You are on page 1of 2

Hobart

PoWerMaster® 2300
45kVA to 90kVA Solid State Frequency Converter

Smaller & Lighter ~ More Efficient Design: Performance Features:


The Hobart PoWerMaster® 2300 converters flexible design • Compact and light weight
allows the Solid State Frequency Converter (SSFC) to be set up • Individual Phase Regulation
for either bridge, fixed, or trailer mount configurations. With our • Low noise levels < 65 dBA at 1 m
user-friendly controls and superior diagnostic system, the • 12-pulse input rectification
converter is easy to use and requires minimal training. • Output THD is < 2% for both linear & non-linear loads
• User-friendly controls for simple daily operation
Same great features as the ADV line plus higher efficiency, better • All user information available via digital display
input ITHD, provides 1.0 Power Factor support for B787 and A380 • Modular design throughout for easy access to all parts
aircraft and can automatically calibrate its LDC settings using • ETL (UL1012 and CSA) Certification
the optional Auto Calibration Plug. With a wide array of output • CE Compliant
ratings available, an optional 28.5 VDC output, and a broad • RS232 Communication Interface
choice of input voltage configurations, this unit has the versatility • JBUS or Siemens Protocol
to provide power to all aircraft from the smallest commuter aircraft • Simplified fault reporting troubleshooting and maintenance
to the larger narrow-body aircraft. State-of-the-art design, ease
of use, and proven reliability are among the many reasons the
PoWerMaster® 2300 design has set a new industry standard

HOBART is part of ITW GSE


– the world’s leading supplier of Ground Support Equipment

It’s all about connections


ITW GSE - HOBART
11001 US Highway 41 North
Palmetto, FL 34221
U.S.A.

Specifications
Phone (toll free in US): 800-899-1841
Phone (international): +1-941-721-1000
Fax: +1-941-721-1087
Email: hobartsales@itwgse.us
Web: www.itwgse.com
Hobart PoWerMaster® 2300 - 45kVA/60kVA/90kVA SE230

Input Electrical Environmental


Model Amperage @ Voltage Hertz
Characteristics • Operating Temperature:

213 August 2014


45SE230 103A @ 208 VAC 15% 50-60 5% • PF 0.7 lag-0.95 lead -40° F to +125° F (-40° C to +52° C)
4 54A @ 400 VAC 15% 50-60 5% • Voltage Regulation: < 0.5% for • Relative humidity: 10-100%
4 50A @ 460 VAC 15% 50-60 5% balanced and < 30% unbalanced loads non-condensing
4 36A @ 600 VAC 15% 50-60 5% • THD (total harmonic distortion): • Noise Level: <65 dbA @ 1m
60SE230 137A @ 208 VAC 15% 50-60 5% < 2% at linear and non linear loads
4 71A @ 400 VAC 15% 50-60 5% • Phase Displacement: Control / Indicators
4 65A @ 460 VAC 15% 50-60 5% 120° 1° for balanced load • 400 Hz. On/Off: each output
4 48A @ 600 VAC 15% 50-60 5%
120° 2° for 30% unbalanced load • Status LED
90SE230 107A @ 400 VAC 15% 50-60 5%
• Transient Performance: ∆V<8% • Common Error
4 98A @ 460 VAC 15% 50-60 5%
Recovery Time: <10ms after • Digital Display (default mode):
4 72A @ 600 VAC 15% 50-60 5%
100% load change Year / Month / Date
• Starting Current: <100% FLA • Meets/Exceeds MIL-STD-704F Hour / Minute Output Voltage Output
• Configuration: 3 wire plus ground • Crest Factor: 1.414 3% Current Output Frequency
• ITHD: 30kVA<13%, 45kVA<10%, 60/90kVA <7% • Voltage Modulation: < 1% • Alternate Display Modes
• Input Power Factor: >0.97 • Compensation - 0-12V (User Initiated)
• Overall Efficiency: Enclosure
45kVA >0.93 at 20-45 KVA load • NEMA 3R Options
60-90kVA >0.94 at 35-90 kVA load • Ventilation: Filtered forced air • Input: UL: 600VAC CE: 400 VAC
>0.90 at 25 kVA load • Internal disconnect with lock-out • Dual 400Hz outputs
• Standby Losses: <50 Watts capability • 28.5 VDC as 2nd output
• No Load Losses: <2kW • Emergency Stop Button • Bridge and Trailer Mounting kits
• Acid washed with zinc rich primer and • Remote Operator Station
Output anti-corrosive polyester powder topcoat • Lockable Door with Interlock
• 115/200 VAC, 3 Phase plus neutral • Standard color is RAL 7035 • TCP/IP Interface
• Continuous Power Rating: @0.8pf Maintenance • RS485 interface
45 kVA (36 kW): 130 amps • Min. preventive maintenance filters • Broken Neutral Detection
60 kVA (48 kW): 173 amps • MTTR: 20 minutes • Plug Insertion Interlock
90 kVA (72 kW): 260 amps • MTBF: 100,000 hours • Military E&F Interlock
• Service Tool
Overloads: Protections
• 45-90 kVA 100% 1.0 pf - 60 min. • Input: Contact factory for other available options.
• >100 to ≤ 125% - 600 sec. Over/Under-Voltage
• >125 to ≥ 150% - 60 sec. Phase Loss Dimensions & Weights
• >150 to ≤ 200% - 30 sec. • Output: • Vertical:
• >200 to ≤ 250% - 10 sec. Over/Under-Voltage 21.26” L x 24.6” W x 45.47” H (728 lbs)
• 250 to ≤ 300% - 1 sec. Over/Under-Frequency • Bridge Mount:
Overload (see output section) 43.3” L x 24.6” W x 27.2” H (728 lbs)
Frequency Short Circuit (L-L; L-N; L-G) • Trailer:
• 400 Hz ± 0.001% NBPT Capable 67.72” L x 37.4” W x 52” H (1,102 lbs)
• Frequency Modulation: • Physical: • Note:
0% (clock generated) Over Temperature Add 13.6” to length and 200 lbs to the
• Frequency Regulation: 0.001% Internal Voltage Error weight when the 28VDC or 600 VAC
• Frequency Drift: 0% (clock generated) Neutral Voltage Supervision options are added