You are on page 1of 2

MADE

catalogue IN
GERMANY
Belanja Cepat Cara Tepat

DIXION Patient Monitor


Storm 5900
This monitor is portable and compact. It offers high-performance monitoring
suitable for adults and children.

Features :
· Displaying up to 11 curves simultaneously
· 10.4" antiglare TFT multimode display (800 x 600)
· 5 - 7 Parameters (ECG, SpO2, Resp., NIBP, Temp., IBP, EtCO2)
· Built-in Li-ion battery
· Arrhythmia and S-T segment analysis
· 3-level audible and visible alarm capability
· Compatible with Dixion central monitoring system
· High storage capacity : 96 hour graphic and tabular trends of all parameters
· USB, Ethernet
· Thermal printer (option)
· VGA output, Wi-Fi (option)

GERMANY
Specification :
Parameters Slot
Features Description
ECG 3/5 leads
ECG curves 2 or 7 curves review
Gain selection x0.125; x0.25; x0.5; x1, x2, x4; auto
Sweep speed 6.25; 12.5; 25; 50 mm/s
S-T segment analysis Available
Arrhythmia analysis Available
Heart rate Measurement range : ± 15-300 bpm
Respiration Impedance between RA-LL (R-F)
Adults : ± 6-120 bpm
Measurement range
Pediatric/neonatal : ± 6-150 bpm
Apnea alarm Available
Apnea delay 10-40 seconds
Oscillometric
NIBP
Manual/automatic/continuous
Measurement types Systolic, diastolic, map
Adult : Sys : ± 40-270 mmHg
Dia : ± 10-215 mmHg
Map : ± 20-235 mmHg
Pediatric : Sys : ± 40-230 mmHg
Measurement range Dia : ± 10-180 mmHg
Map : ± 20-195 mmHg
Neonatal : Sys : ± 40-135 mmHg
Dia : ± 10-100 mmHg
Map : ± 20-110 mmHg
Temperature
Measurement range ± 0-50 °C
Channel 2-channel
SpO2 Measurement range : ± 20-100 %
Pulse Rate Measuring and Alarm Range : ± 30-300 bpm
IBP
Measurement range ± 0 - 300 mmHg Standard Accessories :
Channel 2-channel • SpO2 Adapter cable & SpO2 Sensor (Neonatal)
Pressure type ART, PAP, CVP, RAP, LAP, ICP, P1, P2
Capnometry EtCO2 Infrared absorption technique • SpO2 Sensor (Adult/Pediatric)
Measurement range ± 0-150 mmHg • NIBP Hose & Cuff (Adult, Pediatric & Neonatal)
Apnea alarm Available • ECG Cable trunk 5 lead & 3 lead, ECG Cable Wire
Calculation lnsCO2, AwRR (Adult/Pediatric & Neonatal) (Reusable)
Dimensions ± 320 x 150 x 265 mm
Weight ± 5 kg • Temperature cable
• Ground/Arde cable
Additional Accessories Standard Accessories

Additional Accessories is depending with Patient Monitor Series :


• IBP transducer interface cable & IBP Kit (Disposable)
• Module CO2 & Airway (Adult & Infant)

Parameters :
ECG Respiration NIBP Temperature SpO2 IBP EtCO2
Storm 5900-01 · · · · ·
Storm 5900-02 · · · · · ·
Storm 5900-04 · · · · · ·
Storm 5900-05 · · · · · · ·
± = Tolerance Measurement 10%