You are on page 1of 4

参数设置 Parameter Settings

长按 3 秒左右,出现“000”进入编程模式:

Long press for about 3 seconds, "000" appears to enter the programming

mode

注:在显示模式下(即编程前显示器有显示时),长按 先关闭显示,再次长按 才能进入

编程模式。
Note: In the DISPLAY mode (that is, when the display is displayed before
programming), long press first to close the display, and long press

again to enter the programming mode.

进入编程模式
3 秒 press 3s 000 Go to programming
mode
tPA 进入间隔时间设置
press
Interval Setting
press 显示当前设定值(h) 使用上/下键更改
Displays the current

1
Use the up/Down keys
interval in hours(h)
to change
进入运行时间设定
tCO Enter the runtime
Settings
显示当前设定(min) 使用上/下键更改
Displays the current
Use the up/Down keys
working interval(min)
to change
进入运行/监测模式设定
COP Enter the run/monitor
mode setting
使用上/下键切换,当选
OFF=递进系统关闭监测
择 PS 功能后,tCO 运行
CS=递进系统开启监测
时间不可用,系统默认
PS=单线(卸压)、双线
为内部监测时间 30min
系统
OFF= Progressive
system turns OFF
When the PS function
monitoring
is selected, the tCO
CS= Progressive
running time is
system open
unavailable. The
monitoring
system sets the
PS= single wire
internal monitoring
(pressure relief),
time to 30 minutes by
double wire system
default
系统从间隔时间开始倒
计时;采用进入/退出编
保存更改并退出编程;
程操作可以进行强度停
任何时候都可以长按保
止电机运行
存退出 Save your
The system starts
changes and exit the
三秒 press 3s counting down from
program;
the interval time.
You can long press to
The entry/exit
save and exit at any
programming operation
time
can be used to stop
the motor operation
在间隔周期中可以随时
报警状态下确认报警并
强制启动油泵工作一个
复位输出,同时启动一
循环
次循环
The pump can be
In the alarm state,
forcibly started for
confirm the alarm and
one cycle at any time
reset the output,
during the interval
while starting a loop
cycle
1#灯=CS 当启用了此功能后,在
2#灯=PS 间隔周期内对应的指示
1 # light = CS 灯会亮起,运行周期时
2 # light = PS 对应相关的输入信号亮/

2

After this function
is enabled, the
corresponding
indicator light will
be on during the
interval period, and
the corresponding
input signal will be
on or off during the
operation period

故障显示 fault display


FLL Low level Lubricating oil less

bLo Jam alarm Clean valve and butter


pipe
FOC Motor overload Check whether the voltage is
too low
FOP High output voltage Check whether the spool is
blocked
Err Fault recording time Accumulated fault time

3
4

You might also like