Installation Manual

Quidway SessionEngine2200 Session Border Controller Table of Contents

Table of Contents

Chapter 1 Product Overview ................................................................................................ 1-1


1.1 Int roduction to the SE2200 ......................................................................................... 1-1
1.2 Product Structure....................................................................................................... 1-1
1.2.1 Appearance of the SE2200 ............................................................................... 1-1
1.2.2 Indicators on the Front Panel ............................................................................ 1-3
1.3 System Configuration and Physical Parameters ........................................................... 1-3
1.4 General Modules ....................................................................................................... 1-4
1.4.1 RP U................................................................................................................ 1-4
1.4.2 PWR ............................................................................................................... 1-7
1.4.3 FAN ................................................................................................................ 1-8
1.4.4 Int erface Modules ............................................................................................ 1-9

Huawei Technologies Proprietary

i
Installation Manual
Quidway SessionEngine2200 Session Border Controller Chapter 1 Product Overview

Chapter 1 Product Overview

1.1 Introduction to the SE2200

The SE2200 is developed to serve as a Session Border Controller (SB C) at the edge
of current IP net works. It enables IP networks to bear NGN services, such as video
conference. The SE2200 is generally deployed at the egress of CPNs or enterprise
networks or on the convergence layer of Metropolitan Area Networks (MANs). It
solves such problems as NAT, NAT traversal, QoS and security defense for private
network subscribers. The SE2200 can also act as a border gateway between MANs
or Internet Service Providers (ISPs) to implement interworking between different
address domains and solve such problems as security, QoS and network hiding.

The SE2200 adopts special high-performance processors. Its high reliability and
modular hardware design eases scalability. The software of the SE2200 inherits the
Versatile Routing Platform (VRP ) of Huawei Technologies Co., Ltd., and is divided
into a managing system, a supporting system, a forwarding system and a processing
system. The SE2200 has the reliable and stable feat ures of Distribute Object-oriented
Programmable Real-time Architecture (DOP RA). This separates the upper services
from the lower layer operating systems and offers fine compatibility.

In addition to the protocol proxy, for example, Session Initiation Protocol (SIP ), Media
Gateway Control Protocol (MGCP), H.323 and H.248, the SE2200 provides the NGN
with such functions as dynamic firewall, NAT and L2& L3 QoS re-mark.

1.2 Product Structure

1.2.1 Appearance of the SE2200

The SE2200 consists of an integrat ed chassis, two power modules, a fan board and
some other service boards. These boards are horizontally placed in the chassis. The
3U-high standard chassis can be fixed in a 19” standard rack. The chassis is 436.2
mm in width, 420 mm in depth and 130.5 mm in height.

Huawei Technologies Proprietary

1-1
Installation Manual
Quidway SessionEngine2200 Session Border Controller Chapter 1 Product Overview

1) Slot 0 for Route Processing Unit (RPU) 2) Slot 1 for Interface Module
3) Slot 2 for Interface Module 4) ESD-preventive wrist strap jack

Figure 1-1 Front view of the SE2200

1) Fan board 2) PGND screw 3) AC power interface


4) Power switch 5) Power module 2 (PWR2) 6) Power module 1 (PWR1)
7) ESD-preventive wrist strap jack

Figure 1-2 Rear view of the SE2200

There are three slots on the front panel, slot 0 for RPU, and slots 1 and 2 for interface
modules.

Two PWRs, working in the 1+1 backup mode, are horizontally installed in the rear
panel providing DC-input or AC-input power supply as required. The fan board is
located at the left rear. Both PWRs and fan board are hot swappable. At the lower left
of the rear panel is an ESD-preventive wrist strap jack and at the top right is a PGND
screw.

Huawei Technologies Proprietary

1-2
Installation Manual
Quidway SessionEngine2200 Session Border Controller Chapter 1 Product Overview

1.2.2 Indicators on the Front Panel

The indicators on the front panel are mainly that of the RPU. For the detailed
description, refer to Table 1-2.

1.3 System Configuration and Physical Parameters

Table 1-1 System configuration and physical parameters

Item Description

Interface module slot 2

2 10/100Mbps Ethernet ports

Fixed interface 1 AUX port

1 console port

Processor PowerPC750 733 MHz

BootROM 512 KB

SDRAM 256 MB (may be extended to 512 MB)

NVRAM 512 KB

Flash 32 MB

Dimensions (W x D x H) (mm) 436.2 × 420 × 130.5

Weight 20 kg

Max. power 150 W

AC Input Rated voltage 100 V to 240 V AC; 50/60 Hz


voltage
Max. voltage 90 V to 264 V AC; 50/60 Hz

DC Input Rated voltage -48 V to -60 V DC


voltage
Max. voltage -36 V to -72 V DC
o o
Operating Long-term 0 C to 45 C
temperatu
o o
re Short-term -5 C to 55 C

Relative Long-term 5%RH to 85%RH (non-condensing)


humidity
Short-term 0%RH to 95%RH (non-condensing)

Huawei Technologies Proprietary

1-3
Installation Manual
Quidway SessionEngine2200 Session Border Controller Chapter 1 Product Overview

 Note:
Synchronous Dynamic Random Access Memory (SDRAM) is also known as the
memory that stores the communication data between the system and the CP U.
Non-Volatile Random Access Memory (NVRAM) stores the system configuration files
and running status information records.
Flash memory functions as the major file storage medium to store operating system
and application program files.
BootROM is to boot the read-only memory and stores the boot program file.
100 V to 240 V is a standard fluctuating range of AC-input power supply, but the
actual fluctuating range is 90 V to 264 V.
–48 V to –60 V is a standard fluctuating range of DC-input power supply, but the
actual fluctuating range is –36 V to –72 V.

1.4 General Modules

General modules of the SE2200 include RP U, PWR, FAN, and interface modules.

1.4.1 RPU

I. Functions

As the core of the SE2200, the RP U functions to process protocols, to forward


low-s peed data packets, to control interfaces, and to detect faults. The state
monitoring information, such as the operating status of the Fan, PWR, and the system,
can be shown directly through the indicators on the RPU. The FA N/PWR fault alarms
or system temperature alarms are reported to the Daemon. In addition, the RP U also
provides a hardware reset button.

Huawei Technologies Proprietary

1-4
Installation Manual
Quidway SessionEngine2200 Session Border Controller Chapter 1 Product Overview

II. Appearance

Figure 1-3 The RP U

III. Indicators and Buttons

Table 1-2 Description of the RP U front panel, indicators and buttons

Front panel

Indicator and
Description
button

System running indicator. Blinking means the CP U is in normal operation,


RPU
constant ON or OFF means the CP U has failed.

FAN FAN running indicator. Constant ON means the FA N is operating normally.

RUN PWR1 PWR1 running indicator. Constant ON means PWR1 is operating


(green) normally, and constant OFF means PWR1 is not installed properly or has
failed.

PWR2 PWR2 running indicator. Constant ON means PWR2 is operating


normally, and constant OFF means PWR2 is not installed properly or has
failed.

RPU System failure indicator. ON means the CPU has received an alarm signal
for PWR or FAN (due to overheating, for example).

ALM FAN FAN failure indicator. ON means the FA N is not installed properly or its
(red) rotation is obstructed.

PWR1 PWR1 failure indicator. ON means PWR1 has failed.

PWR2 PWR2 failure indicator. ON means PWR2 has failed.

RESET RPU hardware reset button.

LINK
10/100B OFF means the link is disconnected and ON means the link is connected.
(Green)
ASE-TX
indicator ACT OFF means no data is being transceived on the interface and blinking
(Yellow) means data is being transceived.

Huawei Technologies Proprietary

1-5
Installation Manual
Quidway SessionEngine2200 Session Border Controller Chapter 1 Product Overview

IV. Interface Attributes

1) Cons ole port

Table 1-3 Cons ole port attribut es

Attribute Description

Connector RJ-45

Interface
Asynchronous EIA/ TIA -232
standard

Baud rate 9600 bps to 115200 bps

9600 bps by default

Connect to the ASCII terminal.


Supported Connect to the serial port of the local PC and run terminal
service emulation program on the PC.

Command Line Interface (CLI).

2) AUX port

Table 1-4 AUX port attributes

Attribute Description

Connector RJ-45
Interface
Asynchronous EIA/ TIA -232
standard

Baud rate 300 bps to 115200 bps

Modem dialup
Supported
Backup
service
Serve as a configuration interface, when the cons ole port fails.

Supported
PPP
protocol

3) Ethernet port

The RPU provides two 10/100Base -TX Ethernet ports on its panel (Ethernet 0/0/0 at
left and Ethernet 0/0/1 at right). Their attributes are listed in the following table.

Huawei Technologies Proprietary

1-6
Installation Manual
Quidway SessionEngine2200 Session Border Controller Chapter 1 Product Overview

Table 1-5 Ethernet port attributes

Attribute Description

Connector RJ-45

Interface type MDI

Ethernet_II

Ethernet_SNAP
Supported frame format
IEEE 802.2

IEEE 802.3

10M/100Mbps auto-sensing
Operating mode
Full duplex/Half-duplex

Supported network protocol IP

1.4.2 PWR

I. Functions

The power supply system of the SE2200 comprises two PWRs. In normal situations,
the two PWRs (either supplying DC or AC power) function in a redundant way. The
input int erruption or failure of a PWR will not affect the operation of another PWR, and
this operating PWR will provide all the power required by the system.

The SE2200 provides two types of PWRs, AC PWR and DC PWR. The A C PWR uses
PSR350-A. The output power of each A C PWR is 350 W and the two-way outputs are
combined on the backplane. The DC PWR uses PSR350-D. The out put power of
each DC PWR is also 350 W and the two-way outputs are also combined on the
backplane. Power cables use D-type 3P IN -48 V feeder cables. In addition, the two
PWRs provide the overcurrent protection and overvoltage protection.

 Note:
If you want to install an SE2200 in a communication equipment room, you should
make sure that the power distribution cabinet can provide the lightning protection box
or arrester against the current of 20 kA and above.

Huawei Technologies Proprietary

1-7
Installation Manual
Quidway SessionEngine2200 Session Border Controller Chapter 1 Product Overview

II. Front Panel and Indicators

Table 1-6 Description of PWR front panel and indicators

AC front
panel

DC front
panel

Indicator Description

PWR failure indicator. ON means PWR is not installed properly or has


ALM (red)
failed.

RUN PWR running indicator. Constant ON means PWR is operating


(green) normally, and OFF means PWR has failed.

PWR input indicator (only on the AC PWR). Constant ON means the


AC OK
voltage (90 V t o 264 V) input is normal, while OFF means the voltage
(red)
input is abnormal.

1.4.3 FAN

I. Functions

The SE2200 is configured wit h six fans that are separated into three groups , as
shown in Figure 1-4. When all these fans are working normally, the operating
o o
temperature of the system can be maintained in the range of 0 C to 45 C. When a fan
fails, the other fans can still ensure the system operating in the normal t emperature.
The rotating speed of the fans is controlled by the RPU and is in the range of 50% to
100%. The FA N controller uses two parameters, low-temperature threshold and
high-temperature threshold to control the rotatin g speed of the fans. The former
corresponds to the 100% rotating speed and the latter corresponds to the 50%
rotating speed. The system will send out the rotation stop alarm signal in case that
any fan fails. The alarm and state indicators of FAN are located on the RPU front
panel.

II. Appearance

Figure 1-4 shows the FAN appearance.

Huawei Technologies Proprietary

1-8
Installation Manual
Quidway SessionEngine2200 Session Border Controller Chapter 1 Product Overview

Figure 1-4 The FAN

1.4.4 Interface Modules

 1-port 10B ase-T/ 100B ase-TX Fast Ethernet (FE ) interfac e card (1FE)
 2-port 10B ase-T/ 100B ase-TX FE interface card (2FE )
 1-port 100Base-FX Ethernet multi-mode fiber interface card (1MFX)
 1-port 100Base-FX Ethernet single-mode fiber interface card (1SFX)

For more information about interfac e modules, refer to “Chapter 7 Interface Modules”.

Huawei Technologies Proprietary

1-9