GNG CONSULTANTS PTE. LTD.

CIVIL & STRUCTURAL CONSULTANTS


3791 Jalan Bukit Merah,#10-23,E-Centre@Redhill,Singapore 159471
Tel:+65-6274 0311 Fax:+65-6274 0310

ECM PRECAST WALL - STABILITY DESIGN


Project : BM58 - TANK 1

CONSIDER EARTH LATERAL LOAD + ECM PRECAST WALL SELFWEIGHT + FOOTING

USING PROP + CONCRETE BLOCK


B 2.3 (L) x 3.0 (H) x 0.2m thk ECM Precast Wall

BARRIER/NOISE BARRIER/NOISE
FOOTING FOOTING

550 1200 550

A
Diameter 50mm CHS @ max. 1.20m spacing

4x
2000 1.0 (L) x 1.0 (H) x 1.0 (D)m RC Concrete Block

1400 1400

500
M16 Anchor Bolt

2.3 (L) x 3.0 (H) x 0.2m thk ECM Precast Wall

ELEVATION VIEW VIEW A

BARRIER/NOISE
FOOTING

4x
1.0 (L) x 1.0 (H) x 1.0 (D)m RC Concrete Block

NOTE:
- ALL STEEL STRUCTURE NEED TO SPRAY
BY COLD GALVANIZING TO PREVENT
RUSH
- TO ENSURE THE STABILITY &
VERTICALITY OF PROP/PRECAST WALL AT
VIEW B Diameter 50mm CHS @ max. 1.20m spacing
ALL THE TIME
GNG CONSULTANTS PTE. LTD.
CIVIL & STRUCTURAL CONSULTANTS
3791 Jalan Bukit Merah,#10-23,E-Centre@Redhill,Singapore 159471
Tel:+65-6274 0311 Fax:+65-6274 0310

ECM PRECAST WALL - STABILITY DESIGN


Project : BM58 - TANK 1

CONSIDER EARTH LATERAL LOAD + ECM PRECAST WALL SELFWEIGHT + FOOTING

USING PROP ONLY


2.3 (L) x 3.0 (H) x 0.2m thk ECM Precast Wall

BARRIER/NOISE BARRIER/NOISE
FOOTING FOOTING

A
Diameter 50mm CHS @ max. 0.40m spacing
150 400 400 400 400 400 150

1400 1400

M16 Anchor Bolt

2.3 (L) x 3.0 (H) x 0.2m thk ECM Precast Wall

ELEVATION VIEW VIEW A

NOTE:
- ALL STEEL STRUCTURE NEED TO SPRAY
BY COLD GALVANIZING TO PREVENT
RUSH
- TO ENSURE THE STABILITY &
VERTICALITY OF PROP/PRECAST WALL AT
ALL THE TIME
GNG CONSULTANTS PTE. LTD.
CIVIL & STRUCTURAL CONSULTANTS
3791 Jalan Bukit Merah,#10-23,E-Centre@Redhill,Singapore 159471
Tel:+65-6274 0311 Fax:+65-6274 0310

ECM PRECAST WALL - STABILITY DESIGN


Project : BM58 - TANK 1

CONSIDER EARTH LATERAL LOAD + ECM PRECAST WALL SELFWEIGHT

USING PROP + CONCRETE BLOCK


2.3 (L) x 3.0 (H) x 0.2m thk ECM Precast Wall

A
Diameter 50 x 2.5mm thk CHS
550 1200 550

3x
1.0 (L) x 1.0 (H) x 1.0 (D)m RC Concrete Block

1400 1400

M16 Anchor Bolt

2.3 (L) x 3.0 (H) x 0.2m thk ECM Precast Wall

ELEVATION VIEW VIEW A

3x
1.0 (L) x 1.0 (H) x 1.0 (D)m RC Concrete Block

NOTE:
- ALL STEEL STRUCTURE NEED TO SPRAY
BY COLD GALVANIZING TO PREVENT
RUSH
- TO ENSURE THE STABILITY &
VERTICALITY OF PROP/PRECAST WALL AT
VIEW B Diameter 50mm CHS @ max. 1.20m spacing
ALL THE TIME
GNG CONSULTANTS PTE. LTD.
CIVIL & STRUCTURAL CONSULTANTS
3791 Jalan Bukit Merah,#10-23,E-Centre@Redhill,Singapore 159471
Tel:+65-6274 0311 Fax:+65-6274 0310

ECM PRECAST WALL - STABILITY DESIGN


Project : BM58 - TANK 1

CONSIDER EARTH LATERAL LOAD + ECM PRECAST WALL SELFWEIGHT

USING PROP ONLY


2.3 (L) x 3.0 (H) x 0.2m thk ECM Precast Wall

A
Diameter 50mm CHS @ max. 0.60m spacing
250 600 600 600 250

1400 1400

M16 Anchor Bolt

2.3 (L) x 3.0 (H) x 0.2m thk ECM Precast Wall

ELEVATION VIEW VIEW A

NOTE:
- ALL STEEL STRUCTURE NEED TO SPRAY
BY COLD GALVANIZING TO PREVENT
RUSH
- TO ENSURE THE STABILITY &
VERTICALITY OF PROP/PRECAST WALL AT
ALL THE TIME