Professional Documents
Culture Documents
All Dimension in mm
WALL THICKNESS MEASUREMENT RESULT
Spot Number / Actual Thickness
No Serial No. / Least Remarks
Spot Location 1 2 3 4 5 6 7 Point
A 5.26 5.40 5.40 5.26
1 Shell 1'1 B 5.37 5.44 5.46 5.37
C 5.37 5.43 5.47 5.37
A 5.52 5.44 5.45 5.44
B 5.33 5.40 5.45 5.33
2 Shell 1'2
C 5.31 5.44 5.42 5.31
D 5.17 5.24 5.06 5.06
A - - - 0.00
B - - - 0.00
3 Shell 2'1
C - - - 0.00
D 5.20 - - 5.20
A 5.40 5.41 5.60 5.40
B 5.28 5.21 5.44 5.21
4 Shell 2'2
C 5.40 5.35 5.35 5.35
D 5.31 5.34 5.22 5.22
A 5.35 - - 5.35
B 5.29 - - 5.29
5 Shell 3'2
C 5.34 - - 5.34
D 5.29 - - 5.29
A - - 5.31 5.31
B - 5.28 - 5.28
6 Shell 4'2
C - 5.34 - 5.34
D 5.33 - - 5.33
A 4.55 4.52 4.52 4.52
B 4.53 4.52 4.50 4.52 4.52 4.51 4.52 4.50
C 4.52 4.50 4.54 4.56 4.50
D 4.56 4.57 4.55 4.51 4.55
7 Plate Top Roof
E 4.37 4.51 4.55 4.55 4.37
F 4.55 4.51 4.46 4.46
G 4.57 4.49 4.51 4.48 4.49
H 4.54 4.47 4.51 4.47
8 N-1 5.07 5.51 5.16 5.07
9 N-2 5.68 5.71 5.68 5.68
10 MH - 1 no data thickness
11 MH - 2 5.24 5.27 5.21 5.29 5.21
12
13
Examined by : Approved by :
ASNT UT LEVEL - II Client Representative
Roof
N1
A F
D
Ladder
N2
MH2 B G
C E
H
Examined by : Approved by :
ASNT UT LEVEL - II Client Representative
Shell
Examined by : Approved by :
ASNT UT LEVEL - II Client Representative
Roof
A F
D
Ladder
N2
MH2 B G
C E
N1 H
Examined by : Approved by :
Inspector Client Representative
Examined by : Approved by :
Inspector Client Representative