” button to view the recorded data downwards. Press the OK button to make the interface of whether to delete the current recorded data pop up. Select the “Yes” menu to delete it, and select the “No” menu to exit the interface. As shown below: in addition to displaying the recorded data, the bottom left corner displays the position and total number of it, and the bottom right comer displays the date and time of it. Press the ESC button to exit. 30UT8804E User Manual OE No. Description 1 View symbol 2 Recorded data 3 Position and total number of the recorded data 4 Date and time of the recorded data 31UT8804E User Manual UNI-T. 3) Delete all save Control the cursor to select the “Delete all save” menu, and press the F1 or OK button to make the interface of whether to delete pop up. Select the “Yes” menu to delete all the recorded data, and select the “No” menu to exit the interface. 4) Record Control the cursor to select the “Record” menu and press the F1 or OK button to confirm it. Before starting recording, control the cursor to select the following three options. © Record name Press the OK button to name the recording item. At this time, the background of the editing position is indicated by blue. Press the “<{" or “> " button to select the editing position, and press the F1 button to select the “Mode” menu (input mode: uppercase, lowercase, number or symbol). After confirming the mode, press the F2 or F3 button to modify the name. Press the OK button to confirm the naming, while press the F4 button to exit and cancel the current setting. © Record gap Press the OK button to set the continuous record gap. At this time, the background of the editing position is indicated by blue. Press the “ <4“ or“ " button to select the editing position, and press the F2 or F3 button to enter different numbers. The record gap can be set to 1Sec~60Min. Press the F1 or OK button to confirm the setting, while press the F4 button to exit and cancel the current setting 32T UT8804E User Manual UN ® Record duration Press the OK button to set the continuous record duration. At this time, the background of the editing position is indicated by blue. Press the “<4 " or “ B>" button to select the editing position, and press the F2 or F3 button to enter different numbers. Duration can be set for days, hours and minutes. The maximum duration is 99 days 23 hours and 59 minutes. Press the F1 or OK button to confirm the setting, while press the F4 button to exit and cancel the current setting After finishing the above settings, press the F1 button to select the “Start” menu to start continuous recording. As shown below, the “REC” symbol will be displayed on the screen and ‘the red dot will flash. The related display information is as follows: 33UT8804E User Manual =o) eee ae No. [_ Information Description 1_| Main display Displays real-time input values 2 | Number ofthe data _| Total number of the recorded events currently 3_| Elapsed time Displayed in hour: minute: second format 4 | Remaining time Record duration minus elapsed time, 5 displayed in hour: minute: second format 6 | Max value Records the max value of the measured data 7_|_ Mean value Records the mean value of the measured data 8 | Min value Records the min value of the measured data 9 | Record name Name of the current record Start Start time and date of the recording period To stop manually, press the OK button to make the interface of whether to stop recording pop up. Select the “Yes” menu by pressing the F2 button to stop recording data, while select the “No” menu by pressing the F4 button to exit the interface and continue recording 34UT8804E User Manual UNI-T. 5) View record Control the cursor to select the “View record” menu, and press the F1 or OK button to enter the view interface. The “ [EB] symbol will be displayed at the top right. The relevant basic information is as shown below: No. | Information Description 1_|_Name Name of the recorded event 2_| Max value Max value of this recorded data 3__| Mean value Mean value of the sum of this recorded data 4 | Min value Min value of this recorded data 5_| Number ofthe data_| Total number of this recorded event 6_|_Record gap interval time, displayed in minute: second format 7_| Record duration Actual duration after continuous recording stops 8 | REC Position and total number of this recorded event 9 | Start Start time and date of the recording period Press the “” button to move the cursor to the right. For each short press, the cursor moves one datum or one pixel to the right. For long press, the cursor accelerates to the right. Press the MENU button to make four types of menus (vertical magnification, vertical reduction, horizontal magnification and horizontal reduction) pop up. Press the F1 or F2 button to make the curve chart be zoomed vertically. Press the F3 or F4 button to make the curve chart be zoomed horizontally. Press the MENU button again to exit the menu. To delete this recorded event, press the OK button in the environment of tendency chart interface to make the interface of whether to delete this recorded event pop up. Select the “Yes” menu to delete this recorded event, while select the “No” menu to exit the interface. 6) Delete all record Control the cursor to select the “Delete all record” menu, and press the F1 or OK button to make the interface of whether to delete pop up. Select the “Yes” menu to delete all the recorded data, and select the “No” menu to exit the interface. 37UT8804E User Manual UNI-T. 19. Backlight Control If the light is not enough to see the display screen, long press the -Q: button for 1 second to switch the backlight brightness. 20. Settings Select the “Settings” menu to set and view the related information of the meter, and control the cursor to select the related information of the menu item below: 1) Language Select the “Setup” menu to make a small window pop up, which is indicated by blue background. Press the F2 or F3 button to select a different language, and press the F1 button to confirm the modification. Press the F4 button to exit the small window. 2) Button sound Select the “On” menu to turn on the button sound, and select the “Off” menu to turn off the button sound 3) Mis-insertion Alarm for Test Leads Select the "On" menu to turn on the mis-insertion alarm for test leads, and select the “Off’ menu to turn off the mis-insertion alarm for test leads. 4) Communication Transmission Select the "On" menu to turn on the communication transmission and the “==” symbol will be displayed at the top left. Select the "Off" menu to turn off the communication transmission and the * ===" symbol at the top left will be blanked 38T UT8804E User Manual UN 5) Time and Date Select the “Setup” menu to make the time and date editing window pop up. At this time, the background of the editing position is indicated by blue. Press the “4 "or “ > " button to select the editing position, and press the F2 or F3 button to enter different numbers. Press the F1 button to confirm the modification, while press the F4 button to exit the window. 6) Set dBm Reference Value Select the “Setup” menu, and press the F2 ("<€”) or F3 (" P ") button to scroll between the ten defined reference values (4, 8, 16, 25, 32, 50, 75, 600, 1000 and Modify). When selecting the "Modify" menu option, press the F2 or F3 button to modify the number and the “<” or “D>” button to select the editing position. Any reference impedance value from 49 to 12009 can be selected. Press the F1 button to confirm the modification. 7) Storage formatting Select the "Start" menu to make the formatting warming window pop up. Select the “Yes” menu to format the storage, and select the “No” menu to cancel the formatting and exit the window. 8) Factory Reset Select the "Reset" menu to make the factory reset warming window pop up. Select the "Yes" menu to restore factory settings, and select the “No” menu to cancel the factory reset and exit the window. 9) About the Meter Select the “About” menu to view the product model, version, serial number and available memory space. 39UT8804E User Manual Vill. Technical specifications Accuracy: + (% of reading + digits), 1 year warranty; if the ambient temperature changes by +5°C, the accuracy will not be used until 2 hours later. Ambient temperature: 23°C+5°C_ Ambient humidity: <75% RH Temperature coefficient: 0.1% (specified accuracy)/°C (<18°C or >28°C) UNI-T. 1. AC Voltage Range Resolution Accuracy 6omv 0.001mv 45 ~ 1kHz 1k ~ 10kKHz 10k ~ 20kHz 20k ~ 100kHz +(0.6%+60) £(1.2%+60) +(3%+60) +(4%+60) 45 ~ 1kHz 1k ~ 10kHz, 10k ~ 20kHz 20k ~ 100kHz Boomy | OOtmY 03% +30) =(12%+40) | #(8%+40) | #(4% +40) ev o.0001v 45 ~ 1kHz 1k ~ 10kHz_ 10k ~ 20kHz 20k ~ 100kHz (0.3% +30) =(1.2%+40) | £(3%+40) £(4%+40) 6ov ooo1v 45 ~ 1kHz 1k ~ 10kHz 10k ~ 20kHz 20k ~ 100kHz +(0.3%+30) £(1.2%+40) £(3%+40) +(4%+40) 45 ~ 1kHz 1k ~ 10kHz 10k ~ 20kHz 20k ~ 100kHz 800 o.oiv (0.4% +30) £(1.2%+40) | £(8%+40) For reference only 4000V ov 45 ~ 1kHz 1k ~ 5SkHz 5k ~ 10kHz 10k ~ 100kHz = (0.6%+30) £(8%+40) | £(6%+40) For reference only © Input impedance: About 10MQ * Overload protectio 1000V © Display: True RMS, applicable to 10% ~100% of the range 40UT8804E User Manual 2. DC Voltage Range Resolution Accuracy 60mvV 0.001mV +(0.025%+20) 600mV 0.01mV ev 0.0001V £(0.025%+5) 6ov 0.001V 600V 0.01V 4(0.003%+5) 1000V O1V © Input impedance: About 10MQ © Overload protection: 1000V © REL function should be used to compensate the bias for 60mV setting 41 UNI-T.UT8804E User Manual 3. AC Voltage+ DC Voltage UNI-T. Range Resolution Accuracy 50~1kHz 41k~10kHz 10k~35kHz 60mv 0.001mv +(1%+80) 4(3% +40) £(6%+40) 50~1kHz 1k~10kHz 10k~35kHz 600mVv 0.01mv +(1%+80) +£(3%+40) +(6%+40) 50~1kHz 1k~10kHz 10k~35kHz 6V 0.0001V +(1% +80) +(3%+40) +(6%+40) 50~1kHz 1k~10kHz 10k~35kHz 60v 0.001V. #(1% +80) +(3%+40) £(6%+40) 50~1kHz 1k~10kHz 10k~35kHz 600V 0.01V (1% +80) For reference only | For reference only 50~1kHz 1k~10kHz 10k~35kHz 1000V O.1V £(1.2% +80) For reference only For reference only ® Input impedance: About 10M. ® Overload protection: 1000V © Display: True RMS, applicable to 10% ~100% of the range 42UT8804E User Manual UNI-T. 4.AC Range Resolution ‘Accuracy 45~1kH, 1k~1OKH 600NA 0.01pA z iz +(0.6%+40) +(1.2%+40) 45~1kHz 1k~10kKHZ 6000p 0.1pA £(0.6%+20) (1.2% +40) 60mA 0.001mA. 45~1kHz 1k~10kHz ™ ™ ¥(0.6% +40) (1.2% +40) 600mA 0.01mA 45~1kHz 1k~10kHz ™ sot £(0.6%*20) 2(1.2%*40) 45~1kHz 1k~10kHz 20A 0.001A. +(1%+20) +(3%+40) © Display: True RMS, applicable to 10% ~100% of the range © Overload protection: A, mA range: 0.6 H 1000V fast-acting fuse (6x32mm) 10A range: 11AH 1000V fast-acting fuse (®10x38mm) © When the measured current is close to 20A, each measurement time should be less than 30s and the rest interval should be more than 10 minutes! 43UT8804E User Manual 5.DC Range Resolution Accuracy 600HA 0.01pA +(0.08%+20) 6000A 0.1pA +(0.08%+10) 60mA 0.001mA, +(0.08%+20) 600mA 0.01mA +(0.15%+10) 200 0.001 (0.5% +10) © Overload protection HA, mA range: 0.64 H 1000V fast-acting fuse (6x32mm) 10A range: 11A H 1000V fast-acting fuse (10x38mm) © When the measured current is close to 20, each measurement time should be less than 30s and the rest interval should be more than 10 minutes! 44UT8804E User Manual UNI-T. 6. AC+DC Range Resolution ‘Accuracy 50~1kHz 1k~10kHz 600pA 0.01pA +#(0.8%+40) +(2.0%+40) 50~1kHz 1k~10kHz 6000yA 0.1pA +#(0.8%+20) +£(2.0%+40) 50~1kHz 1k~10kHz 60mA 0.001mA, +(0.8%+40) +(2.0%+40) 50~1kHz 1k~10kHz 600mA 0.01mA +#(0.8%+20) +(2.0%+40) 50~1kHz 1k~10kHz 208 0.0018 +#(1.2%+20) +(3%+40) © Display: True RMS, applicable to 10% ~100% of the range © Overload protection pA, mA range: 0.6A H 1000V fast-acting fuse (6x32mm) 10A range: 11A H 1000V fast-acting fuse (10x38mm) ‘© When the measured current is close to 20A, each measurement time should be less than 30s and the rest interval should be more than 10 minutes! 45UT8804E User Manual 7. Resistance Range Resolution Accuracy 6000 0.010 In the REL state: +(0.05%+10) 6kQ 0.0001kQ 60kQ 0.001kO + (0. 05%+2) 600kQ 0.01k9 6MQ 0.0001MQ. + (0. 3%+10) 60MQ 0.001MQ + (2%+10) 8. Conductance Overload protection: 1000V ® The humidity should be <50% for 60MO setting. Range Resolution ‘Accuracy 60ns 0.01nS + (24410) Overload protection: 1000V © The humidity should be <50%. 46 UNI-T.UT8804E User Manual 9. Capacitance Range Resolution ‘Aecuracy nF 0.001 nF £(3%*10) 60nF O.01nF £(2.5%*5) 600nF O.inF uF 0.007 nF on 60uF O.OTuF #(2%+5) 600uF OA émF 1uF =(5%*5) 60mF Our Not specified ‘© Overload protection: 1000V ® Display: 6000 count 10. Temperature Range Resolution ‘Accuracy =40°C~40°C £(2.0%+30) 40°C~400°C 1c £(1.0%+30) 100°C~1000C 42.5% ~40°F~104°F #(2.5% +50) 104 F-752F VF E(1.5%50) 752 F-18632 F 22.5% Overload protection: 1000V Dual channel temperature measurement UNI-T. Temperature sensor: Point mode K-type thermocouple (only applicable to measuring temperature below 230 °C ) 47UT8804E User Manual UNI-T. 11. Frequency Range Resolution Accuracy 60Hz 0.001 Hz #(0.02%+8) 600Hz 0.01 Hz 6kHz 0.0001kHz 60kHz 0.001kHz (0.019448) 600kKHz 0.01kHz 6MHz 0.0001MHz 60MHz 0.001MHz © Overload protection: 1000V Input amplitude requirements: 10Hz~30MHz: 600mV=a=30Vrm >30MHz: Not specified 12. Duty Ratio Range Resolution Accuracy 10%~90% (10Hz~2kHz) | 0.01 #(1.2%#30) ® Overload protection: 1000V © Rise time: < us, the signal is centered on the triggering level 48UT8804E User Manual 13. Pulse Width UNI-T. Range Resolution Accuracy 250m $0.001mS~0.01mS (1.2% +30) © Rise time: < 1s, th © 10 Hz~200 kHz: Pul 14. Con’ © Overload protection: 1000V The pulse width range is determined by the frequency of the signal uity Measurement signal is centered on the triggering level. se width > 2us Range | Resolution Remark 1) 0.019 The OCV is about 3V; Short circuit alarm: If the resistance is <10Q, the buzzer goes off continuously; Ifthe resistance is >500, the buzzer does not go off. Open circuit alarm: If the resistance is >500, the buzzer goes, off continuously; If the resistance is <10Q, the buzzer does not go off. * Overload protection: 15. Diode Measurement : 1000V. Range | Resolution Remark >t 0. 0001V The OCV is about 3V and the measurable forward voltage drop value of the PN junction is about < 3V. When the buzzer is activated, short beep indicates the normality of the PN junction; continuous beep indicates the short circuit of the PN junction. The typical voltage of silicon PN junction is about 0.5 to 0.8 V. © Overload protection : 1000V. 49UT8804E User Manual IX. Maintenance 1. General Maintenance Clean the meter casing with a damp cloth and mild detergent regularly. Do not use abrasives, isopropyl alcohol or solvents. Dirt or moisture on the terminals will affect the readings and incorrectly activate the mis-insertion alarm. Please follow the steps below to clean the terminals: 1) Turn off the meter and remove all test leads. 2) Remove the dirt from the terminals. 3) Soak a clean cotton swab with mild detergent and water. Clean each terminal with the swab and dry it with canned compressed air to force the detergent and water out of the terminal. 4) If there is any malfunction, stop using the meter and send it for maintenance. 5) The calibration and maintenance must be implemented by qualified professionals or designated departments. 2. Power supply setting AX AC SELECTOR oO) | © 100V 120v 240v a (oy Co a 1) Flick the red selector to the corresponding position. 2) Four options (100V/120V/220V/240V) can be set. 50UT8804E User Manual 3. Fuse replacement 1) Switch off the power supply. 2) Open the fuse housing with a flathead screwdriver. 3) Replace the fuse with new one. The contents of this manual are subject to change without notice. 51UT8804E User Manual UNI-T. UNI-TREND TEGHNOLOGY (CHINA) CO.,LTD. No6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial Development Zone, Dongguan City, Guangdong Province, China Tel: (86-769) 8572 3888 http:/www.uni-trend.com 52 UNI