You are on page 1of 1

KEY PLAN :

ZAYED ROAD BIN


AM

AMMED
MA
NS

ROAD AN AL
R OAD TR
EE
MA
LE
TUNIS T HA

SHEIKH MOH
ST

MD
RE
ET

BIN HA
AL K
HAW
ANEE

NAHYAN
J RO

ZAYED
AD

D
SHEIKH

A
RO
2820323

DI
AR

AD
D5
AM

RO
0
AL

ES
AL A

AT
WIR

IR
R OAD

EM
NOTES
2820210
0

1. ALL DIMENSIONS ARE IN METERS UNLESS


W 30

STATED OTHERWISE NOTED.


2. COORDINATES ARE AS PER DLTM.
3. COVER LEVELS FOR MANHOLES AND CHAMBERS
TO BE VERIFIED AT SITE AS PER SITE CONDITION

LEGEND
2820312
EXISTING ROAD
PROJECT BOUNDARY
0

2820357 RIGHT OF WAY


30
W

PLOTS BOUNDARY

EXISTING STEEL SLEEVE PROPOSED ROAD


PROTECTION
PROPOSED UPSTAND CURB
W300 PROPOSED FLUSH CURB
W300

=
= PROPOSED SIDE WALK

=
= = = =

=
= = = = = = =
PROPOSED ROAD (INTERLOCK)

PROPOSED PARKING (INTERLOCK)


ROAD UNDER CONSTRUCTION
AL AMARDI STREET UNDER R1006
SIDEWALK UNDER CONSTRUCTION
UNDER R1006
EXISTING KERB
W600
W600 EXISTING HEEL KERB
BV W600
EXISTING SERVICE
W600 ROAD & CAR PARKING
PW300 PW300 (BY OTHERS) PW300 (BY OTHERS) PW300 EXISTING SIDE WALK
(BY OTHERS) PLANTS
BE LOCAL
(BY OTHERS)
LIMIT OF CONSTRUCTION
APING MUST

EXISTING Ø32mm WATER HOUSE


25% OF LANDSC

L.O.C.

HT-3
EXISTING Ø150mm uPVC DUCT TO BE CONNECTION TO BE RELOCATED
EXTENDED OUTSIDE ASPHALT AREA OUTSIDE PROPOSED ASPHALT EXISTING Ø150 uPVC DUCT
EXISTING Ø600mm WATER PIPE TO
BE PROTECTED BY STEEL SLEEVE PROPOSED uPVC DUCT EXTENSION
PROPOSED Ø300mm WATER
WITH GROUTING AND Ø150 uPVC

HT-2
PIPE TO BE PROTECTED BY
DUCT TO BE PROVIDED STEEL SLEEVE (BY OTHERS)
RS)

EXISTING Ø150mm uPVC DUCT TO BE ADNOC

FEMALE.WC
OTHE

MALE.WC
EXTENDED OUTSIDE ASPHALT AREA
PETROL STATION PROPOSED Ø225mm WATER
PIPE TO BE PROTECTED BY
5 (BY

)
Y OTHERS
STEEL SLEEVE (BY OTHERS)

)
PW22

Y OTHERS
ATM
MALE H.C
TOILET
H.C
TOILET
FEMALE

PW225 (B
2710296

REFRIGERATOR

REFRIGERATOR
2-DOOR

REFRIGERATOR
2-DOOR

2-DOOR

OVEN
AL AMARDI

PW225 (B
SHOPPING CENTER
X:\Projects\305-01 Magrudy_ADNOC Access Design\4. Drawings\4.3 Final Design\Rev. 0\4.3.5 Wet Services\4.3.5.4 Water\FD-1600-01.dwg sirosh

FHC

MAN HOLE

MAN HOLE
PUMP

TANK,HEIGHT
DOMESTIC

22.95 CU.M
WATER

3.25M
TANK , HEIGHT
FIRE WATER

22.95 CU.M

TANK , HEIGHT
FIRE WATER
3.25M

22.95 CU.M

TANK , HEIGHT
FIRE WATER
3.25M

22.95 CU.M
3.25M
0 16/06/2022 FINAL DESIGN AEC AH WA

UP

ONLY)
HT-1

ENT.
(SMALL VEHICLES
REV. DATE REVISION DRAWN CHECKED APPROVED

EXIT
DESCRIPTION BY: BY: BY:

WATER NETWORK LINE STYLE WATER NETWORK LEGEND PROPOSED Ø225mm WATER PIPE TO STATUS:

LEGEND : GV
OPEN GATE VALVE B CONSUMER BULK METER
BE PROTECTED BY STEEL SLEEVE FINAL DESIGN
PIPE DIA. IN SERVICE PROPOSED ABANDONED REMOVED PRO. REMOVAL
M (BY OTHERS)
1200mm W1200 PW1200 AW1200 RW1200 PRW1200 GV CLIENT:
W900 PW900 AW900 RW900
HALF-CLOSED GATE VALVE C
M COMBINATION METER
900mm PRW900
700mm W700 PW700 AW700 RW700 PRW700 GV
600mm W600 PW600 AW600 RW600 PRW600 CLOSED GATE VALVE F
M SYSTEM FLOW METER
550mm W550 PW550 AW550 RW550 PRW550 BV
500mm W500 PW500 AW500 RW500 PRW500 BUTTERFLY VALVE CLOSED FILLING POINT
450mm W450 PW450 AW450 RW450 PRW450 BV
400mm W400 PW400 AW400 RW400 PRW400 BUTTERFLY VALVE OPEN SAMPLING POINT
350mm W350 PW350 AW350 RW350 PRW350
300mm
250mm
W300
W250
PW300
PW250
AW300
AW250
RW300
RW250
PRW300
PRW250
WO WASHOUT VALVE P.G PRESSURE GAUGE
2710299
225mm W225 PW225 AW225 RW225 PRW225 SINGLE AIR VALVE DISINFECTION PLANT
200mm W200 PW200 AW200 RW200 PRW200
DP
ROADS & INFRASTRUCTURE CONSULTANT:
150mm W150 PW150 AW150 RW150 PRW150 DOUBLE AIR VALVE CL2 CHLORINE ANALYZER
100mm W100 PW100 AW100 RW100 PRW100
80mm W80 PW80 AW80 RW80 PRW80
PW75 AW75
NON RETURN VALVE WELL
75mm W75 RW75 PRW75

PW225
62mm

PW225
PR PRESSURE REDUCER VALVE PUMP
50mm
32mm
25mm
BALL VALVE NODE

REDUCER REMOTE TERMINAL UNIT


MOV
R.T.U
PROJECT NAME:
MOTORIZED BUTTERFLY VALVE T.X TEMPERATURE TRANSMITTER
ADNOC PETROL STATION & AL
PW225

ABBREVIATIONS :
END CAP
T.P = TOP OF PIPE
150Ø
P.X PRESSURE TRANSMITTER
AMARDI SHOPPING CENTER
F.R.L = FINISH ROAD LEVEL NEW DUCT

PROPOSED PIPE CROSSING THROUGH STEEL SLEEVE WITH


F.X FLOW TRANSMITTER ACCESS DESIGN ON
COMMON TAPPING 2710270
ANNULUS GROUTED TO BE PROVIDED FOR LINES FALLEN
UNDER ROAD
SINGLE TAPPING
EXISTING WATER CHAMBER PLOT # 2710299
2710295 DRAWING TITLE:
THRUST BLOCK
S
M CONSUMER STANDARD METER

EXISTING AND PROPOSED


DEWA WATER
NETWORK LAYOUT
6/17/2022 11:11 AM

PROJECT NO: DRAWING NO:


305-001 FD--1600-01
0 10 20 40 60 80 100m
mPRP

DATE: SCALE: REVISION:


1 : 1000 (A1)
JUNE 2022 1 : 2000 (A3) 0