You are on page 1of 8
nee series eT Digital PID Controllers -Y900 ce AL. HBA MODBUS a = Crna) BEST CHOICE FOR PROCESS AND TEMPERATURE CONTROL Ne euneo ORC ie tm Ness OEM Ree eee eer eg Cee RT ener tic om Mae ors Meese amet esis Puen slime cis yes agente Ma) aaa er a ue uel Bicker eset ere a FY series not only provide the basic control output selections but also plus See Ronen ee een K cen Sr ARC EE Berea eaay gO) on Available in 5 sizes , the models and sizes are as below: FY400:48X48mm (DIN 1/16) FY600/800:48X96mm (DIN 1/8) FY700:72X72mm (DIN 3/16) FY900:96X96mm (DIN 1/4) Fy400 FY700 Fy800 C€ S\.approval & free power ‘modes got CE and UL approval DC 24Vis also avalable(optiona function) Heater Break Alarm (HBA) = Heater currant owing through CT ean be ‘displayed on controler. If heater current is less than HBA set valve, ALI willbe activated{ optional function) Autotuning (AT) Belece AT ‘Alter AT i te S [AT Function can calculate the optimze PID Value for your control system, without trying ‘and error manually Various Indication Lamps Real time monitor the status of output (QUTVOUT2) AT alarm(ALI/ALZ/AL3),manual ‘output(MAN) and program(PRO), AL High Accuracy Input with Abit AD resolution , 0.2% accuracy of FS. Builtin "AutoZero-AutoSpan" function keep good ‘accuracy. ‘Operate on any voltage from AC 85~2O5V at SOIGOHz. FY900 FY600 IP65 Proof é Co P85 dust & wator proof is avaiable {or a models(optional function), MODBUS Communcation FY series suport both MODBUS RTU and MODBUS ASCII protocol. ‘Communication between controler and HMI oF ‘other equipment is more corvenit(optional function), Auto/Manual mode BP ca Conveniently switched between autofmanual output made by clicking "AIM" key(except "FY400") Bar-Graph Ouput percent displayed on the bar-graph in 10 LEDs resolution(except "F¥400"), Data Lock Function ‘All parameters are seperated in 3 operation levels. Each parameter ean be hidden or locked to prevent ‘unauthorized changes, Features Diricia Xeno (aa — Input Remote SV — ree FY300 Input yee (0=20mA ,4~20mA 0-5V,0-10V.1>5V ,2~10V O-1V Communication Hi (RS485 Communication) MODBUS Protocol Puc Up to 31 contalers can be connected. emt Max length 1 200M, noole Votage pulse Relay pan ®@ (SSR arve) b> 5 way ¢ ,seannc ro 9 Motor Valve Control TOD cssnision Recorder Ea EEEE| eral ype ey outa ye (0~207mA 4~20mA (0°5V,,0-10V ,1~8V 2-10 0-1 Communication (TTL Communication) Up to 10 controllers can be connected Max length 1M (Masten) (Slave 1) (Slave 9) st si st 8 " ‘The SV value of Save conales wile remoted by master conte and reached to max vale athe apy rem, ED Program ‘There are 2 pattems by 8 segments can be used in rampisoak program. Patom@ 2 ‘There are 2 patioms can be linked together as 16 segments in ramplsoak program. Motor Valve Control F800 ‘Sensor Input fa as Heating and Cooling Control Fye00 ‘Sensor Input Deal PID (HeatingiCooing) oura (Cooling) oun (Heating) SCR/TRIAC Trigger =, 19/39 Zero Croes Control Matted: 12 oe erage Ante Sonal Features FY Series ake Control Method Fp PID+PUZZY # TL ovorr F onore tree Autotuning (AT) Pi Alona yy) Aumtning s ‘When eutotuning acts it wil make PY hunting 1-2 eyce tocalculate optimize PID value, To protect use’'s device FY seties controller can perform PV hunting below SV by setting AT bias value(ATVL) —— Easy Mounting ‘Without using any screws. Built in fuzzy logic suppress the overshoot due to SV changes or external disturbance. Limit Setting enn onan Bil in output init function. Use this function to get diferent gracient cutput ana set lit tor output a Saving Space FY Series Other Brands he GS Se @ FY Series are shorter than other brands, But with more functions, Alarm Types ‘Maximun with 3 sets of alarm. ‘Alarm types list ae below: Deviation Deviation High Alarm Deviation Low Alarm Deviation HighiLow Alarm ‘System System Failed Alarm System Normal Alarm Band Alarm pv Program PV High Alarm Program Run Alarm Pv Low Alarm rogram End Alarm ‘Segment End Alarm Delay Time Use this function ean avoid alarm acts fequently ‘or acts due to external disturbance, i em ‘ie Hold Funct Use this function can avoid alarm acts at startup ‘The alarm acton is suppressed at start-up untl PV centers the non-alarm range. Appearance Xe FY400 FY600 FY800 » AO Os FY400 ‘Ea FY600 le oe” Sea eB FY700 | ini 4 B — FY800 FY900 | eae Digital PID C a EES a 5 cs a eo a [oo a a a ‘a aaa ‘a sae fm pa) | é ea} 8 ta [=i eae] | =a] FY600/800 FY900 Tae = re =) en ha — a o|[™ em. a & FEE Two me fee 5 | l% Oo @ ol A Fy ner kot s od i a a ft soroee E = a 8 3 5 eg o @& @w Bo | cmt ou ie a an] a mo a a ese ga vs fs Specifications ear PicUaeKeenlen Mode! Fv400 Fy600 Fy700 Fy800 Fys00 Dimension 48x48mm ——96X48mm ——72XT2mm ——4BX96Mm_ ——_96XOBmm ‘Supply voltage ‘AC 85~268V , DCZ4V (Optional) Frequency 50/60HZ Power Consumption approx 3VA approx 4VA approx VA approx 4VA approx 4VA ‘Momory 'Non-volatle memory E'PROM Input ‘Accuracy 0.254FS , Sample time 250ms To K.J,R,S.B,E,N,T, WSReW26Re , PL2.U.L RID P7100, JPT100, JPTSO made 4-20mA,, O-20mA Votage de O-1V..O-5V, O~10V,, 1~5V, 2-10 ~10~10mV,, O-f0mV | 0-20mV , O~50mV , 10~S0mV DP Position 0000, 000.0, 00.00 , 0.000 (avaliable for mA or Voltage de input) ouput 1 Main control output SPSTtype SPDT type. SPOTtype.-=— SPOT type SPDT type 3A, 220V , electrical life: 100,000 times or more(under the rated load). Voltage Pulse For SSR dhive. ON:24V , OFF:0V , maximum load current 20mA, Rolay mage 4-20mA , 0-20mA Maximum load resistance:$60 0 Voltage de O-SV, D~10V.1~SV ,2~10V. Maximum load current:20mA, he SPSTtype SPDT type. SPSTtype-—« SPOT type SPDT type 3A, 220V , electrical fe: 100,000 times or more(under the rated load). Control algonthms PID, P, Pl, PD, ONIOFF(P=0) , FUZZY PID range P.0~200% , 10~3600 Secs , D:0~300 Secs a (Output terminals (control output, alarm ,ansmission) and Input terminals are solated separately Isolated resistance 19M Q or more between input terminals and case(ground) at DC S0OV 10M 0 or more between output terminals and caseground) at DC S00V easy 1000V AC for 1 minute between input terminals and case(ground) Dielectric strength 509 AC for 1 minute between oulpul terminals and ease(ground) Operating temperature 0~s0°C Humidity range 20-90% RH Weight F400 approx 150g ,FY6001700/800 approx 2259 ,FY900 approx 3003, Pvetmm PVtmm Pvstdmm ——PV7mm PVt4mm ican sv-7mm Sv7mm svtomm = SV¢7mm Sv:10mm ose veg —vsoo—=rvTaD =r RAMPISOAK 2 Pater wth 8 eager each ae ‘fe pare canoe ted pete a 18 segments we ouput2 Fh Se Raley ___SPSTHpe “SPST ype SPSTIype SPST pe SPTpe Votoge uso For SR dive, ON20V, OFF.OV, maximumload uen23mA, made fim. 0-20nA Masi oad restarc'S60 0 Voge do O-8V, O-10V Jn6V 2-10, Manu lad cen mA tum 2 Srstype SPOThpe SPOTIpe. SPOTHpe SPOT Ope ‘am 3 X—_SPSTYpe SPST Ype SPST ype SPST pe Doay Range of Heat Curet 00-868, Acie 1 Hear Break Am reed S807 (Ser Ga00-200) SE 100 Tamm da, 00-88) ‘a ley ALi Tiananiesbn Atle or PY or 6 tanarion mAde -20mA , O-20mA. Maximum load resistance:560 0 Voltage de O~5V,0~10V,1~5V,2~10V. Maximum load curren:20mA Remote SV input 4~20mA,0~20mA , O-SV, O~10V, 1-5, 2~10V are available Protocol : MODBUS RTU , MODBUS ASCII, TAIE Interface : RS232 , RS485, TTL Baudrate : 38400 , 19200 , 9600 , 4800 , 2400 bps. Data bits: 8, Start bit: 1 , Stop bt: 1 or 2, Odd or Even parity WaterProot/DustProot IP65 Communication Order Information faa Pra eXenae () Model & Suffix codes Model Outputt Output2- Alarm TRS RemoteSV Commu- Input Power Water/Dust nleation Type Proof Fao] — [fF 2 1 B 2 2] — fe] - N FY400 48x48mm 9 None 0 None: 0 None 0 None 0 None 0 None See input A AC 85~265V N None cen Se F100 Detar TS Na econ [Meccan eee Som Blocow Bll wes FY800 48x96mm 2 Voltage Pulse 2 Voltage Pulse 2 2Sets 2 0-20mA 2 0-20mA 2 RS485 FY900 96x86mm (SSR Drive) (SSR Drive) 3Sets 4 0-5V o-sv TTL (STANDARD) 3 4-20mA 4-20mA o~10V o-10V RS232_MODBUS' deutnm 1 0-20A 4 0-20mA 15V G5 BLRSHBS MODEL een eat os pov 2-10 Trenm BOO BOO Hea Taeconm se0snm 6 y-2y 18v Heae2 Dow Dav HBACALZsALS (RAMP/SOAK Fregremmetiey [il toScR zero cross cont! 39SCR zero cross contro! + [1B Block means optional functions with addtional charge setae aoa * HEA Hooter Break Asm (HEA mu ube AL ok la ly) 19SCR shag anc contol ‘30SCR phase anale control {© Combination of options and models © Avaiisbie xX Notavaatie Optons RAMPISOAK Output 4 sar PROGRAM sca x son Mot valve coral sare macnn OURU2 lame Alarms HOA TRS FEZ conmmesion SozH, Fra Oo x ° x x OO 0 x 0 0 90 ° ° Fre x x ° oO x 0 0000 0 ° ° FY O Oo xXx ° (08 IbGi HOM EON KON EOS IOs EG) ° ° Fre00 | O x x ° ON EG OM HOM HOm KON Ol HO) ° ° Fys00 °o Oo ° o 0 0 0000 0 ° ° “Remote SV function is not available if HBA Function has been specied. | Input type table a 100-2000 (3920) oo-o0% (820%) 3 0-500°C (1112-7) ome ietzmr) RB 08 O-oooNC EIDE) KE OF OmIz00NzIODD oo-2000%(9820%) —J2 88 co~smDO%S 752.0%) 908 o-ecO*CKITIZ- ovenorc 147297) JS 11 O-toonte (THD) BHR a008C RIOR) ontso0e 202%) Re 4 0-17808C 22164) AN2 TH 0~ 10m onteo0ec @ar2eF) S218 0-1769"C (8216%F) ANS T8 0~ 200 ‘o-t820°e (9908) pee aor e219 oore es 4 100-0 cts) Ne Movs ram 2 Ssovacore (207) 12H seemaeo 207) To 24 00-2005 (65207) z (0-200 °C (3652) W226 0-23205C (4208%) bel Som tare As #8 ose ase) reeoo1o 05T) U2 ae Seaerngre OT) U9 3 OOWODT LOT) orettson) la 8 ere arn) oo SieeeoOC OBST) Je 4 coeeUOE TROT) We 8 -we-amOr OO) +— dsercaoer) es a camer pe a eatin = is Shvanome 26s) oer 4 soesuuo (S207) Ono a werner e207) = an oberon) ors 61 Game) On oe CaN = fovesoio (00%) a Bt nenaare 0520") Irs 86 soBe ao ORO) Sorcery ies ot camera) wre eaten ip

You might also like