You are on page 1of 4
Huet Oy, MP (MAD tees Chas 2 210008349164 - —w CNAS LO102 a ate h \ He Mg Test Report kK 2023WJWT00262 fa PB PR Product Name AHA Steel Pipe Plate Hf Ble EY EIR IIT 58 BE — 3 BB China Railway Indonesia Jakarta ke BH W Bandung High Speed Rail Project Manager Consignor Division 1 PERMA BERR Test Category Consign Sent Test BRIN TH OM FH Ly Xuzhou Inspection Testing Center, EeL2€ PAR I SGP HH dy ‘National Quality Inspection and Testing Center for Space Frame and Steel Structures NTR HOMIE ey Xuzhou Inspection Testing Genter Fl eH AR Be $02 HA) = or Fie A HM Hy National Quality Inspection and Testing Genter for Space Frame and Stee! Structures he Fe fe UN He Test Report 2023K,JNT00262 TL 1 Page Now 2-1 © 450%25 Q355B BA PBI 7 7 _ |_Svecification Product Name WEH Steel Pipe Plate FRSR Product Grade 26 PERERA AM A BaF at wae China Railway Indonesia Jakarta ke Bandung High Speed Rail Project | RRA Manager Division yh Consignor | wane Address Telephone Roane Fae Test Category Consign Sent Test Sample Quantity BEAM -0- ReRAOH ’ a Sample Date 23-01-17 ‘Tee Date 2023-01-17 . aR #AIMWARThe samples are satisfied with testing requirements cat 1591-2018 (RAR RBRAWA) igh strength low alloy - 4 structural steels) GB/T 13793-2016 (Hattas?4#F) (Steel pipes with HIREMSAVEIRIE |e jongitudinal clectric (resistance) weld) (BHAHABRD (Principal technical requirements) Sample Condition Test Criteria PEeeAa a, PRT Lael 13793-2016hRHERI CERADRER) BLE HRM BE Test Conclusion HAAS Related nessage prosest Nane:Jakarta-Bandung “High-Speed Railway Padelarang Station 1. AERO REA T. The test is responsible for the received & sample only. 2. HREM AMER BRIE AE, HAH HREA AK. Note |The information in the thick wireframe is provided by the client, lwhose authenticity is the responsibility of the client. ay FE hil, BO Ae HO alls, pA mw ® WAR Test Result 2023WJWT00262 SE 2 TW 2 GW Page No. 2-2 HAIR 9 ee | mmmmmn fom | Ti ceman | AO ‘NO. Test Item Unit i Test Result Requirements Result am 568 Pass npn oh : Tensile Strength | MP* ap 576 Pass tt 584 Pass 23 ae wirat KR ate 2 | Percentage Elongation | — 218 22 e ‘After Fracture% Pass a 4 Pass ge wR he ERED NOTE 1, RET MAE AE MA ROAR, ‘The report is invalid without "special seal for Inspection and testing" or the official seal of inspection and {esting unit. 2, SME RMR NS MN EAA NAAR. ‘The copy report is invalid without re-stamping of "special seal for inspection and testing" or the offical seal of inspection and testing unt, 3 HAREM, WH HARPER, Test reports invalid without signature of main inspector, assessor and approver. 4, RERREM. Test reports invalid with any alter. 5, RAEI AMM M RIOR, ROM MIRON RECT Ae HA, TRARCRMOMATEER, ‘The inspection and testing organization is only responsible for the entusted inspection samples received.The conchision of this test report is based on the testing criteria and only forthe tasted items, 6, RADAR I ETN te" THE This test report shall not be used for advertising 7. ARN BS SEBAARM ANAS TAA ( NAMI ) SO MTA THR eR SOREN ‘The remaining samples must be collected within three months after receiving the test report(f the limit time is shor, it shall be subject tothe period of vaity) The overdue samples will be dealt with, in accordance with the provisions ofthe inspection and tasting institution, 8, SAMOA RARK LTH If there is any objection to the inspection results, see the following conditions. 2) SHAME, ATRAEA 15 AMARANTE KOO For entrusted testing, written re-inspection application shall be submitted to the inspection and testing institution within 18 days after receiving the report, >) FRARREHEN ATE (ORERBOS) ZAATTAA AMR RMRRM a SEAR SRR For products quailty inspection supervision testing, written re-inspection application shall be submitted within 18 days after receiving the test result notice to Market Supervision and Administration Departments that organize the implementation of supervision and inspection. ©) Ramee AAAI AD , AIA SY (ANNALS) 2 BAR PLA RCH HT ARS AM MAN, For food safety sampling inspection testing, written re-inspaction application shall be submitted within 7 days after receiving the test result notice to Market Supervision and Administration Departments that ‘organize the implementation of supervision and inspection, MM ARHRUARA LTR COMBA) OER tno objection is raised within the time limit, shall be deemed to accept the results ofthe inspection and testing report. Sith: LAR ON TR OO 12 ‘Address: No. 12 of Shangju Road, Yuniong District, Xuzhou, Jiangsu Province AEH : 0516-67022581 ‘Supervisory Telephone:0516-67022581 AUSsi8 : 0516-67022501 67022502 Business Telephone:0516-67022501 67022502 SPUALIEDIE : 0516-67022505 Demurral Disposal Telephone:0516-67022505 #80 : 0516-67022545 Fax : 0516-67022545 sim: 221018 Zip code : 221018 F868: xuzhouzhiian@163.com E-mallxuzhouzhijan@163.com

You might also like