You are on page 1of 2

COLUMN NODE CONNECTION

NO OF THK OF SIZE OF FLANGE WEB


DETAIL ID CONN REMARKS DETAIL REMARKS
STIFFENER STIFFENER WELD WELD WELD
DUE TO BUCKLING FAILURE IN MIDDLE STIFFENER,
NC01 D01 3 10 FPBW FPBW 8 PROPOSED AS FPBW
NC02A D02 1 8 FPBW 8 6 -
NC03 D03 1 8 FPBW 10 8 -
NC02A D04 1 8 FPBW 8 6 -
NC02A D05 1 8 FPBW 8 6 -
NC02A D06 1 8 FPBW 8 6 -
NC02A D07 1 8 FPBW 8 6 -

NC04 D08 3 10 FPBW 8 6 DUE TO BUCKLING FAILURE IN MIDDLE STIFFENER,


PROPOSED AS FPBW
NC05 D09 2 8 FPBW 8 6 PUT MEMBER IPE400/IPE300 IN D17

NC06 D10 3 8 FPBW 8 6 DUE TO BUCKLING FAILURE IN MIDDLE STIFFENER,


PROPOSED AS FPBW
NC02A D11 1 8 FPBW 8 6 -
NC02A D12 1 8 FPBW 8 6 -
NC02B D13 1 8 FPBW 8 6 -
NC07 D14 2 10 FPBW 8 6 BUCKLING 10.74
NC07 D15 2 10 FPBW 8 6 BUCKLING 7.07
Detail markup given but kurijnji changed the location for
NC03 D16 1 8 FPBW 10 8 -
blowup detail to D03. Not followed my markups.
NC05 D17 2 8 FPBW 8 6 -
NC02B D18 1 8 FPBW 8 6 -
NC02B D19 1 8 FPBW 8 6 -
NC08 D20 8 8
NC09 D21 8 8 FOLLOW IDEA FILE FOR CONNECTION
NC09 D22 8 8
NC08 D23 8 8 FOLLOW IDEA FILE FOR CONNECTION
NC02A D24 1 8 FPBW 8 6 -
NC02A D25 1 8 FPBW 8 6 -
NC03 D26 1 8 FPBW 10 8 -
NC03 D27 1 8 FPBW 10 8 -
CONNECTION DESIGN SUMMARY
Flange
CONN Strain % Bolt % Weld % Buckling Web Weld
Weld
D01 2.4 - 88.9 16.85 FPBW 8
D02 0.7 - 80.2 35.34 8 6
D03 2.1 - 82.4 27.94 8 6
D04 0.5 - 86.1 31.50 8 6
D05 0.1 - 79.0 31.97 8 6
D06 0.7 - 80.2 39.92 8 6
D07 0.1 - 79.8 44.12 8 6
D08 0.9 - 77.6 20.72 FPBW 8
D09 0.4 - 88.9 26.22 8 6
D10 0.0 41.5 77.3 27.07 8 6
D11 0.3 - 83.0 25.40 8 6
D12 0.5 - 85.0 28.99 8 6
D13 1.1 - 87.1 35.98 8 6
D14 0.3 - 82.8 18.59 8 6
D15 0.7 - 84.9 13.07 8 6
D16 1.2 - 85.8 32.44 8 6
D17 0.0 - 77.8 21.63 8 6
D18 0.4 - 79.7 35.78 8 6
D19 0.4 - 81.3 46.30 8 6
D20 1.0 47.7 77.0 12.64 FPBW 8
D21 1.3 82.6 86.8 21.25 FPBW 8
D22 0.0 8.8 47.6 21.08 FPBW 8
D23 0.0 53.4 76.4 25.49 FPBW 8
D24 0.2 - 88.0 85.60 8 6
D25 0.3 - 87.4 54.04 8 6
D26 1.7 - 89.8 29.42 10 8
D27 0.2 - 76.6 54.57 10 8