You are on page 1of 16
GUIDED WAVE RADAR LEVEL TRANSMITTERS SPECIAL FEATURES APPLICATIONS * Adoptingadvanced microprocessor Solid /Liquid level measurement in industrial areas, especially * Unique echo processing technology for process industry like Petrochemical, Power Instauration, + Falseecho storage Chemical Plants, Water & Waste Water, Power Generation, + Internal temperature compensation Oil & Gas, * Narrow beam «Simple debugging and calibration r > SPECIFICATIONS : STANDARD VERSION : Application liquid and solid powder : Measuring Range : 30m Process Connection Thread, flange 5 Process Temperature : -40°C~#250°C : Process Pressure -0.1-2MPa Accuracy 13mm Frequency range : 100MHZ-1.8GHz : Explosion Proof ExialICT6Gb EnclosureProtection Grade 1 IRS? Single Output 4-20mA/HART (2- wire) L J KVRPWRD-31 Range 30m r >) SPECIFICATIONS STANDARD VERSION Application liquid Measuring Range : 6m Process Connection ‘Thread, flange Process Temperature 2 d0°C-#250°C Process Pressure -0.1-2MPa Accuracy 13mm Frequency range 100MHZ~1.8GHz Explosion Proof ExialICT6Gb Enclosure Protection Grade 1 R67 Single Output 4-20mA/ HART (2- wire) OO KVRPWRD-32 Range 6m GUIDED WAVE RADAR LEVEL TRANSMITTERS SPECIFICATIONS STANDARD VERSION Application Measuring Range Process Connection Process Temperature Process Pressure Accuracy Frequency range Explosion Proof Enclosure Protection Grade Single Output SPECIFICATIONS STANDARD VERSION Application Measuring Range Process Connection Process Temperature Process Pressure ‘Accuracy Frequency range Explosion Proof Enclosure Protection Grade Single Output QC Solid Powder 30m Thread, flange ~40°C-+250°C -0.1-2MPa 8mm 100MHZ-1.8GHz ExiallCT6Gb 1P67 4-20ma/HART(@- wire) u KVRPWRD-33 Range 6mm. liquid 6m Thread, flange -40"C-+400°C -0.1-40MPa : emma 23mm 100MHZ-1.8GHz ExiallCT6Gb P67 : 4-20mA/HARTQ-wire) L KVRPWRD-34 Range 6m GUIDED WAVE RADAR LEVEL TRANSMITTERS —————. SPECIFICATIONS STANDARD VERSION Application Corrosive Liquids Measuring Range A 6m (for rod probe)/ 20m (forcable probe) Process Connection Flange Process Temperature 40°C +120°C Process Pressure -0.1-2MPa Accuracy 2 43mm Frequency range 100MHZ~1.8GHz Explosion Proof : ExialICT6Gb Enclosure Protection Grade 1P67 [_ SingleOutput A-20mA/HART@-wire) KVRPWRD-35 Range 6m Cc >) SPECIFICATIONS STANDARD VERSION Application : Liquids with lower dielectric constant or liquids with wave surface Measuring Range Fl 6m Process Connection ‘Thread, flange Process Temperature 5 40°C 4250°C Process Pressure -0.1-40MPa Accuracy 43mm Frequency range 100MHZ-1.8GHz Explosion Proof ExialICT6Gb Enclosure Protection Grade : IP6? Single Output 4-20mA/HART (2- wire) KVRPWRD-36 L ) Range 6mm Calibration with programmer module (PWPM) PWPM is composed of 4 buttons and 1 LCD display, which can display the setting menu and parameters setting, DIMENSIONS Housing, Material: AL 1. A HART hand-hold communicator 2. Connected with a sensor 3. A resistance of 2500 GUIDED WAVE RADAR LEVEL TRANSMITTERS Kleev. DIMENSIONS ~ Oss KVRPWRD31 KVRPWRD32 cart | en Fastening Screws KVRPWRD33 KVRPWRD34 Fastening Screws Fastening Screws GUIDED WAVE RADAR LEVEL TRANSMITTERS DIMENSIONS KVRPWRD35 Flange Selection Table (GB/T9119-2000) ; Hole Center | Holes Hole Sealed No. Size OP | Distance | Quantityn | DiameterL | Surface d 1 DNSO 2165 125 4 18 9 2 NBO @200 160 a 18 132 3 DNi00 2220 180 8 18 156 4 DNi50 225 2240 8 2 2H 5 DN200 2340 2295 2 2 266 6 DN250 (2405 2355 2 2% 319 KGR GUIDED WAVE RADAR LEVEL TRANSMITTERS Kleev. TECHNICAL DATA, GENERAL PARAMETERS Working frequency: 100MHZ~1.8GHz Measuring range: 0-30m for cable probe; 0~6m for rod probe or coaxial probe; Repeatability: 2mm Resolution: Imm. Sample: echo sampling 55 times /s Responding time: >0.2s (depends on the application) Current signaloutput 4-20mA, Accuracy: #3mm. Communication: HART protocol Process connection: Thread, G1”A or G14"A. Flange, DN50, DN80, DN100, DN150, DN200, DN250 Process pressure: -0.1~ 2MPa Power supply: 24V DC (+/-10%), ripple voltage: 1Vpp Power consumption: Max.22.5mA_ Ambient temperature: -40 °C-+70 °C Explosion proof approval: Exia IC T6 Gb Enclosure protection grade: IP67 2-wire connection: input and signal output share one 2-wire shielded cable. Cable entry: M20*1.5 * 2 or 4"NPT*2 (cable diameter is 5~9mm) Measuring rang and the measuring range. ‘The following table shows the relationship between different mediums Medium| caren DK@e) Solid Particles Liquid Measuring Range 1 aie cold concentrate, | 3m (only for coaxial eg. N2CO2 probe) Tiquefied gas, eg White lime Propane 2 16-1.9 Specials Cement Solvent 20m Sugar Freon12/Freon Palm oil 3 19-2.5 Normal cement Mineral oil, fuel 20m Plaster Benzene, styrene, Grain, seeds aon 4 25-4 Stone tee, 25m Sand _ Naphthalene Chlorobenzene, Chloroform Moist stone, mineral 5 47 oes Cellulose spray 30m * Isocyan hydrochloric Acid. Aniline Metal powder Liquid with water 6 7 Carbon black Alcohol 30m Coal Liquid ammonia KGR usa GUIDED WAVE RADAR LEVEL TRANSMITTERS usa MODEL SELECTION KVRPWRD31 Transmitter model Probe type Max. measuring range Material KVRPWRD31 Cable probe 30,000mm. SS Explosion Proof P Standard type (non-explosion) I _Intrinsically safe (Ex ia IIC T6 Ga) D_Intrinsically safeand flame proof type (Exd ICTS Gb) Transmitter / Cable Probe A Liquid / 4mm B Solid/ (within 10m)/6mm c Sotid/(10-30m)/ 6mm. Process Connection/ Material G Thread GI4°A/SS GA Thread, GI”A/SS N Thread, 114’NPT/SS NA Thread, 1” NPT/SS Flange, DN50/PN16C D_ Flange, DN80/PNI6C E Flange, DN100/ PN16C F Flange, DN150/ PN16C H_— Flange, DN200/ PN16C K Flange, DN250/ PN16C Y__ Special design Seal / Temperature P Common seal/ (-40-+120)°C G_ Seal for high temperature/ (-40~+250)°C with radiation fins Electronic Unit 2 (4-20)mA/ 24V DC, 2-wire 3 (4-20)mA/ 24V DC, HART, 2-wire 4 (4-20)mA/ 24V DC, HART, 4-wire 5_(4-20)mA/ 220V AC, HART, 4-wire Housing / Enclosure Protection Grade L Aluminum/IP67 G_$S304/ 1P67 Cable Entry M_ M20x1.5 N "NPT Display / Programmer V With X_Without ‘Measuring Range (mm) GUIDED WAVE RADAR LEVEL TRANSMITTERS usa MODEL SELECTION KVRPWRD32 Transmitter model Probe type Max. measuring range Material KVRPWRD32 Cable probe 60,000mm. SS Explosion Proof Standard type (non-explosion) I _Intrinsically safe (Ex ia IIC T6 Ga) D_Intrinsically safeand flame proof type (Exd ICTS Gb) Rod Probe (diameter) A 6mm B 10mm Process Connection / Material G Thread GI4°A/SS GA Thread, GI”A/SS Thread, 1%4"NPT/S. Thread, 1” NPT/SS Flange, DN50/PN16C Flange, DN80/PN16C Flange, DN100/ PN16C Flange, DN150/ PN16C Flange, DN200/ PN16C Flange, DN250/ PNI6C Special design ‘Seal / Temperature P Common seal/ (-40-+120)°C G__ Seal for high temperature/ (-40-+250)°C with radiation fins Electronic Unit KAmmmUAZZ S 2 (4-20)mA/ 24V DC, 2-wire 3 (4-20)mA/ 24V DC, HART, 2-wire 4 (4-20)mA/ 24V DC, HART, 4-wire 5 _(4-20)mA/ 220V AC, HART, 4-wire Housing / Enclosure Protection Grade L Aluminum 1P67 G_$$304/ 167 Cable Entry M M20x15 N_Y"NPT Display / Programmer Vv With X__Without ‘Measuring Range (mm) GUIDED WAVE RADAR LEVEL TRANSMITTERS usa MODEL SELECTION KVRPWRD33 Transmitter model Probe type Max. measuring range Material KVRPWRD33_ 6mm twin cable probe 30,000mm. SS Explosion Proof P Standard type (non-explosion) 1 _ Intrinsically safe (Ex ia ITC T6 Ga) D_Intrinsically safe and flame proof type (Exd IC T6 Gb) Process Connection / Material D_ Flange, DN80/ PN16C E Flange, DN100/ PN16C F Flange, DN150/ PN16C HH Flange, DN200/ PN16C K Flange, DN250/ PN16C Y Special design ‘Seal / Temperature P Common sealf (-40-¥120)°C G _ Seal for high temperature/ (-40~+250)°C with radiation fins Electronic Unit 2 (4-20)mA/ 24V DC, 2-wire 3 (4-20)mA/ 24V DC, HART, 2-wire 4 (4-20)mA/ 24V DC, HART, 4-wire 5 _(4-20)mA/ 220V AC, HART, 4-wire Housing / Enclosure Protection Grade L Aluminum IP67 G_$.$304/1P67, Cable Entry M = M20x1.5 N "NPT Display / Programmer V With X_Without ‘Measuring Range (mm) GUIDED WAVE RADAR LEVEL TRANSMITTERS usa MODEL SELECTION KVRPWRD34 Transmitter model Probe type Max. measuring range Material KVRPWRD34 Rod probe 6000mm_ SS Explosion Proof P Standard type (non-explosion) 1 Intrinsically safe (Bx ia ITC T6 Ga) D_Intrinsically safe and flame proof type (Exd IC T6 Gb) Rod Probe (diameter) A 6mm B 10mm Process Connection / Material Thread GI4"A /SS Thread, 1¥4"NPT/ SS Flange, DN80/ PN16C/ SS 3041. Flange, DN100/ PN16C/S.S 304L Flange, DN150/ PN16C/S.S 304L. Flange, DN200/ PN16C/S.S 3041. Flange, DN250/ PNI6C/S.S 3041 Special design xAmAmoOZO Seal Temperature G__ Seal for high temperature/ (-40~+400)°C with radiation fins Electronic Unit 2 (4-20)mA/ 24V DC, 2-wire 3 (4-20)mA/ 24V DC, HART, 2-wire 4 (4-20)mA/ 24V DC, HART, 4-wire 5_(4-20)mA/ 220V AC, HART, 4-wire Housing / Enclosure Protection Grade TL. Aluminum/ 1P67 G_$5304/ 167 Cable Entry M M20x1.5 N_#"NPT Display / Programmer V With X_Without ‘Measuring Range (nm) GUIDED WAVE RADAR LEVEL TRANSMITTERS usa MODEL SELECTION KVRPWRD35 Transmitter model Probe type Max. measuring range Material KVRPWRD35 Corrosion proof probe (rod or cable) 6000/20,000mm_ SS Explosion Proof P Standard type (non-explosion) 1 Intrinsically safe (Bx ia ITC T6 Ga) D_Intrinsically safe and flame proof type (Exd IC T6 Gb) Rod Probe (diameter) A 6mm B 10mm Process Connection / Material Flange, DN50/ PN16C/S.S 3041. Flange, DN80/ PN16C/ S.S 3041. Flange, DN100/ PNI6C/S.S 304L Flange, DN150/PNI6C/$.5 3041. Flange, DN200/ PNI6C/S.S 3041. Flange, DN250/ PNI6C/S.S 304 Special design xnArAmUO ‘Seal / Temperature P Common seal/ (-40~+120) °C Electronic Unit (4-20)mA/ 24V DC, 2-wire (4-20)mA/ 24V DC, HART, 2-wire (4-20)mA/ 24V DC, HART, 4-wire (4-20)mA/ 220V AC, HART, 4-wire Housing / Enclosure Protection Grade L Aluminum/ 1P67 G_$S304/ 1P67 Cable Entry M = M20x1.5 N_#’NPT Display / Programmer V With X_Without Measuring Range (mm) GUIDED WAVE RADAR LEVEL TRANSMITTERS usa MODEL SELECTION KVRPWRD36 Transmitter model Probe type Max. measuring range Material KVRPWRD36 Coaxial tube probe 6,000mm_ SS Explosion Proof Standard type (non-explosion) I _Intrinsically safe (Ex ia IIC T6 Ga) D_Intrinsically safeand flame proof type (Exd ICTS Gb) Rod Probe (diameter) A 25mm B 50 mm (Match with flange with diameter above DN 80) Process Connection / Material GA Thread, GIA /SS NA Thread, 1” NPT/SS C Flange, DN50/ PN16C/ SS 3041 D__ Flange, DN80/ PN16C/S.S 304L E Flange, DN100/ PN16C/ SS 3041. F Flange, DN150/ PN16C/S.S 3041 H_ Flange, DN200/ PN16C/S.S 3041 K Flange, DN250/ PN16C/ S$ 3041. Y Special design ‘Seal / Temperature P Common seal/ (40-+120)°C G_ Seal for high temperature/ (-40~+250)°C with radiation fins Electronic Unit 2 (4-20)mA/ 24V DC, 2-wire 3 (4-20)mA/ 24V DC, HART, 2-wire 4 (4-20)mA/ 24V DC, HART, 4-wire 5_(4-20)mA/ 220V AC, HART, 4-wire Housing / Enclosure Protection Grade L Aluminum 1P67 G_$5304/ 1P67 Cable Entry M = M20x1.5 N "NPT Display / Programmer V With X_Without ‘Measuring Range (mm) GUIDED WAVE RADAR LEVEL TRANSMITTERS DATA SHEET FOR MODEL SELECTION CUSTOMER INFORMATION Company: Contact person: Address: Post code: ‘Telephone: Fax: Mobile phone: E-mail: Date: CERTIFICATE Gi Standard type (non-explosion proof) C2 Intrinsical C1 Intrinsically safe (Ex ib IIC T6 Gb) C1 Intrinsicallysafe + marine approval (Ex ib IC T6 Gb) C1 Intrinsicallysafe + flame proof Ex d ib IIC T6) ‘TANK/CONTAINER INFORMATION Tank type 1 Storage tank Reaction tank Cl Separation tank TANK STRUCTURE: 0 Tank material: © Tank pressure: TANK SIZE: Height of tank: m Diameter of tank: m Shape of tank top: DArch O Flat top CO Open Ily safe (Ex ib TIB'T5) CO Marine tank OC Conic KGR GUIDED WAVE RADAR LEVEL TRANSMITTERS Kleev. SHAPE OF TANK BOTTOM: Tapered O Flat Oi Inclined DArch INSTALLATION: CTopmounted 1 Side mounted Cl Bypass pipe mounted) Wave guide pipe mounted EXTENSION PIPE AT TANK TOP (IMPORTANT INFORMATION): Pipe Height: mm, Pipe Diameter: = mm MEASURING MEDIUM Medium Name: Dliquid Solid ~~ OMix Medium Medium ‘Temperature: °C DIELECTRIC CONSTANT Adhesion. O Yes O No Stirring: 0 Yes O No PROCESS CONNECTION Thread: (O G1%4"D 1%4’NPT 0 G2"A 0 G1"A 0 1’NPT) Flange (DN= Cl Flange (ANSI= ) POWER SUPPLY: 0 24V DC 2-wire 0220V AC Output: 0 4-20mA OHART O PROFIBUS PA Display: 0 With displayand programmer (Without display and programme 833 Claude Laurel Dr, Apex, NC27523, USA ‘Telephone: +1(919)-924-0408 | Fax:+1(919)-267-3859 | Email:infowkleevusa.com | Website: www.kleevusa.com

You might also like