Ordering number : ENN7340

Thick-Film Hybrid IC

STK402-950
Class AB Audio Power Amplifier IC
30 W × 5 Channels

Overview Package Dimensions


The STK402-900 series products are audio power unit: mm
amplifier hybrid ICs that consist of optimally-designed 4200-SIP24
discrete component power amplifier circuits that have
been miniaturized using SANYO's unique insulated metal [STK402-950]
substrate technology (IMST). The adoption of a newly-
developed low thermal resistance substrate allows this 78.0
product to integrate five power amplifier channels in a 70.0 8.5

single compact package.

Features 3.6

32.0
21.0
16.5

27.3
• Series of pin compatible power amplifiers ranging from
20 W/ch to 45 W/ch (10%/1 kHz) devices. The same 1 24
2.0 0.5 2.9
printed circuit board can be used depending on the

4.0
0.4
output power grade. (12.0) 23 × 2.0 = 46.0
5.5
• The pin arrangement is compatible with that of the 2-
channel STK403-000 series and 3-channel for STK403-
SANYO: SIP24
200 series.
• Miniature packages
— 15 W/ch to 45 W/ch (THD = 0.4%, f = 20 Hz to
20 kHz); 78.0 mm × 32.0 mm × 8.5 mm *
*: Not including the pins.
• Output load impedance: RL = 6 Ω
• Allowable load shorted time: 0.3 seconds
• Supports the use of standby, muting, and load shorting
protection circuits.

Any and all SANYO products described or contained herein do not have specifications that can handle
applications that require extremely high levels of reliability, such as life-support systems, aircraft’s
control systems, or other applications whose failure can be reasonably expected to result in serious
physical and/or material damage. Consult with your SANYO representative nearest you before using
any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other
parameters) listed in products specifications of any and all SANYO products described or contained
herein.

SANYO Electric Co.,Ltd. Semiconductor Company


TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
D1803TN (OT) No. 7340-1/5
STK402-950

Series Organization
These products are organized as a series based on their output capacity.
Type No.
Item
STK402-920 STK402-930 STK402-940 STK402-950
Output 1 (10%/1 kHz) 20 W × 5 ch 30 W × 5 ch 40 W × 5 ch 45 W × 5 ch
Output 2 (0.4%/20 Hz to 20 kHz) 15 W × 5 ch 20 W × 5 ch 25 W × 5 ch 30 W × 5 ch
Maximum supply voltage (No signal) ±30 V ±36 V ±38 V ±40 V
Maximum supply voltage (6 Ω) ±28 V ±34 V ±36 V ±38 V
Recommended supply voltage (6 Ω) ±20 V ±23 V ±26 V ±28 V
Package 78.0 mm × 32.0 mm × 8.5 mm

Specifications
Maximum Ratings at Ta = 25°C
Parameter Symbol Conditions Ratings Unit
Maximum supply voltage (No signal) VCC max(0) ±40 V
Maximum supply voltage VCC max(1) RL = 6 Ω ±38 V
Thermal resistance θ j -c Per power transistor 3.6 °C/W
Junction temperature Tj max 150 °C
Both the Tj max and the Tc max conditions must be met.
Operating IC substrate temperature Tc max 125 °C
Storage temperature Tstg –30 to +125 °C
Allowable load shorted time *4 ts VCC = ±28.0 V, RL = 6 Ω, f = 50 Hz, PO = 30 W 0.3 s

Operating Characteristics at Tc = 25°C, RL = 6 Ω (noninductive load), Rg = 600 Ω, VG = 30 dB

Conditions*1 Ratings
Parameter Symbol Unit
VCC (V) f (Hz) PO (W) THD (%) min typ max
PO (1) ±28.0 20 to 20 k 0.4 27 30
Output power *1 W
PO (2) ±28.0 1k 10 45
THD (1) ±28.0 20 to 20 k 1.0 0.4
Total harmonic distortion *1 %
THD (2) ±28.0 1k 5.0 0.01
Frequency characteristics *1 fL, fH ±28.0 1.0 +0 –3 dB 20 to 50 k Hz
Input impedance ri ±28.0 1k 1.0 55 kΩ
Output noise voltage *3 VNO ±34.0 Rg = 2.2 kΩ 1.2 mVrms
Quiescent current ICCO ±34.0 70 95 120 mA
Neutral voltage VN ±34.0 –70 0 +70 mV

Notes: 1. 1 ch drive
2. Unless otherwise noted, use a constant-voltage supply for the power supply used during inspection.
3. The output noise voltage values shown are peak values read with a VTVM. However, an AC stabilized (50 Hz) power supply should be used to
minimize the influence of AC primary side flicker noise on the reading.
4. Use the transformer power supply circuit shown in the figure below for allowable load shorted time measurement and output noise voltage
measurement.

DBA30C 4700µF
+VCC
+
500Ω

+
500Ω
--VCC
4700µF

Designated Transformer Power Supply (RP-25 equivalent)

No. 7340-2/5
STK402-950

Internal Equivalent Circuit

10
TR17 TR27 TR37
13
R11 R21 R31
TR14 TR24 TR34
R17 R27 R37
16
C11 C21 C31 23
TR15 TR25 TR35
R13 R23 R33
17 TR18 TR28 TR38
TR11 TR12 R14 R24 TR22 TR21 TR31 TR32 R34
18
R15 R25 R35
9 TR13 TR23 TR33
TR16 TR26 TR36
R12 D1 R16 R26 R22 R32 R36

11 22

21

12 20

19
6

5
14
R42 R46 R56 R52
SUB
R45 TR46 TR56 R55
8 TR43 TR48 TR58 TR53

4 2
TR41 TR42 R44 R54 TR52 TR51
3 1
R43 TR45 TR55 R53
C41 C51
TR47 TR57
TR44 TR54
R47 R57 15
R41 R51
24

ITF02195

Sample Application Circuit

STK402-900series

SUB

ch5 ch5 ch4 ch4 ch4 ch5 ch1 ch2 +Pre SUB (-Pre) ch1 ch1 ch2 ch2 ch3 ch3 ch3 -Pre
IN NF IN NF OUT OUT +VCC -VCC -VCC +VCC OUT OUT VCC GND (VCC) IN NF BIAS NF IN IN NF OUT VCC
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
10kΩ

220pF 220pF 220pF 220pF 220pF

1kΩ 2.2µF
+
33µF 1.8kΩ

33µF 1.8kΩ

33µF 1.8kΩ

33µF 1.8kΩ

33µF 1.8kΩ

ch5 IN
56kΩ
470pF

56kΩ

+ + 100Ω + + +
+ 2.2µF 1kΩ
0.1µF
100µF

3pF
56kΩ + ch3 IN
1kΩ 2.2µF 56kΩ 56kΩ
+
470pF
56kΩ

ch4 IN
3pF 56kΩ
470pF

56kΩ

3pF 3pF 2.2µF 1kΩ


100Ω ch2 IN
3pF +
470pF
56kΩ
100µF

0.1µF

+
470µF

2.2µF 1kΩ
+ + ch1 IN
470µF

470pF
56kΩ

+
1µF

1µF
4.7Ω

4.7Ω

4.7Ω

4.7Ω

4.7Ω
3µH

3µH

3µH

3µH

3µH
0.1µF

0.1µF

0.1µF

0.1µF

0.1µF
4.7Ω

4.7Ω

4.7Ω

4.7Ω

4.7Ω

ch4 OUT ch5 OUT +VCC -VCC ch1 OUT ch2 OUT ch3 OUT ITF02196

No. 7340-3/5
STK402-950

Thermal Design Example

The heat sink thermal resistance, θc-a, required to handle the total power dissipated within this hybrid IC is determined as
follows.
Condition 1: The IC substrate temperature Tc must not exceed 125°C.
Pd × θc-a + Ta < 125°C ... (1)
Ta: Guaranteed ambient temperature for the end product.
Condition 2: The junction temperature of each individual transistor must not exceed 150°C.
Pd × θc-a + Pd/N × θj-c + Ta < 150°C ... (2)
N: Number of power transistors
θj-c: Thermal resistance per power transistor
We take the power dissipation in the power transistors to be Pd evenly distributed across those N power transistors.
If we solve for θc-a in equations (1) and (2), we get the following inequalities.
θc-a < (125 – Ta)/Pd ... (1)’
θc-a < (150 – Ta)/Pd – θj-c/N ... (2)’
Values that satisfy both these inequalities at the same time are the required heat sink thermal resistance values.
Determining the following specifications allows us to determine the required heat sink thermal resistance from
inequalities (1)’ and (2)’.
• Supply voltage: VCC
• Load resistance: RL
• Guaranteed ambient temperature: Ta

Example:
Assume that the IC supply voltage, VCC, is ±28 V, RL is 6 Ω, and that the signal is a continuous sine wave. In this case,
from the Pd – PO characteristics, the maximum power will be 135 W for a signal with a frequency of 1 kHz.
For actual music signals, it is usual to use a Pd of 1/8 of POmax, which is the power estimated for continuous signals in
this manner. (Note that depending on the particular safety standard used, a value somewhat different from the value of
1/8 used here may be used.)
That is:
Pd = 85 W (when 1/8 POmax is 3.8 W)
The number, N, of power transistors in the hybrid IC's audio amplifier block is 10. Since the thermal resistance, θc-a, per
transistor is 3.6°C/W, the required heat sink thermal resistance, θc-a, for a guaranteed ambient temperature of 50°C will
be as follows.
From inequality (1)’: θc-a < (125 – 50)/85
< 0.88
From inequality (2)’: θc-a < (150 – 50)/85 – 3.6/10
< 0.81
Therefore, the thermal resistance that satisfies both these expressions at the same time is 0.81°C/W.
Note that this thermal design example assumes the use of a constant-voltage power supply, and is only provided as an
example for reference purposes. Thermal designs must be tested in an actual end product.

No. 7340-4/5
STK402-950

THD — PO Pd — PO
10 140
7 Tc = 25°C VCC = ±28 V
130
5 VCC = ±28 V RL = 6 Ω

Total device power dissipation, Pd — W


Total harmonic distortion, THD — %

3 120
VG = 30 dB f = 1 kHz
2
RL = 6 Ω 110 VG = 30 dB
1.0 Rg = 600 Ω 100 Rg = 600 Ω
7
5 1 ch drive 90 5 ch drive
3 80 (same output rating)
2 70
0.1 20 kHz 60
7
5 50
3 40
2 30
0.01 1 kHz 20
7
5 10
3 0
0.1 2 3 5 7 1.0 2 3 5 7 10 2 3 5 7 0.1 2 3 5 7 1.0 2 3 5 7 10 2 3 5 7
Output power, PO — W ITF02209 Output power, PO/ch — W ITF02210
PO — VCC PO — f
65 60
Tc = 25°C Tc = 25°C
60
f = 1 kHz VCC = ±26 V
55 VG = 30 dB VG = 30 dB
50 Rg = 600 Ω RL = 6 Ω
RL = 6 Ω Rg = 600 Ω THD = 10%
Output power, PO — W

45 Output power, PO — W
50 5 ch drive
40 10%
=
D .4%
=0
35
TH D
30
TH
25
40
20 THD = 0.4%
15
10
5
0 30
14 16 18 20 22 24 26 28 30 32 34 36 10 2 3 5 7 100 2 3 5 7 1k 2 3 5 7 10k 2 3
Supply voltage, ±VCC — V ITF02211 Frequency, f — Hz ITF02212

Specifications of any and all SANYO products described or contained herein stipulate the performance,
characteristics, and functions of the described products in the independent state, and are not guarantees
of the performance, characteristics, and functions of the described products as mounted in the customer’s
products or equipment. To verify symptoms and states that cannot be evaluated in an independent device,
the customer should always evaluate and test devices mounted in the customer’s products or equipment.
SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all
semiconductor products fail with some probability. It is possible that these probabilistic failures could
give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire,
or that could cause damage to other property. When designing equipment, adopt safety measures so
that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective
circuits and error prevention circuits for safe design, redundant design, and structural design.
In the event that any or all SANYO products (including technical data, services) described or contained
herein are controlled under any of applicable local export control laws and regulations, such products must
not be exported without obtaining the export license from the authorities concerned in accordance with the
above law.
No part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying and recording, or any information storage or retrieval system,
or otherwise, without the prior written permission of SANYO Electric Co., Ltd.
Any and all information described or contained herein are subject to change without notice due to
product/technology improvement, etc. When designing equipment, refer to the “Delivery Specification”
for the SANYO product that you intend to use.
Information (including circuit diagrams and circuit parameters) herein is for example only; it is not
guaranteed for volume production. SANYO believes information herein is accurate and reliable, but
no guarantees are made or implied regarding its use or any infringements of intellectual property rights
or other rights of third parties.

This catalog provides information as of December, 2003. Specifications and information herein are
subject to change without notice.

PS No. 7340-5/5

You might also like