Measuring Air Performance Characteristics of Central Vacuum Cleaning Systems
Measuring Air Performance Characteristics of Central Vacuum Cleaning Systems
for the
Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.
1. Scope E177 Practice for Use of the Terms Precision and Bias in
1.1 This test method covers procedures for determining air ASTM Test Methods
performance characteristics of household central vacuum E691 Practice for Conducting an Interlaboratory Study to
cleaning systems, which use a flexible cleaning hose assembly Determine the Precision of a Test Method
and incorporates a series universal motor(s). This test method E2251 Specification for Liquid-in-Glass ASTM Thermom-
does not apply to the carpet cleaning mode of operation where eters with Low-Hazard Precision Liquids
dirt or debris is involved. F431 Specification for Air Performance Measurement Ple-
num Chamber for Vacuum Cleaners
1.2 These tests and calculations include determination of
2.2 AMCA Standard:4
suction, airflow, air power, maximum air power, and input
210–85 Laboratory Methods of Testing Fans for Rating
power under standard operating conditions (see Note 1).
2.3 IEC Standard:5
NOTE 1—For more information on air performance characteristics, see IEC 62885-2 Surface Cleaning Appliances – Part 2: Dry
Refs (1-6).2
Vacuum Cleaners for Household or Similar Use – Meth-
1.3 The values stated in inch-pound units are to be regarded ods for Measuring the Performance
as the standard. The values given in parentheses are provided
for information only. 3. Terminology
1.4 This standard does not purport to address all of the 3.1 Definitions:
safety concerns, if any, associated with its use. It is the 3.1.1 air power, AP, W, n—in a vacuum cleaner, the net time
responsibility of the user of this standard to establish appro- rate of work performed by an air stream while expending
priate safety, health, and environmental practices and deter- energy to produce an airflow by a vacuum cleaner under
mine the applicability of regulatory limitations prior to use. A specified air resistance conditions.
specific precautionary statement is given in Note 4. 3.1.2 automatic bleed valve, n—any device a part of a
1.5 This international standard was developed in accor- vacuum cleaner’s design, which automatically introduces an
dance with internationally recognized principles on standard- intentional leak within the vacuum cleaner’s system when
ization established in the Decision on Principles for the manufacturer specified conditions are met.
Development of International Standards, Guides and Recom-
mendations issued by the World Trade Organization Technical 3.1.3 corrected airflow, Q, cfm, n—in a vacuum cleaner, the
Barriers to Trade (TBT) Committee. volume of air movement per unit of time under standard
atmospheric conditions.
2. Referenced Documents 3.1.4 input power, W, n—the rate at which electrical energy
2.1 ASTM Standards:3 is absorbed by a vacuum cleaner.
E1 Specification for ASTM Liquid-in-Glass Thermometers 3.1.5 model, n—the designation of a group of vacuum
cleaners having the same mechanical and electrical construc-
1
This test method is under the jurisdiction of ASTM Committee F11 on Vacuum tion with only cosmetic or nonfunctional differences.
Cleaners and is the direct responsibility of Subcommittee F11.22 on Air Perfor-
mance. 3.1.6 population, n—the total of all units of a particular
Current edition approved Feb. 1, 2021. Published February 2021. Originally model vacuum cleaner being tested.
approved in 1988. Last previous edition approved in 2018 as F820 – 18. DOI:
10.1520/F0820-21.
2
The boldface numbers in parentheses refer to the list of references at the end of
4
this standard. Available from Air Movement and Control Association, Inc., 30 West Univer-
3
For referenced ASTM standards, visit the ASTM website, www.astm.org, or sity Dr., Arlington Heights, IL 60004–1893, http://www.amca.org..
5
contact ASTM Customer Service at service@astm.org. For Annual Book of ASTM Available from the IEC Web store, webstore.iec.ch, or American National
Standards volume information, refer to the standard’s Document Summary page on Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036,
the ASTM website. http://www.ansi.org..
Copyright © ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States
F820 − 21
3.1.7 repeatability limit (r), n—the value below which the 5.3 Power analyzer, to provide measurements accurate to
absolute difference between two individual test results obtained within 61 %.
under repeatability conditions may be expected to occur with a 5.4 Barometer, with an accuracy of 60.05 in. (1.27 mm) of
probability of approximately 0.95 (95 %). mercury, capable of measuring and displaying absolute baro-
3.1.8 reproducibility limit (R), n—the value below which the metric pressure, scale divisions 0.02 in. (0.51 mm) or finer.
absolute difference between two test results obtained under 5.4.1 Mercury barometers, in general, measure and display
reproducibility conditions may be expected to occur with a the absolute barometric pressure. Some corrections may be
probability of approximately 0.95 (95 %). needed for temperature and gravity. Consult the owner’s
3.1.9 repeatability standard deviation (Sr), n—the standard manual.
deviation of test results obtained under repeatability condi- 5.4.2 When purchasing an aneroid or electronic barometer,
tions. be sure to purchase one which displays the absolute barometric
pressure, not the mean sea level equivalent barometric pressure
3.1.10 reproducibility standard deviation (SR), n—the stan-
value. These types of barometers generally have temperature
dard deviation of test results obtained under reproducibility
compensation built into them and do not need to be corrected
conditions.
for gravity.
3.1.11 sample, n—a group of vacuum cleaners taken from a
large collection of vacuum cleaners of one particular model, 5.5 Orifice Plates—See Specification F431.
which serves to provide information that may be used as a basis 5.6 Thermometer—Solid-stem, ambient thermometer hav-
for making a decision concerning the larger collection. ing a range from 18 °F to 89 °F (or –8 °C to +32°C) with
3.1.12 standard air density, ρstd, lb/ft3, n—atmospheric air graduations in 0.2 °F (0.1 °C), conforming to the requirements
density of 0.075 lb/ft3 (1.2014 kg/m3). for thermometer 63 °F (17 °C) as prescribed in Specification
3.1.12.1 Discussion—This value of air density corresponds E1. As an alternative, thermometers S63F or S63C, as pre-
to atmospheric air at a temperature of 68 °F (20 °C), 14.696 psi scribed in Specification E2251, may be used. In addition,
(101.325 kPa), and approximately 30 % relative humidity. thermometric devices such as resistance temperature detectors
(RTDs), thermistors, or thermocouples of equal or better
3.1.13 suction, inch of water, n—in a vacuum cleaner, the
accuracy may be used.
absolute difference between ambient and subatmospheric pres-
sure. 5.7 Psychrometer—Thermometers graduated in 0.2 °F (0.1
°C).
3.1.14 test run, n—the definitive procedure that produces
the singular result of calculated maximum air power. 5.8 Voltage-Regulator System, to control the input voltage
3.1.15 test station pressure, Bt, inch of mercury, n—for a to the vacuum cleaner. The regulator system shall be capable of
vacuum cleaner, the absolute barometric pressure at the test maintaining the vacuum cleaner’s rated voltage 61 % and
location (elevation) and test time. rated frequency 61 Hz having a wave form that is essentially
3.1.15.1 Discussion—It is not the equivalent mean sea level sinusoidal with 3 % maximum harmonic distortion for the
value of barometric pressure typically reported by the airport duration of the test.
and weather bureaus. It is sometimes referred to as the 5.9 Orifice Adapter Tube—See Fig. 1.
uncorrected barometric pressure (that is, not corrected to the
mean sea level equivalent value). Refer to 5.4 for additional 6. Sampling
information. 6.1 A minimum of three units of the same model vacuum
3.1.16 unit, n—a single vacuum cleaner of the model being cleaner selected at random in accordance with good statistical
tested. practice, shall constitute the population sample.
6.1.1 To determine the best estimate of maximum air power
4. Significance and Use for the population of the vacuum cleaner model being tested,
4.1 The test results allow the comparison of the maximum the arithmetic mean of the maximum air power of the sample
air power available when no dirt has been introduced into the from the population shall be established by testing it to a 90 %
vacuum cleaning system, that is, a completely clean filter or an confidence level within 65 %.
empty, clean dirt container. 6.1.2 Annex A2 provides a procedural example for deter-
mining the 90 % confidence level and when the sample size
5. Apparatus shall be increased.
5.1 Plenum Chamber—See Specification F431 or IEC NOTE 2—See Annex A2 for method of determining 90 % confidence
62885-2, Section 5.8.3. level.
5.2 Water Manometers, or equivalent instruments. One to 7. Test Vacuum Cleaners
measure from 0 in. to 6 in. (152.4 mm) in increments of 0.01
in. (0.254 mm), and one with increments of 0.1 in. (2.54 mm) 7.1 New Test Vacuum Cleaner—Run the vacuum cleaner in
for use in making measurements above 6 in. (152.4 mm). A at rated voltage 61 % and rated frequency with filters in place
single instrument having a resolution of 0.01 in. (0.254 mm) for 1 h with a wide-open inlet (without hose).
over the entire required range may be used instead of two 7.2 Used Test Vacuum Cleaners—Recondition a used test
separate instruments. vacuum cleaner; prior to the initial test run as follows:
2
F820 − 21
3
F820 − 21
8.1.5 Connect a power analyzer. plates also may be used: 2.5, 2.25, 1.75, 1.375, 1.125 in. (63.5,
8.2 Test Procedure: 57.2, 44.5, 34.9, 28.6 mm).
8.2.1 Connect the hose assembly to the plenum chamber 8.2.6 For each orifice plate, record the suction, h, and input
hose adapter and seal only this connection (see Fig. 3). power, P, in that order. All readings should be taken within 10
8.2.1.1 The end of the hose assembly should be inserted s of the orifice insertion. For orifices less than 0.750 in. allow
inside the hose connector adapter and be perpendicular to the the vacuum cleaner to operate at the open orifice for 1 to 2 min
plenum chamber. before inserting the next orifice.
8.2.1.2 The end of the hose assembly shall not project into 8.2.6.1 Read the suction to the nearest graduation of the
the plenum chamber. instrument. Readings should be taken as soon as the manom-
8.2.1.3 Any automatic bleed valve, which affects the air eter reaches a true peak. When using a fluid type manometer,
performance of the vacuum cleaner, shall not be defeated. the liquid level may peak, drop, and peak again. The second
8.2.2 The hose should be supported and kept straight and peak is the true peak reading. A person conducting the test for
horizontal over its entire length. Allowance should be made for the first time shall observe at least one run before recording
the foreshortening of the hose assembly under the vacuum. data. See Specification F431 for instructions on how to
Maintain the power unit and dirt canister in their normal minimize the overshoot (first peak) of the liquid level.
operating orientation. 9. Calculation
8.2.3 Operate the vacuum cleaner with no orifice plate
inserted in the plenum chamber inlet at nameplate rated voltage 9.1 Correction of Data to Standard Conditions:
61 % and frequency 61 Hz prior to the start of the test run to 9.1.1 Air Density Ratio—The density ratio, Dr, is the ratio of
allow the unit to reach its normal operating temperature. For the air density at the time of test ρtest, to the standard air
vacuum cleaners with dual nameplate voltage ratings, conduct density, ρstd = 0.075 lb/ft3 (1.2014 kg/m3). It is used to correct
testing at the highest voltage. Allow the unit to reach its normal the vacuum and wattage readings to standard conditions. Find
operating temperature before each test run. ρtest (lb/ft3 or kg/m3) from standard psychometric charts or
8.2.4 The vacuum cleaner is to be operated at its nameplate ASHRAE tables and calculate Dr as follows:
rated voltage 61 % and frequency 61 Hz throughout the test. ρ test
Dr 5 (1)
For vacuum cleaners with dual nameplate voltage ratings, ρ std
conduct the test at the highest voltage.
where:
8.2.4.1 Allow the vacuum cleaner to operate at the open
orifice for 15 seconds minimum between test runs. ρtest = the air density at the time of test, lb/ft3 (kg/m3), and
8.2.5 While operating the vacuum cleaner in accordance ρstd = the standard air density, 0.075 lb/ft3 (1.2014 kg/m3).
with 8.2.4, insert orifice plates sequentially into the orifice 9.1.1.1 As an alternative, the following equation is intended
plate holder of the plenum chamber starting with the largest to be used for correcting ambient conditions where the baro-
size orifice and following it with the next smaller orifice plate. metric pressure exceeds 27 in mercury and the dry-bulb and
Use the following orifice plates: 2.0, 1.5, 1.25, 1.0, 0.875, 0.75, wet-bulb temperatures are less than 100 °F (37.8 °C); and, may
0.625, 0.5, 0.375, 0.25, 0.0 in. (50.8, 38.1, 31.7, 25.4, 22.2, be used as an alternate method of calculating Dr (see Appendix
19.0, 15.8, 12.7, 9.5, 6.3 mm). The following optional orifice X1 for derivation and accuracy analysis).
4
F820 − 21
Dr 5
F
17.68 B t 2 0.001978 T w2 10.1064 T w 1
0.0024575B t ~ T d 2 T w ! 2 2.741 G (2)
NOTE 1—K1 was determined experimentally using an ASTM Plenum
Chamber (see Specification F431) and an ASME Flowmeter (1).
T d 1459.7
NOTE 2—Equations for K1 in terms of Bt and h, are given in Appendix
where: X6.
Bt = test station pressure at time of test, inch of mercury, Orifice Diameter, in. (mm) Orifice Flow Coefficient EquationA
Td = dry-bulb temperature at time of test, °F, and 0.250 (6.3) 0.5575r20.5955
Tw = wet-bulb temperature at time of test, °F. K1 5
r21.0468
9.1.2 Corrected Suction—Corrected suction, hs, is the ma- 0.375 (9.5) 0.5553r20.5754
K1 5
r21.0263
nometer reading, h, times the correction factor, Cs, as follows:
0.500 (12.7) 0.5694r20.5786
hs 5 Cs h (3) K1 5
r21.0138
9.1.2.1 For series universal motors (6) the correction factor, 0.625 (15.8) 0.5692r20.5767
K1 5
r21.0104
Cs, is calculated as follows:
0.750 (19.0) 0.5715r20.5807
C s 5 110.667~ 1 2 D r ! (4) K1 5
r21.0138
0.875 (22.2) 0.5740r20.5841
9.1.2.2 This test method does not have any formulas avail- K1 5
r21.0158
able for correcting input power for any other type of motor
1.000 (25.4) 0.5687r20.5785
(permanent magnet, induction, etc.). K1 5
r21.0146
9.1.3 Corrected Input Power—Corrected input power, Ps,
1.125 (28.6) 0.5675r20.5819
expressed in watts, is the wattmeter reading, P, times the K1 5
r21.0225
correction factor, Cp, as follows: 0.5717r20.5814
1.250 (31.7)
K1 5
P s 5 C pP (5) r21.0152
1.375 (34.9) 0.5680r20.5826
9.1.3.1 For series universal motors the correction factor, Cp, K1 5
r21.0235
is calculated as follows: 1.500 (38.1) 0.5719r20.5820
K1 5
C p 5 110.5~ 1 2 D r ! (6) r21.0165
1.750 (44.5) 0.5695r20.5839
9.1.3.2 This test method does not have any formulas avail- K1 5
r21.0235
able for correcting input power for any other types of motor 2.000 (50.8) 0.5757r20.5853
(permanent magnet, induction, etc.). K1 5
r21.0157
9.2 Corrected Airflow—Calculate the corrected airflow, Q, 2.250 (57.2)
K1 5
0.5709r20.5878
r21.0279
expressed in cubic feet per minute (see Note 4 and Appendix
X2) as follows: 2.500 (63.5) 0.5660r20.59024
K1 5
r21.0400
Q 5 21.844 D 2 K 1 =h s (7)
A
B t s 0.4912d 2h s 0.03607d
r5
where: B t s 0.4912d
where:
Q = corrected flow, cfm,
Bt = test station pressure at time of test, in. of mercury, and
D = orifice diameter, in., h = uncorrected suction (manometer reading), in. of water.
K1 = constant (dimensionless) orifice flow coefficients for
orifices in the plenum chamber. See Table 1 for values
for each orifice. See Ref (1) for the derivation of these
flow coefficients, and
NOTE 4—For the corrected airflow expressed in liters per second, use
hs = corrected suction, water, in.
the following equation:
5
F820 − 21
TABLE 2 Repeatability and Reproducibility
Q 5 10.309D 2 K 1 =h s (8)
Coefficient of Repeatability Coefficient of Reproducibility
where: Variation, Limit, r Variation, Limit, R
Q = corrected flow, L/s, CV %r CV %R
D = orifice diameter, m,
1.5 4.3 9.0 25.1
K1 = constant (dimensionless),
hs = corrected suction, Pa.
9.3 Air Power—Calculate the air power, AP, in watts, as 11.5.1 The expected coefficient of variation of the measured
follows: results within a laboratory, CV %r, has been found to be the
AP 5 0.117354 ~ Q !~ h s ! (9) respective values listed in Table 2.
where: 11.5.2 The 95 % repeatability limit within a laboratory, r,
has been found to be the respective values listed in Table 2,
AP = air power, W, where r = 2.8 (CV %r).
Q = corrected flow, cfm, and
11.5.3 With 95 % confidence, it can be stated that within a
hs = corrected suction, inch of water (see Appendix X3 for
laboratory a set of measured results derived from testing a unit
derivation).
should be considered suspect if the difference between any two
9.4 Maximum Air Power—Determine the maximum air of the three values is greater than the respective value of the
power using the method in Annex A1. repeatability limit, r, listed in Table 2.
10. Report 11.5.4 If the absolute value of the difference of any pair of
measured results from three test runs performed within a single
10.1 For each vacuum cleaner sample from the population laboratory is not equal to or less than the respective repeatabil-
being tested, report the following information: ity limit listed in Table 2, that set of test results shall be
10.1.1 Manufacturer’s name and product model name or considered suspect.
number, or both.
10.1.2 Type of filtration; that is, paper bag, cloth bag, foam 11.6 Reproducibility (Multiday Testing and Single Operator
filter, centrifugal, etc. Within Multilaboratories)—The ability to repeat the test with
10.1.3 The corrected input power, corrected vacuum, cor- multiple laboratories.
rected airflow, and air power for each orifice. 11.6.1 The expected coefficient of variation of reproducibil-
10.1.4 Manufacturer’s parts, catalog, or model number of ity of the average of a set of measured results between multiple
the ductwork, fittings, and flexible cleaning hose assembly laboratories, CV %R, has been found to be the respective
used in the test. values listed in Table 2.
10.1.5 Calculated or measured maximum air power, which- 11.6.2 The 95 % reproducibility limit within a laboratory, R,
ever is greater. has been found to be the respective values listed in Table 2,
where R = 2.8 (CV %R).
11. Precision and Bias 11.6.3 With 95 % confidence, it can be stated that the
11.1 The following precision statements are based on inter- average of the measured results from a set of three test runs
laboratory tests involving nine laboratories and four units. performed in one laboratory, as compared to a second
laboratory, should be considered suspect if the difference
11.2 The statistics have been calculated as recommended in between those two values is greater than the respective values
Practice E691. of the reproducibility limit, R, listed in Table 2.
11.3 The following statements regarding repeatability limit 11.6.4 If the absolute value of the difference between the
and reproducibility limit are used as directed in Practice E177. average of the measured results from the two laboratories is not
11.4 The Coefficients of Variation of repeatability and equal to or less than the respective reproducibility limit listed
reproducibility of the measured results have been derived from in Table 2, the set of results from both laboratories shall be
nine sets of data, where each set has been performed by a considered suspect.
single analyst within each of the nine laboratories on two 11.7 Bias—No justifiable statement can be made on the bias
separate days using the same unit test.6 of this test method for testing the properties listed. The true
11.5 Repeatability (Single Operator and Laboratory; Mul- values of the properties cannot be established by acceptable
tiday Testing)—The ability of a single analyst to repeat the test referee methods.
within a single laboratory.
12. Keywords
6
Complete data on the round-robin test is available from ASTM Headquarters. 12.1 airflow; air performance; air power; residential central
Request RR:F11-1003. Contact ASTM Customer Service at service@astm.org. vacuum cleaners; suction; suction power; vacuum cleaners
6
F820 − 21
ANNEXES
(Mandatory Information)
7
F820 − 21
where:
A2.1 Theory: CI = Confidence Interval (U - upper limit; L - lower limit),
A2.1.1 The most common and ordinarily the best estimate x̄ = mean score of the sample taken from the population,
of the population mean, µ, is simply the arithmetic mean, x̄, of t = t statistic from Table A2.1 at 95 % confidence level,
the individual scores (measurements) of the units comprising a s = standard deviation of the sample taken from the
sample taken from the population. The average score of these population, and
units will seldom be exactly the same as the population mean; n = number of units tested.
however, it is expected to be fairly close so that in using the A2.1.7 It is desired to assert with 90 % confidence that the
following procedure it can be stated with 90 % confidence that true population mean, µ, lies within the interval, CIU to CIL,
the true mean of the population, µ, lies within 5 % of the centered about the sample mean, x̄; therefore, the quantity
calculated mean, x̄, of the sample taken from the population as ts/ =n shall be less than some value, A, which shall be 5 % of
stated in Section 6. x̄ in accordance with the sampling statement of 6.1.
A2.1.2 The following procedure provides a confidence in- A2.1.8 As n→`, ts/ =n→0. As this relationship indicates, a
terval about the sample mean which is expected to bracket µ, numerically smaller confidence interval may be obtained by
the true population mean, 100(1-α) % of the time where α is the using a larger number of test units, n, for the sample; therefore,
chance of being wrong; therefore, 1-α is the probability or level when the standard deviation, s, of the sample is large and the
of confidence of being correct. level of confidence is not reached after testing three units, a
A2.1.3 The desired level of confidence is 1-α = 0.90 or 90 % larger sample size, n, shall be used.
as stated in Section 11; therefore, α = 0.10 or 10 %.
A2.2 Procedure (A graphical flow chart for the following
A2.1.4 Compute the mean, x̄, and the standard deviation, s, procedure is shown in Fig. A2.1.):
of the individual scores of the sample taken from the popula-
tion: A2.2.1 Select three units from the population for testing as
n
the minimum sample size.
1
X̄ 5
n (X
i51
i (A2.1) A2.2.2 Obtain individual test unit scores by averaging the
results of three test runs performed on each of the three
s5 !(
n
n
i51
X i2 2 S( D n
i51
Xi
2
(A2.2)
individual test units. The data set resulting from the three test
runs performed on each individual test unit shall meet the
n ~n 2 1! respective repeatability requirement found in Section 11.
where: A2.2.3 Compute x̄ and s of the sample.
n = number of units tested, and A2.2.4 Compute the value of A where A = 0.05 (X).
Xi = the value of the individual test unit score of the ith test A2.2.5 Determine the statistic t for n – 1 df from Table A2.1,
unit. As will be seen in the procedural example to where n = the number of test units.
follow, this is the average value of the results from three
test runs performed on an individual test unit with the A2.2.6 Compute ts/ =n for the sample and compare it to the
resulting set of data meeting the repeatability require- value to A.
ments of Section 11. A2.2.7 If the value of ts/ =n.A, an additional unit from the
A2.1.5 Determine the value of the t statistic for n – 1 population shall be selected and tested, and the computations
degrees of freedom, df, from Table A2.1 at a 95 % confidence of steps A2.2.2 – A2.2.6 repeated.
8
F820 − 21
A2.2.8 If the value of ts/ =n,A, the desired 90 % confi- A2.3.2 Test run scores for test unit No. 1:
dence level has been obtained. The value of the final x̄ may be Test Run No. 1 = 146.0
used as the best estimate of the air power rating for the Test Run No. 2 = 136.5
Test Run No. 3 = 142.5
population.
A2.3.3 Maximum spread = 146.0 – 136.5 = 9.5
A2.3 Example—The following data is chosen to illustrate 9.5
how the value of air power for the population of a vacuum % difference 5 maximum spread/maximum score 5
146.0
5 6.51 %
cleaner model is derived. The measured test results from three
(A2.6)
test runs on each unit are required to have a repeatability limit
not exceeding the value as indicated in Section 11. This value is greater than the repeatability limit required in
A2.3.1 Select three test units from the vacuum cleaner Section 11. The results shall be discarded and three additional
model population. A minimum of three test runs shall be test runs performed.
performed using each test unit. A2.3.4 Test run scores for Test Unit No. 1:
9
F820 − 21
A2.3.5 Maximum spread = 146.7 – 146.0 = 0.7 A2.3.8 x̄ = 1⁄3 (146.2 + 144.4 + 153.4) = 148.0
0.7 A2.3.9
% difference 5 maximum spread/maximum score 5 5 0.48 %
146.7
(A2.7) s5 Œ 3 @ ~ 146.2! 2 1 ~ 144.4! 2 1 ~ 153.4! 2 # 2 @ 146.21144.41153.4# 2
3~3 2 1!
s5 Œ fs
4 146.2d 2 1 s 144.4d 2 1 s 153.4d 2 1 s 148.2d 2 g 2 f 146.21144.41153.41148.2g 2
4s4 2 1d
(A2.9)
s = 3.89
A2.3.17 A = 0.05 (148.1) = 7.4. A2.3.21 Thus, the value of x̄, 148.0, represents the air power
A2.3.18 Df, n – 1 = 4 – 1 = 3 score for the vacuum cleaner model tested and may be used as
t0.95 statistic = 2.353. the best estimate of the air power rating for the population
mean.
A2.3.19 ts/ =n52.353 ~ 3.89! / =454.58.
A2.3.20 4.58 < 7.4 (meets requirements).
APPENDIXES
(Nonmandatory Information)
10
F820 − 21
5
70.7261
53.34
3 S~ B t 2 e ! 10.622e
T d 1459.7 D X1.3.6 Conclusion:
X1.3.6.1 The worst-error condition is with low barometric
1.32595 ~ B t 2 0.378e ! condition, high wet-bulb temperature, and 100 % relative
5 humidity.
T d 1459.7
X1.2.6 X1.3.6.2 If the Dr equation is restricted to minimum value
of B = 27.00 in. of mercury absolute and maximum value of Tw
ρ test ρ test
Dr 5
ρ std
5
0.075
(X1.7) = 100 °F (37.8 °C) then at the worst-case condition of 100 %
relative humidity the Dr error = +0, –0.23 %.
17.68 ~ B t 2 0.378 e !
5
T d 1459.7
11
F820 − 21
X3.1 Power is defined as the rate of doing work in a given AP 5 745.7/33000 Fv (X3.2)
period of time and can be expressed by the following general
where:
equation:
AP = air power, W,
P 5 Fv (X3.1) F = force generated by the air stream passing through the
where: orifice, lb,
v = velocity, ft/min.
P = power,
F = force, and X3.2.1 The constant 745.7/33 000 is used to maintain the
v = velocity. correct set of units:
X3.2 Air power as defined in 3.1.1, is the net time rate of 33 000 ft·lb
1W5 (X3.3)
work performed by an air stream while expending energy to 745.7 min
produce air flow by a vacuum cleaner under specified air
X3.3 For an air stream passing through a given orifice size:
resistance conditions, expressed in watts; therefore air power
is: X3.3.1 The force is given by the following equation:
12
F820 − 21
1 Q = flow rate at standard, air density and temperature, cfm,
F5 p h sA (X3.4)
12 and
where: A = cross sectional area of the orifice, ft2.
F = force generated by air stream passing through the X3.4 Substituting equations from X3.3.1 and X3.3.2 into
orifice, lb,
the equation in X3.2, p = 62.3205 lb/ft3, and simplifying as
p = density of water at (68 °F), 62.3205 lb/ft3,
hs = differential pressure at standard conditions, water, in., follows:
and AP 5 0.117354 h s Q (X3.7)
A = cross sectional area of the orifice, ft2.
where:
X3.3.1.1 The constant 1⁄12 is used to maintain the correct set
AP = air power, W,
of units:
hs = differential pressure at standard conditions, inch of
1 ~ ft! ~ lb! water, and
F ~ lbs! 5 p 3 h s ~ in.! A ~ ft2 ! (X3.5)
12 ~ in.! ~ ft ! Q = flow rate at standard air density and temperature, cfm.
X3.3.2 The velocity is given by the following equation: X3.4.1 This equation is used to calculate the air power in
V 5 Q/A (X3.6) 9.3.
where:
V = velocity of air stream passing through the orifice, ft/min,
Manometer Reading,
Orifice Diameter,
h, in. H2O
in. (mm)
min max
0.250 (6.3) 0.1 109
0.375 (9.5) 0.1 100
0.500 (12.7) 0.1 91
0.625 (15.8) 0.1 81
0.750 (19) 0.1 72
0.875 (22.2) 0.1 63
1.000 (25.4) 0.1 55
1.250 (31.7) 0.1 40
1.500 (38.1) 0.1 26
2.000 (50.8) 0.1 11
13
F820 − 21
NOTE X6.1—These equations are the results of substituting the r equation into the Table 1 K1 equations.
Orifice Diameter, in. (mm) Flow Coefficient Orifice Diameter, in. (mm) Flow Coefficient
X7.1 This example shows the calculations of air density for TABLE X7.1
two different test locations at two different elevations and the Orifice Input Power, Suction, Airflow, Air Power,
results of the maximum air power calculations. Diameter Ps hs Q AP
(in.) (watts) (in. H2O) (cfm) (air watts)
X7.2 This example attempts to show the importance of 2.500 768 1.70 107.2 21.4
2.000 766 3.80 101.9 45.5
using the test station pressure or absolute barometric pressure 1.750 761 6.00 97.7 68.8
in the calculations of the air density instead of the equivalent 1.500 757 9.40 88.7 97.9
mean sea level value of the absolute barometric pressure. 1.375 750 11.70 83.6 114.8
1.250 742 14.30 76.4 128.3
X7.2.1 Air density or the weight of the air per unit volume 1.125 731 17.70 68.7 142.8
1.000 716 21.50 60.1 151.7
at a particular test location is influenced by the local weather 0.875 693 25.70 49.8 150.3
conditions, the test location’s height above sea level, the 0.750 666 30.40 39.7 141.7
heating, cooling and ventilation system of the test facility, etc. 0.625 637 35.20 29.6 122.3
0.500 603 40.20 20.1 94.9
X7.2.1.1 In general, air density decreases as the elevation 0.375 566 44.50 12.2 63.7
increases. The amount of the atmosphere above the test 0.250 538 47.00 5.9 32.6
location decreases as elevation increases; thus, the weight of 0.000 519 49.30 0.0 0.0
the air above the test location decreases resulting in a lower air
density.
X7.2.1.2 Air density is affected by the amount of moisture
power of the vacuum cleaner described in X7.3 in accordance
within the air. Water vapor adds weight to the air.
with Specification F558. At the test location and test time, the
X7.3 For this example, a vacuum cleaner having the fol- laboratory measured the test station pressure, Bt, the wet bulb
lowing characteristics at standard air density conditions as temperature, Tw, and the dry bulb temperature, Td. Their values
described in 3.1.12 will be used in Table X7.1. were recorded as follows:
Bt = 29.10 in. Hg
X7.3.1 The calculated maximum air power for this unit is Tw = 61.0 °F
152 air watts. Td = 70.0 °F
X7.3.2 It will be assumed that this cleaner performs per- X7.4.1.1 The test station pressure, Bt, or absolute baromet-
fectly each time it is used, that is, no motor performance ric pressure was measured with a mercury barometer. The
variations, the hose is laid out the exact same way for each test actual reading of the barometer was adjusted for latitude and
etc. temperature according to the mercury barometers instruction
manual.
X7.4 Test Location 1: Low Elevation X7.4.1.2 The test laboratory also recorded the equivalent
X7.4.1 In Harrisburg, PA, an independent test laboratory mean sea level barometric pressure value. This value was
located 355 ft above sea level measured the maximum air obtained from their local airport. It was 29.50 in. Hg and
14
F820 − 21
TABLE X7.2
Measured Data Corrected Data (Data at Standard Conditions)
Orifice Input Input Power, Suction, Airflow, Air Power,
Suction
Diameter Power Ps hs Q AP
(in. H2O)
(in.) (watts) (watts) (in. H2O) (cfm) (air watts)
2.500 755 1.66 768 1.6980 107.1341 21.3483
2.000 753 3.71 766 3.7949 101.8055 45.3390
1.750 748 5.87 761 6.0044 97.7049 68.8465
1.500 744 9.19 757 9.4004 88.6998 97.8511
1.375 737 11.44 750 11.7019 83.6217 114.8346
1.250 729 13.98 742 14.3000 76.3714 128.1638
1.125 719 17.3 731 17.6960 68.8672 143.0164
1.000 704 21.02 716 21.5012 59.8448 151.0033
0.875 681 25.12 693 25.6950 49.7649 150.0619
0.750 655 29.72 666 30.4003 39.7197 141.7041
0.625 626 34.41 637 35.1977 29.6375 122.4203
0.500 593 39.3 603 40.1996 20.1266 94.9488
0.375 556 43.5 566 44.4958 12.2060 63.7367
0.250 529 45.95 538 47.0019 5.9030 32.5601
0.000 510 48.2 519 49.3034 0.0000 0.0000
15
F820 − 21
TABLE X7.3
Measured Data Corrected Data (Data at Standard Conditions)
Orifice Input Input Power, Suction, Airflow, Air Power,
Suction
Diameter Power Ps hs Q AP
(in. H2O)
(in.) (watts) (watts) (in. H2O) (cfm) (air watts)
2.500 701 1.51 768 1.7026 107.2412 21.4281
2.000 699 3.37 766 3.7999 101.7847 45.3897
1.750 695 5.32 761 5.9987 97.5589 68.6790
1.500 691 8.34 757 9.4040 88.6285 97.8104
1.375 685 10.38 751 11.7043 83.5185 114.7164
1.250 677 12.68 742 14.2977 76.2585 127.9537
1.125 667 15.70 731 17.7030 68.7675 142.8659
1.000 654 19.07 717 21.5030 59.7434 150.7599
0.875 633 22.79 694 25.6976 49.7152 149.9267
0.750 608 26.96 666 30.3996 39.6695 141.5213
0.625 581 31.22 637 35.2031 29.5966 122.2699
0.500 550 35.65 603 40.1982 20.1050 94.8440
0.375 517 39.47 566 44.5056 12.1678 63.5515
0.250 491 41.68 538 46.9975 5.8739 32.3964
0.000 474 43.72 519 49.2978 0.0000 0.0000
watts (based on incorrect air density ratio Dr = 0.9790; using Bt X7.11 The test laboratory also recorded the equivalent mean
= 29.50, Tw = 61.0 °F, and Td = 71.0 °F). sea level barometric pressure value. This value was obtained
X7.8.1 Although the data was incorrect, the laboratory from a digital weather station within their laboratory that had
observed in their case that it does not make much difference in been originally set up to report the mean sea level equivalent
the results. This was due to the small difference between the barometric pressure to coincide with local weather reports. The
test station pressure and the equivalent mean sea level value value was 28.64 in. Hg and represented what the barometric
(the small difference was a result of the test laboratory only pressure would be at 0-ft elevation not at the test laboratories
being 355 ft above mean sea level). elevation of 3700 ft.
X7.8.2 It is also worth noting that had the test laboratory X7.12 The air density ratio, Dr, was computed using the
actually tested the vacuum cleaner under the 29.50 in. Hg values in X7.10 as follows:
barometric pressure, the measured suction and input power Dr = 17.68(24.86) – 0.001978(64.0)2 + 0.1064(64.0)
values would have been slightly different for the vacuum + 0.0024575(24.86)(80.0 – 64.0) – 2.741
cleaner. (80.0 + 459.7)
16
F820 − 21
REFERENCES
(1) “Calibration of ASTM Plenum Chamber,” Whirlpool Corp., 3/31/76. (4) “Fan Engineering,” Buffalo Forge Co., 1970.
(2) “ASHRAE Guide and Data Book—Handbook of Fundamentals,” (5) AGA-ASME Committee Report on Orifice Coefficients, 1935.
American Society of Heating, Refrigeration, and Air-conditioning (6) Sebok, A. L., “Simplified Air Density Correction of Vacuum Cleaner
Engineers, 345 E. 47th St., New York, NY 10017. Performance Data,” Institute of Electrical and Electronics Engineers
(3) “ASME Fluid Meters Theory and Application, 6th Ed.,” American Transactions, Vol IGA-6 January/February, 1970, pp. 88–94.
Society of Mechanical Engineers, 345 E. 47th St., New York, NY
10017, 1971.
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above