12V 35AH
Deep Cycle Gel
Length 195 ± 2 mm
Width 130 ± 2 mm
Specifications
Nominal Voltage 12V
Nominal Capacity (20HR) 35AH
Terminal Type Standard Terminal F5
Optional Terminal F6
Container Material Standard Option ABS
Flame Retardant Option (FR) -
Rated Capacity 20hr, 1.80V/cell, 25°C 36.4 AH/1.65A
10hr, 1.80V/cell, 25°C 35.0 AH/3.14A
5hr, 1.75V/cell, 25°C 28.1 AH/5.61A
1hr, 1.60V/cell, 25°C 19.8AH/19.8A
Max Discharge Current -
Internal Resistance Approx 0.01m
Discharge Characteristics Operating Temp. Range Discharge: -°C
Charge: -°C
Storage: -°C
Nominal Operating Temp. Range -
Cycle Use 14.4V ~ 15.0V Temp. Coefficient -mV/°C
Standby Use 13.6V ~ 13.8V Temp. Coefficient -mV/°C
Capacity affect by Temperature 40°C 103%
25°C 100%
0°C 86%
Design Floating Life at 20°C 12 Years
Self Discharge Ultracell batteries may be stored for up to 6 months at 25°C(77°F) and then a refresh charge is required.
For higher temperatures the time interval will be shorter.
Dimensions
F5 Terminal 16 [0.63] 39
] 7.5
0.0 6.5
[R
R1 6
159 mm
180 mm
16 [0.63]
6.2
6.5
6.5
[ 0.256]
195 mm 130 mm
1 Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: info@ultracell.co.uk
ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
ISO9001
www.ultracell.co.uk
UCG35-12
12V 35AH
Deep Cycle Gel
1C 60 0.06C 2.2
2C
AFTER 50% DISCHARGE
9.0
40 0.04C 2.1 AFTER 100% DISCHARGE
C=C20
8.0
C= C20 20 0.02C 2.0
CHARGING CURRENT
1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 0 0C
min H
0 4 8 12 16 20 24 28 32
Discharge Time Charging Time (hours)
Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life
110
100 14
Life expectancy(year)
90 12
Available capacity / %
Charging voltage
10 2.25V/cell
80
70
5
60
C20
50 C10 2
C5
40 C3
C1
30 0.5
-20 -15 -10 -5 0 5 10 15 20 25 30 20 30 40 50 O0 C
68 86 104 122 F
Battery temperature/ Battery temperature
Cycle Life in Relation to Depth of Discharge General Relation of Capacity VS. Storage Time
Residualaveragecapacity in % of C 20
Acc.t o IEC89 6-2 (25 0 C / 77 0F) 120
100
90
100
Extracted capacity in %
80
Available capacity %
70 80
60
10
50
60
40 30
40 20
40
30
20
20
10
400 800 120 0 160 0 200 0 240 0 280 0 320 0 360 0 400 0 0 5 10 15 20 25
2 Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: info@ultracell.co.uk
ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
www.ultracell.co.uk ISO9001