Calibration certificate Model: EARTH INSULATION TESTER Date: 2. 11. 2022 Serial No.:22240183 | Performed by: Luka Vrhovec Sree LUA oon : Metre! Recommended Cal Interval: (months ae "The due date may be established (by the customer) by adding the “Recommended Cal Interval” tothe "Date Paced In Service” No. Function / Ubat=5,5V input __| Low timit | Reading | Uncertainty ‘High +, Outlook, battery indication, keys,rotary switch, buzzer OK 2 Low ohm «2000 0.000 0002 0,00 ot 0020 Ry 1,000 0962 0,99 001 1049. aon 19,000 48.602 18,97 011 19,409 1900184301904 14 19572 = Continuity ee = 3 Clamp Current 0,0 mA 00mA Ot O41 0,3 mA i 10mA 9.2mA 10,0 01 10,8 mA 100mA 950A 99,8 1 105 mA 1A 950mA 4 001 105.8 410A 950A 10,00 Of 10,54, oA ek os ee 4 Tet > on ov 4 1 10V Urest 510k2 475V 514 4 545V soe —aV 903 BY 51 Insulation resistance /Uw=60V 0.000M2 0,000M2 0,000 0.001 .0N8 MA Riso 4000Ma «0.847 0,998 ~=—«0,009 1,053 M2 jg0ma —180,2M0—*187,6 49 199,8M0 Uiso output! 10M2 ee __ 65v 5.2 Insulation resistance / UN 0V 0,100 M2 0,096M2 0,100 0,001 0,104 MQ Riso 19.00M2 — 18,60M 19,08 012 1940M0 190,0Ma — 186,0M2_—189,8 12 194,0M2 a i aug 6a iba Gaye 20s en OLE a2h 8 C8 5.3. Insulation resistance / UN 1000V 100M2 978MQ_ =: 99,0 06 102,2MQ Riso 19062 182460 1,90 00319760 m0G2 15462 20,4 03 24660 Uso output/ 10M0 1050 1000 1100 v Sra cell cues ee eam, 3.0 ma 6 Voltage AC/DC ov ov 2V __bsav_87V 563.V 7 Earth resistance 0.000 0,002 0.030 four - lead method 1,000 0952 0,99 001 4,050 490002 18590 — 189,9 41 194,10 1.900k2 —1,859kQ 4,899 «0011 1.941 KO 19.00k2 — 1805k2 19,43 O41 19,95 kn. Probe influence Ro, Rp max 1,000 0920 0,99 oot 1,080 & Earth resistance 1 clamp 130002 18592 19,00 oft eae 190k2 ——-1.86KQ 1,89 001 194K 9 Earth resistance 2 clamp 1,000 0932 402 0.01 fora 1902 18.032 16,86 028 19970 10 S232 port, memories, header ‘OK All results in accordance with technical specification, Reference instruments: No insttument Type Certticate No, Due ce tn 9100, Wate ae eee METREL J. Tel.: (+386 1) 7558 200 METREL Ufrnne. 17 Pusat 8 Os SI 1354 HORJUL — hllp:www.matel si Mosturemeot and Regulavon Equipment Manufacturers SLOVENIA e-mail metiel@metiel si Metrel Certificate of Calibration Practices The Metre! Quality System is certified by BVQI according to Quality standard ISO 9001:2015, Certificate No. SL22466Q. The Metrel hereby certifies that the above instrument was calibrated in accordance with applicable Metrel calibration procedures during the manufacturing process. These processes are ISO 9001 controlled and are designed to assure that the instrument will meet its published specification. The Metrel further certifies that the measurement standards and instruments used during the calibration of this instrument are traceable to the (inter)national standards. The policies and procedures at this facility comply with EN ISO/IEC 17025. Environmental conditions: Temperature: 23 °C + 5 °C Relative humidity: 10 % to 75 % Calibration Procedure: “Name of Model / Type” Uncertainty: The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by coverage factor k = 2, which for a nominal distribution corresponds to a coverage probability of approximately 95%. The standard uncertainty of measurement has been determined in accordance with EA Publication EA-4/02. 7 77 te fs Edvard Reven Janko Mole Chief Executive Officer Head of Calibration Laboratory

You might also like