You are on page 1of 8
THE NEW WATER SOFTENER SOFT-M Quick installation instruction manual WATER SOFTENER facking specification Name Quantity Water softener machine pes transformer 4pes Certificate of qualification, warranty card tpes Manual instruction of valve 1pes Spare | Bypass valve faucet 2pes parts | ops 2pes 1/2" drain pipe (with pipe clamp) 1set Quick installation instruction manual 1pos reducing valve 4pes DE Seas) 1. The equipments siricly prohibited to tilt or horizontal in the process of transportation, installation and use. 2, The floor where the equipments installed should be smooth, bearing capacity should be greater than 300 kg/square meter, and should have AC power supply, inlet and outletwater interface, sewage pipe and floor crain. 3. Donnot install the equipment near acid or alkaline substances or gases, so as not to damage the equipment As corrosion. 4, 220V/ 50HZ single-phase AC power supply must be used, other power supply is strictly prohibited. The socket must have Reliable ground wire can only be used 5. The equipment shall be installed indoors. Ifitis needed to be installed outdoors, the body and pipes must be protected Temperature anti-freezing measures, and also sunscreen waterproof, 6. The best inlet water pressure is required to be 0.15~0.6Mpa. Ifitis lower or higher than this standard, a booster pump should be installed And pressure reducing valve to ensure that the working pressure of the equipment meets the technical requirements. 7. The drainage of the sewer must be smooth, and there mustbe an air gap between the sevage pipe and the sewage. Do not seal the drain pipe and the drain pipe connection, in case the vacuum negative pressure caused by the controller can not workOr sewage backflow inta the system. 6 WATER SOFTENER BES rer W. Remove the top cover A\ Note: When removing, pay attention to the buckle on both sides to prevent damage Z. Connect the inlet and outlet water pipes (1) screw the bellows into the bypass water pipe connector —- (Main ACen A\ Note: the sealing gasket should be placed and tightened to prevent leakage of the joint O° WATER SOFTENER (2) Then insert the bypass water pipe connector into the bypass, and insert the large insert outlet pipe —s —_—— al inlet pipe - A\ Note: the joints and inserts should be installed in place, and the direction of the inlet and outlet pipes should be corresponding 8. Connect pressure reducing valve (1) the two bellows are screwed into both ends of the pressure reducing valve {CMa =n) IE A\ Note: the sealing gasket should be placed and tightened to prevent leakage of the joint (2) connect the bellows at the outlet end of the pressure reducing valve with the inlet end of the water softener, and the bellows at the inlet end with Inlet water pipe connection inlet pipe A\ Note: Install the inlet water line as indicated by the arrow on the pressure relief valve 3 Q2_WATER SOFTENER *. Connect drain line and overflow port (1) loosen the pipe clamp and insert it into the pre-connecting hose (2) Then insert the hose into the sewage outlet, the overflow outlet to the bottom, and finally move the pipe clamp to the hose and The junction of sewage outlet and overflow outlet should be tightened C Installation drawing f overtow port NN : A\ Note: the position of the control valve should be higher than the floor drain, and the length of the sewage pipe and overflow pipe should be limited to within 2 meters and placed above the floor drain. Do not install any cut on the discharge line flow unit, Separate supports must be provided between each pipeline system to avoid control valves damage or leakage due to gravity or stress from pipes. A\ Note: There must be a gap between the drain line and the sewage , to prevent negative pressure from causing control device not working or sewage backflow system. Blowdown and overflow lines must be secured with straps (ensure to avoid water pressure in the customer's home when higher, flush the hose off or outthe drain ) o WATER SOFTENER ®. Puton top cover Button the cover into the barrel. See! 6. Add salt (1) Open the lid up (2) Pour softening salt into the barrel (3) Cover the lid N\ BP x > ‘ > A\ Note: reuse salt, salt surface should be up to 2/3 of the height of the salt tank. (hint: salt dissolution time not less than 6 hours to ensure that the salt solution is saturated) 7. General installation diagram salt Reducing valve. Overflow pipe. Drainage pipe * Water softener Power supply Pressure gauge. ap Inlet pipe % _J Outlet pipe & Drainage pipe. 5 o WATER SOFTENER CELE Cail) W. Time setting When the power is switched on, “1 2:1 2" flashes on the screen , Press key orkey @)adjustable the number of hours; Press the key again, the number of minutes "1 2" flashes, press the key@)or the key (®) canbe adjusted the clock number; Press the key @)again, modify the current time successfully, press key &) return, enter the water supply state. 7. Back flush (1) Press the key ©) to adjust the control valve to the backwash state, and slowly open the inlet knob to 1/4 position (quick opening will likely cause damage to equipment and loss of resin), should initially be drained pipes hear slow air discharge. Wait until the airin the resin tank is completely discharged (drain pipe the discharge water starts to stabilize) , and then fully turn on the water inlet knob. (2) Blowdown until the discharged water is clean. (3) Turn off the water and let the equipment stabilize for 5 minutes so that the air in the tank can be completely drained. 8. The filling water (1) after adding water in the resin tank, itis necessary to fill the salt tank with water (artificial pouring of tap water is prohibited, because it may be affect the function of the salt valve), manually press the key ©) to adjust the control valve to the position of filling water, complete replenish water step, make the salt tank replenish the recycled water. (2) the first water must be lower than the salt surface in the salt tank, popularly speaking: the salt tank to see the salt water breakthrough.On weekdays, you should always be able to see crystal block grain salt (do not use fine salt) Please buy regular soft water special salt from local dealers. &. Rinse Press the key @)to finish the water replenishing, and the control valve will turn to the forward washing position for forward washing (removing the resin layer residual brine, while horizontally pressing the resin layer to achieve the best softening effect). ©. Water supply Press the key @) to end the forward washing, the control valve turns to the water supply position, and the machine starts making water. 6 O° WATER SOFTENER \€- Incase of equipment failure or other special circumstances, the bypass valve can be adjusted to the straight-through position, you can temporarily when the use of municipal water supply, to troubleshoot or solve the problem, and then adjust the bypass valve to soften state position to restore softened water supply . EEC rr Ci 3X In order to ensure the normal use of the product after installation, please have professional installation or maintenance personnel before use confirmation. 3% Avoid placing the device near a heat source or taking necessary heat-proof measures, and do not put itin the hot water pipeline and the pipes that produce hot water backilow.ltis strictly prohibited to use in the temperature below 5°C. please pay attention to anti-freezing to avoid the resin freezing crack damage failure 3 During the operation of the equipment, users should pay attention to check the salt content in the salt tank regularly and add salt each time regenerating salt to raise the salt level above the water surface;When the salt level is lower than 1/3 of the water level, please supplement salt for regeneration in time. 3X The equipment should use the purity of more than 99% of the regeneration of special salt, prohibited use contains additive class and large grain crystal block coarse salt. 3X Please use it in the range of water temperature 5~38'C and water pressure 0.15~ 0.6m Pa this product, outside the scope of the use of this product failure does not ‘occur It is covered by our liability and warranty. 3% The sodium used in the water treatment softening process is considered to be in table salt part of that, if you are a sodium limit drinker, is in drinking water the end is equipped with purification equipment. t \ 3% When the equipment is out of use for a long time or \ the local water pressure is unstable, be sure to close the feed water main valve off water power,The user shall be immediately prior to re-use carry out a manual regeneration operation to ensure the quality of the softened effluent. ‘ \, ® 3& Water hammer phenomenon should be prevented during the operation of the equipment and should be avoided as far as possible Quick full opening or full closing of the valve and start and stop the pump and other similar operations. 7

You might also like