Professional Documents
Culture Documents
Env Pep 1610006 en
Env Pep 1610006 en
ENVPEP1610006_V1 10/2016
EENVPEP1610006_V1 - Product Environmental Profile - EasyPact D3N 3P contactor,9A,20V,50Hz,1NO
General information
Representative product EasyPact D3N 3P contactor,9A,20V,50Hz,1NO -LC1N0910M5N
An equipment to control the load by cutting the current quickly or connecting the main loop
Description of the product frequently. The working principle is using the electromagnetism generated from the electriferous
coil to push the contact close.
Switch on and off during 20 years electrical power supply of a downstream installation with an
electrical and/or mechanical control.
Functional unit
The functional unit is characterized by a type 1NO or 1NC, a control circuit voltage 95V, a power
circuit voltage 690V and a maximum allowed intensity by the power circuit 9A.
Constituent materials
Reference product mass 370 g including the product, its packaging and additional elements and accessories
Substance assessment
Products of this range are designed in conformity with the requirements of the RoHS directive (European Directive 2011/65/EU of 8 June
2011) and do not contain, or only contain in the authorised proportions, lead, mercury, cadmium, hexavalent chromium or flame retardants
(polybrominated biphenyls - PBB, polybrominated diphenyl ethers - PBDE) as mentioned in the Directive
As the products of the range are designed in accordance with the RoHS Directive (European Directive 2002/95/EC of 27 January 2003),
they can be incorporated without any restriction in an assembly or an installation subject to this Directive.
Details of ROHS and REACH substances information are available on the Schneider-Electric Green Premium website
http://www2.schneider-electric.com/sites/corporate/en/products-services/green-premium/green-premium.page
ENVPEP1610006_V1 10/2016
EENVPEP1610006_V1 - Product Environmental Profile - EasyPact D3N 3P contactor,9A,20V,50Hz,1NO
End of life optimized to decrease the amount of waste and allow recovery of the product components and materials
No special end-of-life treatment required. According to countries’ practices this product can enter the usual end-of-life
End of life treatment process.
Based on “ECO’DEEE recyclability and recoverability calculation method”
Recyclability potential: 57% (version V1, 20 Sep. 2008 presented to the French Agency for Environment
and Energy Management: ADEME).
Environmental impacts
Use scenario Product dissipation is 9.25 W full load, loading rate is 30% and service uptime percentage is 30%
0
Geographical
China(75%),Europe(12.5%),India(12.5%)
representativeness
Technological An equipment to control the load by cutting the current quickly or connecting the main loop frequently. The
working principle is using the electromagnetism generated from the electriferous coil to push the contact
representativeness
close.
Manufacturing Installation Use End of life
Energy model used Energy model used: Electricity mix; AC; Electricity mix; AC; Electricity mix; AC;
China(SEMW,SSIC)and consumption mix, at consumption mix, at consumption mix, at
India(SEIL) consumer; 220V; CN consumer; 220V; CN consumer; 220V; CN
Impact indicators Unit Total Manufacturing Distribution Installation Use End of Life
Contribution to the soil and water acidification kg SO2 eq 1,28E+00 2,99E-03 2,18E-04 0* 1,28E+00 0*
kg CFC11
Contribution to ozone layer depletion 2,37E-05 1,60E-07 0* 0* 2,35E-05 0*
eq
Resources use Unit Total Manufacturing Distribution Installation Use End of Life
ENVPEP1610006_V1 10/2016
EENVPEP1610006_V1 - Product Environmental Profile - EasyPact D3N 3P contactor,9A,20V,50Hz,1NO
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
Contribution to Contribution to Contribution to Contribution to Contribution to Contribution to Net use of Total Primary
mineral the soil and water water global warming ozone layer photochemical freshwater Energy
resources acidification eutrophication depletion oxidation
depletion
ENVPEP1610006_V1 10/2016
EENVPEP1610006_V1 - Product Environmental Profile - EasyPact D3N 3P contactor,9A,20V,50Hz,1NO
Please note that the values given above are only valid within the context specified and cannot be used directly to draw up the environmental
assessment of an installation.
ENVPEP1610006_V1 10/2016