BECO INVERTER

Villa type A 250 m2


location
Area m2 Heat transfer AIR AIR CONDENTION
Amount CONDENTION (SPLIT) Capacity TON
(SPLIT) Capacity (practical)
TON
(theoretical)
Reception 36.8 low 2.3 2
living room 32.71 High 2.45325 2
bedroom 1 G 18.4 low 1.15 1
bedroom 2 1st 18.4 High 1.38 1
bedroom 3 1st 27.6 High 2.07 1.5
M.bedroom 4 1st 2.548+19.52=22.06 High 1.695 1.5

GENERAL SHKAR

Home type B 200m2


location
AREA m2 Heat transfer AIR AIR CONDENTION
Amount CONDENTION (SPLIT) Capacity TON
(SPLIT) Capacity (practical)
TON
(theoretical)
Reception 22 low 1.375 1.5
Hall 14.25+7.4=21.66 High 1.6245 1.5
bedroom G 19.2 low 1.2 1
bedroom 1st 26.13 High 1.95975 2
bedroom 1st 21.5 High 1.612 1.5
M.bedroom G 19.35 low 1.209375 1

BECO INVERTER

Home type D 200m2


Location
AREA m2 Heat transfer AIR CONDENTION AIR CONDENTION (SPLIT)
Amount (SPLIT) Capacity TON Capacity TON
(theoretical) (practical)

Reception 25.2 low 1.575 1.5

living room 36.4 High 2.73 2

bedroom 1 G 18.8 low 1.175 1

bedroom 2 1st 10 High 0.75 1

bedroom 3 1st 21.84 High 1.638 1.5

M.bedroom 4 1st 25.2 High 1.89 1.5

Note that the ceiling height of the room was imposed 3 meters
Note the coefficient of 300 is used for the high amount of heat transfer
Note the coefficient of 250 is used for the low amount of heat transfer
Air conditioning unit capacity = coefficient * room area * ceiling height