You are on page 1of 7

Integrated management IS-QM-15-01 How To Manual

Doc. No.: MG-HT-23-04 Rev.:01

How To Manual

Subject: How to connect Ethernet cable CAT7 Tough S/FTP LSHF-FR

Affected Systems:
VDR G4e

Introduction:
MacGregor has decided to use another type of cable connection as a second option.
The preferred cable and standard solution is the LEONI Ethernet-Link Cat5e (item code 1901030 ).
The LEONI cable allows cable length up to 60 meters.

The optionally solution Tough Cat 7 (item code 400214156 )is usable up to 40 meters only.

It’s using 4 pairs , Al-laminated plastic foil around each pair.

Created: Landgraf 02.03.2023


Audited: Koepke 02.03.2023 Rev. 01
Released: Landgraf 02.03.2023 Page: 1 from 7
Integrated management IS-QM-15-01 How To Manual

Cable connection to the VDR for Nemo 3.0 and Float Free Capsule Tron40VDR AIS Epirb

A. For connecting the Nemo 3.0 to the VDR use mainly the multi data cable (LEONIE) or
optional the DRAKA Tough Cat 7 S/FTP LSHF-FR.

The cable has 4 twisted pairs, in total 8 wires.


4 wires need to use for network connection,
and the other 4 wires need to use for
the 24V/DC power supply.

B. VDR connections of Tough Cat 7 network cable to LAN Adapter

The shield of the network cable must be connected to the grounded LAN Adapter.
Connect the cable to the corresponding ethernet unit according to the color code.

Ethernet
White / Orange (1) : TX+
Orange (2) : TX-
Green / White (3) : RX+
Green (6) : RX-

Power 24V DC
White Brown / Brown (5) : 24V
White Blue / Blue (8) : 0V

The wire pairs for network communication have to be


twisted as far as possible.

Created: Landgraf 02.03.2023


Audited: Koepke 02.03.2023 Rev. 01
Released: Landgraf 02.03.2023 Page: 2 from 7
Integrated management IS-QM-15-01 How To Manual

Cable connection to the Nemo 3.0

A. For opening the FRM NEMO 3.0 for plugging in the cable connection refer to the
FRM NEMO 3.0 User Manual chapter 4.4
For connecting the Multi Data Cable refer to the NEMO 3.0 user manual.

B. Led the cable head (internal connections of network cable) through the threaded
connection of the screw connection until the gray coating protrudes the screw connection
slightly (5mm) inside the Nemo foot.

Screw the union nut with the threaded


connection by means of an open-end wrench (24mm).

C. Connect the cable shield capacitively to the


Nemo foot inside the Nemo.

Put on the shielding clamp on the exposed


piece of the cable shield.

Make sure that the clamp does not have


short-circuit to the box.

Created: Landgraf 02.03.2023


Audited: Koepke 02.03.2023 Rev. 01
Released: Landgraf 02.03.2023 Page: 3 from 7
Integrated management IS-QM-15-01 How To Manual

D. Connect the cables to the green plug according to the following code.

Ethernet
White / Orange (1) : TX+
Orange (2) : TX-
Green / White (3) : RX+
Green (6) : RX-

Power 24V DC
White Brown / Brown (5) : 24V
White Blue / Blue (8) : 0V

Open the orange keys of the plug by means


of a small screwdriver.

Plug in the insulated wires without the wire end ferrules until the end.

Close the keys by means of the screwdriver.

E. Completely installed network cable in Nemo 3.0

F. For reclosing the electronic unit of the Nemo 3.0 refer to the
FRM NEMO 3.0 User Manual chapter 4.5

Created: Landgraf 02.03.2023


Audited: Koepke 02.03.2023 Rev. 01
Released: Landgraf 02.03.2023 Page: 4 from 7
Integrated management IS-QM-15-01 How To Manual

Cable connection to the FFC Tron40VDR AIS EPIRB

A. For connecting the Multi Data Cable refer to the VDR G4e Technical Manual.
B. In order to pull in the cable Tough Cat 7 into the FFC connection box, it is mandatory to
reduce the cable insertion to 13mm.
The reducer is already in place.

C. Led the cable head (internal connections of network cable) through the threaded
connection of the screw connection until the gray coating protrudes the screw connection
slightly (5mm) inside the FFC connection box.

Screw the union nut with the threaded


connection by means of an open-end wrench (24mm).

Created: Landgraf 02.03.2023


Audited: Koepke 02.03.2023 Rev. 01
Released: Landgraf 02.03.2023 Page: 5 from 7
Integrated management IS-QM-15-01 How To Manual

D. Connect the cable shield capacitively to the


FFC Connection Box foot inside the box.

Put on the shielding clamp on the exposed


piece of the cable shield.

Make sure that the clamp does not have


short-circuit to the box.

E. Connect the cables to the green plug according to the following code.

From up to down:
Power 24V DC
White Brown / Brown : PW+ 24V
White Blue / Blue : PW- 0V
Green : RX-
Green / White : RX+
Orange : TX-
White / Orange : TX+

Open the orange keys of the plug by means


of a small screwdriver.

Plug in the insulated wires without the wire end ferrules until the end.

Close the keys by means of the screwdriver.

Created: Landgraf 02.03.2023


Audited: Koepke 02.03.2023 Rev. 01
Released: Landgraf 02.03.2023 Page: 6 from 7
Integrated management IS-QM-15-01 How To Manual

F. For connecting the cable from the FFC to the Connection Box refer to the VDR G4e
Technical Manual and to the VDR drawing.
G. Installed cable from VDR to FFC Connection Box

H. After all cable connections close the FFC Connection Box accordingly

Created: Landgraf 02.03.2023


Audited: Koepke 02.03.2023 Rev. 01
Released: Landgraf 02.03.2023 Page: 7 from 7