FOUNDATION
FOUNDATION
+10410
C38,C32 +11380
+11460
+12360
SW6,C19 +12510
+13910
+15185
+15335
+17165
C23,C39, +18515
+19015
+19315
+19465
+3480
+3630
+6380
+6530
SW1,C31, +7440
+8480
+300
· ALL DIMENSION ARE IN MILLIMETERS EXCEPT WHERE
150MM PLINTH PROTECTION MENTIONED OTHERWISE.
+0
· THE DRAWING SHALL NOT BE MEASURED.
300MM THICK RUBBLE SOILING · THE WRITTEN DIMENSIONS ARE STRICTLY TO BE FOLLOWED.
POINT (X)
POINT (X)
· INTERNAL BRICK WALLS ARE 150MM AND EXTERNAL BRICK
C20,C26,
RAMMED EARTH
C11,C14,
C15,C17,
C13C16,
C21,C27
C30,C36
C22,C28
C7,C10,
WALLS ARE 230MM THICK.
C8,SW3
C33,C39
C18,24
START
C3,C9,
· BRICKS TO BE LAID WITH FROGS UPWARDS.
C2,C5
C1,C4
· DRIP MOULD TO BE PROVIDED TO ANY PROJECTIONS.
SW2
SW1
SW5
C34
END
C37
C25
C35
C12
· ALL INTERNAL PLASTER IS 15MM THICK IN 1:6 PROPORTION
C6
15MM THICK INTERNAL PLASTER CEMENT MORTAR IN SINGLE COAT.
150MM THICK PCC BED (1:3:6) · ALL EXTERNAL PLASTER IS 25MM THICK IN PROPORTION.
CEMENT MORTAR AND APPLIED IN DOUBLE COAT.
· ALL DIMENSIONS ARE FROM UNFINISHED TO UNFINISHED.
25MM THICK CONCRETE COVER END A B C D E F G H I J K L M N O P Q R S · LEVELS ARE MENTIONED WITH REFERENCE TO THE ROAD
LEVEL.
+24560 POINT (Y) · ALL DRAWINGS TO BE CHECKED THOROUGHLY BY THE SITE
ENGINEER BEFORE THE EXECUTION OF WORK.
PLINTH BEAM 300MM X 900MM
300
· THE DIMENSIONS OF STRUCTURAL MEMBERS,FOOTING SIZES,
4107 4107
10MM DIA STIRUPS 150MM C/C SHALL BE AS PER THE DESIGN BY THE STRUCTURAL
D DESIGNER.
300MM THICK RUBBLE SOILING C36,C37, 19' 19 · STRUCTURAL DRAWINGS PREPARED BY THE STRUCTURAL
+24260 PB29 300X600 PB30
ENGINEER SHALL BE REFERED FOR THE SAME.
C38,C39 300X600
F37 C37 300X600 300X600
2200
2200
2200
RAMMED EARTH F36 C36
F38 C38 F39 C39
2050
600X300 600X300
F34 C34 F35 C35 COLUMN SCHEDULE FOOTING SCHEDULE
10MM DIA LINKS @ 250MM C/C
PB39
3960
3960
PB48
COLUMN SIZE COLUMN SIZE FOOTING SIZE FOOTING SIZE
PB51
PB60
3480 3480 C-01 300 X 600 C-21 600 X 300 F-01 1200 X 1500 F-21 1500 X 1200
16MM DIA LOGITUDINAL BAR (6 C-02 300 X 600 C-22 600 X 300 F-02 1200 X 1500 F-22 1500 X 1200
1310
300X600
12MM DIA BAR AT Y-AXIS 300X600
F33 C33
C-06
C-07
300 X 600
600 X 300
C-26
C-27
600 X 300
600 X 300
F-06
F-07
1200 X 1500
1500 X 1200
F-26
F-27
1500 X 1200
1500 X 1200
F31 C31 C-08 300 X 600 C-28 600 X 300 F-08 1200 X 1500 F-28 1500 X 1200
12MM DIA BAR AT X-AXIS C-09 300 X 600 C-29 600 X 300 F-09 1200 X 1500 F-29 1500 X 1200
C30,C31, C-10 600 X 300 C-30 300 X 600 F-10 1500 X 1200 F-30 1200 X 1500
PB67
C-13 600 X 300 C-33 300 X 600 F-13 1500 X 1200 F-33 1200 X 1500
PB36
C-14 600 X 300 C-34 600 X 300 F-14 1500 X 1200 F-34 1500 X 1200
PB25 1130 1130 PB26 C-15 600 X 300 C-35 300 X 600 F-15 1500 X 1200 F-35 1200 X 1500
C-16 600 X 300 C-36 300 X 600 F-16 1500 X 1200 F-36 1200 X 1500
C-17 600 X 300 C-37 300 X 600 F-17 1500 X 1200 F-37 1200 X 1500
150MM THICK PCC BED (1:3:6)
2420
C-18 600 X 300 C-38 300 X 600 F-18 1500 X 1200 F-38 1200 X 1500
PB38
C-19 300 X 600 C-39 300 X 600 F-19 1200 X 1500 F-39 1200 X 1500
PB59
PB47
600X300 C-20 600 X 300 - - F-20 1500 X 1200 - -
F28 C28
2870
2870
PB54
SCHEDULE OF PLINTH BEAM
300MM THICK RUBBLE SOILING 600X300 600X300
BEAM SIZE DEPTH BEAM SIZE DEPTH
F26 C26 F27 C27
C26,C27, PB-01 300MM 600MM PB-35 300MM 600MM
900
PB23 PB24
PB46
PB21 PB22 PB-05 300MM 600MM PB-39 300MM 600MM
5900 PB-06 300MM 600MM PB-40 300MM 600MM
PB-07 300MM 600MM PB-41 300MM 600MM
600X300
SECTION AA' +17580 C24,25 15' F29 C29 15 PB-08 300MM 600MM PB-42 300MM 900MM
PB58
PB66
PB37
300MM 600MM 300MM 900MM
PB35
PB-09 PB-43
(scale 1: 30) PB-10 300MM 900MM PB-44 300MM 900MM
600X300 PB20 PB-11 300MM 900MM PB-45 300MM 900MM
1250
F24 C24 600X300 600X300 PB-12 300MM 900MM PB-46 300MM 600MM
PB45
F25 C25 F22 C22 PB-13 300MM 600MM PB-47 300MM 600MM
PB-14 300MM 600MM PB-48 300MM 600MM
PB53
PB-18 300MM 900MM PB-52 300MM 600MM
PB16 PB17 PB18 PB19 PB-19 300MM 600MM PB-53 300MM 900MM
300MM X 600MM COLUMN 300MM 900MM 300MM 900MM
PB44
PB-20 PB-54
PB-21 300MM 600MM PB-55 300MM 600MM
1880
PB-22 300MM 600MM PB-56 300MM 600MM
600X300 600X300 600X300
+14450 C19 13' F20 C20 F21 C21 F23 C23 13 PB-23
PB-24
300MM
300MM
900MM
900MM
PB-57
PB-58
300MM
300MM
600MM
900MM
PB-25 300MM 600MM PB-59 300MM 900MM
150
PB-26 300MM 600MM PB-60 300MM 900MM
PB-27 300MM 600MM PB-61 300MM 600MM
PB65
450
PB34
300X600
RCC ISOLATED SLOPED C18 12' 12
20860
+14300 F19 C19
PB-29
PB-30
300MM
300MM
600MM
600MM
PB-63
PB-64
300MM
300MM
600MM
900MM
PB43
18660 600X300
150MM THICK PCC BED SCHEDULE OF SHEER WALL
15150
F17 C17
SR.NO. SHEER WALL NO. SHEER WALL SIZE (L X B).
2400MM X 300MM
PB52
02 SW2
(scale 1: 30) 03 SW3 300MM X 2400MM
600X300 PB13 PB14 04 SW4 300MM X 2400MM
300MM X 2400MM
F16 C16 05 SW5
PB42
06 SW6 300MM X 2400MM
100
100
100
100
100
100
100
100
100
100
100
100
100
100
2675
+9880 SW3,SW4 10
PB33
PB64
10' KEY PLAN: E.O.B E.O.B
SW5,SW5
C D
PB12
S+12 FLOOR
ADJACENT PLOT
+8530 SW1,SW2 8
825
600X300 PB10
100 BAR (6 NO.S) F13 C13
PB9 PB11
1500
1200
100
A'
100
PB32
PB50
PB63
PB57
2400X300 2400X300
100 10MM DIA LINKS @ 250MM C/C SW1 SW2
A
B
F.O.B
1470
PB41
F.O.B(0,0)
START POINT(0,0)
ENTRY
CC-33
450X450
CC-32
450X450
CC-31
450X450
CC-30
450X450
CC-29
450X450
SLOPE 1:8
EXIT
F10 C10 F9 C9
1500 +6880 C9 6' 6 STAMP & CERTIFICATION OF COLLEGE:
PB40
1800
PB31
2880
PB62
PB56
PLAN THROUGH FOOTING (scale 1: 30)
4860
+4000 C8 5' 300X600 300X600 5
300X600 F5 C5 F6 C6
PB49
150
600X300 F8 C8 300X600
1800 SIGNATURE OF PROFESSOR:
1500
+3850 C7 4' F7 C7
PB5
F4 C4
4
6525 PB3
RCC ISOLATED SLOPED
1430
PB61
PB55
BAR (6 NO.S)
1500
1200
3500
450
300
2350
CONTENTS OF THE SHEET:
1900
300X600 300X600
F1 C1 F2 C2
PB1
A
+0
END
3555
E.O.B N
POINT (Y)
PLAN THROUGH COLUMN (scale 1: 30) F.O.B(0,0) SUMIT VARMA
START POINT(0,0)
FOUNDATION LAYOUT A' B' C' D' E' F' G' H' I' J' K' L' M' N' O' P' Q' R' S'
ROLL No.: AR-20-068, Year: 3rd, (SEM - VI)
03 (SCALE= 1:50)
ADITYA COLLEGE OF ARCHITECTURE