Rockwell logo Automation Listen Think signs Center Get Support v Training & Webinars Online Forum Mpckwell.kb... logo TechConnect Customer Care v ID: QA1888 | Access Levels: TechConnect RSLogix/Studio 5000: Message instruction Path in ControlLogix READ LATER: §% Emailthispage @& Print Tofind an answer using.a previous Answer |D, click here Search Knowledgebase... SEARCH ADD TO FAVORITES Document iD AIB8B Published Date 10/02/2020 Summary RSLogix/Studio 5000: Message instruction Path in ControlLogix Question How do | create the Path in RSLogix/Studio 5000 for a message instruction (MSG) from a ControlLogix controller to.a ControlLogix controller using Ethernet ? Environment RSLogix 5000 © Studio 5000 Logix Designer Answer This describes how to create the correct path for a MSG instruction from a ControlLogix processor to another ControlLogix processor using Ethernet with two Ethernet cards (for example 1758-ENBI). The controller that initiates the message has the following path (separated by commas, no spaces): 1,51, 2, xxx. yyy.22z.www, 1,52 Where: * 1is the backplane for the first chassis (the ControlLogix backplane always uses 1) © Slis the slot of the 1756-ENBT in the first chassis (the first position on the left is 0, second |...) © 2is to go through the front port on to the Ethernet (always 2) © Xxx.yyy.2zz.www is the IP address of the 1756-ENBT in the second chassis © 1is the backplane for the second chassis (always 1 for ControlLogix) © §2is the slot of the ControlLogix in the second chassis (starting from left the first position is 0, second 1...) Example: 13,2,192.168.1.4,,0 No getting online with controller, it does not have to be) it can be browsed to while building the communication the Ethernet Module is in the 1/0 tree ( not necessarily, for the purpose of message communication or path. The module name will replace the 1,81 part of the communication path. Attachments Was this answer helpful? O Yes O No Recently Viewed CIP Generic MSG How to define the Path example from Logix Ethernet Message for a Logix Controller controller toa from CompactLogix to MSG to a 1761-Net- MicroLogix 1100/1400, ControlLogix Eniw SLC 5/05 or PLC-5/E DISCLAIMER This knowledge base web site is intended to provide general technical information on a particular subject or subjects and is not an exhaustive treatment of such subjects. Accordingly, the information in this web site is not intended to constitute application, design, software or other professional engineering advice or services. Before making any decision or taking any action, which might affect your equipment, you should consult a qualified professional advisor ROCKWELL AUTOMATION DOES NOT WARRANT THE COMPLETENESS, TIMELINESS OR ACCURACY OF ANY OF THE DATA CONTAINED IN THIS WEB SITE AND MAY MAKE CHANGES THERETO AT ANY TIME IN ITS SOLE DISCRETION WITHOUT NOTICE. FURTHER, ALL INFORMATION CONVEYED HEREBY IS PROVIDED TO USERS "AS IS.” IN NO EVENT ‘SHALL ROCKWELL BE LIABLE FOR ANY DAMAGES OF ANY KIND INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS PROFIT OR DAMAGE, EVEN IF ROCKWELL AUTOMATION HAVE BEEN ADVISED ON THE POSSIBILITY OF SUCH DAMAGES. ROCKWELL AUTOMATION DISCLAIMS ALL WARRANTIES WHETHER EXPRESSED OR IMPLIED IN RESPECT OF THE INFORMATION (INCLUDING SOFTWARE) PROVIDED HEREBY, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR ‘A PARTICULAR PURPOSE, MERCHANTABILITY, AND NON-INFRINGEMENT. Note that certain jurisdictions do not countenance the exclusion of implied warranties; thus, this disclaimer may not apply to you www.rockwellautomation.com Copyright © 2021 Rockwell Automation, Ine. Al Rights Reserved,

You might also like