You are on page 1of 6

Perencanaan surface casing

Diketahui
Diameter casing (OD) : 13.375 in
Panjang casing : 3,000 ft (MD)
Panjang minimum tiap seksi : 1,000 ft
Gradient tekanan rekah pada kaki casing : 14 ppg
Semen 0 – 2,000 ft : 11.7 ppg
2,000 – 3,000 ft : 15.6 ppg
Minimum drift diameter : 12.25 in
Densitas Lumpur saat casing dipasang : 11 ppg
Design factor burst/collapse : 1.1
Tension : 1.6
Temperature : 1200 F
Z : 0.9

Diketahui
Diameter Casing (OD) 13.375 inch
Panjang Casing (Ls) 3000 ft (MD)
Panjang Minimum tiap seksi 1000 ft
gradient tekanan rekah (Gfr) 14 ppg
semen 0 - 2000 ft 11.7 ppg
2000 - 3000 ft 15.6 ppg
minimum drift diameter 12.25 inch
densitas lumpur saat casig dipasang 11 ppg
design factor burst/collapse 1.1
tension 1.6
temperature 120 F
z= 0.9
gradient hidrostatik gas (rho g) = 0.115 psi/ft
Depth
0
3000
A B C D
1995 0 1995 2194.5
2340 1395 945 1039.5
Surface Casing (Beban Burst)
0 500 1000 1500 2000 2500
0

500

1000
A
Depth (ft)

B
1500 C
D
2000

2500

3000
Pressure (psi)
Diketahui
Diameter Casing (OD) 13.375 inch
Panjang Casing (Ls) 3000 ft (MD)
Panjang Minimum tiap seksi 1000 ft
gradient tekanan rekah (Gfr) 14 ppg
semen 0 - 2000 ft 11.7 ppg
2000 - 3000 ft 15.6 ppg
minimum drift diameter 12.25 inch
densitas lumpur saat casig dipasang 11 ppg
design factor burst/collapse 1.1
tension 1.6
temperature 120 F
z= 0.9
gradient hidrostatik gas (rho g) = 0.115 psi/ft

Depth Internal
0 0
2000 0
3000 0

Surface Casing (Beb


0 500 1000 150
0
500
1000
Depth (ft)

A Resultan (karena didalam casing kosong 1500


2000
2500
3000
3500
Pressure (psi)
Eksternal A B
0 0 0
1216.8 1216.8 1338.48
2028 2028 2230.8

Surface Casing (Beban Collapse)


0 500 1000 1500 2000 2500
0
500
000
500 A
B
000
500
000
500
Pressure (psi)

You might also like