethernet Card

5.9.6.5. Rate Control Setup

The Unit Menu path for Rate Control Setup is as follows:

H > Switch Setup


F > QoS Setup
E > Rate Control Setup

The Rate Control Setup screen will appear. Press A or B.

Unit 1 ENETSW === Rate Control Setup === 13:03:54 10/01/2009

A ->Rate Ctrl/Ingress WRED Setup


B ->Port Bitrate Setup

<< Press ESC key to return to Main Menu or enter a command >>

5.8.6.5.1 Rate Ctrl/Ingress WRED Setup

The Unit Menu path for Rate Ctrl/Ingress WRED Setup is as follows:

H > Switch Setup


F > QoS Setup
E > Rate Control Setup
A > Rate Ctrl/Ingress WRED Setup

The Rate Ctrl/Ingress WRED Setup screen will appear. Key or scroll in your settings as required. Press the
Enter key.
Table 5-45 Rate Ctrl/Ingress WRED Setting Options

Field Setting Options Default Setting


Egress Rate Control ENABLE, DISABLE DISABLE
Ingress Rate Control ENABLE, DISABLE DISABLE
Ra% (granularity 6.25%): 00 0 to 15 0
Rb% (granularity 6.25%): 00 0 to 15 0

Unit 1 ENETSW === Rate Ctrl/Ingress WRED Setup === 13:13:30 10/01/2009
ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

[Rate control for egress/ingress]


Egress Rate Control: DISABLE
Ingress Rate Control: DISABLE

[Drop percentage for ingress WRED]


Ra%(granularity 6.25%): 00
Rb%(granularity 6.25%): 00

<< Press ESC key to return to previous menu >>

Alstom Page 79
e-DXC Ethernet Card

5.8.6.5.2 Port Bitrate Setup

The Unit Menu path for Port Bitrate Setup is as follows:

H > Switch Setup


F > QoS Setup
E > Rate Control Setup
B > Port Bitrate Setup

The Port Bitrate Setup screen will appear. Key or scroll in your settings as required. Press the Enter key.

Table 5-46 Port Bitrate Setting Options

Field Setting Options Default Setting


Egress rate multiple 0 to 1600 0160
Egress rate gran 64k, 640k 640k
Ingress rate multiple 0 to 1600 0160
Ingress rate gran 64k, 640k 640k

Unit 1 ENETSW === Port Bitrate Setup === 13:17:24 10/01/2009


ARROW KEYS: CURSOR MOVE, Please Input: 0 to 1600, BACKSPACE to edit
port Egress rate Ingress rate
=multiple*gran =multiple*gran

WAN2(FE) : 0160 x 640k 0160 x 640k


WAN3(FE) : 0160 x 640k 0160 x 640k
WAN4(FE) : 0160 x 640k 0160 x 640k
WAN5(FE) : 0160 x 640k 0160 x 640k
WAN6(FE) : 0160 x 640k 0160 x 640k
WAN7(FE) : 0160 x 640k 0160 x 640k
WAN8(FE) : 0160 x 640k 0160 x 640k
WAN9(FE) : 0160 x 640k 0160 x 640k

LAN2(FE) : 0160 x 640k 0160 x 640k


LAN3(FE) : 0160 x 640k 0160 x 640k
LAN4(FE) : 0160 x 640k 0160 x 640k
LAN5(FE) : 0160 x 640k 0160 x 640k
LAN6(FE) : 0160 x 640k 0160 x 640k
LAN7(FE) : 0160 x 640k 0160 x 640k
LAN8(FE) : 0160 x 640k 0160 x 640k
LAN9(FE) : 0160 x 640k 0160 x 640k

<< Press ESC key to return to previous menu >>

Alstom Page 80
e-DXC Ethernet Card

5.9.7. IGMP Setup

The Unit Menu path for IGMP Setup is as follows:

H > Switch Setup


G > IGMP Setup

The IGMP Setup screen will appear. Press A, B, C, D, E or F.

Unit 1 ENETSW === IGMP Setup === 13:20:53 10/01/2009

A -> IGMP Snooping


B -> IGMP Fast Leave
C -> IGMP Router Port
D -> IGMP IP Multicast Range
E -> IGMP Cross Vlan I
F -> IGMP Cross Vlan II

<< Press ESC key to return to Main Menu or enter a command >>

5.9.7.1. IGMP Snooping

The Unit Menu path for IGMP Snooping is as follows:

H > Switch Setup


G > IGMP Setup
A > IGMP Snooping

The IGMP Snooping screen will appear. Key or scroll in your settings as required. Press the Enter key.

Table 5-47 IGMP Snooping Setting Options

Field Setting Options Default Setting


IGMP Snooping ON, OFF OFF
Last Query Interval 0 to 65535 0100

Unit 1 ENETSW === IGMP Snooping === 13:42:26 10/01/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

IGMP Snooping : OFF


Last Query Interval : 00100 (milli-seconds)

<< Press ESC key to return to previous menu >>

Alstom Page 81
e-DXC Ethernet Card

5.9.7.2. IGMP Fast Leave

The Unit Menu path for IGMP Fast Leave is as follows:

H > Switch Setup


G > IGMP Setup
B > IGMP Fast Leave

The IGMP Fast Leave screen will appear. Key or scroll in your settings as required. Press the Enter key.

Table 5-48 IGMP Fast Leave Setting Options

Field Setting Options Default Setting


VID# 1 to 4094 1
Vid IGMP Fast Leave ON, OFF OFF

Unit 1 ENETSW === IGMP Fast Leave === 13:43:11 10/01/2009


ARROW KEYS: CURSOR MOVE, Please Input: 1 to 4094, BACKSPACE to edit
VID# : 0001

<< Press ESC key to return to previous menu >>

Alstom Page 82
e-DXC Ethernet Card

5.9.7.3. IGMP Router Port


The Unit Menu path for IGMP Router Port is as follows:

H > Switch Setup


G > IGMP Setup
C > IGMP Router Port

The IGMP Router Port screen will appear. Scroll in your settings. Press the Enter key.

Table 5-49 IGMP Router Port Setting Options

Setting Type Setting Options Default Setting


Router Port YES, NO NO

Unit 1 ENETSW === IGMP Router Port === 13:43:42 10/01/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT
Router Port
WAN1(GE) : No
WAN2(FE) : No
WAN3(FE) : No
WAN4(FE) : No
WAN5(FE) : No
WAN6(FE) : No
WAN7(FE) : No
WAN8(FE) : No
WAN9(FE) : No
LAN1(GE) : No
LAN2(FE) : No
LAN3(FE) : No
LAN4(FE) : No
LAN5(FE) : No
LAN6(FE) : No
LAN7(FE) : No
LAN8(FE) : No
LAN9(FE) : No

<< Press ESC key to return to previous menu >>

Alstom Page 83
e-DXC Ethernet Card

5.9.7.4. IP Multicast Range


The Unit Menu path for IGMP Multicast Range is as follows:

H > Switch Setup


G > IGMP Setup
D > IGMP Multicast Range

The IGMP Multicast Range screen will appear. Key or scroll in your settings as required. Press the Enter
key.

Table 5-50 IGMP Multicast Range Setting Options

Setting Type Setting Options Default Setting Notes


MC IP - start 0.0.0.0 Key in IP address
MC IP - endt 0.0.0.0 Key in IP address

Unit 1 ENETSW === IGMP IP Multicast Range === 13:44:13 10/01/2009


Please Input: 224.0.1.0 to 239.255.255.255, BACKSPACE to edit
MC IP - start MC IP - end
WAN1 000.000.000.000 000.000.000.000
WAN2 000.000.000.000 000.000.000.000
WAN3 000.000.000.000 000.000.000.000
WAN4 000.000.000.000 000.000.000.000
WAN5 000.000.000.000 000.000.000.000
WAN6 000.000.000.000 000.000.000.000
WAN7 000.000.000.000 000.000.000.000
WAN8 000.000.000.000 000.000.000.000
WAN9 000.000.000.000 000.000.000.000
LAN1 000.000.000.000 000.000.000.000
LAN2 000.000.000.000 000.000.000.000
LAN3 000.000.000.000 000.000.000.000
LAN4 000.000.000.000 000.000.000.000
LAN5 000.000.000.000 000.000.000.000
LAN6 000.000.000.000 000.000.000.000
LAN7 000.000.000.000 000.000.000.000
LAN8 000.000.000.000 000.000.000.000
LAN9 000.000.000.000 000.000.000.000
Only multicast IPs between 'start' and 'end' are acceptable for that port.

<< Press ESC key to return to previous menu >>

Alstom Page 84
e-DXC Ethernet Card

5.9.7.5. IGMP Cross Vlan I


The Unit Menu path for IGMP Cross Vlan I is as follows:

H > Switch Setup


G > IGMP Setup
E > IGMP Cross Vlan I

The IGMP Cross Vlan I screen will appear. Key or scroll in your settings as required. Press the Enter key.

Table 5-51 IGMP Cross Vlan I Setting Options

Field Setting Options Default Setting Notes


IGMP Cross Vlan ON, OFF OFF
IGMP Cross Vlan ID 1 to 4094 4000

Setting Types Setting Options Default Setting Notes


Multicast IP 0.0.0.0 Key in IP address
Wan 1 to 9 0, 1 0
Lan 1 to 9 0, 1 0

Unit 1 ENETSW === IGMP Cross Vlan I === 13:53:43 10/01/2009


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT
IGMP Cross Vlan : OFF
IGMP Cross VlanID : 4000
Multicast IP wan1 2 3 4 5 6 7 8 9 lan1 2 3 4 5 6 7 8 9
1 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
2 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
3 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
4 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
5 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
6 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
7 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
8 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
9 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
10 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
11 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
12 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
13 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
14 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
15 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
16 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

<< Press ESC key to return to previous menu >>

Alstom Page 85
e-DXC Ethernet Card

5.9.7.6. IGMP Cross Vlan II

The Unit Menu path for IGMP Cross Vlan II is as follows:

H > Switch Setup


G > IGMP Setup
F > IGMP Cross Vlan II

The IGMP Cross Vlan II screen will appear. Key or scroll in your settings as required. Press the Enter key.

Table 5-52 IGMP Cross Vlan II Setting Options

Field Setting Options Default Setting Notes


Multicast IP 0.0.0.0 Key in IP address
Wan 1 to 9 0, 1 0
Lan 1 to 9 0, 1 0

Unit 1 ENETSW === IGMP Cross Vlan II === 13:59:05 10/01/2009


Please Input: 224.0.1.0 to 239.255.255.255, BACKSPACE to edit

Multicast IP wan1 2 3 4 5 6 7 8 9 lan1 2 3 4 5 6 7 8 9


17 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
18 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
19 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
20 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
21 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
22 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
23 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
24 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
25 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
26 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
27 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
28 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
29 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
30 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
31 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
32 000.000.000.000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

<< Press ESC key to return to previous menu >>

Alstom Page 86
e-DXC Ethernet Card

5.9.8. MAC Learning Setup

The Unit Menu path for MAC Learning Setup is as follows:


H > Switch Setup
H > MAC Learning Setup

Table 5-53 MAC Learning Setup

Setting Type Setting Options Default Setting NOTES


MAC Learning Enable, disable Enable These setting options are only available in e-line
mode. MAC learning is always enabled in e-lan
and portmap mode. Attempts to disable MAC
learning in e-lan or portmap mode will not be
successful.

Unit 7 ENETSW === MAC Learning Setup === 14:06:17 01/11/2010


ARROW KEYS: CURSOR MOVE, ENTER KEY: ITEM SELECT

Switch MAC Learning in "e-line" Mode: ENABLE

Note: MAC learning is always enabled in "e-lan" and "portmap" mode.

<< Press ESC key to return to previous menu >>

Alstom Page 87
e-DXC Ethernet Card

5.10. SNCP/UPSR APS Setup

The Unit Menu path for SNCP/UPSR APS Setup is as follows:

D > SNCP/UPSR APS Setup

The following SNCP/UPSR APS Setup screen will appear. Press A or B.

Unit 5 ENETSW === SNCP/UPSR APS Setup === 10:29:41 10/05/2009

A -> SNCP/UPSR APS Command


B -> SNCP/UPSR Revertive Setup

<< Press ESC key to return to Main Menu or enter a command >>

5.10.1. SNCP/UPSR APS Command

The Unit Menu path for SNCP/UPSR APS Command is as follows:

D > SNCP/UPSR APS Setup


A > SNCP/UPSR APS Command

The SNCP/UPSR APS Command screen will appear. Use the arrow keys to move the cursor. Key in the
Port number. Scroll in the Channel #. Press the Enter key.

Unit 5 ENETSW === SNCP/UPSR APS Command === 10:34:22 10/05/2009


ARROW KEYS: CURSOR MOVE, Please Input: 2 to 9, BACKSPACE to edit
Select path ==>

Port : 2_
Channel : 01

<< Press ESC key to return to previous menu >>

An expanded screen will appear. Scroll in your Command setting. Press the Enter key. A prompt will ask if
you are sure. Press Y for yes.

SNCP/UPSR APS Command Setting Options


Fields Settings Default Setting Notes
Port 1 to 9 2 1GE -> 1, 8FE -> 2 to 9
Channel 1 to 63 1
Command Clear, Clear FS = Force Switch
FS, MS, MS = Manual Switch
PRI, SEC PRI = Primary
SEC = Secondary

Alstom Page 88
e-DXC Ethernet Card

Unit 5 ENETSW === SNCP/UPSR APS Command === 10:41:55 10/05/2009


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

Port : 2
Channel : 01

Command : Clear

Note :
FS = Force Switch
MS = Manual Switch
PRI = Primary
SEC = Secondary

<< Press ESC key to return to previous menu >>

5.10.2. SNCP/UPSR Revertive Setup

The Unit Menu path for SNCP/UPSR Revertive Setup is as follows:

D > SNCP/UPSR APS Setup


B > SNCP/UPSR Revertive Setup

The SNCP/UPSR Revertive Setup screen will appear. Use the arrow keys to move the cursor. Key in the
Port number. Scroll in the Channel #. Use the Tab key to scroll in the Command setting. Press the Enter
key.

Unit 5 ENETSW === SNCP/UPSR Revertive Setup === 10:55:48 10/05/2009


ARROW KEYS: CURSOR MOVE, Please Input: 2 to 9, BACKSPACE to edit
Select path ==>

Port : 2_
Channel : 01

<< Press ESC key to return to previous menu >>

An expanded screen will appear. Scroll in your Command setting. (See SNCP/UPSR APS Command
Setting Options in table above.) Press the Enter key. A prompt will ask if you are sure. Press Y for yes

Alstom Page 89
e-DXC Ethernet Card

5.11. Reset Unit

The Unit Menu path for Reset Unit is as follows:


Z > Reset Unit

Use the arrow keys to move the flashing cursor to either Working, Standby or Both. Press the Enter key.

Unit 1 ENETSW === Unit Reset === 14:21:51 01/07/2008

>>Unit? *Working Standby Both

The following prompt will appear. Press Y for Yes

Reset - are you sure ? [Y/N]

Key in your password. Press the Enter key.

>>Password:

The Unit Reset screen will appear. Use the arrow keys to move the flashing cursor to either Warm-reset or
Cold-Reset. Press the Enter key.

Unit 1 ENETSW === Unit Reset === 14:17:47 01/07/2008

>>Type? *Warm-Reset Cold-Reset

Use the arrow keys to move the flashing cursor to either Working, Standby or Both. Press the Enter key.

Unit 1 ENETSW === Unit Reset === 14:21:51 01/07/2008

>>Type? *Warm-Reset Cold-Reset

>>Unit? *Working Standby Both

5.12. Unit Load Default

The Unit Menu path for Unit Load Default is as follows:

W > Unit Load Default

A prompt will ask if you want to load the default configuration. Press Y for Yes.

Load default - are you sure (Y/N)?

Key in your password. Press the Enter key.

==>> Enter password :

Alstom Page 90
e-DXC Ethernet Card

6. Application: ELAN Ring


6.1. Introduction

This chapter introduces a common application for this card, which is setting up a ring topology using Ethernet
links. ELAN, or short for Ethernet Local Area Network, is the name we will use for this application.

NOTE: This application is only for the Ethernet card with the L2 Switch. Only FE (fast Ethernet) of 10/100
speeds are supported.
Ethernet Card
with L2 Switch

10/100
Ethernet e-DXC

Although physically connected as a ring, logically it is viewed as a tree or a linear topology. This allows it to
maintain the simple broadcast functionality common to LAN networks without incurring loops. To maintain
this functionality, MSTP (multiple spanning tree protocol) is used.

Normal State Emergency State

e-DXC

Blocked Port is
Port unblocked

Link Link is
Breaks Enabled

Alstom Page 91
e-DXC Ethernet Card

6.2. Setup Instructions

1) First, connect a VT-100 monitor (a PC running VT-100 emulator software) to the rack controller and
login to the system.

DB9 Cable

PC with VT-100
e-DXC Emulation Software

2) From the controller main menu, go to U > Choose a Trib Unit and enter the slot number for the
Ethernet card that is part of the ring. In this example, the Ethernet card is in the first slot.

e-DXC === Controller Menu === 17:36:00 04/24/2013

Serial Number : 000205 Device Name : DEVICE 1


Hardware Version: Ver.B Start Time : 17:35:59 04/22/2013
Software Version: V2.06.01 (0004) Connect Port: SUPV_PORT
FPGA Version : V1

[DISPLAY] [SETUP]
C -> System Config Display S -> System Config Setup
D -> SDH/SONET Config Display H -> SDH/SONET Config Setup
I -> System Information M -> Alarm Setup
Q -> Alarm Queue L -> Security File Transfer
B -> Currently-Active Alarm Summary V -> Store/Retrieve Backup Config
A -> Current Alarm Status G -> Loopback/Diagnostics Setup
P -> SDH/SONET Performance R -> Performance Setup/Clear
T -> System Log N -> Unit Registration
E -> Diagnostics Display

[LOG] [MISC]
F -> Log Off Y -> Alarm Cut Off
O -> Log On Z -> Reset
U -> Choose a Trib Unit X -> Clear Alarm Queue
W -> Return to Default

==>> Press Tab key to select the unit: 1

Alstom Page 92
e-DXC Ethernet Card

3) Go to M -> Mode Setup and change the mode to "e-lan (8FE)"

Unit 1 ENETSW === Unit Menu === 17:36:38 04/24/2013

HW Version : E Card State : Initialization Completed


SW Version : V2.08.03 09/24/2012 TPSG Working :

[DISPLAY] [SETUP]
C -> WAN(VCG) & Link Display M -> Mode Setup
Q -> Currently-Active Alarm Summary S -> WAN(VCG) & Link Setup
A -> Current Alarm Status R -> Performance Setup/Clear
P -> Unit Performance L -> Security File Transfer
G -> WAN(VCG) Statistics H -> Switch Setup
I -> Switch Status D -> SNCP/UPSR APS Setup
B -> SNCP/UPSR APS Status

[LOG] [MISC]
F -> Log Off Z -> Unit Reset
O -> Log On W -> Unit Load Default
U -> Choose a Unit
E -> Return to Main Menu

>>SPACE bar to refresh or enter a command ===>

Unit 1 ENETSW === Mode Setup === 17:37:49 04/24/2013


ARROW KEYS : CURSOR MOVE , ENTER KEY : ITEM SELECT

Mode Selection : e-lan(8FE)

<< Press ESC key to return to previous menu >>

4) From the Ethernet card menu, go to H > Switch Setup, D > MSTP/RSTP Setup, and then A >
MSTP Region/CIST Setup. Enable MSTP on this switch. Change other settings as necessary.

Unit 1 ENETSW === MSTP Region/CIST Setup === 17:45:17 04/24/2013


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS

STP : MSTP enable

Region Name : MSTname


Revision : 00001

Bridge ID MAC ADDR : 00-60-58-2C-00-CE


Bridge ID Priority : 32768 (MST instance 0)
Bridge Max Age : 20 sec Hello Time : 02 sec Forward Delay : 15 sec

<< Press ESC key to return to previous menu >>

Alstom Page 93
e-DXC Ethernet Card

5) On the e-DXC controller menu, go to H > SDH/SONET Config Setup and then C > Cross Connect
Create Setup. Map Port 1 of the XCU1 to WAN2 of the Ethernet card. Make sure the granularity is
TU12 and the count is 21.

e-DXC === Cross Connect Create Setup === 17:48:25 04/24/2013


ARROW KEYS: CURSOR MOVE, TAB/`: ROLL UP/DOWN OPTIONS
Granularity : TU12
Xcon Type : Bi-Xc
Count : 21
-------------------------------- Source --------------------------------------
From Slot : XCU1(W) From AUG1 : 1
From Port : 1 From TS : 1 -VC3/TUG3 01 -VC1x
KLM : [ TUG3#1, TUG2#1, TU12#1 ]
-------------------------------- Destination ---------------------------------
To Slot : Trib-1
To WAN : 2 To TS : 01 -Channel

VC3/TUG3 VC1x : Source -> XCU1(W) Port#1 AUG1#1 Timeslot Available


#1 01~21 : o o o o o o o o o o o o o o o o o o o o o
#2 01~21 : o o o o o o o o o o o o o o o o o o o o o
#3 01~21 : o o o o o o o o o o o o o o o o o o o o o
ENET CHANNEL : Destination -> Trib-1 WAN#2 Timeslot Available(63)
#01~28 : o o o o o o o o o o o o o o o o o o o o o o o o o o o o
#29~56 : o o o o o o o o o o o o o o o o o o o o o o o o o o o o
#57~63 : o o o o o o o

>>Are you sure (Y/N)?

6) Repeat Step 5 for the second XCU card.

e-DXC === Cross Connect Create Setup === 17:48:25 04/24/2013


ARROW KEYS: CURSOR MOVE, Please Input: 2~9, BACKSPACE to edit
Granularity : TU12
Xcon Type : Bi-Xc
Count : 21
-------------------------------- Source --------------------------------------
From Slot : XCU2(E) From AUG1 : 1
From Port : 1 From TS : 1 -VC3/TUG3 01 -VC1x
KLM : [ TUG3#1, TUG2#1, TU12#1 ]
-------------------------------- Destination ---------------------------------
To Slot : Trib-1
To WAN : 3 To TS : 01 -Channel

VC3/TUG3 VC1x : Source -> XCU2(E) Port#1 AUG1#1 Timeslot Available


#1 01~21 : o o o o o o o o o o o o o o o o o o o o o
#2 01~21 : o o o o o o o o o o o o o o o o o o o o o
#3 01~21 : o o o o o o o o o o o o o o o o o o o o o
ENET CHANNEL : Destination -> Trib-1 WAN#3 Timeslot Available(63)
#01~28 : o o o o o o o o o o o o o o o o o o o o o o o o o o o o
#29~56 : o o o o o o o o o o o o o o o o o o o o o o o o o o o o
#57~63 : o o o o o o o

>>Are you sure (Y/N)?