You are on page 1of 2

UCG35-12

12V 35AH
Deep Cycle Gel

UCG35-12 Physical Specification

Part Number UCG35-12

Length 195 ± 2 mm

Width 130 ± 2 mm

Container Height 159 ± 2 mm

Total Height (with terminal) 180 ± 2 mm

Approx Weight 11.2 kg

Specifications
Nominal Voltage 12V
Nominal Capacity (20HR) 35AH
Terminal Type Standard Terminal F5
Optional Terminal F6
Container Material Standard Option ABS
Flame Retardant Option (FR) -
Rated Capacity 20hr, 1.80V/cell, 25°C 36.4 AH/1.65A
10hr, 1.80V/cell, 25°C 35.0 AH/3.14A
5hr, 1.75V/cell, 25°C 28.1 AH/5.61A
1hr, 1.60V/cell, 25°C 19.8AH/19.8A
Max Discharge Current -
Internal Resistance Approx 0.01m
Discharge Characteristics Operating Temp. Range Discharge: -°C
Charge: -°C
Storage: -°C
Nominal Operating Temp. Range -
Cycle Use 14.4V ~ 15.0V Temp. Coefficient -mV/°C
Standby Use 13.6V ~ 13.8V Temp. Coefficient -mV/°C
Capacity affect by Temperature 40°C 103%
25°C 100%
0°C 86%
Design Floating Life at 20°C 12 Years
Self Discharge Ultracell batteries may be stored for up to 6 months at 25°C(77°F) and then a refresh charge is required.
For higher temperatures the time interval will be shorter.

Dimensions

F5 Terminal 16 [0.63] 39
] 7.5
0.0 6.5
[R
R1 6
159 mm
180 mm
16 [0.63]

6.2

6.5

6.5
[ 0.256]

195 mm 130 mm

Revised: 13 Aug 2014

1 Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: info@ultracell.co.uk
ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE

ISO9001
www.ultracell.co.uk
UCG35-12
12V 35AH
Deep Cycle Gel

Constant Current Discharge (Amperes) at 20°C

130.02 79.86 60.52 36.89 19.8 10.3 6.07 3.37 1.84


120.78 76.56 58.67 35.38 19.6 8.71 5.94 3.30 1.78
111.54 73.26 56.83 32.08 18.9 8.29 5.81 3.23 1.78
110.22 71.28 54.98 30.56 18.5 8.05 5.64 3.18 1.67
97.68 67.98 49.62 28.31 17.2 7.85 5.54 3.15 1.65
86.46 64.55 44.75 25.94 16.7 7.72 5.54 2.45 1.65

Constant Power Discharge (Watts) at 20°C

264 171.60 110 76.6 42.9 16.7 11.4 6.40 3.37


255.42 167.64 130.02 75.2 42.4 16.6 11.3 6.40 3.37
244.86 165 126.72 73.9 42 16.5 11.3 6.34 3.30
23.34 158.40 122.76 71.9 41.3 16.4 11.2 6.34 3.30
199.98 146.52 117.48 70 40 16.1 11.1 6.20 3.23
188.76 135.96 112.20 66.7 39.1 15.8 11.0 6.20 3.23

Discharge Characteristics Charging Characteristics


Temperature 250C CHARGE
VOLUME
CHARGING CHARGING
CURRENT VOLTAGE
13.0 % (A) (V/cell) 0.1CA-2.25V/cell Temperature(250C
120
12.0
2.4
Terminal Voltage(V)

100 0.1C CHARGED VOLUME


11.0
0.2C
0.05C
0.093C
80 0.08C 2.3 CHARGE VOLTAGE
0.4C (Constant 2.25v/cell)
10.0 0.6C

1C 60 0.06C 2.2
2C
AFTER 50% DISCHARGE
9.0
40 0.04C 2.1 AFTER 100% DISCHARGE

C=C20
8.0
C= C20 20 0.02C 2.0
CHARGING CURRENT

1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 0 0C
min H
0 4 8 12 16 20 24 28 32
Discharge Time Charging Time (hours)

Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life

110

100 14
Life expectancy(year)

90 12
Available capacity / %

Charging voltage
10 2.25V/cell
80

70
5
60
C20
50 C10 2
C5
40 C3
C1
30 0.5
-20 -15 -10 -5 0 5 10 15 20 25 30 20 30 40 50 O0 C
68 86 104 122 F
Battery temperature/ Battery temperature

Cycle Life in Relation to Depth of Discharge General Relation of Capacity VS. Storage Time
Residualaveragecapacity in % of C 20
Acc.t o IEC89 6-2 (25 0 C / 77 0F) 120
100

90
100
Extracted capacity in %

80
Available capacity %

70 80
60
10

50
60

40 30
40 20
40
30

20
20
10

400 800 120 0 160 0 200 0 240 0 280 0 320 0 360 0 400 0 0 5 10 15 20 25

Number of Cycles Storagetime in month

Revised: 13 Aug 2014

2 Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: info@ultracell.co.uk
ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE

www.ultracell.co.uk ISO9001