Calibration Service
Calibration Service
This is a professional and guaranteed service able to provide all certified instruments both current and voltage as performed by the
clients the calibration of all the measuring instruments fitted in the machine. In MIG/MAG also welding wire speed is to be controlled in
welding equipment. the same way.
Whenever such a test is positive, a proper certificate is also released
WHAT’S CALIBRATION? complete with all detected data and the power source is to be fitted
In arc welding process, welding quality itself is strictly subordinated, with a sticker stating the test result together with its validity date.
in addition to the experience and professionality of the operator, to Such a service has got various options ranging from calibration
the precision in adjusting and repeating same parameters, such as made in CEA factory just after the machine is completed on the
welding current, voltage and wire speed (MIG/MAG welding). assembly line, to calibration made directly at the final user’s.
Calibration means to verify the measuring precision of the
instruments being utilized in your own welding equipment. This
must fully meet what prescribed by EN 50504 norm, which clearly
states methods, instruments and allowed tolerances as necessary for
each operation.
CEA CALIBRATION
CEA calibration is obtained by connecting the power source to a
conventional load in order to measure by means of precise and
Type of unit: MIG / MAG welding machine with separate wire feeder
SET POINTS WIRE SPEED METER
MAX
MEASURED AVERAGE DISPLAY AVERAGE
Power source: DIGITECH 5000 VISION PULSE Serial number: YB 107 011 WIRE SPEED WIRE SPEED WIRE SPEED WIRE SPEED DISP IND
ALLOWED ERROR
ERROR
Equipment function under test: VOLTAGE CURRENT WIRE SPEED DISPLAYS 18,9 18,40 18,9 ± 1,89 0,50
MEAS 4,2 18,5 18,9
MEAS 5,1 24,3 25,0
Validation method: Conventional load resistor – MIG/MAG (CV) / rotary transducer 25,0 24,30 25,0 ± 2,50 0,65
MEAS 5,2 24,3 24,9
Validation type: Accuracy x Consistency
CALIBRATION EQUIPMENT
Validation grade: Standard x Precision Validation range: Full range REF DESCRIPTION CAL DATE EXPIRE
CEA E153 SMP 1286 - LOAD RESISTOR AND ROTARY TRANSDUCER JAN 2016
Power source rated Power source rated min Power source no_load CEA MD39 FLUKE 77 – MULTIMETER FOR WELDING VOLTAGE OCT 2016
500A 10A 70V
max current: current: voltage: CEA E138 CURRENT SENSOR – 1000A 5V 1% JAN 2016
Max allowed error of Max allowed error of CEA MD47 METRAHITPRO – MULTIMETER FOR WELDING CURRENT JAN 2016
± 12.5 A ± 1.75 V
display A (±2.5 %): display V (±2.5 %):
CALIBRATION RESULT
Wire feed speed rated 0.6 Wire feed speed 25 Max allowed error ± 10 % of set
min value: m/min rated max value: m/min of wire feed speed: value RESULT: Passed x Failed
Ambient temperature: 25°C Input voltage: 400V Input voltage frequency: 50Hz APPROVED BY: A. VALSECCHI SERVICE MANAGER: