T H E R M A L A N A L Y S I S

DIFFERENTIAL Chip-DSC 100


Chip-DSC 10
SCANNING Chip-DSC 1

CALORIMETER
Since 1957 LINSEIS Corporation has been deliv-
ering outstanding service, know-how and lead-
ing innovative products in the field of thermal
analysis and thermophysical properties.

Customer satisfaction, innovation, flexibility


and high quality are what LINSEIS represents.
Thanks to these fundamentals our company
enjoys an exceptional reputation among the
leading scientific and industrial organizations.
LINSEIS has been offering highly innovative
benchmark products for many years.

The LINSEIS business unit of thermal analysis


is involved in the complete range of thermo-
Claus Linseis
analytical equipment for R&D as well as qual- Managing Director
ity control. We support applications in sectors
such as polymers, chemical industry, inorganic
building materials and environmental analytics.
In addition, thermophysical properties of solids,
liquids and melts can be analyzed.
LINSEIS provides technological leadership. We
develop and manufacture thermoanalytic and
thermophysical testing equipment to the high-
est standards and precision. Due to our innova-
tive drive and precision, we are a leading manu-
facturer of thermal analysis equipment.
The development of thermoanalytical testing
machines requires significant research and a
high degree of precision. LINSEIS Corp. invests
in this research to the benefit of our customers.

2
German engineering Innovation
The strive for the best due diligence and ac- We want to deliver the latest and best techno-
countability is part of our DNA. Our history is af- logy for our customers. LINSEIS continues to
fected by German engineering and strict quality innovate and enhance our existing thermal ana-
control. lyzers. Our goal is constant development of new
technologies to enable continuous discovery in
science.

3
DIFFERENTIAL SCANNING
CALORIMETER

Chip-DSC 1 Chip-DSC 10

Chip-DSC 100
4
The DSC Principle
The Differential Scanning Calorimetry (DSC) is the
most popular thermal analysis technique to measu-
re endothermic and exothermic transitions as a
function of temperature.
The instrument is used to characterize polymers,
pharmaceuticals, foods/biologicals, organic and
inorganic chemicals. Transitions measured include
Tg, melting, crystallization, curing, cure kinetics, oxi-
dation induction time and heat capacity.

Unsurpassed performance
• Revolutionary sensor design – combined
heat flux sensor and furnace in one chip.
• Unsurpassed sensitivity – for detection of
melts and weak transitions
• Benchmark resolution – precise separation of
close lying events
• Reliable automation – up to 96 position
autosampler
• Widest temperature range – from -180 °C to
600°C in one measurement

The LINSEIS Differential Scanning Calorimeters


(DSC) operate in agreement with national and in-
ternational standards such as: ASTM C 351, D 3417,
D 3418, D 3895, D 4565, E 793,
E 794, DIN 51004, 51007, 53765, 65467, DIN EN 728,
ISO 10837, 11357, 11409.

5
INTEGRATED CHIP
TECHNOLOGY
Reinventing Differential Scanning Calorimetry (DSC) –
Integrated chip technology for your application needs

Revolutionary Sensor Concept


The novel Chip-DSC integrates all essential parts The integrated design of the chip-sensor deli-
of DSC: furnace, sensor and electronics in a mi- vers superior raw data, which enables a direct
niaturized arrangement. The chip-arrangement analysis without pre- or post-processing of heat
comprises the heater and temperature sensor flow data.
in a chemically inert ceramic arrangement with
metallic heater and temperature sensor.

This arrangement allows superior reproducibili-


ty and due to the low thermal mass outstanding
temperature control and heating rates of up to
1000 K/min. The integrated sensor is easily user
exchangeable and available at a low cost.
New Chip-Sensor

Chip-DSC 10

6
Small Footprint
The compact construction leads to a signifi- consumption and unrivaled dynamic response
cant reduction in production cost which can results in unsurpassed performance of this revo-
be passed on to our customers. The low energy lutionary DSC-concept.

New chip
Usual DSC
technology

sample
furnace

temperature sensors
heater

reference

new technology allows for DSC miniaturization

Chip reduction: similar to the memory cards

7
COOLING OPTIONS
Peltier-cooling system (0 – 600°C) LN2-cooling system (-150 – 600°C)
This is a Peltier cooled heat exchanger. The Controlled cooling system for ultra-low tempe-
simple to install accessory reduces the star- rature application down to -150°C. This acces-
ting temperature of the DSC-sensor by 20°C in sory provides the openest flexibility and coo-
regards to room temperature. Due to the low ling capacity of all available options.
thermal mass of the sensor the DSC can now
reach linear heating from 10°C onwards. With Quench-cooling-system, (-180 – 600°C)
this starting temperature 90% of polymer appli- The quench-cooling accessory provides an
cations can be covered. open cooling container surrounding sensor
and sample. Coolant dependent, e.g. dry ice
Closed-loop intracooler (-100 – 600°C) or LN2, sample temperature can go down to
Closed cycle refrigerated cooling system. Can -180°C. This system does not allow defined gas
cool down to -100°C. This intracooler eliminates atmospheres while measuring, as outgasing
the need of refilling LN2 for cooling purposes. will surround the sample.

Quench-Cooling-System

8
ACCESSORIES
DSC-sample-press Crucibles
For optimum sample preparation of aluminum Various crucibles made of aluminum, alumina,
crucibles a ergonomic sample press is available. copper, gold, platinum and sapphire are availa-
ble for measurements with the Chip-DSC. Other
crucibles are available on request.

Sensor change Sample robot


The new user exchangable sensor can be re- The Chip-DSC 100 can be equipped with a
placed within a few seconds. This innovative rugged and reliable sample robot. Up to 96
concept reduces the maintenance costs drasti- samples increase the efficiency significantly.
cally.

9
HARDWARE OPTIONS
HP DSC
The 50/150 bar high pressure cell enables OIT
stability tests to monitor aging of polymers, oils
and fats.
Processes under high pressures can be simu-
lated and optimized, e.g. sorption, chemical
reactions etc.

Optical DSC
The Chip-DSC 100 can be equipped with a
CCD camera to observe the sample during
the measurement. The visualization of the
sample gives a much deeper insight to phase
transitions and decomposition processes.

Photo DSC
The Photo cell allows measurements under UV
light to investigate UV curing systems. Due to
the very short time constant of the chip sensor,
also fast UV curing reactions in the subsecond
time scale can be measured.

10
RAMAN DSC
The coupling of the Chip-DSC with a Raman
spectrometer can be realized very cost effec-
tively. In the Raman spectra the amorphous and
crystalline phases can be detected very precise-
ly and in situ.

Sample Robot DSC


The sample robot for up to 96 samples increases
the productivity significantly. The instrument
can run automatically overnight or at the week-
end. Together with the intuitive and intelligent
software it reduces labour costs and saves time.

Low temperature DSC


The cooling can be realized with a variety of coo-
ling options: intracooler, liquid nitrogen cooling
or a Peltier cooling system. The available tempe-
rature range at subambient conditions can be
extended down to -180°C.

11
SOFTWARE
Smart Software Solutions from LINSEIS

The software greatly enhances your workflow as • Complete evaluation history (all steps can be
the intuitive data handling only requires mini- undone)
mum parameter input. • Data acquisition and evaluation can be per-
AutoEval offers a valuable guidance for the user formed simultaneously
when evaluating standard processes such as • Data can be corrected using zero and calibra-
glass transitions or melting points. The optional tion correction
thermal library product identification tool, pro- • Data evaluation includes: peak separation soft-
vides a database with 600 polymers permitting ware signal correction and smoothing, first
an automatic identification tool for your tested and second derivative, curve arithmetic, data
polymer. peak evaluation, glass point evaluation, slope
Instrument control and/or surveillance through correction, zoom / individual segment display,
mobile devices gives you control wherever you multiple curve overlay, annotation and draw-
are. ing tools, copy to clipboard function, multiple
export features for graphic and data export,
• Software packages are compatible with latest reference based correction
Windows operating system
• Set up menu entries
• All specific measuring parameters (User, Lab,
Sample, Company, etc.)
• Optional password and user levels
• Undo and redo function for all steps
• infinite heating, cooling or dwell time seg-
ments
• multiple language versions such as English,
German, French, Spanish, Chinese, Japanese,
Russian, etc. (user selectable)
• Evaluation software features a number of
functions enabling a complete evaluation of
all types of data
• Multiple smoothing models

12
Thermal Library

The LINSEIS Thermal Library software package Thermal Library allows the comparison of the
comes as an option for the well-known, user complete curves with a data base providing
friendly LINSEIS evaluation software that is hundreds of references and standard materials
integrated in almost all our instruments. The within only seconds.

n
t i fi catio
rial Iden
Mate
and
g n i tion
co
u r ve re ystem
c s
DSC retation
p
inter

Measured and matching reference curves (green) and reference curves with poor fit (red).

Multi-Instrument Multi-Lingual
All LINSEIS instruments DSC, DIL, STA, HFM, LFA, Our software is available in many different user
etc. can be controlled from one software tem- exchangeable languages, such as: English,
plate. Spanish, French, German, Chinese, Korean,
Japanese, etc.

Multi-User Report Generator


The administrator can generate different user Convenient template selection to generate cu-
levels providing different rights to operate the stomized measurement reports.
instrument. An optional Log file is available, too.

Data Base Kinetic software


State of the art data base design enables easy Kinetic analysis of DSC, DTA, TGA, EGA (TG-MS,
data handling. TG-FTIR) data for the study of the thermal beha-
vior of raw materials and products.

13
SPECIFICATIONS
Chip-DSC 1 Chip-DSC 10 Chip-DSC 100
Chip-DSC 100S

Temperature range RT up to 450 °C RT up to 600°C –150°C up to +600(100S: 700°C)


(no cooling option available) -180 up to 600°C (with optional (depending on optional coo-
LN2 quench cooling) ling systems: Peltier, closed-
loop intracooler, LN2)

Heating and 0.001 up to 100 K/min 0.001 up to 300 K/min 0.001 up to 1000 K/min
cooling rates ballistic cooling with up to
500 K/min

Temperature accuracy +/- 0.2K +/- 0.2K +/- 0.2K

Temperature precision +/- 0.02K +/- 0.02K +/- 0.02K

Cool down time 2.7 min 2.7 min 2.7 min


400°C to 50 °C

Digital resolution 16.8 million points 16.8 million points 16.8 million points

Resolution 0.03 µW 0.03 µW 0.03 µW

Atmospheres inert, oxidizing (static, dyna- inert, oxidizing (static, dyna- inert, oxidizing (static, dyna-
mic) mic) mic), vacuum

Measuring range +/-2.5 up to +/-250mW +/-2.5 up to +/-250mW +/-2.5 up to +/-250mW

Calibration materials included included included

Calibration recommended 6-month inter- recommended 6-month inter- recommended 6-month inter-
val val val

Up to 80% less power consumption than standard DSC-instruments!

14
APPLICATION TAWN TEST
TAWN Test – Resolution

10

-10

-20

-30
DTA [µV]

-40

-50

-60

-70

-80

-90

100 105 110 115 120 125 130 135 140 145
Temperature [°C]
LINSEIS Chip-DSC TAWN I Resolution Test 20K/min

Scope
4,4´-Azoxyanisole reference material was used For the test an open aluminum crucible has
to perform the so called TAWN test. The sub- to be used. The atmosphere must be air, ar-
stance forms a liquid crystalline phase at 120°C gon or nitrogen, in this case we used air. The
which transforms into a further liquid phase at resolution is investigated with 5 mg of test
134°C with a small activation energy barrier in a substance and a heating rate of 20 K/min. The
second step. distance between the baseline to the mini-
This “double peak” is used in the TAWN test to mum of the curve between the two peaks is
investigate sensitivity and resolution of a DSC measured. The ratio of this height to the height
system and compare different DSC instruments of the second peak is the resolution. The result
with each other. of 0.13 is an excellent one.

15
APPLICATIONS
Measurement of PET granulate

15

10

0 Crystallisation

-5 Glass transition
-10
230.6°C
Heat Flow [mW]

-15

-20 148.0°C
79.8°C
-25

-30

-35 Melting

-40

-45

25 50 75 100 125 150 175 200 225 250 275 300


Temperature [°C]

The analysis of polymers is one of the main ap- heated, quench cooled to freeze the amorphous
plications of DSC. Effects like glass transitions, state and afterwards analyzed by Chip-DSC with
melting and crystallization points are of interest a linear heating rate of 50 K/min. The curve
and often very hard to detect. The new LINSEIS shows a significant glass transition around 80°C,
Chip-DSC provides high resolution and sensiti- followed by a cold crystallization of the amor-
vity, making it an ideal instrument for this kind phous parts starting around 148°C and a mel-
of analysis. As an example, a PET granulate was ting peak at 230°C.

16
High(est) temperature reproducibility test for Chip-DSC
To find out the limits of the Chip-DSC
0.0 700/S system, some more temperature
Onset point: 660.0°C tests were performed on the sensor. An
1st measurement
-0.1 Aluminum reference material was used
DTA [µV]

to prove the temperature stability of the


-0.2
sensor and its behavior at these high
temperatures. The sensor was heated to
0.0
2nd measurement Onset point: 660.5°C
700 °C to show the melting peak of the
Aluminum. During the durability test,
DTA [µV]

-0.1
this heating cycle was repeated 50 times
-0.2 and the sensor was still intact. The sen-
sor can therefore also be pushed to its li-
0.0 mits at 50 K/min, which is the advantage
3rd measurement Onset point: 661.1°C
of the new, miniaturized sensor design.
-0.1
Due to the high temperature, convec-
DTA [µV]

tion and thermal radiation have a much


-0.2
higher influence on the measurement.
This leads to a deviation of up to +- 1 K.
200 300 400 500 600 700
Temperature [°C] This limit for the accuracy at the highest
temperatures allows access to the high-
er temperature range up to 700 °C.
PET Cooling
Depending on the cooling rate, the
-10
grade of crystallinity of the polymer
changes significantly. During a fol-
-20 lowing heating run, cold crystalliza-
-30
tion can only be observed if crystal-
lization was not completed during a
-40 fast cooling run. If the previous coo-
-50
ling was slow, no glass transition or
Heat flow [mW]

crystallization can be observed. Wit-


-60 hout the need of any active cooling
16.47mg in aluminium pan
-70 all curves: 50 K/min heating rate such experiments with high cooling
blue curve after balistic cooling
green curve after 80 K/min cooling rate rates can be performed.
-80 yellow curve after 60 K/min
red curve after 40 K/min

-90

-100

50 100 150 200 250 300


Temperature [°C]

17
Indium sample: High heating rates
Extremely high heating rates up to
1000K/min can be achieved while the
Enthalpy: -28.45 J/g reproducibility of the melting enthal-
Heatingrate: 5 K/min
py remains excellent.
Enthalpy: -28.42 J/g
Heatingrate: 50 K/min The example shows the melting
Enthalpy: -28.59 J/g
point of Indium measured with diffe-
Heatingrate: 100 K/min rent heating rates (5 K/min; 50 K/min;
100K/min; 200K/min; 300 K/min and
Enthalpy: -28.48 J/g
Heatingrate: 200 K/min 500K/min).

Enthalpy: -28.71 J/g


Heatingrate: 300 K/min

Enthalpy: -28.55 J/g


Heatingrate: 500 K/min

120 140 160 180 200 220 240 260 280 300 320
Temperature [°C]

High cooling rates without active cooling


The LINSEIS Chip-DSC allows fastest
possible ballistic cooling rates wit-
100
hout any active coo- ler needed. Due
400 1.0 min | 400°C
to the low thermal mass and innova-
50
tive sensor design, cooling rates up to
350 0
500 K/min from 400°C on can be re-
-50 ached. Even cooling to 100°C can be
300
2.24 min | 100°C -100 done with cooling rates of up to 90 K/
Cooling speed [K/min]

Cooling rate: -87 K/min


250 -150 min. A cooling from 400°C down to
Temperature [°C]

-200
30°C can be done in 4 minutes just by
200 ballistic colling without need of any
-250
additional cooling devices.
150 -300
Of course, the signal can still be eva-
-350 luated during that cooling segment
100
5.0 min | 29.4°C -400 and does not lose sensitivity or accu-
RT: 24.1°C
-450 racy.
50
-500
This means that a complete analysis
Max. cooling rate: -503K/min
including heating and cooling can be
1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
Time [min] done in only 10 minutes without any
need for optional cooling devices.

18
OIT– Oxidation induction time
The oxidation and aging behavior
can be checked using the OIT test.
1400
200 9.2min
A small piece of LDPE was heated
117.4°C
1200
with 10K/min at constant argon flow
180
17.3min rate of 10 l/h. At 200°C, an isothermal
198.2°C
160
1000 segment was applied and later the
gas flow was switched from argon to

Differential Temperature [mK]


140
Temperature transition
800
oxygen at 10 l/h.
dynamic/static
Temperature [°C]

120
At the point where the heating ramp
600
after 3min goes into the isothermal segment,
temperature equilibrium
100 change from Ar to O2
400
there is a response « step » in the he-
80
atflow signal.
200 After the signal has become stable
60 21.14min 201.3°C
point of first deviation again, the atmosphere was changed
from stationary condition
40
0 to oxygen. Seven minutes after that,
the heat flow shows a significant
-200
20 change, which symbolizes the onset
0 10 20 30 40
Time [min] of the oxidation.

Cp determination
Beside the caloric measurements of
phase transitions and reactions, the
3.0
noise at start because of temperature control
Chip-DSC is also able to determine
2.5
the specific heat capacity. The Chip-
sample evaporates and Cp gets lower
2.0 Customer sample Cp (Cp) DSC can realize this with only one
Cp [J/g∙K]

1.5 crucible by using a definite tempera-


1.0 Sapphire lit (Cp) ture- modulated heating rate. There-
0.5
Sapphire measured (Cp) fore a calibration measurement with
a reference material (like sapphire) is
0
recorded, followed by the measure-
0.01 Correction raw data ment of the unknown sample that
0 can be evaluated using this calibra-
-0.01 tion.
HDSC [µV]

-0.02 The measurement shows the modu-


-0.03 lated measurement of heat capacity
-0.04 of sapphire at a heating rate of 10 K/
Customer sample raw data
-0.05 Sapphire raw data) min with amplitude of 3 K. Cp was de-
-0.06 termined with an error of 2%, repre-
0 5 10 15 20 25 30 35 senting an outstanding performance.
Time [min]

19
Thermochromism
10

-5

-10
Heat flow [mW]

-15

-20

-25

-30

-35

130 140 150 160 170 180


Temperature [°C]

In classical DSC instruments the sample cannot phase transition between 150 and 160°C. The
be observed during the measurement. Obser- phases have different colors and the color chan-
vation can give further useful information (for- ge from red to yellow can be seen through the
ming of bubbles, fumes, change of color, etc.). transparent cover. A camera option for recor-
The graphic above shows an example of a ther- ding images is available.
mochromic material, showing an endothermic

Gradient of a sample during a measurement

20
Highly energetic materials
450

400

350

300
Heat flow [mW]

250

200

150

100 Onset point: 279,2°C


Offset point: 288.7°C
Point of reaction: 205.721 mW at 282.0°C
Peak maximum: 446.625 mW at 287.3°C
50 Enthalpy: 1076.69 J/g

50 100 150 200 250 300 350


Temperature [°C]

Highly energetic materials are used in airbags, a damage to the instrument, the downtime of
as propellants, blasting materials etc. the instrument is reduced drastically. Change
For any type of DSC instrument, there is a risk oft he sensor needs only some seconds and the
of damaging the sensor and even the furnace. calibartion can be done in approx. 15 minutes.
In the Chip-DSC, the chip (integrating sensor The example shows the DSC diagram of 2,8 mg
and furnace) can be easily replaced by the ope- of airbag igniter.
rator at low cost and in a short time. In case of

21
UV curing of polymers

500 Onset point: 50.2°C (2min) 70


Offset point: 64.0°C (2min)
Point of reaction: 195.257 mW at 53.7°C (2min)
Peak maximum: 500.680 mW at 63.7°C (2min) 65
Enthalpy: 355.15 J/g
400 Onset point: 50.3°C (9min)
Offset point: 51.8°C (9min) 60
Point of reaction: 36.479 mW at 51.6°C (9min)
Peak maximum: 85.987 mW at 53.9°C (9min)
Enthalpy: 64.36 J/g
300 55
Heat flow [mW]

Temperature [°C]
50
200
45

100 40

35
0
30

0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0
Time [min]

The Linseis Chip DSC in combination with an


UV/LED source is a powerful tool for the cha-
racterization of fast photocurable resin systems
[L. Gonzales, University of Bayreuth].
In this specific case, a mixture of a photocura-
ble acrylate and thermally curable epoxy was
used and around 10 mg of material was placed
in an open crucible and irradiated with several
UV light pulses until no change in peak area was
detected.
The difference between the first irradiation
peak and the last one, (when the area under the
peak reaches a plateau, thus it is assumed that
no reaction is taking place), is calculated to de-
termine the heat of reaction for the UV-curing
part, and to derive a conversion curve.

22
Thermal analysis of chocolate

black cream chocolate 15.6°C 47.8°C


0
18.0°C

-20
35.5°C
white cream chocolate 8.8°C 47.2°C
0

-10 17.7°C
38.9°C
solid black white mix chocolate
Heat flow [mW]

30.9°C 52.1°C
0
-20
34.4°C
42.0°C
manufactured milk chocolate 28.5°C 43.9°C
0

-10
32.6°C
industrial milk chocolate 28.9°C 51.2°C
0
-5
44.4°C
-10 33.5°C

-40 -30 -20 -10 0 10 20 30 40 50 60 70 80


Temperature [°C]

A very interesting application for DSC is the The result shows that nearly all tested choco-
analysis of chocolate. It helps to investigate the lates show a double peak that is caused by low
melting behavior, melting temperature and fat melting milk fats and higher melting vegetable
content of different mixtures and therefore it is plant fats.
crucial for the design of a tasty, creamy product. The quality of emulsifiers and melting tempe-
The figure shows DSC profiles of five different rature can be compared and used for QC and
chocolate samples. Each sample was precooled product design. In this example, the handmade
with liquid nitrogen to -40°C and then measured chocolate shows a much more homogeneous
using the same conditions and similar sample melting behavior than cheaper industrial cho-
mass. colate.

23
LINSEIS GmbH Germany LINSEIS Inc. USA
Vielitzerstr. 43 109 North Gold Drive
95100 Selb Robbinsville, NJ 08691
Tel.: (+49) 9287 880 0 Tel.: (+1) 609 223 2070
E-mail: info@linseis.de E-mail: info@linseis.de

LINSEIS China LINSEIS France


Kaige Scientific Park 2653 Hunan Road 1 Route de Trévoux
201315 Shanghai 69250 Neuville/Saone
Tel.: (+86) 21 5055 0642 Tel.: (+33) 6.24.72.33.31
Tel.: (+86) 10 6223 7812 E-mail: contact@ribori-instrumentation.com
E-mail: info@linseis.de

LINSEIS Poland
ul. Dabrowskiego 1
05-800 Pruszków
Tel.: (+48) 692 773 795
E-mail: info@linseis.de

www.linseis.com