You are on page 1of 1

Pump Performance Datasheet

Customer : Quote number : 154873


Customer enquiry : Pump Size : RKB32/14H
Project : Default Stages : 11
Item number : ITEM 1 Based on curve number : HD12786AA0 Rev 1
Usage - Tertiary : IPH-WSS Date last saved : 15 Jun 2023 4:26 PM
Quantity :1 Note - Only duty point is guaranteed as per testing standard.
Operating Conditions Liquid
Flow, rated : 8.00 m3/h Liquid Type/ Application : Water
Differential Head (requested) : 260.0 m Additional liquid description : CLEAR WATER
Differential Head (actual) : 260.0 m Solids diameter, max : 0.00 mm
Suction pressure, rated / max : 0.00 / 0.00 bar.g Solids/Bagasse/Stock consistency by : 0.00 %
NPSH available, rated : Ample volume
Site Supply Frequency : 50 Hz Temperature, max : 20.00 deg C
Performance Fluid density rated : 1.00 SG
Speed, rated : 2935 rpm Viscosity, rated : 1.00 cSt
Impeller diameter, rated (approx.) : 135 mm Vapor pressure, rated : 0.02 bar.a
Impeller diameter, maximum : 138 mm Material
Impeller diameter, minimum : 110 mm Material selected : 20 MOC-CI260(012)/BR
Efficiency : 53.63 % LTB2(110)/40C8(587)
NPSH required / margin required : 1.64 / 0.50 m Pressure Data
nq (imp. eye flow) / S (imp. eye flow) : 16 / 102 Metric units Maximum working pressure : 27.21 bar.g
Minimum Continuous Safe Flow (MCSF) : 2.43 m3/h Maximum allowable working pressure : 30.20 bar.g
Head, maximum, rated diameter (approx.) : 278.0 m Maximum allowable suction pressure : 9.81 bar.g
Head rise to shutoff (approx.) : 6.91 % Hydrostatic test pressure : 45.11 bar.g
Flow, best eff. point : 11.69 m3/h Driver & Power Data (@Max density)
Flow ratio, rated / BEP : 68.41 % Driver sizing specification : Rated Power
Diameter ratio (rated / max) : 97.83 % Margin over specification : 0.00 %
Head ratio (rated dia / max dia) : 94.53 % Service factor : 1.00
Cq/Ch/Ce/Cn [HI2010] : 1.00 / 1.00 / 1.00 / 1.00 Power, hydraulic : 5.66 kW
Selection status : Acceptable Power, rated : 10.55 kW
Performance testing standard : ISO 9906 / ANSI-HI 14.6 Power, maximum, rated diameter : 16.15 kW
Gr 2B Minimum recommended driver rating : 18.50 kW / 24.81 hp

20
Power - kW

15 Power

10

400 100
Minimum Continuous Safe Flow (MCSF)
360 90

320 80

280 70
Efficiency - %

135 mm
240 60
Head - m

200 50
Efficiency
160 40

120 30

80 20

40 10

0 0
NPSHr - m

4 NPSHr
2

0
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Flow - m3/h

· · ,
Phone:

Version: 23.1.2

You might also like