You are on page 1of 7

Product data sheet

M20S-03140A122, M20E-03140A122
M2000 Standard

SAFETY MULTIBEAM SENSORS


M20S-03140A122, M20E-03140A122 | M2000 Standard
SAFETY MULTIBEAM SENSORS

A Ordering information

System part Type Part no.

B Sender
Receiver
M20S-03140A122
M20E-03140A122
1018188
1018189

C Important notes: 1.) Concerns installation as a spare part: This type 2 device may be used as per section 1, paragraph (2a) of
Machinery Directive 2006/42/EC within the EU as a spare part for identical PL d/SIL2 devices only if the machine was put on

D
the market before 10/5/2015. Keep this note with your machine documentation. If the machine is resold, this note must be
passed on to the next buyer. 2.) Concerns installation in new machines: Due to the amendment to the EN/IEC 61496-1 stan-
dard, this type 2 device may only be installed on new machines up to PLc/SIL1 as of 5/10/2015.

Other models and accessories www.sick.com/M2000_Standard

E Illustration may differ

F
Detailed technical data
Features

H Scanning range
Low scanning range
0 m ... 25 m, configurable

0 m ... 6 m

I Great scanning range


Number of beams
2 m ... 25 m

J
Beam separation or resolution 400 mm

Response time 8 ms

Synchronization Optical synchronisation

K Safety-related parameters
Type Type 2 (IEC 61496-1)

L Safety integrity level SIL1 (IEC 61508)


SILCL1 (EN 62061)

M Category Category 2 (EN ISO 13849)

Test rate (internal test) 13 /s (EN ISO 13849) 1)

N
Maximum demand rate ≤ 8 min⁻¹ (EN ISO 13849) 2)
Performance level PL c (EN ISO 13849)

PFHD (mean probability of a dangerous fail- 6.6 x 10-9 (EN ISO 13849)

O ure per hour)


TM (mission time) 20 years (EN ISO 13849)

P Safe state in the event of a fault

1)
At least one OSSD is in the OFF state.

 Internal test. The test rate may not be exceeded if an external test is performed.

Q
2)
 Between two requirements on a safety-related response of the device, at least 100 internal or external tests must be carried out.

Functions

R
Functions Delivery status
Beam coding ✔ Uncoded

External device monitoring (EDM) ✔

S
T 2 SAFETY LIGHT-BEAM SENSORS | SICK Product data sheet | 2023-03-30 23:07:47
Subject to change without notice
M20S-03140A122, M20E-03140A122 | M2000 Standard
SAFETY MULTIBEAM SENSORS

Functions Delivery status


Configurable scanning range ✔

Interfaces
System connection
Permitted cable length 15 m 1)

Permitted cross-section ≥ 0.25 mm²


Configuration method Hard wired

Display elements LEDs


7-segment display

1)
 Depending on load, power supply and wire cross-section. The technical specifications must be observed.

Electrical data
Protection class III (IEC 61140)

Supply voltage VS 24 V DC (19.2 V DC ... 28.8 V DC) 1)


Power consumption 5 W (DC) / 3.7 W (DC) (depending on type)

Output signal switching devices (OSSDs) 2 PNP semiconductors, short-circuit protected, cross-circuit monitored  2)
ON state, switching voltage HIGH 24 V DC (VS – 2.25 V DC ... VS)

OFF state, switching voltage LOW ≤ 1 V DC


Current-carrying capacity per OSSD ≤ 500 mA

1)
 The external voltage supply must be capable of buffering brief mains voltage failures of 20 ms as specified in EN 60204-1. Suitable power supplies are available as
accessories from SICK.
2)
 Applies to the voltage range between –30 V and +30 V.

Mechanical data
Dimensions See dimensional drawing

Housing cross-section 48 mm x 40 mm

Ambient data
Enclosure rating IP65 (EN 60529)

Ambient operating temperature 0 °C ... +55 °C

Storage temperature –25 °C ... +70 °C

Air humidity 15 % ... 95 %, Non-condensing

Shock resistance 10 g, 16 ms (IEC 60068-2-29)

Other information
Wave length 950 nm

Classifications
eCl@ss 5.0 27272703

eCl@ss 5.1.4 27272703

eCl@ss 6.0 27272703

eCl@ss 6.2 27272703

eCl@ss 7.0 27272703

eCl@ss 8.0 27272703

eCl@ss 8.1 27272703

eCl@ss 9.0 27272703

2023-03-30 23:07:47 | Product data sheet SAFETY LIGHT-BEAM SENSORS | SICK 3



Subject to change without notice
M20S-03140A122, M20E-03140A122 | M2000 Standard
SAFETY MULTIBEAM SENSORS

A eCl@ss 10.0
eCl@ss 11.0
27272703

27272703

B
eCl@ss 12.0 27272703

ETIM 5.0 EC001832

ETIM 6.0 EC001832

C ETIM 7.0
ETIM 8.0
EC001832

EC001832

D UNSPSC 16.0901 46171620

E Dimensional drawing (Dimensions in mm (inch))

F 8
(0.31)
42.9
(1.69)
1.7
(0.07)

1 2
Ø 8.4
48 (1.89)

(0.33)
3
75 (2.95)
68 (2.68)

4
(1.75)
44.4

H 11.9
(0.47) 20
48 (0.79)

I (1.89)

6
5
14
(0.55)
40
(1.57)

(0.24)

J
(0.04)

(0.14)

42.3
3.5
1

(1.67)
L4

L3

L5
L2

10.5
L1
(0.09)

K
2.2

L6
(0.41)

S1
A1

22.4

L
25.6
(0.88) (1.01)

M
76.3 (3.00)
48 (1.89)

N
(1.38)
35

42.6
(0.89)
22.5

O
(1.68)

6
L1 L2 L3 L4 L5 L6

P 2
3
500
400
-
-
630
931
697
998
588
888
718
1,019
655
956
675
976

Q 4
6
300
-
-
170
1,031
916
1,098
983
989
874
1,119
1,004
1,056
941
1,076
960
7 - 170 1,073 1,140 1,031 1,161 1,098 1,118

R 8 - 116 851 919 809 939 877 896


8 - 170 1,231 1,298 1,189 1,319 1,256 1,275

S
T 4 SAFETY LIGHT-BEAM SENSORS | SICK Product data sheet | 2023-03-30 23:07:47
Subject to change without notice
M20S-03140A122, M20E-03140A122 | M2000 Standard
SAFETY MULTIBEAM SENSORS

L1 L2 L3 L4 L5 L6
9 - 170 1,388 1,455 1,346 1,476 1,413 1,433

Connection diagram
M2000 Standard with 8-pin system connection for UE48-2OS with restart interlock and external device monitoring

+24 V DC

1)
x y
s r k1 k2
1 1
Sel1 Sel1
x y
2 2
+24 V +24 V z
3 3
Sel2 Sel2 k1
4 4
n.c. EDM
5 5 k2
Test OSSD1
z
6 6
HRANGE OSSD2
7 7
GND GND
8 8
Shield Shield
S1
M2000
S33 S11 S12 S31 A1 13 23 31

k1
UE48-2OS2D2
S34 S35 S21 S22 A2 14 24 32
k2

2)
K1 K2

0V
E182602/00/2017-06-12
3) PELV

Recommended accessories
Other models and accessories www.sick.com/M2000_Standard

Brief description Type Part no.

Alignment aids
Laser alignment aid for various sensors, laser class 2 (IEC 60825). Do not look into AR60 1015741
the beam!, 19 mm x 67.3 mm x 66.9 mm

Adapter AR60 for housing cross-section 48 mm x 40 mm AR60 adapter, 48x40 4032461

2023-03-30 23:07:47 | Product data sheet SAFETY LIGHT-BEAM SENSORS | SICK 5



Subject to change without notice
M20S-03140A122, M20E-03140A122 | M2000 Standard
SAFETY MULTIBEAM SENSORS

A Brief description
Adapter AR60 for housing cross-section 48 mm x 40 mm in PU3H device column
Type
AR60 adapter,
Part no.
4056731
48x40, PU3H

B Mounting brackets and plates

C 4 pieces, Mounting kit 1, mounting bracket, rigid, L-shaped, including fixing screws
and washers
BEF-3WNGBAST4 7021352

D Terminal and alignment brackets


4 pieces, Mounting kit 6, side bracket, rotatable, zinc diecast BEF-1SHABAZN4 2019506

E 4 pieces, Omega bracket, rotatable, fixable with only one screw, for mounting on the BEF-2SMMEAAL4 2044847
swivel mount

F 4 pieces, Mounting kit 2, rotatable, swivel mount, Polyamide PA6 BEF-2SMMEAKU4 2019659

H
I
J
K
L
M
N
O
P
Q
R
S
T 6 SAFETY LIGHT-BEAM SENSORS | SICK Product data sheet | 2023-03-30 23:07:47
Subject to change without notice
SICK at a glance
Online data sheet

SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applica-
tions. A unique range of products and services creates the perfect basis for controlling processes securely
and efficiently, protecting individuals from accidents and preventing damage to the environment.

We have extensive experience in a wide range of industries and understand their processes and require-
ments. With intelligent sensors, we can deliver exactly what our customers need. In application centers in
Europe, Asia and North America, system solutions are tested and optimized in accordance with customer
specifications. All this makes us a reliable supplier and development partner.

Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the ma-
chine life cycle and ensure safety and productivity.

For us, that is “Sensor Intelligence.”

Worldwide presence:
Contacts and other locations – www.sick.com

SICK AG | Waldkirch | Germany | www.sick.com