You are on page 1of 1

LEGEND:

NOT TO SCALE

GENERAL NOTES
..\..\..\Documents\hikvision monitor.jpg

..\..\..\Documents\hikvision monitor.jpg

..\..\..\Documents\hikvision monitor.jpg
- MONITOR - SINGLE MAGNETIC LOCK
(1581VDB SDC 1580 SERIES)
- THE COMPONENTS FROM THE LOWER GROUND AND
- ELECTRIC STRIKE
GROUND FLOOR ARE CONNECTED IN ONE SWITCH ..\..\..\Documents\hikvision monitor.jpg

DS-K2700
ACCESS CONTROL
- MAIN SERVER (DS-K2700) (DS-K4G100 - Pro
Series)
LOCATED AT THE ELECTRICAL TECHNOLOGY SHOP 1 EMERGENCY
DOOR RELEASE

Emergency Break Glass


PRESS HERE PRESS HERE
- DOOR RELEASE
(DS-K7PEB)
ROOM, GROUND FLOOR. - SWITCH (DS-3E2326P)
No Touch

- PUSH BUTTON
- THE SWITCHES ARE ALL CONNECTED IN A MAIN
EXIT

(DS-K7P03)
..\..\..\Documents\control panel.png ..\..\..\Documents\control panel.png
- DOOR CONTROL PANEL - CARD READER
SERVER LOCATED AT THE SECOND FLOOR (DS-K2604T Four-Door)
..\..\..\Documents\screen 2.png
(DS-K1102AM)

SPECIFICALLY IN THE OFFICE. - COMBINATIONAL CARD READER,


ESC OK

1 2
ABC
3
DEF

4
GHI
5
JKL
6
MNO

7
PQRS
8
TUV
9
WXYZ
0

KEYPAD, AND BIOMETRIC


..\..\..\Documents\control panel.png ..\..\..\Documents\control panel.png
- DOOR CONTROL PANEL (DS-K1T8003MF)
(DS-K2602T Two-Door)
..\..\..\Documents\Screen.png

- COMBINATIONAL FACE RECOGNATION


IN OUT CH1 CH2 CH3 CH4 CH5 CH6
MAX
10W
WITH BIOMETRIC
POWER DS-KAD706

RESET
- RS-485 ETHERNET
LAN
IN OUT CH1 CH2 CH3 CH4 CH5 CH6
+ - !
24 VDC CONVERTER (DS-KAD706)

MAX
10W
MAX
10W IN OUT CH1 CH2 CH3 CH4 CH5 CH6

IN OUT CH1 CH2 CH3 CH4 CH5 CH6

POWER DS-KAD706
POWER DS-KAD706

RESET
RESET

IN OUT CH1 CH2 CH3 CH4 CH5 CH6 + - !


IN OUT CH1 CH2 CH3 CH4 CH5 CH6 + - ! LAN 24 VDC
LAN 24 VDC

MAX
10W
IN OUT CH1 CH2 CH3 CH4 CH5 CH6

POWER DS-KAD706

RESET

IN OUT CH1 CH2 CH3 CH4 CH5 CH6 + - !


LAN 24 VDC

..\..\..\Documents\control panel.png ..\..\..\Documents\control panel.png ..\..\..\Documents\control panel.png ..\..\..\Documents\control panel.png

..\..\..\Documents\control panel.png ..\..\..\Documents\control panel.png

EMERGENCY
DOOR RELEASE
No Touch No Touch
EMERGENCY
Emergency Break Glass
DOOR RELEASE
PRESS HERE

No Touch
EMERGENCY No Touch
DOOR RELEASE EMERGENCY No Touch Emergency Break Glass
..\..\..\Documents\screen 2.png DOOR RELEASE
EMERGENCY PRESS HERE PRESS HERE
EMERGENCY
No Touch DOOR RELEASE No Touch EMERGENCY
..\..\..\Documents\screen 2.png ..\..\..\Documents\screen 2.png
EXIT EXIT
DOOR RELEASE DOOR RELEASE Emergency Break Glass
Emergency Break Glass
EMERGENCY PRESS HERE PRESS HERE
..\..\..\Documents\screen 2.png

Emergency Break Glass


DOOR RELEASE No Touch ESC OK
ESC OK PRESS HERE PRESS HERE
ESC OK
Emergency Break Glass
PRESS HERE PRESS HERE ..\..\..\Documents\screen 2.png Emergency Break Glass
EXIT EXIT
PRESS HERE PRESS HERE PRESS HERE PRESS HERE
1 2 3 EXIT
Emergency Break Glass ABC
ESC OK
1 2
ABC
3
DEF
DEF
1 2
ABC
3
DEF

EXIT EXIT PRESS HERE PRESS HERE

ESC OK 4 5 6
4
GHI
5
JKL
6
MNO
4 5 6
GHI JKL MNO GHI JKL MNO
1 2
ABC
3
DEF 7 8 9 0
5 6
EXIT 7
PQRS
8
TUV
9
WXYZ 0
PQRS TUV WXYZ
7
PQRS
8
TUV
9
WXYZ 0
4 2 3
GHI JKL MNO 1 ABC DEF

7
PQRS
8
TUV
9
WXYZ 0 4 5 6
GHI JKL MNO

7
PQRS
8
TUV
9
WXYZ 0

ACCOUNTING OFFICE STOCK ROOM REGISTRAR 1 REGISTRAR 2 REGISTRAR 3 REGISTRAR 4 UNKNOWN DOORS

THREE STOREY BATSTATEU STUDENT CENTER BUILDING


N
SECOND FLOOR MOUNTING DIAGRAM
W E
SCALE: 1:100 M
S

ARCHITECT/CIVIL ENGINEER SHEET CONTENT SHEET NO.


SEAL PROJECT / LOCATION: OWNER DESIGNED:

SQUADRON MONITORING FUNDAMERA, BIANCA LOUISE S. THREE STOREY BATSTATEU STUDENT BATANGAS STATE UNIVERSITY DRAWN/CAD:
AS-BUILT PLAN A
C:\Users\james\OneDrive\Documents\Academics\3rd Year - 1st Sem\ECEE 401 - ECE Elective 1\Outputs\GROUP 4- COMPANY LOGO.png

INGCO, JERIC L. CENTER BUILDING


INCORPORATED MANIPOL, JOHN AERON CHECKED:
UPPER GROUND FLOOR PLAN
2/4
BatstateU Alangilan Campus DR. TIRSO A. RONQUILLO
PRC Reg No. Valid until: TIN:
Golden Country, Alangilan, Batangas City UNIVERSITY PRESIDENT DATE:
PTR No. Issued on: Issued at: