BENDIX® TU-FLO® 750 AIR COMPRESSOR PIECE NO.
TAG
(CROSS SECTION)
DESCRIPTION
BENDIX® TU-FLO® 750 AIR COMPRESSOR
The function of the air compressor is to provide and main- (EXTERIOR)
tain air under pressure to operate devices in the air brake
and/or auxiliary air systems. The Tu-Flo® 750 compressor
is a two cylinder single stage, reciprocating compressor UNLOADER
This is the cut pages sample. Download all 40 page(s) at: ManualPlace.com
Downloaded from www.Manualslib.com manuals search engine
UNLOADER COVER
AIR DISCHARGE PLATE
AIR
DISCHARGE
WATER
AIR
AIR INLET
INLET PORT
PORT
INLET INLET VALVE
DISCHARGE VALVE DISCHARGE HELD OPEN
VALVE OPEN VALVE BY UNLOADER
CLOSED CLOSED PISTON
PISTON
MOVING
DOWN
AIR GOVERNOR
ernor closes and exhausts the air from above the unloader
DISCHARGE PORT pistons. The unloader springs force the pistons upward and
PORT
the inlet valves return to their seats. Compression is then
resumed.
Compressor
Governor
(Governor plus Synchro valve Service Reservoir
for the Bendix® DuraFlo™ 596 (Supply Reservoir)
Compressor)
Reservoir Drain
DUTY CYCLE The discharge line must maintain a constant slope down
from the compressor to the air dryer inlet fitting or reservoir
The duty cycle is the ratio of time the compressor spends
to avoid low points where ice may form and block the flow. If,
building air to the total engine running time. Air compres-
instead, ice blockages occur at the air dryer or reservoir
sors are designed to build air (run "loaded") up to 25% of the
inlet, insulation may be added here, or if the inlet fitting is a
time. Higher duty cycles cause conditions that affect air
typical 90 degree fitting, it may be changed to a straight or
brake charging system performance which may require ad-
45 degree fitting. Shorter discharge line lengths or insula-
ditional maintenance. Factors that add to the duty cycle
tion may be required in cold climates.
are: air suspension, additional air accessories, use of an
undersized compressor, frequent stops, excessive leakage While not all compressors and charging systems are
from fittings, connections, lines, chambers or valves, etc. equipped with a discharge line safety valve this component
Refer to Table A in the Troubleshooting section for a guide to is recommended. The discharge line safety valve is installed
various duty cycles and the consideration that must be given in the cylinder head (Tu-Flo® 550/750) or close to the com-
to maintenance of other components. pressor discharge port and protects against over pressurizing
the compressor in the event of a discharge line freezeup.
COMPRESSOR INSTALLATION
DISCHARGE LINE
HOLE
The discharge line allows the air, water-vapor and oil-vapor
mixture to cool between the compressor and air dryer or
reservoir. The typical size of a vehicle's discharge line, (see
column 2 of Table A in the Troubleshooting section) assumes
a compressor with a normal (less than 25%) duty cycle,
THREAD
operating in a temperate climate. See Bendix and/or other
air dryer manufacturer guidelines as needed.