You are on page 1of 8
Installation Instructions ww FLEX 1/0 Generic Spring Clamp Terminal Base (Cat. No. 1794-TB3GS) opaaapagenaaaEe BABAR: 8 SOOO ‘Component identification Female flexbus connector Terminal base unit Male flexbus connector Keyswitch - Set to the position required for the installed module Mounting holes for pane! mounting 6, 7, | Inputloutput terminal strips for connecting inputloutput wiring '8 | commons, power connections, customer power suppl 9 | Locking tab 10 | Module locking latch 11_| Cover plug or male flexbus connector inputfoutput hassis grounds FLEX Vis a trademark of Alen-Bradley Co. In. Publication 1794-5.59 ~ March 1998 2 __ FLEX /0 Generic Spring Clamp Terminal Base European Union Directive Compliance If this product has the CE mark it is approved for installation within the European Union or EEA regions. It has been designed and tested to meet the following directives, EMC Directive This product is tested to meet Council Directive 89/336/EEC Electromagnetic Compatibility (EMC) and the following standards, in whole or in part, documented in a technical construction file: © EN 50081-2 EMC — Generic Emission Standard, Part 2 ~ Industrial Environment © EN 500822 EMC ~ Generic Immunity Standard, Part 2 Industrial Environment ‘This product is intended for use in an industrial environment. Low Voltage Directive This product is tested to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN 6131-2 Programmable Controllers, Part 2 - Equipment Requirements and Tests. For specific information required by EN 61131-2, see the appropriate sections in this publication, as well as the following Allen-Bradley publications: © Industrial Automation Wiring and Grounding Guidelines for Noise Immunity, publication 1770-4.1 © Automation Systems Catalog, publication BILL ‘This equipment is classified as open equipment and must be mounted in an enclosure during operation to provide safety protect Description ‘The 1794-TB3GS terminal base has 36 wiring connections to/from a plug-in module. The use of each terminal depends on the module mounted in this base. The 1794-TB3GS terminal base has connections for cold junction compensation and terminals designated for shield termination to chassis, ground. Publication 1794-5.59 ~ March 1998 FLEX 1/0 Generic Spring Clamp Terminal Baso 3 ATTENTION: The wiring on this base unit is different from other terminal base units in FLEX 1/0. Make certain that connections are correct before applying power. Wiring Connections for Terminal Base 1794-TB3GS_ ote ee S PTE UH NR DHS Row A w7k pom 2am se ve wee ness | poWD lease ree wane cH 6 7 wo 8 25 | RG Label placed at top of wiring area. 4 O BE AAl|ms 8 ‘VCOM, Chassis L_ _ Chassis. ++VCOM, Gnd God ‘Chassis Ground 2aV do supply for Shields ‘Supply Out 23985 nd nd To connect wiring, insert a blade-type screwdriver with a blade width of 0.100-0.120in, (2.54-3,05mm) into the slot above the selected wiring port and lift up, Insert the wire while holding the screwdriver up. Release the upward screwdriver pressure to secure the wire. Mounting on a DIN Rail unit when power is applied. Interruption of the flexbus can ATTENTION: Do not remove or replace a terminal base L f \. result in unintended operation or machine motion. 4. Remove the cover plug (if used) in the male connector of the unit to which you are connecting this terminal base unit, Publication 1794-5.59 - March 1998 4 FLEX I/O Generic Spring Clamp Terminal Base 2, Check to make sure that the 16 pins in the male connector on the adjacent device are straight and in line so that the mating female connector on this terminal base unit will mate correctly. 3. Make certain that the female flexbus connector C is fully retracted into the base unit, 4. Position the terminal base on the 35 x 7.5mm DIN rail A (A.B pt. no. 199-DR1). Position terminal base at a slight angle and hhooked over the top of the DIN rail A. Slide the terminal base unit over tight against the adapter. Make sure the hook B on the terminal base slides under the edge of the adapter and the flexbus connector is fully retracted. Publication 1794-5.59 ~ March 1998 FLEX 1/0 Generic Spring Clamp Terminal Baso 5 ATTENTION: Do not force the terminal base into the A adjacent base/adapter. Forcing the units together can bend or break the hook and allow the units to separate and break ‘communication over the backplane. 5. Rotate the terminal base onto the DIN rail with the top of the rai hooked under the lip on the rear of the terminal base. Use caution to make sure that the female flexbus connector does not strike any of the pins in the mating male connector. 2 Press down on the terminal base unt to lock the terminal base on the DIN rail. It the terminal base does not lock into place, use a screwdriver or similar device to open the locking tab, press down on the terminal base until flush with the DIN rail and release the locking tab to lock the base in place. Gently push the flexbus connector into the side of the adapter to complete the backplane connection. 6. For specific wiring information, refer to the installation instructions for the module you are installing in this terminal base unit, 7. Repeat the above steps to install the next terminal base. Publication 1794-5.59 ~ March 1998 6 _ FLEX 1/0 Generic Spring Clamp Terminal Base Wiring ATTENTION: Total current draw through the terminal base unit is limited to 10A. Separate power connections may be necessary. Daisy-chaining Tramscne || Tomancie || Tamacaste |{_Temerone etasoptitia || orhesgicsie | ermacquale [farang uesae Note: Al modules must be analog modules fortis configuration, Wiring when total current draw is less than 10A Tremere — th thst crvel Nos Teme orto Trance ernie 2a de 2avee Note: Use this configuration using any “noisy” dc digital /O modules in your system. ‘Themocuplo Mode ig spuaetom ie wos 19 when total current draw is greater than 108. Combination Taree || Tiemane |] toperar whedon taste) ortacgicste |) etrarqusaie |) orhndng eae 26 de avec ‘Note: Al modules powered by the same power supply ‘must be analog modules fortis configuration Tolal current draw through any base unit must not be greater than 10A Publication 1794-5.59 ~ March 1998 7 FLEX JO Generic Spring Clamp Terminal Base ‘uaysod jequozu0y 1) 2164 unseayy u seaiBap 121) 9 seaifen os poooxs yoursn XY sod fue u pounow vaya anu woee no} 52) °F melody Buziadg =D dn atepe win cae soysod Bunurau_, | weiNia= Teauen 9} 8H pj Buyunow euogdo 20} suosuewp afoy Bununoy = Y VA -wwoog Avan hrewproudde yes nig anos cd (59 x nex ite) (ee x mye x uve) (ga x gg x 28) PexMe' Geexmesxnee Geexmeaxts 1 aeexMeexuis | ; obexmens DeaLy6LL i ‘SOeaL-P6Lt | | Publication 1794-5.59 - March 1998 8 _ FLEX 1/0 Generic Spring Clamp Terminal Base 1794-TB3GS Specifications Number of Terminals Trowat 16 2rows of 18 Terminal Type Spring type clamp - To open, insert bladed screwdriver (0.100-0.120in/2.54-3,05mm wide) into slot and it up. Dimensions (with module installed inbase) Inches 8.74 x3.7Wx27D {Milimeters) (94H x 94W x 690) Current Capacity 0A maximum Voltage Rating ‘1.2 ac maximum Isolation Voltage Chane! to-channel isolation determined by serted module Environmental Conditions Operational Temperature Oto 55°C (82 t0 1319F) ‘Storage Temperature 40 to 85°C (~40 to 185°F) Relative Humidity 5 to 95% noncondensing Shock Operating ‘80 g peak acceleration, 11(+1)ms pulse width Non-operating | 50g peak acceleration, 11(+1)ms pulse width Vibration Tested 5 g @ 10-500H2 per IEC 68-2-6 Conductors Wire Size {2 gauge (4mm?) stranded maximum 23/64 inch (1.2mm) insulation maximum Category! Category is dependent upon installed module, ‘Agency Ceriication = CSAcetiied (When products marked) CSA Class |, Division 2, Groups A,B, C, D certified * ULiisted ‘© CE marked for all applicable You use this conductor category information for planning conductor rowing, Refer to publication 1770-4.1,"Industial Aulomation Wiring and Grounding Guidelines for Noise Immunity.” @8 Rockawelll Automation Allen-Bradley With major otic 00S World Headquarters, Allen-Bradley 1201 South Second Street Milwaukee, WI 53204 USA Tek (1) 414 382-2000 Fax: (1) 414 982-4444 'pupication 1794 5.59 - March 1998 PN955132-01 Spf bles 9458-637 opi 108 Aen ay Conny Pin USA

You might also like